A.O. Smith VW-500, VW-750, VW-1000, VW-1500 User Manual

0 (0)
A.O. Smith VW-500, VW-750, VW-1000, VW-1500 User Manual

® Domestic Hot Water Boilers

 

VW-500

HOT WATER SUPPLY BOILERS

through

VW-2000

FEATURES

 

The VF™ Boiler series delivers an exceptionally high thermal efficiency by combining an advanced modulating venturi-mixing gas/air ratio system with a vertical multi-pass copper heat exchanger for outstanding efficiency of up to 88% and low NOx emissions that meet or exceed the most stringent standards.

The VF™ Boiler is capable of firing from 100% to 25% or a 4:1 turndown ratio of rated input based on the current system demand. The VF’s modulating capability is virtually limitless, and the boiler’s output is based strictly on the current system demand and the required BTUs needed to maintain the desired system set point temperature.

ADVANCED HIGH EFFICIENCY, LOW NOx COMBUSTION TECHNOLOGY

Venturi-mixing gas/air ratio system - Works with variable speed blower to precisely mix gas and air throughout firing range.

4:1 Turndown - Fully modulating capability prevents energy-stealing short cycling and provides smooth system operation with higher overall system efficiencies

LOW NOx OPERATION

Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements for low NOx emissions

ADVANCED MODULATING CONTROL

Includes remote tank temperature control to adjust tank temperature at the boiler - Modulates the boiler to maintain tank set point temperature within +/-1 degree

Infinite boiler output control between 25% and 100% fire

LED read out - Provides current boiler status in plain English with help screens to assist should a fault occur

Controls every electrical boiler function and provides on board diagnostics

iCOMM™ Compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information.

ALL BRONZE FACTORY MOUNTED PUMP

Integrally mounted, wired, and controlled by the boiler control

Factory-sized for proper flow between boiler and storage tank

Allows 50 equivalent feet of piping between boiler and tank

HIGH EFFICIENCY COPPER FIN TUBE HEAT EXCHANGER

Vertical straight tube 2 or 4 pass heat exchanger design encircles the burner with a combustion chamber that is a 360° wall of copper fin tubes

Rust-resistant operation - All internal heat exchanger non-copper surfaces are

glasslined with A. O. Smith’s proprietary porcelain glass coating, which far exceeds competitive coatings

Impervious to thermal shock

COMPACT, LOW-PROFILE DESIGN

Zero clearance on sides for 500-1000 models, 4 inches on sides for 1500-2000 models Ideal for multiple boiler installations

STANDARD VENT OR DIRECT VENT FLEXIBILITY

Standard vent configuration, vertical or horizontal sidewall

Two-pipe direct venting vertical and/or horizontal sidewall, with all combustion makeup air drawn from outside the building

FACTORY START-UP INCLUDED

Required for activating warranty and assuring

maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE Certified Start-Up.

 

Page 1 of 4

Revised September 2010

AOSDG25000

® Domestic Hot Water Boilers

CATEGORY IV LISTED

Requires AL29-4C gas tight rust resistant venting material

PROFESSIONAL START-UP SERVICE INCLUDED

Assures optimum performance for each installation

MEETS THE THERMAL EFFICIENCY AND STANDBY

LOSS REQUIREMENTS OF THE U. S. DEPARTMENT

OF ENERGY AND CURRENT EDITION ASHRAE/

IESNA 90.1

5-YEAR HEAT EXCHANGER WARRANTY

For complete information, consult written warranty or contact A. O. Smith

OTHER VFBOILER FEATURES:

ASME 160# W.P.

ASME RATED PRESSURE RELIEF VALVE, 125 PSI.

FACTORY MOUNTED FLOW SWITCH

MEETS CSD-1 CODE-–FACTORY STANDARD

BRASS DRAIN VALVE

LOW GAS PRESSURE SWITCH

DIGITAL INLET/OUTLET TEMPERATURE READOUT

MANUAL RESET HI-LIMIT

ALL BRONZE FACTORY MOUNTED PUMP

VF™ BOILER APPROVED OPTIONS:

SEQUENCING PANEL

ALARM BUZZER

SIDEWALL VENT KITS

VERTICAL AND HORIZONTAL DIRECT VENT KITS

SKID-MOUNTED SYSTEMS

DRY CONTACTS FOR ANY BOILER FAILURE

LOW WATER CUTOFF

LP GAS

CUPRO-NICKEL HEAT

EXCHANGER TUBES

ENERGY MANAGEMENT

INTERFACE ADAPTER (BacNet, Lowworks, for other contact Factory)

 

Input

Water

 

 

Temperature Rise - °F (°C)

 

 

 

 

 

 

 

 

 

 

 

 

Model

Rating

Flow

40

60

 

80

90

100

 

120

140

 

BTU/Hr.

 

 

 

 

(22)

(33)

 

(44)

(90)

(56)

 

(67)

(78)

 

 

 

 

 

VW-500

500,000

GPH

1,268

845

 

634

563

507

 

423

362

LPH

4,797

3,198

 

2,399

2,132

1,919

 

1,599

1,371

 

 

 

 

VW-750

750,000

GPH

1,901

1,268

 

951

845

761

 

634

543

LPH

7,196

4,797

 

3,598

3,198

2,878

 

2,399

2,056

 

 

 

 

VW-1000

1,000,000

GPH

2,535

1,690

 

1,268

1,127

1,014

 

845

724

LPH

9,595

6,397

 

4,797

4,264

3,838

 

3,198

2,741

 

 

 

 

VW-1500

1,500,000

GPH

3,780

2,520

 

1,890

1,680

1,512

 

1,260

1,080

LPH

14,307

9,538

 

7,154

6,359

5,723

 

4,769

4,088

 

 

 

 

VW-2000

2,000,000

GPH

5,040

3,360

 

2,520

2,240

2,016

 

1,680

1,440

LPH

19,076

12,718

 

9,538

8,478

7,631

 

6,359

5,450

 

 

 

 

Note: Maximum gas supply pressure: 13.8˝ W.C. natural gas, 13.8˝ propane

Minimum gas supply pressure: 4˝ W.C. natural gas, 8˝ propane

Electrical Power: 120 Volts, 60 Hertz, 30 Amps..

For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

Revised September 2010

Page 2 of 4

www.hotwater.com