Antari X-515 PRO, X-510 PRO User Manual [de]

0 (0)

X-510PRO , X-515PRO FOG MACHINE

USER MANUAL

English Français Deutsch

2011 Antari Lighting and Effects Ltd.

1

2

Congratulations on the purchase of your new

ANTARI X-PRO SERIES Fogger

Introduction

Thank you for choosing an ANTARI Fogger of the X-PRO SERIES. There are two models available: the X-510PRO (1000W) and the X-515PRO (1500W). Both units are rugged and powerful state-of-the-art machines. Besides their ability to operate silently, these new models are user-friendly in terms of controlling and operating. For Antari X-515PRO fog machine, an optional W-DMX function (W-DMX) is available. Prior to use, we suggest that you carefully read all of the instructions. By following the suggestions found in this user manual, you can look forward to the reliable and satisfactory performance of your ANTARI Fog Machine for years to come.

Cautions

Risk of electric shock. Disconnect the appliance from the electric

!supply before removing the cover.

Note: There are no user serviceable parts inside.

Important Safeguards

-Danger of Electric Shock

*Keep this device dry.

*For inside use only. Not designed for outside use.

*For all models, use 3-prong grounded electrical outlet only. Prior to use take care to determine that the unit is installed at the rated voltage.

*Always unplug your ANTARI Fog Machine before filling its tank.

*This machine is not wateror splash-proof. If moisture, water, or fog liquid gets inside the housing, immediately unplug the unit and wipe off the moisture and keep it dry.

Danger of Burns

*Structural modification inside the machine is not allowed at anytime. Please do not attempt to modify the machine by removing the cover, otherwise burns may result.

*For adult use only. Never leave the unit running unattended.

3

*Never aim the output nozzle directly at people.

*Machine will warm up when operating, locate the fog machine in a well-ventilated area. Never cover the unit's vents. In order to guarantee adequate ventilation, allow a free air space of at least 30 cm around the sides and top of the unit.

*Never aim the output nozzle at open flames.

*The output nozzle becomes very hot during operation (200°C). Keep flammable materials at least 50 cm away from the nozzle.

*Always allow your ANTARI X-PRO SERIES Fogger to cool down before attempting to clean or service it.

Danger of Explosion

*Never add flammable liquids of any kind (oil, gas, perfume) to the fog liquid.

*

Use only the high-quality, water-based ANTARI recommended FLG / FLR fog liquid. Other fog

 

liquids may cause clogging or damage to internal parts.

*Always make sure there is sufficient liquid in the fog liquid tank. Operating this unit without liquid will cause overheating.

*If your ANTARI fog machine fails to work properly, discontinue use immediately. Drain all fog liquid from the tank, pack the unit securely (preferably in the original packing material), and return it to your ANTARI dealer for service.

*Always drain tank before mailing or transporting this unit.

*Never drink fog liquid. If it is ingested, call a doctor immediately. If fog liquid comes in contact with skin or eyes, rinse thoroughly with water.

!

Important:

Pay attention to all warning labels and instructions printed on the exterior of

 

your ANTARI X-PRO SERIES Fogger.

 

 

- Unpacking & Inspection

Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact.

The shipping carton should include the following items:

1.One unit with power cable of the X-PRO SERIES series: X-510PRO or X-515PRO

2.X-10PRO Control Module with cables

3.Fluid tank

4.User manual

4

Optional Accessories:

1.Hanging bracket

2.Drip tray

3.X-30PRO Wireless Control Module

4.FX-510, FX-515 Flightcase

Before beginning with the initial setup of your X-PRO SERIES Fogger, make sure that there is no evident damage caused by transportation. In the event that the unit's housing or cable is damaged, do not plug it in and do not attempt to use it after having contacted your Antari dealer for assistance.

Setup

1.Remove all packing materials from shipping box. Check that all foam and plastic padding is removed, especially in the nozzle area.

2.Place fog machine on a flat surface and remove fog liquid tank cap.

3.Fill unit about 3/4 full. Use Antari Fog Fluid only. Antari X-510PRO and X-515PRO Foggers only work with uncontaminated Antari FLG/FLR Fog Fluid. Other fluids may cause possible clogging problems and could result in the production of unhealthful fog. The use of other fluids will void the warranty of the Antari X-510PRO and X-515PRO. When filled, place cap back on liquid tank.

WARNING

!Use of any fluid other than ANTARI fog fluid or modification or attempt to unauthorized repair of the X-Seies PRO Fogger will immediately invalidate the warranty.

Operation

*The plug is at a position that is accessible when the machine is in use.

Plug power cord into a grounded electrical outlet. Turn power switch on the rear of unit to “ON” position. Warm-up is completed when the display on control module shows “Ready to Fog”.

*To emit fog, press the appropriate button on the X-10PRO Control Module for the desired length of time.

*The Control Module’s display will cycle “Warming up” and “Ready to Fog” while the machine re-heats to the proper operating temperature.

*When the fluid is running low, the LED inside the tank chamber starts blinking until the tank is refilled again.

*Always monitor liquid level to prevent interrupted operation.

Caution: “Visibility during operation is reduced”.

5

Hanging Bracket

The unit may be installed at floor level or suspended overhead via the hanging bracket. If the unit is to be mounted using the bracket, it is important that the fog does not shoot directly at any one's face. Whatever installation method you choose, do not allow the unit to have more than a 15° angle of inclination.

Important

!Always monitor tank fluid level when you are fogging. Running a fog machine with no fluid can permanently damage the unit.

If you experience low output, pump noise or no output at all, unplug immediately. Check fluid level, the

external fuse, control module connection, and power from the wall. If all of the above appears to be

O.K., plug the unit in again. If fog does not come out after holding the control module button MANUAL down for 30 seconds, check the hose attached to the tank to make sure there is fluid going

through the hose. If you are unable to determine the cause of the problem, do not simply continue

pushing the control module button, as this may damage the unit. Return the machine to your ANTARI

dealer.

Menu Settings With The Button FUNCTION

Setting time intervals for timer operation

Press the button FUNCTION until the display indicates Interval Set . Use the buttons

UP and DOWN to adjust the intervals between the individual fog outputs in timer

mode within the range of 1 and 200 seconds.

6

Setting the output duration for timer operation

- Press the button FUNCTION until the display indicates Duration Set . Use the buttons

UP and DOWN to adjust the duration of the fog outputs in timer mode within the range

of 1 and 200 seconds.

Setting the fog output volume for timer operation

- Press the button FUNCTION until the display indicates Timer Out . Use the buttons

UP and DOWN to adjust the fog output volume in timer mode within the range of 1 % and 100

%.

Setting the fog output volume for continuous operation

- Press the button FUNCTION until the display indicates Volume Out . Use the buttons

UP and DOWN to adjust the fog output volume in continuous mode within the range of 1 % and 100 %.

- To set the unit to continuous fog output, select NON STOP BURST below a value of 1 % or above a value of 100 %.

Setting the DMX512 address

Press the FUNCTION until the display indicates DMX 512 Add . Use the buttons UP and DOWN, to set the machine to the same address as on your DMX controller. Please refer to the chapter DMX512 settings for more information on DMX operation.

Turning the heater on or off

Press the FUNCTION until the display indicates Heater On . Use the button

MANUAL, to switch the heater on or off.

7

Continuous operation

Press the button VOLUME , to activate continuos fog output. The display indicates Volume

followed by the value that was set in menu item Volume Out or NON STOP BURST . To stop the fog output, press the button VOLUME once again.`

Manual operation

For immediate fog output at the maximum volume of fog, keep the button MANUAL pressed.

The display indicates Manual Output . As soon as you release the button, the fog output will stop. The manual operation will take priority over the continuous operation and the timer operation. Even if one of these operating modes is activated, the fog machine will always emit the maximum volume of fog when the button MANUAL is pressed.

Timer operation

In the timer mode, the fog machine will automatically emit fog. The time intervals, duration and fog volume depend on the corresponding menu settings. Press the button TIMER , to activate the timer mode. The display indicates the set time interval. The unit counts down to 0 seconds and emits fog. To deactivate the timer mode, press the button TIMER again.

8

Antari X-30PRO Control Module Operation

X-30PRO Wireless Control Module Operation

All the X-10PRO features plus wireless capability.

The wireless control module X-30PRO consists of a transmitter equipped with two buttons for fog on and off, and a receiver pre-attached to the panel of each X-30PRO.

* Transmitter:

With the transmitter it is possible to emit fog via radio over a distance of up to 50 meters. The transmitter is compatible to any receiver of the X-30PRO and can control an unlimited number of machines in parallel.

Press the button “A”, to emit fog. The button “A” has the same function as the button VOLUME on the control panel, i.e. the fog output depends on the setting of menu item »Volume Out«. The display indicates Volume followed by the defined value or NON STOP BURST when continuous fog output was selected. To stop the fog output, press the button “B”.

* Receiver:

The receiver is tested and pre-attached to the panel of each X-30PRO. Please do not try to remove it. The receiver responds to up to 5 different transmitters that are registered with the machine. The included transmitter has been registered to the machine before shipment. It can be directly operated without any start-up setting.

9

-Registering transmitters

To operate the machine with a different transmitter than the included one, or to operate it with up to 5 different transmitters, each transmitter must be registered first. For this purpose, turn on the machine. When the display indicates Wireless Setup , press the button “A” 1 second on each transmitter. Thus the previous transmitters are cleared from the memory of the receiver. The setting must be completed within 15 seconds after switching on the machine. Then the machine will automatically exit the transmitter setting mode. The display shows Wireless Setup OK . At this point, no further transmitter can be added.

If no transmitter is registered when the machine is switched on, the memory of the receiver will keep the record of the previous operation.

Setting Example 1:

In order to register several transmitters with a machine, turn on the machine. When the display indicates Wireless Setup , press the button “A” 1 second on each transmitter within 15 seconds to establish the signal transmission.

Setting Example 2:

In order to use 1 transmitter to control 2 or more machines, turn on the machines respectively. When the displays indicate Wireless Setup , press the button “A” 1 second on the transmitter within 15 seconds to establish the signal transmission.

- Battery change on the transmitter

If the range of the transmitter decreases, the battery is probably exhausted and must be replaced. For this purpose, take off the housing cover and remove the used battery. Insert a fresh battery as indicated in the battery compartment and refit the housing cover.

- Switching the wireless function on and off

Press the button FUNCTION until the display indicates Wireless On . Use the buttons UP and DOWN to deactivate the wireless function (indication Wireless Off ) and to reactivate it (indication

Wireless On ).

*Note: When warming-up process is completed and wireless function is activated the LCD screen indicates “Ready To Fog W”. (“W” means Wireless) On the contrary, when the wireless function is

deactivated the LCD screen shows “Ready To Fog” (Without “W”).

10

Prior to shipment, the X-510PRO (1000W) and X-515PRO (1500W) Foggers are fully tested and the liquid in the tank and the liquid tube are fully cleaned in-house. When operating the unit for the first time, please press the button MANUAL for 3 to 5 seconds to let the unit circulate. Please do not try to set the Timer function on your first operation. It is normal for the machine to produce some pumping sound for about 3 to 5 seconds. After the machine operates smoothly you can start to set the desired operating functions. In addition, it is recommended to clean the liquid tank and follow the steps mentioned above after each transport.

-The X-510PRO and X-515PRO Foggers have a recycling period after long bursts (X-510PRO: approx. 35 seconds, X- 515PRO: approx. 45 seconds). The machine will shut itself down for a short period (about 100 seconds) in order to heat up again. During this time, no fog can be produced.

It is a normal situation to see some residual fog spurt (1~2 times) after the machine has stopped producing fog. This is due to natural vaporization when there is remaining liquid residue inside the liquid tube and when the machine is still at a high temperature.

11

Maintenance & Storage

Do not allow the fog liquid to become contaminated. Always put the caps back on the fog liquid container and the fog machine liquid tank immediately after filling. Do not operate the fog machine without liquid at any time.

Clean with a dry cloth only. Store dry. Cleaning your fog machine regularly will help reduce costly replacement and repair charges.

Note: All fog machines are prone to clogging due to the thick consistency of fog liquid and the high temperature at which it vaporizes. It is strongly recommended to clean the fogger by running with distilled water after every 2000 hours of operation. A properly maintained fog machine should provide years of reliable use.

It is strongly recommended to test-run the machine on a monthly basis in order to achieve its best fogging condition. A test-run consists of warming up the machine followed by a few minutes of emission. Then please cool down the machine.

Specifications

MODEL

X-510PRO

X-515PRO

POWER

AC100V/120V/230V, 50-60Hz

 

 

 

HEATER

1,000W

1,500W

OUTPUT

10,000 cu.ft/min 350m3/min

20,000 cu.ft/min 710m3/min

 

 

 

OUTPUT PRESSURE

68.6 kpa

49 kpa

HEAT UP TIME

11 min

8.5 min

 

 

 

FLUID CONSUMPTION

17 min/liter (100% output)

8.5 min./liter (100% output)

RATE

 

 

TANK CAPACITY

2.8 liter

6 liter

 

 

 

WEIGHT

11.5 kg

13.2 kg

DIMENSIONS(MM)

L552 W230 H155

L646 W240 H190

 

 

 

Please read and save these instructions.

12

Antari X-515 PRO, X-510 PRO User Manual

13

Antari X-510PRO / X-515PRO on-board DMX settings

Channel A

Volume output

6-255 (5%-100%)

0-5 (OFF)

The X-510PRO and X-515PRO Fog Machines have on-board DMX control. These models use 1 channel to control volume output operation. This channel has a value range of 0 to 255. Timer functions such as duration and interval can be programmed using the DMX controller or the DMX control software used by the lighting and effects operator.

If Channel A has a value from 0 to 5, the unit is OFF.

Between the values 6 to 255 the volume of fog output is regulated. With 6 being the minimum volume of fog produced and 254 approaching the maximum. The volume output rises as the DMX value is increased.

Note: If the unit is assigned to DMX address 124 e.g., Channel A corresponds to DMX address 124.

In general, Antari fog machines of the X-PRO SERIES series with on-board DMX conform to the following performance specifications:

1.Average operating temperature = 250ºC

2.X-510PRO and X-515PRO’s Non Stop Burst function can be selected in the main

FUNCTION 5th sub-menu of “Volume Out”. Please refer to page 4/5 for control module operation.

14

ANTARI LIMITED WARRANTY

Thank you for purchasing an Antari product from an authorized Antari dealer. We take great pride in the highest quality and reliability of our products. Please follow proper operation and storage procedures outlined in your accompanying user manual. Shall you require any further assistance, please kindly contact sales@antari.com

Warranty shall be valid only if the product is purchased from Antari’s authorized distributors or dealers. For warranty service, send the product in original packaging to an authorized distributor or dealer.

All warranties are void if the product has been modified in any manner; if the product has been repaired or serviced by unauthorized personnel; or the product is damaged due to improper use or maintenance as set forth in the instruction manual.

This is not a service contract and does not include standard maintenance or cleaning. All expendables are not covered by this warranty.

Additional warranties provided at the discretion of the distributor dealers shall remain the sole obligation of the distributor or dealer.

NOTE: USE OF ANY FLUID OTHER THAN ANTARI FOG FLUID WILL VOID WARRANTY.

15

Nous vous félicitons pour l'achat de votre nouvelle machine à fumée ANTARI X-PRO.

Introduction

Nous vous remercions d'avoir choisi une machine à fumée ANTARI X-510PRO ou X-515PRO. Vous êtes en possession d'un produit robuste et puissant. En vue d'utiliser correctement votre nouvel appareil, veuillez lire attentivement ce mode d'emploi. Si vous respectez les instructions suivantes, vous profiterez d'une performance solide et convaincante de votre machine à fumée ANTARI pour de nombreuses années.

ATTENTION!

Risques d'électrocution. Protéger de l'humidité. Débrancher avant d'ouvrier le boîtier!

!L'intérieur de l'appareil ne contient pas de parties nécessitant un entretien. L'entretien et les réparations sont à faire effectuer par un revendeur autorisé.

Pour assurer la longévité et le bon fonctionnement de votre machine à fumée, veuillez lire attentivement les instructions suivantes concernant le maniement, la sécurité et l'entretien.

Instructions de sécurité

Risques d'électrocution

Protéger de l'humidité.

L'appareil a été conçu pour un emploi dans des locaux clos. Ne pas utiliser à l'extérieur.

Utilisez uniquement des prises de courant à terre à 3 broches. Avant la première mise en marche, assurez vous que l'appareil soit branché à l'alimentation correcte.

Débranchez l'appareil avant de remplir le réservoir.

Assurez vous d'installer la machine à fumée toujours droit.

Eteignez l'appareil ou débranchez-le du secteur, quand il est hors d'usage.

Si de l'humidité, du liquide ou du liqide à fumée devait penétrer à l'intérieur de l'appareil, débranchez immédiatement l'appareil et contactez un technicien ou votre revendeur ANTARI avant de le réutiliser.

16

Danger d'incendie

Pour des raisons leés à la sécurité de l’appareil, la transformation ou la modification de l’appareil par l’utilisateur sont interdites. L’appareil ne doit être ni ouvert.

L'appareil n'est prévu que pour l'usage par des personnes adultes. Installez-le hors de l'atteinte des enfants. Ne jamais faire marcher sans surveillance.

Ne jamais braquer le bec de l'appareil directement sur des Personnes.

Installez l'appareil à un endroit bien aéré. Ne jamais couvrir les orifices d'aération. Pour garantir une aération suffisante, laissez libre un espace de 30 cm autour et au-dessus de l'appareil.

Ne jamais braquer le bec de la machine sur des flammes.

Le bec de la machine devient très chaud (200° C) pendant son fonctionnement. Pour cela, tenez écarté de matériaux enflammables au bec de la machine à une distance minimum de 50 cm.

Laissez refroidir la machine à fumée ANTARI avant toute manipulation.

Risques d'explosion

Ne jamais entremêler des liquides enflammables à composants gazeuz ou huileux au liquide à fumée.

Employez uniquement des liquides à fumée de haute qualité à base d'eau recommandés par votre revendeur. Autres liquides à fumée pourraient causer des problèmes d'encrassage ou des crachotements.

Faites attention qu'il y ait toujours suffisamment de liqude à fumée au réservoir. Un emploi sans liquide pourrait endommager la pompe ou provoquer la surchauffe de l'élément de chauffage.

Si votre machine à fumée ANTARI ne devait plus travailler correctement, l'éteignez mmédiatement. Videz complètement le réservoir, emballez soigneusement l'appareil (au mieux dans son emballage d'origine) et l'envoyez-le à votre revendeur ANTARI.

Toujours vider le réservoir avant d'envoyer ou transporter l'appareil.

Ne jamais avaler le liquide à fumée. Si c'était tout de même le cas, consultez un médecin immédiatement. En cas de contact avec la peau ou les yeux, rincer à grande eau.

ATTENTION!

!Veuillez suivre toute instruction de sécurité appliquée sur le boîtier de votre machine à fume ANTARI.

Déballage & inspection

Ouvrez le carton d'extérieur et assurez vous que tous les parts n'aient subi aucun dommage durant leur transport. Assurez-vous que le carton d'expédition contient les articles suivants:

1.Une unité de machine de fumée X-510PRO ou X-515PRO avec câble secteur

2.X-10PRO module de contrôle

17

Loading...
+ 39 hidden pages