Anritsu MA24208A, MA24218A Data Sheet

Anritsu MA24208A, MA24218A Data Sheet

Technical Data Sheet

Microwave Universal

USB Power Sensors

Low Cost, Compact, and Highly Accurate Power Sensors for RF and Microwave Applications

MA24208A

True-RMS, 10 MHz to 8 GHz

MA24218A

True-RMS, 10 MHz to 18 GHz

MA24208A/MA24218A

Specifications

Introduction

The MA24208A and MA24218A Universal USB Power sensors are designed to provide accurate average power measurements from 10 MHz to 8 GHz and 18 GHz, respectively, over 80 dB of dynamic range. The sensors employ a patented “triple path” architecture that provides True-RMS measurements over the entire frequency and dynamic range (similar to thermal sensors), enabling users to make highly accurate average power measurements for CW, multi-tone, and digitally modulated signals up to 18 GHz.

Features and Benefits

Broad Frequency Range (10 MHz to 18 GHz): Ideal for general purpose, aerospace and defense, satellite and wireless communications applications

True RMS Measurements over 80 dB Dynamic Range: Enables average power measurement on CW, multi-tone, and digitally modulated signals - independent of modulation bandwidth

Best-in-Class Damage Protection (+30 dBm CW, +34 dBm peak < 10 µs): Protects instrumentation investment

No Zeroing Required (for signals > –45 dBm) and Elimination of 1 mW Reference Calibration: Reduces test time and handling in production while maintaining absolute accuracy

Advanced Trigger Capabilities: Facilitates time dependent power measurements (for example, GSM, WiMAX, TD-SCDMA, and LTE)

NIST Traceable Calibration: Provides high-accuracy measurements

Easy to Use with PC or Select Anritsu Handheld Instruments: No benchtop power meter unit needed

Silicone Protective Covering (removable): Provides additional field durability

External Trigger Latching: For pulses as narrow as 20 ns

MA24208A and MA24218A Universal USB Power Sensors

2 of 9

PN: 11410-00841 Rev. D

MA24208A/MA24218A TDS

Specifications

MA24208A/MA24218A

Table of Contents

Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Sensor Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Measurement Uncertainty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

PowerXpert™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Operational Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Regulatory Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Optional Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Definitions

All specifications and characteristics apply under the following conditions, unless otherwise stated:

Warm-Up Time

60 minutes

Operating Temperature Range

0 °C to 50 °C

Characteristic Performance

Characteristic specifications are not tested and are not warranted.

ISO GUM Measurement Uncertainty

Zero and Noise uncertainty expressed with three sigma confidence level.

 

Average and Relative Power uncertainty expressed with two sigma confidence level.

Calibration Cycle

Anritsu recommended calibration interval is 12 months.

 

All specifications subject to change without notice. For the most current data sheet, please visit the Anritsu

 

web site: www.anritsu.com

Notes

MA24208A and MA24218A sensors may have degraded performance when dropped without the removable

 

protective covering. This cover is required for warranted operation.

MA24208A/MA24218A TDS

PN: 11410-00841 Rev. D

3 of 9

Loading...
+ 6 hidden pages