American Standard 6065.111, 6066.111, 6065.521, 6065.121, 6066.121 Installation Manual

...
SELECTRONIC
®
DC POWERED PROXIMITY EXPOSED TOILET FLUSH VALVE
1.1, 1.28, 1.6, 1.6/1.1 & 1.28/1.1 GPF
Exposed Flushometer for 1-1/2" Top Spud Bowls
CLOG RESISTANT
Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
Only 1 sensor for entire Selectronic™ line of faucets, urinals, and
flush valves.
Range can be adjusted manually or with optional remote control.
Sensor Features Low Battery Indicator.
MODEL NUMBERS
6065.111 6066.111 6065.521
6065.121 6066.121 6065.525
6065.161 6066.161 6065.561
6065.721 6066.721 6065.565
6065.761 6066.761
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Certied to comply with ASME A112.19.2
© 2015 AS America, Inc.
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
© 2015 AS America Inc.
1
M965646 REV. 1.4 (7/15)
Thank you for selecting American-Standard...the benchmark of ne quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
Some Residual Water May Remain In The Valve During Shipping.
All American Standard Products Are Water Tested At Our Factory.
Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Flush Valve Body Assembly
3. Vacuum Breaker Tube
4. Spud Coupling Nut and Washers
6. Wall Escutcheon
7. Cover Tube
8. Sweat Adapter
9. Stop Valve
5. Spud Flange
CARE INSTRUCTIONS:
DO: CLEAN THE PRODUCT WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
7
8
6
9
2
SELECTRONIC
DC POWERED PROXIMITY EXPOSED TOILET FLUSH VALVE
1.1, 1.28, 1.6,
1.6 / 1.1, & 1.28/1.1 GPF
®
6065.111
6065.121
6065.161
6065.721
6065.761
MODEL NUMBERS
6066.111
6066.121
6066.161
6066.721
6066.761
6065.521
6065.525
6065.561
6065.565
3
Exposed Flushometer for 1-1/2" Top Spud Bowls
CLOG RESISTANT
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
1
Certified to comply with ASME A112.19.2
© 2015 AS America, Inc.
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
4
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
• Range can be adjusted manually or with optional remote control.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
• Sensor Features Low Battery Indicator.
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
(In Toronto Area only: 1-905-306-1093)
5
2
M965646 REV. 1.4 (7/15)
Roughing-in Dimensions Fig. 1
Right or Left Hand Installation
See (Section 5) for converting Flush Valve to Left Hand Installation.
73 mm
MANUAL
OVERRIDE
BUTTON
120 mm (4-3/4")
(2-7/8")
305 mm MÁX.
(12" MÁX.)
SUPPLY (1" NPT.)
(NPT de 1")
FINISHED WALL
GENERAL DESCRIPTION:
SELECTRONIC® PROXIMITY TOILET FLUSH VALVE Exposed Flushometer for 1-1/2” Top Spud Fixtures
Exclusive, self cleaning piston-type ush valve with proximity operation and manual override. Operates on DC (battery) power. Recommended operating pressure 35 to 80 psi. Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control.
15˚
DETECTION ZONE
400mm-800mm
(15-3/4 TO 31-1/2)
-C-L-
292 mm (11-1/2")
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6
fixture. Consult Codes for details.
*-C-L-
152mm MIN.
(6") MIN.
108mm-134mm (4-1/4" TO 5-1/4")
FOR 1-1/2" TOP SPUD FIXTURES
" (152mm) above
412 mm
(16-3/16")
RECOMMENDED TOOLS; Fig. 2.
1. Teon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
IMPORTANT:
All plumbing and electrical wiring should be installed in accordance with applicable codes and regulations.
• The use of water hammer arrestors is strongly recommended for commercial applications. All piping
behind the walls should be properly secured and fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each xture.
170 mm MÁX. (6-11/16") MÁX.
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Fig. 2
1
2
10'
4
3
6
5
8
7 9 10
• Flush all water lines prior to operation (See Step 4). Dirt and debris can cause ush valve to run continuously.
With the exception of Stop Valve Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!
Protect the chrome or special nish on the Flushometer. DO NOT USE toothed tools on nished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.
This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
3
M965646 REV. 1.4 (7/15)