Allied Telesyn International, Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International, Corp. has been advised of, known, or should have known, the possibility of such damages.
Page 3

Electrical Safety and Emission Statement

Standards
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference­Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emission WARNING
which case the user may be required to take adequate measures.
Immunity Electrical Safety Laser Important
equipment. When you see the your language.
Wichtig
Geräts. Wenn Sie Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt
dette udstyr. Når De ser symbolet sikkerhedsadvarsler i Deres eget sprog.
Belangrijk
deze apparatuur. Wanneer u de veiligheidsinstructies in uw taal.
Important
équipement. Lorsque vous voyez le symbole la traduction de ces instructions dans votre langue.
Tärkeää
Kun näe
Importante
questa apparecchiatura. Il simbolo sicurezza nella propria lingua.
Viktig
utstyret. Når du ser sikkerhetsinformasjonen på ønsket språk.
Importante
equipamento. Quando vir o símbolo idioma no Anexo A.
Importante
instalación de este equipo. Cuando vea el símbolo mensaje de seguridad traducido a su idioma.
Obs
denna utrustning. När du ser säkerhetsmeddelandet på ditt språk.
: This product meets the following standards.
U.S. Federal Communications Commission
Industry Canada
!
EN55022 Class A
: In a domestic environment this product may cause radio interference in
EN50082-1 1997 EN60950, UL1950, CSA 950 EN60825
: Appendix A contains translated safety statements for installing this
: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses
: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af
: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette
! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av
!
: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van
: L'annexe A contient les instructions de sécurité relatives à l'installation de cet
: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet.
!
-symbolin, katso käännettyä turvaohjetta liitteestä A.
: l’Appendice A contiene avvisi di sicurezza tradotti per l’installazione di
: O Anexo A contém advertências de segurança traduzidas para instalar este
: El Apéndice A contiene mensajes de seguridad traducidos para la
!
, go to Appendix A for the translated safety statement in
sehen, schlagen Sie in Anhang A den übersetzten
!
, skal De slå op i tillæg A og finde de oversatte
!
ziet, raadpleeg Appendix A voor vertaalde
!
!
, indica di consultare l’Appendice A per l’avviso di
!
, åpner du til Tillegg A for å finne den oversatte
!
, leia a advertência de segurança traduzida no seu
!
, skall du gå till Bilaga A för att läsa det översatta
!
, reportez-vous à l'annexe A pour consulter
!
, vaya al Apéndice A para ver el
1
!
2
!
3
!
4
5
iii
Page 4
Page 5

Table of Contents

Electrical Safety and Emission Statement
Welcome to Allied Telesyn
Where to Find Web-based Guides ................................................................... vii
Document Conventions .................................................................................... vii
Contacting Allied Telesyn............................................................................... viii
Online Support .........................................................................................viii
Telephone and Fax Support..................................................................... viii
E-mail Support .........................................................................................viii
Returning Products ........................................................................................... ix
FTP Server......................................................................................................... ix
For Sales or Corporate Information .................................................................. x
Tell Us What You Think .................................................................................... x
Overview
Features and Components ................................................................................. 2
Network Configurations..................................................................................... 7
Installing the AT-MC300 Series Media Converter........................................... 9
Troubleshooting................................................................................................ 16
Technical Specifications................................................................................... 18
Warranty Registration ..................................................................................... 19
........................................................................................................... 1
100Base-FX Fiber Optic Port...................................................................... 3
100Base-TX Twisted Pair Port ................................................................... 3
MDI/MDI-X Switch ..................................................................................... 3
System and Port LEDs................................................................................ 3
MissingLink/Link Test Button ................................................................... 4
Auto-negotiation Button ............................................................................. 5
External AC/DC Power Adapter................................................................. 7
Selecting a Site............................................................................................ 9
Verifying the Package Contents................................................................. 9
Reviewing Safety Precautions .................................................................. 10
Planning the Installation.......................................................................... 11
Installing the Unit..................................................................................... 13
Verifying the Installation ......................................................................... 15
..........................................................................vii
..............................................iii
v
Page 6
Table of Contents
Appendix A Translated Safety and Emission Information
........................................ 21
Appendix B Technical Support Fax Order
.................................................................... 33
Incident Summary............................................................................................ 33
Appendix C AT-MC300 Series Installation Guide Feedback
..................................... 35
vi
Page 7

Welcome to Allied Telesyn

This guide contains instructions on how to install an AT-MC300 Series Fast Ethernet Media Converter.

Where to Find Web-based Guides

The Allied Telesyn web site at easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in PDF format.
www.alliedtelesyn.com
provides you with an

Document Conventions

This guide uses several conventions that you should become familiar with first before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may result in bodily injury.
vii
Page 8

Contacting Allied Telesyn

There are several ways to contact Allied Telesyn technical support: online, telephone, fax, and e-mail.

Online Support

You can request technical support online by filling out the Online Technical Support Form at

Telephone and Fax Support

www.alliedtelesyn.com/forms/support.htm
.
Americas
United States, Canada, Mexico, Central America, South America Tel: 1 (800) 428-4835, option 4 Fax: 1 (503) 639-3176
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong Tel: (+65) 381-5612 Fax: (+65) 383-3830
Australia
Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 0-1-60-92-15-25 Fax: (+33) 0-1-69-28-37-49

E-mail Support

United States and Canada
TS1@alliedtelesyn.com
Germany
Germany, Switzerland, Austria, Eastern Europe Tel: (+49) 0130/83-56-66 Fax: (+49) 30-435-900-115
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel Tel: (+39) 02-416047 Fax: (+39) 02-419282
Japan
Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+0044) 1235-442500 Fax: (+44) 1-235-442680
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
United Kingdom, Sweden, Norway, Denmark, and Finland
support_europe@alliedtelesyn.com
viii
Page 9
AT-MC300 Series Installation Guide

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations:
North America
2205 Ringwood Ave San Jose, CA 95131 Tel: 1-800-428-4835, option 4 Fax: 1-503-639-3716
Latin America, the Caribbean, Virgin Islands
Tel: international code + 425-481-3852 Fax: international code + 425-483-9458
European Customer Support Centre
10/11 Bridgemead Close Westmead Industrial Estate Swindon, Wiltshire SN5 7YT England Tel: +44-1793-501401 Fax: +44-1793-431099
Mexico and Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 3852
Mexico only: 95-800-424-5012, ext 3852 Fax: international code + 425-489-9191

FTP Server

If you know the name of a device driver that you need for an Allied Telesyn device, you can download the driver by connecting directly to our FTP server
ftp://gateway.centre.com
at
At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login.
.
ix
Page 10

For Sales or Corporate Information

Allied Telesyn International, Corp.
19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191
Allied Telesyn International, Corp.
960 Stewart Drive, Suite B Sunnyvale, CA 94085 Tel: 1 (800) 424-4284 (USA and Canada) Fax: 1 (408) 736-0100

Tell Us What You Think

If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the “AT-MC300 Series Installation Guide Feedback” on page 35 and return the form to us at the address or fax number provided. You can also provide feedback online by filling out the Send Us Feedback Form at
feedback.htm
.
www.alliedtelesyn.com/forms/
x
Page 11

Overview

The AT-MC300 Series Fast Ethernet Media Converters are designed to extend the distance of your network by allowing you to interconnect twisted pair cabling and fiber optic cabling. Each unit features a 100Base-TX twisted pair port with an RJ-45 connector and a maximum operating distance of 100 meters (328 feet). The units also have a 100Base-FX fiber optic port with a VF-45, MT-RJ, or LC connector, depending on the model, and a maximum operating range of 2 kilometers (1.24 miles).
3
FDX
100Base-FX
A/N ON
M/L ON
LNK TST
MC301 FAST ETHERNET MEDIA CONVERTER
LNK
A/N OFF
ACT
100Base-TX
MDI
MDI-X
LNK
LK
ACT M/L ON
PWR
Figure 1
AT-MC300 Series Media Converter (Model AT-MC301)
The media converters are easy to install and do not require any software configuration or management. The units can be installed on a desktop or in an AT-MCR12 chassis.
Table 1 lists the AT-MC300 Series Fast Ethernet Media Converters.
Table 1
AT-MC300 Series Fast Ethernet Media Converters
100Base-FX Fiber Optic Port 100Base-T Twisted Pair Port
Model
Type of Connector
Maximum Distance
Type of Connector
Maximum Distance
AT-MC301 VF-45 2 km (1.24 mi) RJ-45 100 m (328 ft)
AT-MC302 MT-RJ 2 km (1.24 mi) RJ-45 100 m (328 ft)
AT-MC303 LC 2 km (1.24 mi) RJ-45 100 m (328 ft)
1
Page 12

Features and Components

The media converter has the following features:
One 100Base-FX fiber optic port
One 100Base-TX twisted pair port
MDI/MDI-X button
LEDs for unit and port status
Link Test feature
MissingLink feature
External AC/DC Power Adapter
Figure 2 illustrates the front panel of the unit.
M/L ON
LNK TST
MC301 FAST ETHERNET MEDIA CONVERTER
MissingLink/ Link Test Switch
100Base-FX Fiber Optic Port
Auto-negotiation Switch
Figure 2
100Base-TX Twisted Pair Port
100Base-FX
LNK
ACT A/N OFF MDI-X
Fiber Optic Port LEDs
100Base-TX
A/N ON MDI
MDI/MDI-X Switch
Front Panel (Model AT-MC301)
FDX
LNK
LK
ACT M/L ON
Twisted Pair Port LEDs
System LEDs
3
PWR
2
Page 13
AT-MC300 Series Installation Guide

100Base-FX Fiber Optic Port

The 100Base-FX fiber optic port can use either 50/125 or 62.5/125 micron multimode fiber cabling and can operate up to a maximum distance of 2 kilometers (1.24 miles).

100Base-TX Twisted Pair Port

The 100Base-TX twisted pair port operates with Category 5 or better twisted pair cabling and has a maximum operating distance of 100 meters (328 feet). The port has an RJ-45 connector.

MDI/MDI-X Switch

The MDI/MDI-X (Media Dependent Interface/Media Dependent Interface with Crossover) switch on the front panel of the unit eliminates the need for a crossover cable when connecting a device to the twisted pair port on the media converter. The MDI setting is typically used when connecting a DTE device (such as a workstation or printer) to the twisted pair port. The setting of MDI-X is typically used when connecting a switch to the port.

System and Port LEDs

Status LEDs are located on the front panel next to each port. Table 2 lists and defines the LEDs.
Table 2
LED State Description
System LEDs
PWR Steady Green Power is applied to the media converter.
M/L ON Steady Green The MissingLink feature is activated.
OFF The unit is performing a Link Test.
FDX Steady Green The ports are operating in full-duplex mode.
OFF The ports are operating in half-duplex mode.
Port LEDs
LNK Steady Green A link is established on the port.
ACT Flashing Green Data is being received or transmitted by the port.
Status LEDs
3
Page 14

MissingLink/Link Test Button

The MissingLink/Link Test (M/L ON/LNK TST) button allows you to perform a link test on the ports on the media converter. This button also allows you to activate the MissingLink feature on the unit. Both features are describe in the following section.
Link Test.
connections to the two ports on the media converter. The test determines whether the ports are receiving a valid signal from the end nodes connected to the ports. This test is typically used after installation to verify that the unit and connections are operating properly, or whenever you need to test the ports or the integrity of the connections to the nodes connected to the ports. The section “Verifying the Installation” on page 15 contains instructions on how to perform a link test.
MissingLink.
fiber optic port on the media converter to pass the “LINK” status of their connections to each other. When the media converter detects a problem with one of the ports, such as the loss of connection to a node, the device shuts down the connection to the other port, thus notifying the node that the connection has been lost.
For example, if the twisted pair cable to the 100Base-TX port on the media converter were to fail, the media converter would respond by dropping the link on the 100Base-FX fiber optic port. In this way, the media converter notifies the end node connected to the fiber optic port that the connection on the twisted pair port has been lost. If the failure had started with the fiber optic cabling, the unit would drop the link to the twisted pair port.
A link test is a fast and easy way for you to test the integrity of the
Note
Leaving the MissingLink/Link Test button in the Link Test position will not affect the operation of the media converter during normal network operations. However, the MissingLink feature of the media converter is disabled when the button is in the Link Test position.
The MissingLink feature enables the twisted pair port and the
The value to this type of network monitoring and fault notification is that some hubs and switches can be configured to take a specific action in the event of the loss of connection on a port. In some cases, the unit can be configured to seek a redundant path to a disconnected node or send out a trap to a network management station, and so alert the network administrator of the problem. In the example, once the end node connected to the fiber optic port has realized that the connection to the end node on the twisted pair port has been lost on the media converter, the end node can send a trap to the management station, alerting the network administrator of the problem, or attempt to establish a redundant path to the disconnected node.
4
Page 15
AT-MC300 Series Installation Guide
Note
The MissingLink feature is disabled when the MissingLink/Link Test button is in the Link Test position.

Auto-negotiation Button

The AT-MC300 Series Media Converter can operate in either half- or full­duplex mode. Duplex mode refers to the manner in which an end node sends and receives data. An end node that is operating in half-duplex can either send data or receive data, but not both at the same time. A node that is operating in full-duplex mode can send and receive data simultaneously. The best network performance is achieved when a node can operate in full-duplex, since bandwidth is twice that compared to half-duplex.
The media converter is designed to determine the appropriate duplex port for its ports through auto-negotiation. With auto-negotiation, the media converter will determine the capabilities of the end nodes and will set the ports accordingly. For instance, if the end nodes are capable of half-duplex mode only, the unit will set its ports to half-duplex. It is important to note, however, that both end nodes must operate with the same duplex mode. The network will not function properly in situations where one end node is operating in half-duplex and the other is operating in full-duplex.
The auto-negotiation feature on the media converter can be activated or deactivated using the A/N button on the front panel. In nearly all situations, you will want to leave the auto-negotiation capability activated on the AT-MC300 Series Media Converter, so that the unit can determine the appropriate duplex mode for the ports, based on the capabilities of the end nodes. For example, auto-negotiation on the media converter should be left activated in situations where both end nodes are also capable of auto­negotiation, or where both end nodes have been pre-set to the same mode, or are capable of operating in only one duplex mode, such as half-duplex.
There is, however, one situation where it might be necessary for you to disable auto-negotiation on the unit, and that is to prevent a mismatch from occurring between the duplex modes of the end nodes. This can occur where one end node is capable of only half-duplex mode while the other end node will auto­negotiate the duplex mode. For example, Figure 3 illustrates a media converter that is interconnecting a 100Base-TX Ethernet hub capable of only half-duplex operation and a 100Base-TX Ethernet switch that can auto­negotiate the duplex mode.
5
Page 16
With auto-negotiation activated on the media converter, the unit will
STATUS
PORT ACTIVITY
determine that the hub is capable of half-duplex only, and will set the port connected to the hub accordingly. In auto-negotiating with the switch, the media converter will determine that the device is capable of full-duplex, and will set the port connected to the switch to full-duplex. The result is referred to as a classic duplex mode mismatch, where the end nodes are using different duplex modes.
AT-MC301 Media Converter
2 km
PORT ACTIVITY
BASE-T / 100BASE-TX 10
T ETHERNET SWITCH S A F
10BASE-T / 100BASE-TX
100Base switch that can auto-negotiate the
STATUS
RS-232
TERMINAL PORT
100 m
Ethernet hub capable of half-duplex mode only.
duplex mode.
Figure 3
Duplex Mode Mismatch
There are two options to resolving this problem. One option is to manually configure the port on the switch that is connected to the media converter so that it operates only in half-duplex. The second option is to disable auto­negotiation on the media converter using the A/N button. With auto­negotiation disabled on the media converter, the switch will assume that the media converter is capable of only half-duplex mode operation, and will set its port accordingly, eliminating the mismatch in duplex modes between the end nodes.
Note
Changing the A/N button setting requires that you power OFF and power ON the media converter to activate the change on the unit.
6
Page 17
AT-MC300 Series Installation Guide
RS-232
TERMINAL PORT
STATUS
PORT ACTIVITY
10BASE-T / 100BASE-TX
10BASE-T / 100BASE-TX FAST ETHERNET SWITCH

External AC/DC Power Adapter

The power adapter supplies 12 volts DC to the media converter. Allied Telesyn supplies an approved safety compliant AC power adapter for the 120 and 240 V AC versions with an unregulated output of 12 V DC at 1 A.
Figure 4
External AC/DC Power Adapter (North American version)

Network Configurations

Figure 5 shows a network configuration that uses an AT-MC301 media converter to interconnect two AT-8224XL Fast Ethernet switches. This topology is referred to as a standalone configuration because only one media converter is used to interconnect the end nodes.
10BASE-T / 100BASE-TX FAST ETHERNET SWITCH
Legend
10/100 Mbps
100 Mbps (Fiber)
AT-8224XL Switch
10BASE-T / 100BASE-TX
STATUS
RS-232
TERMINAL PORT
PORT ACTIVITY
2 km
100 m
AT-MC301
AT-8224XL Switch with an AT-A16 Expansion Module
Figure 5
Standalone Configuration
7
Page 18
In some network environments, you might need to interconnect two media
STATUS
PORT ACTIVITY
R
S-2
32
TE
RMI
NA
L PORT
S
T
A
T
U
S
PO
R
T
A
CTI
V
I
T
Y
10BASE-T / 100
BA
S
E-TX
1
0
B
ASE-
T
/
10
0
BASE-
T
X F
A
ST
ETH
ER
NET
SW
I
TC
H
converters in what is referred to as a back-to-back topology. In this topology, the converters are used to extend the distance of the network and to convert the cabling from twisted pair to fiber optic, and back again.
Figure 6 illustrates an example of a back-to-back topology. Two AT-MC302 media converters are used to interconnect an AT-8224XL Fast Ethernet Switch and an Ethernet hub.
AT-MC302
Legend
100 Mbps
100 Mbps (Fiber)
2 km
Figure 6
AT-8224XL Switch
100 m
Ethernet hub
AT-MC302
100 m
Back-to-Back Configuration
8
Page 19
AT-MC300 Series Installation Guide

Installing the AT-MC300 Series Media Converter

The following sections explain how to install the media converter. The unit can be installed on a desktop or in an AT-MCR12 chassis.

Selecting a Site

Be sure to observe the following guidelines when selecting a site for the media converter:
Make sure that the unit’s power is accessible and cables can be connected easily.
Air flow around the unit and through its vents on the side and rear must not be restricted.
If you are installing the unit on a desk, make sure it is placed on a level, secure desktop.
Do not place objects on top of the unit.
Do not expose the unit to moisture or water.
Make sure it is in a dust-free environment.
Use dedicated power circuits or power conditioners to supply reliable electrical power to the network devices.

Verifying the Package Contents

Make sure the following items are included in your media converter package. If any of the following items are missing or damaged, contact your sales representative.
One AT-MC300 Series Fast Ethernet Media Converter
Four protective feet (for desktop installation only)
External AC/DC power adapter
This installation guide
Warranty card
9
Page 20

Reviewing Safety Precautions

Please review the following safety precautions before you begin to install the media converter.
Warning
Class 1 laser product. !6
Warning
Do not stare into the laser beam. !7
Warning Electric Shock Hazard
cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables. !8
Warning Lightning Danger
of lightening activity. !9
Warning Power cord is used as a disconnection device:
equipment, disconnect the power cord. !10
: To prevent electric shock, do not remove the
: Do not work on equipment or cables during periods
To de-energize
Caution Pluggable Equipment
: The socket outlet shall be installed near the
equipment and shall be easily accessible. !11
Caution Air vents
: The air vents must not be blocked on the unit and must have
free access to the room ambient air for cooling. !12
Caution Operating Temperature
: This product is designed for a maximum
ambient temperature of 40°C. !13
Caution All Countries
: Install this product in accordance with local and
National Electric Codes. !14
10
Page 21
AT-MC300 Series Installation Guide

Planning the Installation

Please refer to the following guidelines when planning the installation.
Both end nodes that will be connected to the two ports on the media converter must operate at 100 Mbps.
Both end nodes must operate in the same duplex mode, either half­duplex or full-duplex, or they must be able to auto-negotiate the duplex mode.
The end node for the 100Base-TX twisted pair port can be a workstation, a repeater, or a switch.
The end node for the 100Base-FX fiber optic port can be a workstation, a repeater, a switch, or another AT-MC300 Series Media Converter.
Refer to Table 3 for the cabling specifications for the 100Base-TX twisted pair port.
Table 3
Model Connector Cable Maximum Distance
Twisted Pair Cabling Specifications
All models RJ-45 Unshielded/Shielded Twisted Pair
Category 5 or better
Refer to Table 4 for the cabling specifications for the 100Base-FX fiber optic port when operating in full-duplex mode.
Table 4
Model Cable Maximum Distance
All models 50/125 micron multimode
fiber optic cable
All models 62.5/125 micron
multimode fiber optic cable
Refer to Table 5 for the cabling specifications for the 100Base-FX fiber optic port when operating in half-duplex mode.
Fiber Optic Port Cabling Specifications - Full-duplex
2 km (1.24 mi) 13.dB @ 1310 nm
2 km (1.24 mi) 16.8 dB @ 1310 nm
100 m (328 ft)
Maximum Allowable Loss Budget
11
Page 22
Table 5
Fiber Optic Port Cabling Specifications - Half-duplex
Model Cable Maximum Distance
All models 50/125 or 62.5/125
micron multimode fiber optic cable
The total distance of all fiber runs cannot exceed the following limits:
1
With one Media Converter inline: Switch to Switch = 372 m (1221 ft) Workstation to Switch = 372 m (1221 ft) Switch to Class II Repeater = 185 m (607 ft) Switch to Class I Repeater = 137 m (450 ft)
With two Media Converters inline: Switch to Switch = 332 m (1089 ft) Workstation to Switch = 332 m (1089 ft) Switch to Class II Repeater =145 m (476 ft) Switch to Class I Repeater = 97 m (318 ft)
1. Each media converter used inline within a single collision domain will reduce the overall segment length by 40 meters (131.24 feet) of fiber.
Note
For additional technical information on the media converter’s fiber optic port, refer to “Technical Specifications” on page 18.
12
Page 23
AT-MC300 Series Installation Guide

Installing the Unit

This section contains the procedure for installing the media converter.
If you are building a back-to-back topology, please observe the following:
During installation, setup, and testing of back-to-back media converters, make sure each media converter is in the Link Test mode.
When two media converters are connected back-to-back with no UTP/ STP cables connected and when the M/L ON/LNK TST button is in the Link Test mode position (OUT), the fiber REC LEDs on each converter may flash. This is normal and will not affect the normal operation of the converters.
To install the media converter in either a standalone or back-to-back topology, perform the following steps:
1. Remove all equipment from the package and store the packaging in a safe place.
2. If you are installing the media converter on a desktop, attach the four rubber feet to the base of the unit, placing one rubber foot in each corner. (Do not attach the four rubber feet if you are installing the media converter in an AT-MCR12 chassis.)
3. Set the M/L ON/LNK TST button to the Link Test mode (OUT) position.
4. Set the Auto-negotiation (A/N) button to either activate or deactivate auto-negotiation of the duplex mode on the unit. For information on this button, refer to “Auto-negotiation Button” on page 5.
5. If you are installing the unit in an AT-MCR12 chassis, refer to the instructions included with the chassis for directions on how to insert the media converter into the unit.
6. Plug the AC/DC power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle located on the rear panel. (This step does not apply if you installed the media converter in an AT-MCR chassis.)
13
Page 24
12VDC
Figure 7
12 V DC Receptacle on Rear Panel
7. Verify that the PWR LED lights green.
8. Set the MDI/MDI-X button for the 100Base-TX twisted pair port to the appropriate setting, as follows:
If the twisted pair port on the media converter will be connected to an MDI port on an end node (such as on a workstation or server), set the button to the
If the twisted pair port on the media converter will be connected to an
MDI-X
position. (MDI-X is the default position.)
MDI-X port on an end node (such as on a hub, switch, or another media converter), set the switch to the
MDI
position.
9. Connect a Category 5 or better twisted pair cable to the RJ-45 connector on the media converter. Connect the other end of the twisted pair cable to the desired end node.
10. Remove the dust cover from the fiber optic port.
11. Connect the fiber cable to the fiber optic connector on the media converter. Connect the other end of the cable to the desired end node.
12. Go to the next procedure, “Verifying the Installation”.
14
Page 25
AT-MC300 Series Installation Guide

Verifying the Installation

To verify the installation and check to be sure that the media converter is operating properly, perform the following procedure:
1. If you have not already, set M/L ON/LNK TST button to the Link Test mode (OUT) position. If you installed a back-to-back topology, set both media converters to the Link Test mode.
2. Power on the end nodes that are connected to the ports on the media converter.
3. Verify that the LNK (Link) LED for the twisted pair port is ON.
4. Verify that the LNK (Link) LED for the fiber optic port is ON.
Note
If either LNK LED is OFF, refer to the next section, “Troubleshooting” for guidelines on how to troubleshoot the unit.
5. Set the M/L ON/LNK TST button to the Link Test mode (OUT) position.
Note
When operating two media converters in a back-to-back configuration, Allied Telesyn recommends that the MissingLink feature on one or both of the converters be disabled. The MissingLink feature can be disabled by placing the LNK TST button in the OUT position (LNK TST Mode). The Link Test mode does not interfere with the converter’s ability to pass network traffic.
The media converter is now ready to support network operations.
15
Page 26

Troubleshooting

This section contains guidelines for troubleshooting the media converter. If a problem occurs, set the M/L ON/LNK TST button to the Link Test mode (OUT) position and then follow the instructions in this section.
If the PWR LED is OFF, verify the following:
The power cord is securely connected to the power supply on the rear panel of the media converter and to the power outlet.
The power outlet has power. If necessary, test the power outlet by connecting another device to it.
The input power source is within the acceptable range for your area.
If the LNK LED for the fiber optic port is OFF, verify the following:
The node connected to the port is powered ON.
The fiber optic cable is securely and properly connected to the fiber optic port. (The near end node transmitter (TX) cable should be connected to the far end node receiver (RX) and vice versa.)
The node connected to the fiber optic port is operating at 100 Mbps.
The correct type of fiber optic cabling is being used to connect the end node to the media converter (refer to Table 4 on page 11).
The maximum allowable operating distance has not been exceeded. (Refer to Table 4 and Table 5 on page 12.)
The maximum allowable loss budget on the fiber optic cable is within acceptable limits for full-duplex operation. (Refer to Table 4 on page
11.)
Note
In a back-to-back configuration where two media converters have been interconnected via their fiber optic ports and the units are not in Link Test mode, the LNK LEDs for the fiber optic ports will be OFF if the connection to either end node (such as a switch or hub) is lost.
16
Page 27
AT-MC300 Series Installation Guide
If the LNK LED for the twisted pair port is OFF, verify the following:
The node connected to the port is powered ON.
The twisted pair cable is securely connected to both the port on the media converter and the end node.
The MDI/MDI-X button is set to the correct position.
Category 5 or better twisted pair cabling is being used to connect the end node to the media converter.
The maximum operating distance of 100 meters (328 feet) has not been exceeded.
If the LNK LEDs are lit but there is communication problem between the end nodes connected to the media converter, verify the following:
Both end nodes are operating at 100 Mbps.
Both end nodes are operating with the same duplex mode. If necessary, use the Auto-Negotiation (A/N) button to deactivate auto­negotiation on the media converter. (Refer to “Auto-negotiation Button” on page 5 for a description of the button.)
Note
Changing the A/N button setting requires that you power OFF and power ON the media converter to activate the change on the unit.
The correct type of fiber optic cabling and twisted pair cabling is being used to connect the end nodes to the media converter.
The maximum allowable loss budget on the fiber optic cable is within acceptable limits for full-duplex operation. (Refer to Table 4 on page
11.)
17
Page 28

Technical Specifications

Table 6 lists the technical specifications for the media converter.
Table 6
Specifications
Dimensions (W x D x H) 4.125 in x 3.75 in x 1.0 in
Maximum Operating Temperature 0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature -20° C to 80° C (-4° F to 176° F)
Operating Altitude up to 3,048 m (10,000 ft)
Humidity 5% to 80% (non-condensing)
EMI/RFI meets FCC Class A, EN55022 Class A
Safety EN60825
Immunity EN50082-1 Immunity Standard
Power:
Input Supply Voltage Maximum Current Power Consumption
Table 7 and Table 8 list the technical specifications for the fiber optic port using either 50/125 or 62.5/125 micron multimode fiber optic cable.
Technical Specifications
(10.5 cm x 9.5 cm x 2.5 cm)
EN60950
±
12 V DC 500 mA 6 W
5%
Cable Type
50/125 micron
62.5/125 micron
18
Table 7
Max. Avg. Min.
-14.0 -20.3 -22.5 -31.8 -34.5 -14.0
-14.0 -16.8 -19.0 -31.8 -34.5 -14.0
Fiber Optic Port Launch Power and Receive Power
Launch Power (dBm) Receive Power (dBm)
Minimum Sensitivity
Typical Sensitivity
Saturation
Page 29
AT-MC300 Series Installation Guide
Table 8
Cable Type Optical Frequency
50/125 micron 1310 nm 13 dB 18.70 dB
62.5/125 micron 1310 nm 16.80 dB 22.50 dB
Fiber Optic Datalink
Minimum Power/ Link Budget
Average Signal Loss

Warranty Registration

When you have finished installing the product, you should register the product by completing the enclosed warranty card and sending it in. You can also visit our web site at and fill out the registration online.
www.alliedtelesyn.com/forms/warranty.htm
19
Page 30
Page 31

Appendix A

Translated Safety and Emission Information

Important
safety statements in this guide.
Wichtig
enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt
sikkerhedsadvarslerne i denne håndbog.
Belangrijk
veiligheidsopmerkingen in deze gids.
Important
instructions de sécurité figurant dans ce guide.
Tärkeää
kielellä.
Importante
sicurezza di questa guida.
Viktig
sikkerhetsinformasjonen i denne veiledningen.
Importante
de segurança neste guia.
Importante
mensajes de seguridad incluidos en esta guía.
: This appendix contains multiple-language translations for the
: Dieser Anhang enthält Übersetzungen der in diesem Handbuch
: Dette tillæg indeholder oversættelser i flere sprog af
: Deze appendix bevat vertalingen in meerdere talen van de
: Cette annexe contient la traduction en plusieurs langues des
: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla
: questa appendice contiene traduzioni in più lingue degli avvisi di
: Dette tillegget inneholder oversettelser til flere språk av
: Este anexo contém traduções em vários idiomas das advertências
: Este apéndice contiene traducciones en múltiples idiomas de los
Obs!
Denna bilaga innehåller flerspråkiga översättningar av
säkerhetsmeddelandena i denna handledning.
21
Page 32
Standards
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
: This product meets the following standards.
U.S. Federal Communications Commission
Industry Canada
!
!
!
!
!
!
!
!
!
!
!
!
1
2
3
4
5
6
7
8
9
10
11
12
RFI Emission EN55022 Class A
WARNING
which case the user may be required to take adequate measures.
Immunity
Electrical Safety
Laser
SAFETY
WARNING:
WARNING
ELECTRICAL NOTICES WARNING:
To prevent ELECTRIC shock , do not remove the cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables.
LIGHTNING DANGER DANGER:
LIGHTNING ACTIVITY.
CAUTION:
ENERGIZE EQUIPMENT, disconnect the power cord.
PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible.
CAUTION:
ambient air for cooling.
: In a domestic environment this product may cause radio interference in
EN50082-1 1997
TUV-EN60950, UL1950, CSA 950
EN60825
Class 1 Laser product.
: Do not stare into the laser beam.
ELECTRIC SHOCK HAZAR
DO NOT WORK on equipment or CABLES during periods of
POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-
Air vents must not be blocked and must have free access to the room
D
22
Page 33
AT-MC300 Series Installation Guide
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
OPERATING TEMPERATURE:
temperature of 40° degrees C.
ALL COUNTRIES:
Codes.
Normen
: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
Hochfrequenzstörung EN55022 Klasse A
WARNUNG
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Störsicherheit EN50082-1 1997
Elektrische Sicherheit EN60950, UL1950, CSA 950
Laser
SICHERHEIT
WARNUNG:
WARNUNG:
ACHTUNG:
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
GEFAHR DURCH BLITZSCHLAG GEFAHR:
ausführen.
VORSICHT:
STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DE STECKDOSE ZIEHEN.
STECKBARES GERÄT: Die Anschlußbuchse sollte in der Nähe der Einrichtung angebracht werden und leicht zugänglich sein."
VORSICHT
Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang zur Raumluft haben.
BETRIEBSTEMPERATUR:
Umgebungstemperatur von nicht mehr als 40° C entworfen.
ALLE LÄNDER:
Vorschriften entsprechen.
Install product in accordance with local and National Electrical
: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
Laserprodukt der Klasse 1.
Nicht direkt in den Strahl blicken.
GEFÄHRLICHE SPANNUNG
Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
DAS NETZKABEL DIENT ZUM TRENNEN DE
Installation muß örtlichen und nationalen elektrischen
This product is designed for a maximum ambient
EN60825
Dieses Produkt wurde für den Betrieb in einer
23
Page 34
!
!
!
!
!
!
Standarder
1
2
3
4
5
6
Radiofrekvens forstyrrelsesemission EN55022 Klasse A
ADVARSEL
Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Immunitet EN50082-1 1997
Elektrisk sikkerhed EN60950, UL1950, CSA 950
Laser
SIKKERHED
ADVARSEL
: Dette produkt tilfredsstiller de følgende standarder.
: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
EN60825
Laserprodukt av klasse 1.
!
!
!
!
!
!
!
!
7
8
9
10
11
12
13
14
ADVARSEL
ELEKTRISKE FORHOLDSREGLER ADVARSEL:
For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
FARE UNDER UVEJR FARE:
LYNAKTIVITET.
ADVARSEL:
STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen ud af stikket.
UDSTYR TIL STIKKONTAKT, stikkontakten bør installeres nær ved udstyret og skal være lettilgængelig.
ADVARSEL:
omgivende luft i rummet for afkøling.
BETJENINGSTEMPERATUR:
temperatur på maksimum 40 grader C.
ALLE LANDE:
national lovgivning for elektriske installationer.
Stirr ikke på strålen.
RISIKO FOR ELEKTRISK STØD
UNDLAD at arbejde på udstyr eller KABLER i perioder med
DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE
Ventilationsåbninger må ikke blokeres og skal have fri adgang til den
Dette apparat er konstrueret til en omgivende
Installation af produktet skal ske i overensstemmelse med lokal og
24
Page 35
!
!
!
!
!
!
AT-MC300 Series Installation Guide
Eisen
: Dit product voldoet aan de volgende eisen.
1
2
3
4
5
6
RFI Emissie EN55022 Klasse A
WAARSCHUWING
geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Immuniteit EN50082-1 1997
Electrische Veiligheid EN60950, UL1950, CSA 950
Laser
VEILIGHEID
WAARSHUWING
: Binnenshuis kan dit product radiostoring veroorzaken, in welk
EN60825
Klasse-1 laser produkt.
!
!
!
!
!
!
!
!
7
8
9
10
11
12
13
14
WAARCHUWING
WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT WAARSCHUWING:
Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden. Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus. Om het gevaar op ELEKTRISCHE SCHOKKEN te vermijden, moet u het toestel van de stroombron ontkoppelen alvorens de LAN-kabels te koppelen of ontkoppelen.
GEVAAR VOOR BLIKSEMINSLAG GEVAAR:
WAARSCHUWING:
STROOMKABEL TE ONTKOPPELEN.OM HET TOESTEL STROOMLOOS TE MAKEN: de stroomkabel ontkoppelen.
AAN TE SLUITEN APPARATUUR, de contactdoos wordt in de nabijheid van de apparatuur geïnstalleerd en is gemakkelijk te bereiken."
OPGELET:
omgevingslucht ongehinderd toelaten voor afkoeling.
BEDRIJFSTEMPERATUUR:
niet meer bedragen dan 40 graden Celsius.
ALLE LANDEN:
elektrische voorschriften.
Neit in de straal staren.
GEVAAR VOOR ELEKTRISCHE SCHOKKEN
NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
HET TOESTEL WORDT UITGESCHAKELD DOOR DE
De ventilatiegaten mogen niet worden gesperd en moeten de
De omgevingstemperatuur voor dit produkt mag
het toestel installeren overeenkomstig de lokale en nationale
25
Page 36
!
!
!
!
!
!
Normes:
ce produit est conforme aux normes de suivantes.
1
2
3
4
5
6
Emission d’interférences radioélectriques EN55022 Classe
MISE EN GARDE
des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
Immunité EN50082 - 1 1997
Sécurité électrique EN60950, UL1950, CSA 950
Laser
SÉCURITÉ.
ATTENTION
: dans un environnement domestique, ce produit peut provoquer
EN60825
Producit laser di classe 1.
A
!
!
!
!
!
!
!
!
7
8
9
10
11
12
13
14
ATTENTION
INFORMATION SUR LES RISQUES ÉLECTRIQUES AVERTISSEMENT
Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement protecteur du matériel. Ce matériel ne contient aucun élément réparable par l’utilisateur. Il comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ÉLECTROCUTION, débrancher le matériel avant de connecter ou de déconnecter les câbles LAN.
DANGER DE FOUDRE DANGER:
ATTENTION:
POUR COUPER L’ALIMENTATION DU MATÉRIEL, débrancher le cordon.
EQUIPEMENT POUR BRANCHEMENT ELECTRIQUE, la prise de sortie doit être placée près de l’équipement et facilement accessible".
ATTENTION:
de circuler librement pour le refroidissement.
TEMPÉRATURE DE FONCTIONNEMENT:
une température ambiante maximum de ou 40 degrés Celsius.
POUR TOUS PAYS:
nationales et locales.
Ne pas fixer le faisceau des yeux.
: DANGER D’ÉLECTROCUTION
NE PAS MANIER le matériel ou les CÂBLES lors d’activité orageuse.
LE CORDON D’ALIMENTATION SERT DE MISE HORS CIRCUIT.
Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant
Ce matériel est capable de tolérer
Installer le matériel conformément aux normes électriques
26
Page 37
AT-MC300 Series Installation Guide
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Standardit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Radioaaltojen häirintä EN55022 Luokka A
VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Kestävyys EN50082-1 1997
Sähköturvallisuus EN60950, UL1950, CSA 950
Laser
TURVALLISUUS
VAROITUS
VARIOTUS
SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA VAROITUS:
Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
SALAMANISKUVAARA HENGENVAARA:
SALAMOINNIN AIKANA.
HUOMAUTUS:
VIRTA KATKAISTAAN irrottamalla virtajohto.
PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle ja siihen on oltava esteetön pääsy."
HUOMAUTUS:
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
KÄYTTÖLÄMPÖTILA:
maksimilämpötilalle 40°C.
KAIKKI MAAT:
sähköturvallisuusmääräysten mukaisesti.
: Tämä tuote on seuraavien standardien mukainen.
EN60825
Luokan 1 Lasertuote.
Älä katso säteeseen.
SÄHKÖISKUVAARA
ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
Tämä tuote on suunniteltu ympäröivän ilman
Asenna tuote paikallisten ja kansallisten
27
Page 38
!
!
!
!
!
!
Standard
1
2
3
4
5
6
Emissione RFI (interferenza di radiofrequenza) EN55022 Classe
AVVERTENZA:
interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
Immunità EN50082-1 1997
Sicurezza elettrica EN60950, UL1950, CSA 950
Laser
NORME DI SICUREZZA
AVVERTENZA
: Questo prodotto è conforme ai seguenti standard.
A
in ambiente domestico questo prodotto potrebbe causare radio
EN60825
Prodotto laser di Classe 1.
!
!
!
!
!
!
!
!
7
8
9
10
11
12
13
14
AVERTENZA
AVVERTENZE ELETTRICHE ATTENZIONE:
Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato. Per evitare ogni possibilità di SCOSSE ELETTRICHE, interrompere l’alimentazione del dispositivo prima di collegare o staccare i cavi LAN.
PERICOLO DI FULMINI PERICOLO:
PRECIPITAZIONI TEMPORALESCHE.
ATTENZIONE:
DI DISATTIVAZIONE. PER TOGLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione.
APPARECCHIATURA COLLEGABILE, la presa va installata vicino all’apparecchio per risultare facilmente accessibile".
ATTENZIONE:
ricircolo dell’aria ambiente per il raffreddamento.
TEMPERATURA DI FUNZIONAMENTO:
temperatura ambientale massima di 40 gradi centigradi.
TUTTI I PAESI:
elettriche nazionali.
Non fissare il raggio con gli occhi.
PERICOLO DI SCOSSE ELETTRICHE
NON LAVORARE sul dispositivo o sui CAVI durante
IL CAVO DI ALIMENTAZIONE È USATO COME DISPOSITIVO
le prese d’aria non vanno ostruite e devono consentire il libero
Questo prodotto è concepito per una
installare il prodotto in conformità delle vigenti normative
28
Page 39
AT-MC300 Series Installation Guide
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Sikkerhetsnormer
1
2
3
4
5
6
7
8
9
10
11
12
13
14
RFI stråling EN55022 Klasse A
ADVARSEL
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Immunitet EN50082-1 1997
Elektrisk sikkerhet EN60950, UL1950, CSA 950
Laser
SIKKERHET
ADVARSEL
ADVARSAL
ELEKTRISITET ADVARSEL:
For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen deler som brukeren kan reparere på innsiden. Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig kvalifisert tekniker. For å unngå ELEKTRISK SJOKK må den elektriske strømmen til produktet være avslått før LAN-kablene til- eller frakobles.
FARE FOR LYNNEDSLAG FARE:
ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
FORSIKTIG:
FOR Å DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
UTSTYR FOR STIKKONTAKT. Stikkontakten skal monteres i nærheten av utstyret og skal være lett tilgjengelig."
FORSIKTIG:
romtemperatur for avkjøling.
DRIFTSTEMPERATUR:
romtemperatur på 40 grader celsius.
ALLE LAND:
elektriske koder.
: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
EN60825
Laserprodukt av klasse 1.
Stirr ikke på strålen.
FARE FOR ELEKTRISK SJOKK
STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET.
Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med
Dette produktet er konstruert for bruk i maksimum
Produktet må installeres i samsvar med de lokale og nasjonale
29
Page 40
!
!
!
!
!
!
Padrões
: Este produto atende aos seguintes padrões.
1
2
3
4
5
6
Emissão de interferência de radiofrequência EN55022 Classe
AVISO
: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Imunidade EN50082-1 1997
Segurança Eléctrica EN60950, UL1950, CSA 950
Laser
SEGURANÇA
AVISO
Produto laser de classe 1.
EN60825
A
!
!
!
!
!
!
!
!
AVISO
7
8
9
10
11
12
13
14
Não olhe fixamente para o raio.
AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS ATENÇÃO:
Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN.
PERIGO DE CHOQUE CAUSADO POR RAIO PERIGO:
suscetíveis a QUEDAS DE RAIO.
CUIDADO:
DISPOSITIVO DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo de ALIMENTAÇÃO.
EQUIPAMENTO DE LIGAÇÃO, a tomada eléctrica deve estar instalada perto do equipamento e ser de fácil acesso."
CUIDADO:
livre ao ar ambiente para arrefecimento adequado do aparelho.
TEMPERATURA DE FUNCIONAMENTO:
temperatura ambiente máxima de 40 graus centígrados.
TODOS OS PAÍSES:
para instalações elétricas.
PERIGO DE CHOQUE ELÉTRICO
NÃO TRABALHE no equipamento ou nos CABOS durante períodos
O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM
As aberturas de ventilação não devem ser bloqueadas e devem ter acesso
Este produto foi projetado para uma
Instale o produto de acordo com as normas nacionais e locais
30
Page 41
AT-MC300 Series Installation Guide
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Estándares:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Emisión RFI EN55022 Clase
ADVERTENCIA
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Inmunidad EN50082-1 1997
Seguridad eléctrica EN60950, UL1950, CSA 950
Laser
SEGURIDAD
¡ADVERTENCIA!
¡ADVERTENCIA!
AVISOS ELECTRICOS ADVERTENCIA:
Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado. Para evitar la posibilidad de ELECTROCHOQUE desconecte la corriente eléctrica que llega al producto antes de conectar o desconectar los cables LAN.
PELIGRO DE RAYOS PELIGRO:
equipos o en LOS CABLES durante TORMENTAS ELECTRICAS.
ATENCION:
DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte el cable de alimentación.
EQUIPO CONECTABLE, el tomacorriente se debe instalar cerca del equipo, en un lugar con acceso fácil".
ATENCION:
acceso libre al aire ambiental de la sala para su enfriamiento.
TEMPERATURA REQUERIDA PARA LA OPERACIÓN:
diseñado para una temperatura ambiental máxima de 40 grados C.
PARA TODOS LOS PAÍSES:
Eléctricos locales y nacionales.
Este producto cumple con los siguientes estándares.
A
: en un entorno doméstico, este producto puede causar
EN60825
Producto láser Clase 1.
No mirat fijamente el haz.
PELIGRO DE ELECTROCHOQUE
NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los
EL CABLE DE ALIMENTACION SE USA COMO UN DISPOSITIVO
Las aberturas para ventilación no deberán bloquearse y deberán tener
Este producto está
Monte el producto de acuerdo con los Códigos
31
Page 42
!
!
!
!
!
!
Standarder:
1
2
3
4
5
6
Radiostörning EN55022 Klass A
VARNING
tvinga användaren till att vidtaga erforderliga åtgärder.
Immunitet EN50082-1 1997
Elsäkerhet EN60950, UL1950, CSA 950
Laser
SÄKERHET
VARNING!
Denna produkt uppfyller följande standarder.
: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
EN60825
Laserprodukt av klass 1.
!
!
!
!
!
!
!
!
7
8
9
10
11
12
13
14
VARNING!
TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK:
RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LAN­kablarna ansluts eller kopplas ur.
FARA FÖR BLIXTNEDSLAG FARA:
VARNING:
FRÅN STRÖMMEN, dra ur nätkabeln.
UTRUSTNING MED PLUGG. Uttaget skall installeras i utrustningens närhet och vara lättåtkomligt".
VARNING:
rumsluft för avsvalning.
DRIFTSTEMPERATUR:
överstigande 40 grader Celsius.
ALLA LÄNDER:
bestämmelser för elektrisk utrustning.
Laserstrålning när enheten är öppen.
ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
NÄTKABELN ANVÄNDS SOM STRÖMBRYTARE FÖR ATT KOPPLA
Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande
Denna produkt är konstruerad för rumstemperatur ej
Installera produkten i enlighet med lokala och statliga
32
Page 43

Appendix B

Technical Support Fax Order

Name __________________________________________________________________
Company _______________________________________________________________
Address ________________________________________________________________
City ________________________ State/Province_______________________________
Zip/Postal Code ____________________ Country_______________________________
Phone _______________________________ Fax _______________________________

Incident Summary

Allied Telesyn model number ________________________________________________
Firmware release number of Allied Telesyn product (if applicable)____________________
Other network software products I am using (e.g., network managers)
______________________________________________________________________
______________________________________________________________________
Brief summary of problem __________________________________________________
______________________________________________________________________
Conditions (List the steps that led up to the problem.)_____________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
Detailed description (Please use separate sheet)
Please also fax printouts of relevant files such as batch files and configuration files. When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page viii.
33
Page 44
Page 45

Appendix C

AT-MC300 Series Installation Guide Feedback

Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
I found the following the most valuable __________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
I would like the following more developed ________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
I would find this guide more useful if ____________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
Please fax or mail your feedback. Fax to 1-408-736-0100. Or mail to:
Allied Telesyn International, Corp. c/o Technical Communications
960 Stewart Drive, Suite B Sunnyvale, CA 94085 USA
PN 613-10762-00 Rev C
35
Page 46
Loading...