Allied Telesis AT-LMC10ST User Manual

Page 1
AT-LMC10SC AT-LMC10ST
Ethernet Media Converters
Installation Guide
PN 613-50451-00 Rev B
Page 2
Copyright © 2004 Allied Telesyn, Inc. 960 Stewart Drive, Suite B, Sunnyvale, CA 94085, USA
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn, Inc. has been advised of, known, or should have known, the possibility of such damages.
Page 3

Electrical Safety and Emission Compliance

Standards: This product meets the following standards.
U.S. Federal Communications Commission
Declaration Of Conformity
Manufacturer Name: Allied Telesyn, Inc. Manufacturer Address: 960 Stewart Drive, Suite B
Manufacturer Telephone: 408-730-0950 Declares that the Product: Ethernet Media Converters Model Numbers: AT-LMC10SC
This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on; the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission rules.
Sunnyvale, CA 94085 USA
AT-LMC10ST
Warning: This product requires only Category 3, 4, or 5 shielded twisted­pair cable for all 10 Mbps RJ-45 connections, and Category 5 shielded twisted-pair for all 100 Mbps RJ-45 connections to comply with Class B emission limits. If not used with shielded cables, this product may cause radio interference in which case the user may be required to take adequate measures to reduce interference levels.
iii
Page 4
Electrical Safety and Emission Compliance
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Industry Canada
RFI Emission EN55022 Class B Immunity EN55024 Warning: This product requires shielded cables to comply with emission and
immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
Electrical Safety EN60950 (TUV), UL1950, ( Laser EN60825
Power to the hub must be sourced only from the adapter.
USA/Canada
Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA.
Europe - EU
Use TÜV licensed AC adapter of DC 12V, 500mA.
UK
Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA. Important: Appendix A contains translated safety statements for installing
this equipment. When you see the , go to Appendix A for the translated safety statement in your language.
Wichtig: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af dette udstyr. Når De ser symbolet finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van deze apparatuur. Wanneer u de voor vertaalde veiligheidsinstructies in uw taal.
Important: L'annexe A contient les instructions de sécurité relatives à l'installation de cet équipement. Lorsque vous voyez le symbole vous à l'annexe A pour consulter la traduction de ces instructions dans votre langue.
Tärkeää: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet
Importante: l’Appendice A contiene avvisi di sicurezza tradotti per l’installazione di questa apparecchiatura. Il simbolo , indica di consultare l’Appendice A per l’avviso di sicurezza nella propria lingua.
Viktig: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser sikkerhetsinformasjonen på ønsket språk.
3
sehen, schlagen Sie in Anhang A den
-symbolin, katso käännettyä turvaohjetta liitteestä A.
, åpner du til Tillegg A for å finne den oversatte
2
5
, skal De slå op i tillæg A og
ziet, raadpleeg Appendix A
1
10
) 4
cULus
, reportez-
iv
Page 5
AT-LMC10SC and AT-LMC10ST Installation Guide
Importante: O Anexo A contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo
, leia a advertência de
segurança traduzida no seu idioma no Anexo A. Importante: El Apéndice A contiene mensajes de seguridad traducidos para
la instalación de este equipo. Cuando vea el símbolo
, vaya al Apéndice A para
ver el mensaje de seguridad traducido a su idioma. Obs! Bilaga A innehåller översatta säkerhetsmeddelanden avseende
installationen av denna utrustning. När du ser
, skall du gå till Bilaga A för
att läsa det översatta säkerhetsmeddelandet på ditt språk.
v
Page 6
Page 7

Table of Contents

Electrical Safety and Emission Compliance............................................iii
Table of Contents ..........................................................................................vii
Welcome to Allied Telesyn ...........................................................................ix
Where to Find Web-based Guides ....................................................................ix
Document Conventions .....................................................................................ix
Contacting Allied Telesyn .................................................................................. x
Online Support ............................................................................................ x
E-mail and Telephone Support................................................................... x
Returning Products ..................................................................................... x
For Sales or Corporate Information ...........................................................x
Chapter 1
Overview ........................................................................................................... 1
Key Features.......................................................................................................3
Status LEDs ................................................................................................ 3
MDI/MDI-X Selector Switch.......................................................................3
External AC/DC Power Adapter................................................................. 4
Network Topologies ............................................................................................5
Standalone Topology ...................................................................................5
Back-to-Back Topology................................................................................6
Chapter 2
Installing the Media Converter ................................................................... 7
Verifying the Package Contents ........................................................................7
Planning the Installation...................................................................................7
Reviewing Safety Precautions ...........................................................................8
Installing the Media Converter .........................................................................8
Warranty Registration ..................................................................................... 11
Chapter 3
Troubleshooting ............................................................................................ 13
Troubleshooting Guidelines ............................................................................. 13
Loopback Test................................................................................................... 15
vii
Page 8
Appendix A
Technical Specifications .............................................................................17
Physical .............................................................................................................17
Environmental ..................................................................................................17
Electrical Rating...............................................................................................17
Agency Certifications........................................................................................18
Fiber Optic Port Specifications ........................................................................18
Appendix B
Translated Electrical Safety and Emission Information..................... 21
viii
Page 9

Welcome to Allied Telesyn

This guide contains instructions on how to install an AT-LMC10SC or an AT-LMC10ST Fast Ethernet Media Converter.

Where to Find Web-based Guides

The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, select “Support & Services” from our web site.

Document Conventions

This guide uses the following conventions:
Note
Notes provide additional information.
Caution
Cautions indicate that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
Warnings indicate that performing or omitting a specific action may result in bodily injury.
ix
Page 10
Welcome to Allied Telesyn

Contacting Allied Telesyn

This section provides Allied Telesyn contact information for technical support as well as sales or corporate information.

Online Support

You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.

E-mail and Telephone Support

For Technical Support via E-mail or telephone, refer to the Support & Services section of the Allied Telesyn web site: http://www.alliedtelesyn.com.

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
To obtain a RMA number, contact Allied Telesyn’s Technical Support at our web site: http://www.alliedtelesyn.com.

For Sales or Corporate Information

You can contact Allied Telesyn for sales or corporate information at our web site: http://www.alliedtelesyn.com. To find the contact information for your country, select “Contact Us” then “Worldwide Contacts.”
x
Page 11

Chapter 1

Overview

The AT-LMC10 Series Ethernet Media Converters include the following models:
AT-LMC10SC
AT-LMC10ST
The AT-LMC10 Series Ethernet Media Converters are designed to extend the distance of your network by interconnecting LAN devices that are physically separated by large distances. These media converters have the functionality to connect any managed/unmanaged 10Mbps switch or hub using standard 10Base-T RJ-45 connections and convert the signal to 10Base-FL fiber.
Each AT-LMC10 Series media converter features a 10Base-T twisted pair port and a 10Base-FL fiber optic port. The twisted pair port has an RJ-45 connector and a maximum operating distance of 100 meters (328 feet). The fiber optic port has a multi-mode ST or SC connector and a maximum operating distance of 2 kilometers (1.2 miles). These units operate at 10 Mbps and feature half- and full-duplex operation.
The media converters can be installed on a desktop or in an AT-MCR12 chassis. The AT-LMC10 Series Media Converters are easy to install and do not require any software configuration or management. Figure 1 and Figure 2 display the front panel of the AT-LMC10 Series Media Converters.
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
TX RX
AT-LMC10SC ETHERNET MEDIA CONVERTER
10Base-FL 10Base-T
REC
LNK
REC
PWR
MDI-XMDI
LNK
Figure 1 AT-LMC10SC Model Converter - Front Panel
1
Page 12
Overview
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
TX RX
AT-LMC10ST ETHERNET MEDIA CONVERTER
10Base-FL 10Base-T
REC
LNK
REC
PWR
MDI-XMDI
LNK
Figure 2 AT-LMC10ST Model Converter - Front Panel
Figure 3 displays the rear panel of the AT-LMC10 Series Media Converters.
12 VD C
Figure 3 AT-LMC10 Series Converters - Rear Panel
Table 1 lists the maximum operating distances for the media converters.
Table 1 Maximum Operating Distances
Model Type of Connector Maximum Operating Distance
10Base-FL 10Base-T 10Base-FL 10Base-T
AT-LMC10SC Multi-mode SC RJ-45 2 km
AT-LMC10ST Multi-mode ST RJ-45 2 km
2
100 m (328 ft)
(1.24 mi)
100 m (328 ft)
(1.24 mi)
Page 13
AT-LMC10SC and AT-LMC10ST Installation Guide

Key Features

The media converters have the following key features:
LEDs for unit and port status
MDI/MDI-X selector switch on RJ-45 port
Automatic half- or full-duplex mode operation with 10Base-T or
10Base-FL fiber optic port
Maximum transmission distance of fiber connection is 2 kilometers at
full-duplex mode
External AC/DC power adapter
Standard size for use in an AT-MCR12 chassis

Status LEDs

Table 2 defines the media converter’s LEDs.
Table 2 Status LEDs
LED State Color Description
PWR ON Green Power is applied to the media converter.
REC ON Green Data is received on the port.
LNK ON Green A link has been established on the port.

MDI/MDI-X Selector Switch

An RJ-45 port on a 10 Mbps Ethernet network device can have one of two possible wiring configurations: MDI or MDI-X. The RJ-45 port on a PC, router or bridge is typically wired as MDI, while the twisted pair port on a switch or hub is usually MDI-X.
To connect two 10 Mbps network devices together that have dissimilar port wiring configurations, such as MDI to MDI-X, you use a straight-through cable. To connect two network devices that have an RJ-45 port with the same wiring configuration, such as MDI to MDI, you use a crossover cable.
The RJ-45 port on the media converter features an MDI/MDI-X switch. You can use this switch to configure the twisted pair port on the media converter as either MDI or MDI-X. This feature allows you to use a straight-through cable regardless of the type of end-node connected to the port.
3
Page 14
Overview
Note
After using the MDI/MDI-X switch to change between the two settings, you must reset the media converter by powering OFF then powering ON the unit.

External AC/DC Power Adapter

An external AC/DC power adapter is included with the media converter for standalone operation. The power adapter supplies 12VDC to the media converter. Allied Telesyn supplies an approved safety compliant AC power adapter for the 120 or 240V AC versions with an unregulated output of 12VDC at 1 A. The power required for the media converter is 12VDC, 500 mA.
4
Page 15
AT-LMC10SC and AT-LMC10ST Installation Guide

Network Topologies

The AT-LMC10 Series Media Converters can be used in two different types of topologies: standalone and back-to-back. Both topologies are described below.

Standalone Topology

Figure 4 illustrates a standalone topology where two AT-8224XL switches have been interconnected with an AT-LMC10SC media converter.
AT-8224XL
Cable Legend
10 Mbps
10 Mbps (Fiber)
100 m (328 ft)
X T
E­S A B
0 0
1 / T E­AS
B 0 1
H
C T I W
S T
E N R
E H T E
T S A F
1
S U
T A T S
2 3
-2 S R
T
R O P L
A IN
M
Y
R T I
E
T IV
T C A
T R O P
X
T
-
E S A B
00 / 1
-T E S A
B 0
AT-LMC10SC
TX RX
CLASS 1 LASER PRODUCT DO NOT STARE
INTO BEAM
AT-LMC10SC ETHERNET MEDIA CONVERTER
10Base-FL 10Base-T
REC
LNK
REC
PWR
LNK
MDI-XMDI
2 km (1.2 mi)
X
-T E S A
00B 1 /
T
­E
S BA 10
H C IT
W S T
E N R E
H T E
T S A F
1
S U
T A T S
2 3 2
­S R
T R O
P
L A IN M
Y
R
IT
E
T IV T
C
A T R O P
X
-T E S A
B 0
0 1 /
-T
E S
A B 0
AT-8224XL with a 10 Mbps Expansion Module
Figure 4 Standalone Topology
5
Page 16

Back-to-Back Topology

Figure 5 illustrates two media converters in a back-to-back configuration.
AT-8224XL
CLASS 1 LASER PRODUCT DO NOT STARE
INTO BEAM
AT-LMC10SC ETHERNET MEDIA CONVERTER
2 km (1.2 mi)
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
Cable Legend
10 Mbps
10 Mbps (Fiber)
AT-LMC10SC
TX RX
10Base-FL 10Base-T
REC
LNK
AT-LMC10SC
TX RX
10Base-FL 10Base-T
AT-LMC10SC ETHERNET MEDIA CONVERTER
REC
PWR
LNK
MDI-XMDI
100 m (328 ft)
REC
LNK
REC
PWR
LNK
MDI-XMDI
100 m (328 ft)
Figure 5 Back-to-Back Topology
X T
-
E S A
0B 10 /
-T
SE 0BA 1
WIT
T S NE R HE
ET T
FAS
AT-8224XL
X
T SE­A
B
00 / 1 T
E­S
A B 0
H C
1
TX E­AS
00B / 1
E-T
BAS 0 1
TCH
I SW ET
RN E TH
E
ST A F
-2 RS
IN M R
TY
TE
VI CTI A
RT
PO
ITY CTIV A
PORT
E-TX
AS
100B
-T /
E S 10BA
S
U T A T S
32
T
OR P AL
S U
T A T S
2 S-23 R
RT
L PO NA
RMI TE
Page 17

Chapter 2

Installing the Media Converter

Verifying the Package Contents

Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
One AT-LMC10SC or AT-LMC10ST Ethernet Media Converter
Four protective feet (for desktop use only)
An external AC/DC power adapter
This installation guide
Warranty card

Planning the Installation

Be sure to observe the following guidelines when planning the installation of your media converter.
The end-nodes connected to the media converter must operate at 10
Mbps.
The two end-nodes connected to the ports of the media converter must
operate with the same duplex mode, either half- or full-duplex. The media converter itself can operate in either mode.
The devices connected to the two ports on the media converter can be
a network adapter card, repeater, switch, or router.
Refer to Table 3 and Table 4 for the twisted pair and fiber optic port
specifications.
Table 3 10Base-T Twisted Pair Port Cabling Specifications
Cable Type Maximum Operating Distance
Shielded or unshielded Category 5 or better 100 m (328 ft)
7
Page 18

Installing the Media Converter

Table 4 10Base-FL Fiber Optic Port Specifications (Full-duplex)
Model Type of Fiber Optic
Cable
AT-LMC10SC
and
AT-LMC10ST
50/125 micron multi-mode
62.5/125 micron multi-mode
Maximum Operating Distance
2 km (1.2 mi) 13 dB at 1310 nm
2 km (1.2 mi) 13 dB at 1310 nm
Maximum Allowable Loss Budget

Reviewing Safety Precautions

Please review the following safety guidelines before installing the media converter.
Class 1 laser product. 6
Do not stare into the laser beam. 7
Warning Lightning Danger: Do not work on equipment or cables during periods
of lightening activity. 8
Do not block air vents. 9
Power to this product must be sourced only from the adapter. 10
Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. 11
All Countries: Install this product in accordance with local and National Electric Codes. 12
Installing the Media Converter
The following procedure explains how to install an AT-LMC10SC or an AT-LMC10ST Media Converter.
To install the media converter, perform the following procedure:
1. Remove all equipment from the package and store the packaging material in a safe place.
8
Page 19
AT-LMC10SC and AT-LMC10ST Installation Guide
Note
Do not remove the dust cover from the fiber optic port until you are ready to connect the fiber optic cable. Dust contamination can adversely impact the operating performance of the port on the media converter.
2. If you are installing the media converter in an AT-MCR12 chassis, refer to the chassis’s installation guide for instructions on how to install the unit, then proceed to Step 5.
3. Place the media converter on a flat, secure surface (such as a desk or table) leaving ample space around the unit for ventilation.
4. Attach the four protective rubber feet to the bottom of the media converter, as illustrated in Figure 6.
Note Do not attach the protective feet if you are installing the unit in an AT-MCR12 chassis.
AT-LMC10SC ETHERNET MEDIA CONVERTER
LNK
PWR
REC
MDI-XMDI
LNK
REC
10Base-FL 10Base-T
TX RX
CLASS 1
INTO BEAM
DO NOT STARE
LASER PRODUCT
Figure 6 Attaching the Protective Feet
5. Plug the AC/DC power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle located on the back of the unit. Refer to Figure 7 on page page 10.
Note
This step does not apply if you installed the unit in an AT-MCR12 chassis.
9
Page 20
Installing the Media Converter
Power Plug
AC/DC Power Adapter
DC Receptacle
12 VD C
Back of Media Converter
DC Polarity Symbols
Figure 7 12VDC Connector on Rear Panel
6. Verify that the PWR LED is green. If the LED is OFF, refer to “Troubleshooting” on page 13.
7. Remove the dust cover from the fiber optic connector and connect the cable to the fiber optic port. Verify that the media converter’s transmitter port (TX) is connected to the end-node’s receiver port (RX) and that the media converter’s receiver port (RX) is connected to the end-node’s transmitter port (TX).
8. Connect the twisted pair cable to the twisted pair port.
Note
End-nodes connected to the media converter must operate with the same duplex mode, either both full-duplex or both half-duplex.
9. Set the MDI/MDI-X switch as follows:
If you are connecting a workstation to the 10Base-T port, set the MDI/
MDI-X switch to the MDI-X position. MDI-X is the default position.
If you are connecting a hub or a switch to the 10Base-T port, set the
MDI/MDI-X switch to the MDI position.
Note
After using the MDI/MDI-X switch to change between the two settings, you must reset the media converter by powering OFF then powering ON the unit.
10. Power ON the end-nodes.
The media converter is now ready for use.
10
Page 21
AT-LMC10SC and AT-LMC10ST Installation Guide

Warranty Registration

When you finish installing the product, you should register your product by completing the enclosed warranty card and sending it in.
11
Page 22
Page 23

Chapter 3

Troubleshooting

Troubleshooting Guidelines

Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs.
If the PWR LED is OFF, do the following:
If the unit is installed on a desktop, check to be sure that the power
adapter is securely connected to a power outlet and that the power adapter cable is securely connected to the back of the media converter.
If the unit is installed in an AT-MCR12 chassis, check that the unit is
fully seated in the slot.
Verify that the power outlet has power by connecting another device
to it.
Try using another power adapter of the same type that came with your
media converter.
If the LNK LED for the twisted pair port is OFF, do the following:
Check that the end-node connected to the port is powered ON and is
operating properly.
Check that the twisted pair cable is securely connected to the twisted
pair port on the media converter and on the remote end-node.
Make sure that the twisted pair cable does not exceed 100 meters (328
feet) and that you are using Category 5 or better.
Verify that both end-nodes connected to the media converter are
operating at the same speed. Both must be operating at either 10 Mbps.
Make sure no configuration changes have been made. If so, you must
reset the media converter by powering OFF and then powering ON the unit.
13
Page 24
Troubleshooting
If the LNK LED for the fiber optic port is OFF, do the following:
Verify that then end-node connected to the port is ON and is operating
properly.
Check that the fiber optic cable is securely connected to the fiber optic
port on the media converter and on the end-node.
Verify that the end-nodes connected to the media converter are
operating at the same speed. Both must be operating at 10 Mbps.
Make sure that the cable connected to the media converter’s receiver
port (RX) is connected to the end-node’s transmitter port (TX) and that the media converter’s transmitter port (TX) is connected to the end­node’s receiver port (RX).
Make sure no configuration changes have been made. If so, you must
reset the media converter by powering OFF then powering ON the unit.
Test the attenuation on the fiber optic cable to ensure that it does not
exceed acceptable values. Refer to “Troubleshooting” on page 13 for more information.
Verify that you are using the appropriate type of fiber optic cable and
that you have not exceeded the maximum operating distance. For maximum operating distances, refer to Table 1 on page 2. For cable types, refer to “Fiber Optic Port Specifications” on page 18.
Check that the operating specifications (e.g., wavelength and
maximum operating distance) of the fiber optic port on the end-node are compatible with the operating specifications of the fiber optic port on the media converter. Refer to “Fiber Optic Port Specifications” on page 18 for more information.
If there is a communication problem between the end-nodes connected to the media converter, do the following:
Verify that both end-nodes are operating with the same duplex mode.
If you are still experiencing problems after testing and troubleshooting the installation, refer to “Contacting Allied Telesyn” on page x or visit our web site at www.alliedtelesyn.com for support information.
14
Page 25
AT-LMC10SC and AT-LMC10ST Installation Guide

Loopback Test

To check hardware reliability of the media converter, perform the following procedure:
1. Power OFF the media converter by unplugging the power adapter from the wall outlet and from the back of the unit.
2. Connect the RJ-45 twisted pair port to a 10Base port on the end-node and power ON the end-node.
3. Set the MDI/MDI-X switch as follows:
If you are connecting a workstation to the 10Base port, set the MDI/
MDI-X switch to the MDI-X position. MDI-X is the default position.
If you are connecting a hub or a switch to the 10Base port, set the MDI/
MDI-X switch to the MDI position.
4. Using a tested and good fiber patch cable, attach the matching ends of the fiber cable to the transmit (TX) and receive (RX) connectors of the media converter.
5. Power ON the media converter.
6. Verify that the LNK LED on both the twisted pair and fiber optic ports are green.
If the LEDs are green, the unit is working properly and there is a
problem elsewhere on the segment.
If the LEDs are OFF, contact Allied Telesyn Technical Support for a
RMA number to replace the unit. Refer to “Returning Products” on page x for more information. You can also find RMA information by accessing the Knowledge Base at http:\\kb.alliedtelesyn.com.
15
Page 26
Page 27

Appendix A

Technical Specifications

Physical

Dimensions: W x D x H
10.5 cm x 9.5 cm x 2.5 cm (4.125 in x 3.75 in x 1.0 in)
Weight: 0.27 kg (0.60 lbs)

Environmental

Maximum Operating Temperature: 0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature: -20° C to 60° C (-4° F to 140° F)
Operating and Storage Altitude: Up to 3,048 meters (10,000 feet)
Relative Humidity Operating
and Storage: 5% to 95% (non-condensing)

Electrical Rating

Input Supply Voltage: 12VDC ± 5%
Maximum Current: 500 mA
Power Consumption: 6W
17
Page 28
Technical Specifications

Agency Certifications

EMI/RFI: FCC Class B, EN55022 Class B,
VCCI Class B
Electrical Safety: EN60950 (TUV), UL1950 (cULus),
CE Compliant
Immunity: EN55024, VCCI Class B

Fiber Optic Port Specifications

Table 5 through Table 7 list the specifications for the 10Base-FL fiber optic port.
Table 5 Fiber Optic Transmitter
Model Fiber
Type
Fiber
1
Optic
Optical
Wavelength Diameter (microns)
AT-LMC10SC
MMF 50/125 1310 nm -14.0 -20.3 -22.5 and AT-LMC10ST
1. MMF = Multimode Fiber
2. The launch power is measured at one meter from the transmitter.
MMF 62.5/125 1310 nm -14.0 -16.8 -19.0
Table 6 Fiber Optic Receiver
Model Fiber
Type
Fiber
1
Optic
Optical
Wavelength Diameter (microns)
AT-LMC10SC and AT-LMC10ST
1. MMF = Multimode Fiber
MMF 50/125 1310 nm -31.8 -34.4 -14.0
MMF 62.5/125 1310 nm -31.8 -34.4 -14.0
Launch Power (dBm)
2
Max. Avg. Min.
Receive Power (dBm)
Min. Typical Saturation
18
Page 29
AT-LMC10SC and AT-LMC10ST Installation Guide
Table 7 Fiber Optic Datalink
Model Fiber
Type
1
Minimum Power / Link
Average Signal Loss
Minimum Distance
2
Spec.
Maximum Distance Spec.
Budget
AT-LMC10SC and AT-LMC10ST
1. MMF = Multimode Fiber
2. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far-end-node.
50/125 MMF
62.5/125 MMF
13.00 dB 18.70 dB 0 2 km (1.2 mi)
16.80 dB 22.50 dB 0 2 km (1.2 mi)
Fiber Optic Loss Specifications (Benchmarks)
Fiber Type
1
Fiber Optic Diameter (microns)
Optical Wavelength
Typical Loss Factor
Worst Case Loss Factor (dB/km)
Bandwidt h (Mhz­km)
(dB/km)
MMF 50/125 850 nm 3.00 3.50 400
50/125 1310 nm 1.00 1.50 400
62.5/125 850 nm 3.00 3.75 200
62.5/125 1310 nm 1.00 1.50 500
100/140 850 nm 4.00 4.00 100
1. MMF = Multimode Fiber
19
Page 30
Page 31

Appendix B

Translated Electrical Safety and Emission Information

Important: This appendix contains multiple-language translations for the safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvisi di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das advertências de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av säkerhetsmeddelandena i denna handledning.
21
Page 32
Translated Electrical Safety and Emission Information
Standards: This product meets the following standards.
U.S. Federal Communications Commission
Declaration Of Conformity
Manufacturer Name: Allied Telesyn, Inc. Manufacturer Address: 960 Stewart Drive, Suite B
Manufacturer Telephone: 408-730-0950 Declares that the Product: Ethernet Media Converters Model Numbers: AT-LMC10SC
This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on; the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission rules.
Warning: This product requires only Category 3, 4, or 5 shielded twisted-pair cable for all 100 Mbps RJ-45 connections, and Category 5 shielded twisted-pair for all 100 Mbps RJ-45 connections to comply with Class B emission limits. If not used with shielded cables, this product may cause radio interference in which case the user may be required to take adequate measures to reduce interference levels.
Sunnyvale, CA 94085 USA
AT-LMC10ST
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
22
Page 33
AT-LMC10SC and AT-LMC10ST Installation Guide
1RFI Emission EN55022 Class B
2 Immunity EN55024
3 Warning: This product requires shielded cables to comply with emission
and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
4 Electrical Safety EN60950 (TUV), UL1950 (
cULus
)
Safety
5Laser EN60825
6 Warning: Class 1 Laser product.
7 Warning: Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture. Use of controls or adjustments of performance or procedures other than those specified herein may result in hazardous radiation exposure.
8 Lightning Danger
Danger: Do not work on equipment or cables during periods of lightning
activity.
9 Do not block air vents
10 Power to the hub must be sourced only from the adapter.
USA/Canada
Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA.
Europe - EU
Use TÜV licensed AC adapter of DC 12V, 500mA.
UK
Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA.
11 Operating Temperature: This product is designed for a maximum
ambient temperature of 40 degrees C.
12 All Countries: Install product in accordance with local and National
Electrical Codes.
23
Page 34
Translated Electrical Safety and Emission Information
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
1 Hochfrequenzstörung EN55022 Klasse B
2 Störsicherheit EN55024
3 Achtung: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit
den Richtlinien für Emission und Interferenzschutz entsprochen wird. Falls das Produkt mit nicht abgeschirmten Kabeln verwendet wird, können weitergehende Maßnahmen für die Korrektur von Interferenzproblemen auf Kosten des Benutzers notwendig werden.
4 Elektrische Sicherheit EN60950 (TUV), UL1950 (
cULus
)
Sicherheit
5Laser EN60825
6 Warnung: Laserprodukt der Klasse 1.
7 Warnung: Nicht direkt in den Strahl blicken.
8 Gefahr Durch Blitzschlag
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters ausführen
9 Entlüftungsöffnungen nicht versperren
10 Der Buchse darf nur aus dem Adapter Strom zugeführt werden.
Europe - EU
Gebrauchen Sie einen von TÜV zugelassenen Wechselstromadapter für Gleichstrom 12 V, 500 mA.
11 Betriebstemperatur: Dieses Produkt wurde für den Betrieb in einer
Umgebungstemperatur von nicht mehr als 40° C entworfen.
12 Alle Länder: Installation muß örtlichen und nationalen elektrischen
Vorschriften entsprechen.
24
Page 35
AT-LMC10SC and AT-LMC10ST Installation Guide
Standarder: Dette produkt tilfredsstiller de følgende standarder.
1 Radiofrekvens forstyrrelsesemissionEN55022 Klasse B
2 Immunitet EN55024
3Advarsel: Dette produkt skal bruges med afskærmede kabler for at
overholde bestemmelserne vedrørende udstråling og støjimmunitet. Hvis det bruges med uafskærmede kabler, kan det blive påkrævet af brugeren at korrigere interferensproblemer for egen regning.
4 Elektrisk sikkerhed. EN60950 (TUV), UL1950 (
cULus
)
Sikkerhed
5Laser EN60825
6Advarsel: Laserprodukt av klasse 1.
7Advarsel: Stirr ikke på strålen.
8 Fare Under Uvejr
Fare: Undlad at arbejde på udstyr eller kabler i perioder med lynaktivitet.
9 Ventilationsåbningerne må ikke blokeres
10 Strømforsyningen til apparatet må udelukkende tages fra
tilpasningstransformatoren.
Europe - EU
Brug kun TÜV godkendt vekselstrømstransformator på 12 V jævnstrøm, 500 mA.
11 Betjeningstemperatur: Dette apparat er konstrueret til en omgivende
temperatur på maksimum 40 grader C.
12 Alle Lande: Installation af produktet skal ske i overensstemmelse med
lokal og national lovgivning for elektriske installationer.
25
Page 36
Translated Electrical Safety and Emission Information
Eisen: Dit product voldoet aan de volgende eisen.
1RFI Emissie EN55022 Klasse B
2 Immuniteit EN55024
3 Waarschuwing: Om te voldoen aan de emissie- en immuniteitsnormen
dient dit apparaat te zijn voorzien van afgeschermde kabels. Als het met niet-afgeschermde kabels wordt gebruikt, kan het zijn dat de gebruiker maatregelen moet treffen om interferentieproblemen voor eigen rekening op te lossen.
4 Electrische Veiligheid EN60950 (TUV), UL1950 (
cULus
)
Veiligheid
5Laser EN60825
6 Waarshuwing: Klasse-1 laser produkt.
7 Waarchuwing: Neit in de straal staren.
8 Gevaar Voor Blikseminslag
Gevaar: Niet aan toestellen of kabels werken bij bliksem.
9 Ventilatiegaten niet blokkeren
10 Stroom mag alleen via de adapter naar het apparaat toegevoerd worden.
Europe - EU
Gebruik een door TÜV gekeurde wisselstroomadapter van 12 Volt gelijkstroom, 500 milliampères.
11 Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag
niet meer bedragen dan 40 graden Celsius.
12 Alle Landen: het toestel installeren overeenkomstig de lokale en nationale
elektrische voorschriften.
26
Page 37
AT-LMC10SC and AT-LMC10ST Installation Guide
Normes: ce produit est conforme aux normes de suivantes.
1 Emission d'interférences
radioélectriques EN55022 Classe
B
2 Immunité EN55024
3Avertissement: Il faut utiliser des câbles blindés pour ce produit afin de
respecter les normes d’émission et d’immunité. Si l’utilisateur choisit d’utiliser des câbles non blindés, il sera peut-être contraint de prendre les mesures nécessaires pour corriger les problèmes d’interférences, ainsi que d’assumer le coût correspondant.
4 Sécurité Électrique EN60950 (TUV), UL1950 (
cULus
)
Sécurité
5Laser EN60825
6 Attention Producit laser di classe 1.
7 Attention Ne pas fixer le faisceau des yeux.
8 Danger De Foudre
Danger: Ne pas manier le matériel ou les câbles lors d'activité orageuse.
9 Ne pas bloquer les fentes d'aération
10 L'alimentation du concentrateur doit être uniquement fournie par
l'adaptateur.
Europe - EU
Utiliser un adaptateur secteur conforme TÜV de 12 V, 500 mA en courant continu.
11 Température De Fonctionnement: Ce matériel est capable de tolérer une
température ambiante maximum de 40 degrés Celsius.
12 Pour Tous Pays: Installer le matériel conformément aux normes
électriques nationales et locales.
27
Page 38
Translated Electrical Safety and Emission Information
Standardit: Tämä tuote on seuraavien standardien mukainen.
1 Radioaaltojen häirintä EN55022 Luokka B
2 Kestävyys EN55024
3 Varoitus: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja
häiriönsietostandardien mukaisesti. Jostuotetta käytetään ilman suojattuja kaapeleita, käyttäjä voi joutua korjaamaan häirinnän aiheuttaman ongelman omallakustannuksellaan.
4 Sähköturvallisuus EN60950 (TUV), UL1950 (
cULus
)
Turvallisuus
5Laser EN60825
6 Varoitus: Luokan 1 Lasertuote.
7Variotus: Älä katso säteeseen.
8 Salamaniskuvaara
Engenvaara: Älä työskentele laitteiden tai kaapeleiden kanssa salamoinnin aikana.
9 Älä tuki ilmareikiä
10 Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan
sovittimesta.
Europe - EU
Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen nimellisarvot ovat DC 12 V, 500 mA (milliampeeria).
11 Käyttölämpötila: Tämä tuote on suunniteltu ympäröivän ilman
maksimilämpötilalle 40° C.
12 Kaikki Maat: Asenna tuote paikallisten ja kansallisten
sähköturvallisuusmääräysten mukaisesti.
28
Page 39
AT-LMC10SC and AT-LMC10ST Installation Guide
Standard: Questo prodotto è conforme ai seguenti standard.
1 Emissione RFI (interferenza
di radiofrequenza) EN55022 Classe
B
2 Immunità EN55024
3Avvertenza: questo prodotto, se utilizzato con cavi schermati, è conforme
alle norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente può dover adottare a proprie spese misure correttive contro le interferenze.
4 Sicurezza Elettrica EN60950 (TUV), UL1950 (
cULus
)
Norme Di Sicurezza
5Laser EN60825
6 Avvertenza: Prodotto laser di Classe 1.
7Avertenza: Non fissare il raggio con gli occhi.
8Pericolo Di Fulmini
Pericolo: Non lavorare sul dispositivo o sui cavi durante precipitazioni temporalesche.
9 Non ostruire le prese d'aria
10 Questo dispositivo deve essere alimentato solo mediante l’adattatore.
Europe - EU
Utilizzare l’adattatore per c.a. da 12 V c.c. e 500 mA conforme alla normativa TÜV.
11 Temperatura Di Funzionamento: Questo prodotto è concepito per una
temperatura ambientale massima di 40 gradi centigradi.
12 Tutti I Paesi: installare il prodotto in conformità delle vigenti normative
elettriche nazionali.
29
Page 40
Translated Electrical Safety and Emission Information
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
1 RFI stråling EN55022 Klasse B
2 Immunitet EN55024
3Advarsel: Dette produktet må brukes med vernede kabler for å tilfredsstille
emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler, må brukeren muligens rette forstyrrelsesproblemene for egen regning.
4 Elektrisk sikkerhet EN60950 (TUV), UL1950 (
cULus
)
Sikkerhet
5Laser EN60825
6Advarsel: Laserprodukt av klasse 1.
7Advarsal: Stirr ikke på strålen.
8 Fare For Lynnedslag
Fare: Arbeid ikke på utstyr eller kabler i tordenvær.
9 Blokker ikke luftventilene
10 All strømtilførsel må komme fra adapteren.
Europe - EU
Benytt TÜV-godkjent AC-adapter på 12VDC, 500mA (millismpere)
11 Driftstemperatur: Dette produktet er konstruert for bruk i maksimum
romtemperatur på 40 grader celsius.
12 Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale
elektriske koder.
30
Page 41
AT-LMC10SC and AT-LMC10ST Installation Guide
Padrões: Este produto atende aos seguintes padrões.
1 Emissão De Interferência De
Radiofrequência EN55022 Classe
B
2Imunidade EN55024
3Advertência: Este produto requer a utilização de cabos blindados para
cumprimento dos standards de limites de emissão e imunidade. Se o produto for utilizado com cabos não blindados, o utilizador poderá necessitar de tomar medidas para correcção de problemas de interferência, por sua própria conta.
4 Segurança Eléctrica EN60950 (TUV), UL1950 (
cULus
)
Segurança
5Laser EN60825
6Aviso Produto laser de classe 1.
7Aviso Não olhe fixamente para o raio.
8 Perigo De Choque Causado Por Raio
Perigo: Não trabalhe no equipamento ou nos cabos durante períodos suscetíveis a quedas de raio.
9 Não bloqueie as aberturas de ventilação
10 Use somente o adaptador fornecido para alimentação elétrica do hub.
Europe - EU
Use um adaptador de corrente alternada com saída DC de 12V e 500mA em conformidade com as especificações da TÜV.
11 Temperatura De Funcionamento: Este produto foi projetado para uma
temperatura ambiente máxima de 40 graus centígrados.
12 Todos Os Países: Instale o produto de acordo com as normas nacionais e
locais para instalações elétricas.
31
Page 42
Translated Electrical Safety and Emission Information
Estándares: Este producto cumple con los siguientes estándares.
1Emisión RFI EN55022 Clase
B
2 Inmunidad EN55024
3Advertencia: Este producto exige cables protectores para ajustarse a las
normas de emisión e inmunidad. Si se utiliza con cables sin protección, el usuario tendrá que correr con los gastos por las medidas a tomar en caso de problemas de interferencias.
4 Seguridad Eléctrica EN60950 (TUV), UL1950 (
cULus
)
Seguridad
5Laser EN60825
6 ¡Advertencia! Producto láser Clase 1.
7 ¡Advertencia! No mirat fijamente el haz.
8Peligro De Rayos
Eligro: No realice ningun tipo de trabajo o conexion en los equipos o en los cables durantetormentas electricas.
9 No bloquee las aberturas para ventilacion
10 La energía para el dispositivo central o "hub" debe provenir únicamente del
adaptador.
Europe - EU
Utilizar un adaptador de corriente alterna autorizado TÜV de 12 voltios de corriente continua y 500 miliamperios.
11 Temperatura Requerida Para La Operación: Este producto está
diseñado para una temperatura ambiental máxima de 40 grados C.
12 Para Todos Los Países: Monte el producto de acuerdo con los Códigos
Eléctricos locales y nacionales.
32
Page 43
AT-LMC10SC and AT-LMC10ST Installation Guide
Standarder: Denna produkt uppfyller följande standarder.
1Radiostörning EN55022 Klass B
2 Immunitet EN55024
3 Varning! Denna produkt kräver skärmade kablar för att uppfylla
standardkraven för emission och immunitet. Om den används med oskärmade kablar kan användaren vara tvungen att vidta åtgärder på egen bekostnad för att åtgärda störningsproblemet.
4Elsäkerhet EN60950 (TUV), UL1950 (
cULus
)
Säkerhet
5Laser EN60825
6 Varning! Laserprodukt av klass 1.
7 Varning! Laserstrålning när enheten är öppen.
8 Fara För Blixtnedslag
Fara: arbeta ej på utrustningen eller kablarna vid åskväder.
9 Blockera inte luftventilerna
10 Endast anslutningsenheten får vara kraftkälla till centralen.
Europe - EU
Använd en växelströmsanslutningsenhet licensierad av TÜV. Likström 12V, 500mA.
11 Driftstemperatur: Denna produkt är konstruerad för rumstemperatur ej
överstigande 40 grader Celsius.
12 Alla Länder: Installera produkten i enlighet med lokala och statliga
bestämmelser för elektrisk utrustning.
33
Page 44