AGILENT Model 6641A: 3217A-00111 and Above *
AGILENT Model 6642A: 3204A-00111 and Above *
AGILENT Model 6643A: 3205A-00111 and Above *
AGILENT Model 6644A: 3213A-00111 and Above *
AGILENT Model 6645A: 3215A-00111 and Above *
AGILENT Model 6651A: 3130A-00171 and Above *
AGILENT Model 6652A: 3201A-00381 and Above *
AGILENT Model 6653A: 3145A-00551 and Above *
AGILENT Model 6654A: 3148A-00391 and Above *
AGILENT Model 6655A: 3152A-00176 and Above *
AGILENT Model 6671A: 3129A-00218 and Above *
AGILENT Model 6672A: 3138A-00101 and Above *
AGILENT Model 6673A: 3138A-00101 and Above *
AGILENT Model 6674A: 3133A-00161 and Above *
AGILENT Model 6675A: 3138A-00101 and Above *
AGILENT Model 6680A: 3302A-00101 and Above *
AGILENT Model 6681A: 3250A-00101 and Above *
AGILENT Model 6682A: 3339A-00101 and Above *
AGILENT Model 6683A: 3339A-00161 and Above *
AGILENT Model 6684A: 3339A-00101 and Above *
* For instruments with higher Serial Numbers, a change page may be included.
S1
Agilent Part No. 5961-2579 Printed in USA: March 1995
Microfiche Part No. 5961-2580Reprinted: April 2000
CERTIFICATION
Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory.
Agilent Technologies further certifies that its calibration measurements are traceable to the United States National
Bureau of Standards, to the extent allowed by the Bureau’s calibration facility, and to the calibration facilities of other
International Standards Organization members.
WARRANTY
This Agilent Technologies hardware product is warranted against defects in material and workmanship for a period of three
years from date of delivery. Agilent Technologies software and firmware products, which are designated by Agilent
Technologies for use with a hardware product and when properly installed on that hardware product, are warranted not to
fail to execute their programming instructions due to defects in material and workmanship for a period of 90 days from date
of delivery. During the warranty period Agilent Technologies will, at its option, either repair or replace products which
prove to be defective. Agilent Technologies does not warrant that the operation of the software, firmware, or hardware shall
be uninterrupted or error free.
For warranty service, with the exception of warranty options, this product must be returned to a service facility designated
by Agilent Technologies. Customer shall prepay shipping charges by (and shall pay all duty and taxes) for products returned
to Agilent Technologies for warranty service. Except for products returned to Customer from another country, Agilent
Technologies shall pay for return of products to Customer.
Warranty services outside the country of initial purchase are included in Agilent Technologies’ product price, only if
Customer pays Agilent Technologies international prices (defined as destination local currency price, or U.S. or Geneva
Export price).
If Agilent Technologies is unable, within a reasonable time to repair or replace any product to condition as warranted, the
Customer shall be entitled to a refund of the purchase price upon return of the product to Agilent Technologies.
LIMITATION OF WARRANTY
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Customer,
Customer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental
specifications for the product, or improper site preparation and maintenance. NO OTHER WARRANTY IS EXPRESSED
OR IMPLIED. Agilent Technologies SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
EXCLUSIVE REMEDIES
THE REMEDIES PROVIDED HEREIN ARE THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDIES. AGILENT
TECHNOLOGIES SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY.
ASSISTANCE
The above statements apply only to the standard product warranty. Warranty options, extended support contracts, product
maintenance agreements and customer assistance agreements are also available. Contact your nearest Agilent
Technologies Sales and Service offices for further information on Agilent Technologies’ full line of Support Programs.
2
SAFETY SUMMARY
The following general safety precautions must be observed during all phases of operation, service, and repair of this
instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety
standards of design, manufacture, and intended use of the instrument. Agilent Technologies assumes no liability for the
customer’s failure to comply with these requirements.
BEFORE APPLYING POWER.
Verify that the product is set to match the available line voltage and the correct fuse is installed.
GROUND THE INSTRUMENT.
This product is a Safety Class 1 instrument (provided with a protective earth terminal). To minimize shock hazard, the instrument chassis
and cabinet must be connected to an electrical ground. The instrument must be connected to the ac power supply mains through a threeconductor power cable, with the third wire firmly connected to an electrical ground (safety ground) at the power outlet. For instruments
designed to be hard-wired to the ac power lines (supply mains), connect the protective earth terminal to a protective conductor before any
other connection is made. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will
cause a potential shock hazard that could result in personal injury. If the instrument is to be energized via an external autotransformer for
voltage reduction, be certain that the autotransformer common terminal is connected to the neutral (earthed pole) of the ac power lines
(supply mains).
FUSES.
Only fuses with the required rated current, voltage, and specified type (normal blow, time delay, etc.) should be used. Do not use repaired
fuses or short circuited fuseholders. To do so could cause a shock or fire hazard.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE.
Do not operate the instrument in the presence of flammable gases or fumes.
KEEP AWAY FROM LIVE CIRCUITS.
Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by qualified
service personnel. Do not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even
with the power cable removed. To avoid injuries, always disconnect power, discharge circuits and remove external voltage sources before
touching components.
DO NOT SERVICE OR ADJUST ALONE.
Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
DO NOT EXCEED INPUT RATINGS.
This instrument may be equipped with a line filter to reduce electromagnetic interference and must be connected to a properly grounded
receptacle to minimize electric shock hazard. Operation at line voltages or frequencies in excess of those stated on the data plate may
cause leakage currents in excess of 5.0 mA peak.
SAFETY SYMBOLS.
Instruction manual symbol: the product will be marked with this symbol when it is necessary for the user to refer to the
instruction manual (refer to Table of Contents) .
The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly
performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING sign until the
indicated conditions are fully understood and met.
The CAUTION sign denotes a hazard. It calls attention to an operating procedure, or the like, which, if not correctly
performed or adhered to, could result in damage to or destruction of part or all of the product. Do not proceed
beyond a CAUTION sign until the indicated conditions are fully understood and met.
DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT.
Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the
instrument. Return the instrument to an Agilent Technologies Sales and Service Offices for service and repair to ensure that safety
features are maintained.
Instruments which appear damaged or defective should be made inoperative and secured against unintended operation until they can be
repaired by qualified service personnel.
3
SAFETY SUMMARY (continued)
GENERAL
Any LEDs used in this product are Class 1 LEDs as per IEC 825-l.
ENVIRONMENTAL CONDITIONS
With the exceptions noted, all instruments are intended for indoor use in an installation category II, pollution degree 2
environment. They are designed to operate at a maximum relative humidity of 95% and at altitudes of up to 2000 meters.
Refer to the specifications tables for the ac mains voltage requirements and ambient operating temperature range.
Exceptions: Agilent Technologies Models 6680A, 6681A, 6682A, 6683A, 6684A, 6814A, and 6834A are intended for use
in an installation category III environment.
SAFETY SYMBOL DEFINITIONS
SymbolDescriptionSymbolDescription
Direct currentTerminal for Line conductor on permanently
installed equipment
Alternating currentCaution, risk of electric shock
Both direct and alternating currentCaution, hot surface
Three-phase alternating currentCaution (refer to accompanying documents)
Earth (ground) terminalIn position of a bi-stable push control
Protective earth (ground) terminalOut position of a bi-stable push control
Frame or chassis terminalOn (supply)
Terminal for Neutral conductor on permanently
installed equipment
Terminal is at earth potential(Used for
measurement and control circuits designed to
be operated with one terminal at earth
potential.)
Herstellerbescheinigung
Diese Information steht im Zusammenhang mit den Anforderungen der Maschinenläminformationsverordnung vom 18
Januar 1991.
* Schalldruckpegel Lp <70 dB(A) * Am Arbeitsplatz * Normaler Betrieb * Nach EN 27779 (Typprufung).
Manufacturer’s Declaration
This statement is provided to comply with the requirements of the German Sound Emission Directive, from 18 January
1991.
Off (supply)
Standby (supply)
Units with this symbol are not completely
disconnected from ac mains when this switch is
off. To completely disconnect the unit from ac
mains, either disconnect the power cord or
have a qualified electrician install an external
switch.
* Sound Pressure Lp <70 dB(A) *At Operator Position * Normal Operation * According to EN 27779 (Type Test).
4
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacturer’s Name:Agilent Technologies Inc.
Manufacturer’s Address:140 Green Pond Road
Rockaway, New Jersey 07866
U.S.A.
declares that the Product
Product Name:a) Single Output System Power Supply
b) General Purpose Power Supply
Model Number:a) Agilent 6641A, 6642A, 6643A, 6644A, 6645A
b) Agilent 6541A, 6542A, 6543A, 6544A, 6545A
conforms to the following Product Specifications:
Safety:IEC 348:1978 / HD 401S1: 1981
EMC:CISPR 11:1990 / EN 55011:1991 - Group 1 Class B
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC and carries the CE-marking accordingly.
Note 1: The product family was introduced prior to 12/93.
New Jersey January 1997
Location Date Bruce Krueger / Quality Manager
European Contact: Your local Agilent Technologies Sales and Service Office or Agilent Technologies GmbH,
Department TRE, Herrenberger Strasse 130, D-71034 Boeblingen (FAX:+49-7031-14-3143)
1
IEC 801-2:1991 / EN 50082-1:1992 - 4 kV CD, 8 kV AD
IEC 801-3:1984 / EN 50082-1:1992 - 3 V / m
IEC 801-4:1988 / EN 50082-1:1992 - 0.5 kV Signal Lines
1 kV Power Lines
5
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacturer’s Name:Agilent Technologies Inc.
Manufacturer’s Address:140 Green Pond Road
Rockaway, New Jersey 07866
U.S.A.
declares that the Product
Product Name:a) Single Output System Power Supply
b) General Purpose Power Supply
Model Number:a) Agilent 6651A, 6652A, 6653A, 6654A, 6655A
b) Agilent 6551A, 6552A, 6553A, 6554A, 6555A
conforms to the following Product Specifications:
Safety:IEC 348:1978 / HD 401S1: 1981
EMC:CISPR 11:1990 / EN 55011:1991 - Group 1 Class B
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC and carries the CE-marking accordingly.
Note 1: The product family was introduced prior to 12/93.
New Jersey January 1997
Location Date Bruce Krueger / Quality Manager
European Contact: Your local Agilent Technologies Sales and Service Offices or Agilent Technologies GmbH,
Department TRE, Herrenberger Strasse 130, D-71034 Boeblingen (FAX:+49-7031-14-3143)
1
IEC 801-2:1991 / EN 50082-1:1992 - 4 kV CD, 8 kV AD
IEC 801-3:1984 / EN 50082-1:1992 - 3 V / m
IEC 801-4:1988 / EN 50082-1:1992 - 0.5 kV Signal Lines
1 kV Power Lines
6
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacturer’s Name:Agilent Technologies Inc.
Manufacturer’s Address:140 Green Pond Road
Rockaway, New Jersey 07866
U.S.A.
declares that the Product
Product Name:a) Single Output System Power Supply
b) General Purpose Power Supply
Model Number:a) Agilent 6671A, 6672A, 6673A, 6674A, 6675A
b) Agilent 6571A, 6572A, 6573A, 6754A, 6575A
conforms to the following Product Specifications:
Safety:IEC 348:1978 / HD 401S1: 1981
EMC:CISPR 11:1990 / EN 55011:1991 - Group 1 Class B
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC and carries the CE-marking accordingly.
Note 1: The product family was introduced prior to 12/93.
New Jersey January 1997
Location Date Bruce Krueger / Quality Manager
European Contact: Your local Agilent Technologies Sales and Service Offices or Agilent Technologies GmbH,
Department TRE, Herrenberger Strasse 130, D-71034 Boeblingen (FAX:+49-7031-14-3143)
1
IEC 801-2:1991 / EN 50082-1:1992 - 4 kV CD, 8 kV AD
IEC 801-3:1984 / EN 50082-1:1992 - 3 V / m
IEC 801-4:1988 / EN 50082-1:1992 - 0.5 kV Signal Lines
1 kV Power Lines
7
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacturer’s Name:Agilent Technologies Inc.
Manufacturer’s Address:140 Green Pond Road
Rockaway, New Jersey 07866
U.S.A.
declares that the Product
Product Name:Single Output System Power Supply
Model Number:Agilent 6680A, 6681A, 6682A, 6683A, 6684A
conforms to the following Product Specifications:
Safety:IEC 348:1978 / HD 401S1: 1981
1
EMC:CISPR 11:1990 / EN 55011:1991 - Group 1 Class A
IEC 801-2:1991 / EN 50082-1:1992 - 4 kV CD, 8 kV AD
IEC 801-3:1984 / EN 50082-1:1992 - 3 V / m
IEC 801-4:1988 / EN 50082-1:1992 - 0.5 kV Signal Lines
1 kV Power Lines
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC and carries the CE-marking accordingly.
Note 1: The product family was introduced prior to 12/93.
New Jersey January 1997
Location Date Bruce Krueger / Quality Manager
European Contact: Your local Agilent Technologies Sales and Service Office or Agilent Technologies GmbH,
Department TRE, Herrenberger Strasse 130, D-71034 Boeblingen (FAX:+49-7031-14-3143)
PRINTING HISTORY
The edition and current revision of this manual are indicated below. Reprints of this manual containing minor corrections
and updates may have the same printing date. Revised editions are identified by a new printing date. A revised edition
incorporates all new or corrected material since the previous printing date. Changes to the manual occurring between
revisions are covered by change sheets shipped with the manual. In some cases, the manual change applies only to specific
instruments. Instructions provided on the change sheet will indicate if a particular change applies only to certain
instruments.
This document contains proprietary information protected by copyright. All rights are reserved. No part of this document
may be photocopied, reproduced, or translated into another language without the prior consent of Agilent Technologies.
Information contained in this document is subject to change without notice.
Temperature Performance .......................................................................................................................44
Input Power Source ...................................................................................................................................45
Series 664xA and 665xA Supplies..........................................................................................................45
Series 667xA Supplies.............................................................................................................................45
Series 668xA Supplies.............................................................................................................................47
Using the Keypad..........................................................................................................................................50
In Case of Trouble.......................................................................................................................................53
Line Fuse...................................................................................................................................................53
Analog Connector........................................................................................................................................58
Digital Connector........................................................................................................................................58
Connecting Series 664xA and 665xA Power Supplies to the Load.............................................................59
Setting the GPIB Address..............................................................................................................................91
General Procedure......................................................................................................................................93
Test Setup..................................................................................................................................................94
Front Panel Calibration .................................................................................................................................94
Entering the Calibration Values ............................................................................................................... 94
Saving the Calibration Constants...............................................................................................................94
Disabling the Calibration Mode ................................................................................................................94
Changing the Calibration Password............................................................................................................94
Recovering From Calibration Problems.....................................................................................................97
Calibration over the GPIB.............................................................................................................................98
Test Equipment Required.........................................................................................................................103
List of Equipment....................................................................................................................................103
Current Monitoring Resistor....................................................................................................................103
Performing the Tests ................................................................................................................................105
General Measurement Techniques ..........................................................................................................105
Programming the Power Supply..................................................................................................................105
Order of Tests..........................................................................................................................................105
Voltage Programming and Readback Accuracy..........................................................................................105
Current Programming and Readback Accuracy.......................................................................................106
Verification Test Parameters.................................................................................................................... 107
CLine Voltage Conversion
Series 664xA and 665xA Supplies..............................................................................................................115
Series 667xA Supplies..............................................................................................................................116
Series 668xA Supplies..............................................................................................................................117
DDigital Port Functions
Digital Connector........................................................................................................................................119
Changing the Port Configuration.................................................................................................................122
Digital I/O Operation...................................................................................................................................122
Relay Link Operation..................................................................................................................................123
ECurrent Loop Compensation
Function of Loop Compensation.................................................................................................................125
Setting the Loop Compensation Switch.......................................................................................................128
11
FUsing Agilent 668xA Series Power Supplies in Autoparallel
Auto parallel Procedure...............................................................................................................................129
B-l. Equipment Required for Verification Tests ...........................................................................103
B-2.Voltage Programming and Readback Accuracy Tests...........................................................105
B-3. Current Programming and Readback Accuracy Test.............................................................106
B-4. Test Parameters for Series 664xA..........................................................................................107
B-5. Test Parameters for Series 665xA..........................................................................................109
B-6. Test Parameters for Series 667xA..........................................................................................111
B-7. Test Parameters for Series 668xA..........................................................................................113
E-l. Settings for CC Loop Compensation Switch..........................................................................125
14
1
General Information
Introduction
Two guides are shipped with your power supply - an Operating Guide (this document) and a Programming Guide. You will
find information on the following tasks in these guides:
Quick Document Orientation
TopicLocation
Calibrating the power supplyAppendix A - this guide
Compatibility programming languageAppendix B - Programming Guide
Configuring the digital portAppendix D - this guide
Line voltage:
Connecting ac power sourceChapter 2 - this guide
Converting the ac source voltageAppendix B - this guide
Source current, frequency, and power ratingsChapter 1- this guide
Operator replaceable partsChapter 1- this guide
Operator troubleshootingChapter 3 - this guide
Output impedance characteristicsChapter 1- this guide
Power supply accessoriesChapter 1- this guide
Power supply operating characteristicsChapter 1- this guide
Power supply optionsChapter 1- this guide
Power supply performance specificationsChapter 1- this guide
Programming
discrete fault inhibit (DFI) operationChapter 4 - Programming Guide
from the analog portChapter 4 - this guide
from the front panelChapter 5 - this guide
over the GPIBChapter 2 - Programming Guide
remote inhibit (RI) operationChapter 4 - Programming Guide
status registersChapter 4 - Programming Guide
Quick operating checkout (without load)Chapter 3 - this guide
Rack mountingChapter 2 - this guide
SCPI programming languageChapter 3 - Programming Guide
Wiring
analog programming portChapter 4 - this guide
discrete fault indicator (DFI) operationAppendix D - this guide
digital portAppendix D - this guide
GPIB controllerChapter 4 - this guide
load or loadsChapter 4 - this guide
local sensingChapter 4 - this guide
remote inhibit (RI) operationChapter 4 - this guide
remote sensingChapter 4 - this guide
1
1
See the Table of Contents for complete list of topics.
General Information 15
Safety Considerations
This power supply is a Safety Class 1 instrument, which means it has a protective earth terminal. That terminal must be
connected to earth ground through a power source equipped with a 3-wire ground receptacle. Refer to the Safety Summary
page at the beginning of this guide for general safety information. Before installation or operation, check the power supply
and review this guide for safety warnings and instructions. Safety warnings for specific procedures are located at
appropriate places in the guide.
Instrument Identification
The power supply is identified by a unique two-part serial number, such as, 3343A-00177. The first part, or prefix, is a
number-letter combination that provides the following information:
3343 = The year and week of manufacture or last significant design change. Add 1960 to the first two digits to determine
the year. For example, 32=1992, 33=1993, etc. The last two digits specify the week of the year (43 = the 43rd
week).
A =The letter indicates the country of manufacture, where A = USA.
Options
List of Options
OptionDescriptionUsed with Agilent Series
664xA665xA667xA668xA
100
200
220
240
400
601
602
831
832
834
841
842
843
844
861
862
908
Input power 100 Vac, nominalxx
Input power 200 Vac, nominalx
Input power 220 Vac, nominalxx
Input power 240 Vac, nominalxx
Input power 360-440 Vac, 3 -phasex
Output connector kit required for bench applicationsx
Bus bar spacers for paralleling power suppliesx
Power cord, 12 AWG, UL listed, CSA certified, without plugx
Power cord, 4 mm
2
, harmonized, without plugx
Power cord, 10 AWG, UL listed, CSA certified, without plugx
Power cord, 12 AWG, UL listed, CSA certified, with NEMA
6-20P 20A/250V plug
Power cord, 4 mm
2
, harmonized, with IEC 309 32A/220V
x
x
plug
Power cord, 12 AWG, UL listed, CSA certified, with JIS
x
C8303 25A/250V plug
Power cord, 10 AWG, UL listed, CSA certified, with NEMA
x
L6-30P-30A/250V locking plug
Power cord, 10 AWG, UL listed, 300 V, CSA certified,
without plug
2
Power cord, 2.5 mm
, 4-wire, harmonized, without plug
Rack mount kit (Agilent 5062-3974)x
Rack mount kit (Agilent 5062-3977) Support rails (E3663A)
xx
are required.
Rack mount kit (Agilent 5062-3977 & 5062-3974) Support
rails (E3663A) are required.
x
x
x
General Information16
List of Options (continued)
OptionDescriptionUsed with Agilent Series
664xA665xA667xA668xA
909
909Rack mount kit with handles (Agilent 5062-3983) Support
910
ABD
ABE
ABF
ABJ
ABZ
AB0
Rack mount kit with handles (Agilent 5062-3975)x
xx
rails (E3663A) are required.
Rack mount kit with handles (Agilent 5062-3983 &5062-3974) Support rails (E3663A) are required.
Service manual with extra Operating and Programming
Fuse replacement kit for Series 668xA
16 AM for 360-440 Vac, 3-phase line5060-3512
30 AM for 180-235 Vac, 3-phase line5060-3513
GPIB cable (all models)
0.5 meters (1.6 ft)10833D
1.0 meter (3.3 ft)10833A
2.0 meters (6.6 ft)10833B
4.0 meters ( 13 .2 ft)10833C
Serial link cable (all models)
2.0 meters (6.6 ft)5080-2148
Slide mount kit
heavy duty, for Series 667xA/668xA1494-0058
standard, for Series 664xA/665xA1494-0059
x
Description
These units form a family of unipolar, GPIB programmable power supplies organized as follows:
FamilyPowerModels
Series 664xA200 WAGILENT 6641A, 6642A, 6643A, 6644A, 6645A
Series 665xA500 WAGILENT 6651A, 6652A, 6653A, 6654A, 6655A
Series 667xA2000 WAGILENT 6671A, 6672A, 6673A, 6674A, 6675A
Series 668xA5000 WAGILENT 6680A, 6681A, 6682A, 6683A, 6684A
Each power supply is programmable locally from the front panel or remotely via a rear-panel analog control port.
General Information 17
Operational features include:
■ Constant voltage (CV) or constant current (CC) output over the rated output range.
■ Built-in overvoltage (OV), overcurrent (OC), and overtemperature (OT) protection.
■ Automatic turn-on selftest.
■ Pushbutton nonvolatile storage and recall of up to 5 operating states (4 in Series 668xA supplies).
■ Local or remote sensing of output voltage.
■ Auto-parallel operation for increased total current.
■ Series operation for increased total voltage.
■ Analog input for remote programming of voltage and current.
■ Voltage output for external monitoring of output current.
■ User calibration from the front panel.
Front Panel Programming
The front panel has both rotary (RPG) and keypad controls for setting the output voltage and current. The panel display
provides digital readouts of the output voltage and current. Other front panel controls permit:
■ Enabling or disabling the output.
■ Setting the overvoltage protection (OVP) trip voltage.
■ Enabling or disabling the overcurrent protection (OCP) feature.
■ Saving and recalling operating states.
■ Setting the GPIB address.
■ Reading GPIB error message codes.
■ Calibrating the power supply, including changing the calibration protection password.
Remote Programming
The power supply may be remotely programmed via the GPIB bus and/or from an analog input port. GPIB programming is
with SCPI (Standard Commands for Programmable Instruments) commands that make the power supply programs
compatible with those of other GPIB instruments. (A software-controlled Compatibility Mode also permits programming in
the command set of the Agilent 6030xA Autoranging Series.) In addition to control functions, SCPI programming permits
writing to the front panel LCD and complete calibration functions. Power supply status registers permit remote monitoring
of the following conditions:
■ Overvoltage, overcurrent, overtemperature, and unregulated states.
■ Operating mode (constant voltage or constant current).
■ State of the RI (remote inhibit) input signal.
■ Power-on status (PON).
■ Status of the output queue (QYE).
■ Pending triggers (WTG).
■ GPIB interface programming errors (CME, DDE, and EXE).
■ Calibration state (enabled or disabled).
The status registers can be programmed to generate an output fault signal (FLT) upon the occurrence of one or more
selected status events.
Analog Programming
The power supply has an analog port for remote programming. The output voltage and/or current of the power supply may
be controlled by individual d-c programming voltages applied to this port. The port also provides a monitor output that
supplies a d-c voltage proportional to the output current.
General Information18
Output Characteristic
General
The power supply can operate in either CV (constant voltage) or CC (constant current) over its voltage and current ratings
(see Table 1-l). The operating locus is shown by the Output Characteristic Curve in Table 1-2. The operating point is
determined by the voltage setting (V
), the current setting (Is), and the load impedance. Two operating points are shown.
s
Point 1 is defined by the load line cutting the operating locus in the constant-voltage region. This region defines the CV
mode. Point 2 is defined by the load line cutting the operating locus in the constant-current region. This region defines the
CC mode.
Downprogramming
The power supply can sink current for more rapid down programming in the CV mode. For Series 664xA and 665xA
supplies, this capability is defined by the second quadrant area (-I
) of the Output Characteristic Curve. These supplies can
s
sink about 20% of their maximum rated positive output current. For Series 667xA and 668xA power supplies, this is an
uncharacterized current-sinking area that provides a limited downprogramming capability.
Specifications and Supplemental Characteristics
Tables 1-1 through 1-4 list the specifications and supplemental characteristics for the Series 664xA, 665xA, 667xA, and
668xA power supplies. The organization is as follows:
Readback Accuracy (from front panel or over GPIB with respect to actual output @ 25 ±:5 °C)
Voltage: 0.07% + 6 mV 15 mV 25 mV 40 mV 80 mV+Current 0.15% + 18 mA 9.1 mA 5 mA 3 mA 1.3 mA
-Current 0.35% +
40 mA 20 mA 12 mA 6.8 mA 2.9 mA
Load Regulation (change in output voltage or current for any load change within ratings)
Voltage
Current:
1 mV 2 mV 3 mV 4 mV 5 mV
1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA
Line Regulation (change in output voltage or current for any line change within ratings
Voltage:
Current:
0.5 mV 0.5 mV 1 mV 1 mV 2 mV
1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA
Transient Response Time (for the output voltage to recover to its previous level (within 0.1% of the rated voltage or
20 mV, whichever is greater) following any step change in load current up to 50% of the rated current.
< 100 µs
AC Input Ratings (selectable via internal switching - see Appendix B)Nominal line voltage 100,120,220,240 Vac: 230 Vac:
F requency range:
-13%, +6 %
-10%, +10%
47-63 Hz
Output Terminal Isolation
±240 Vdc (maximum, from chassis ground)
Notes: 1For Supplemental Characteristics, see Table 1-1b.
General Information20
Table 1-1b. Supplemental Characteristics for Series 664xA
1
Parameter Agilent Model Number
6641A 6642A 6643A 6644A 6645A
Output Programming Range (maximum programmable values)
Voltage:
Current:
Overvoltage Protection (OVP):
8.190 V 20.475 V 35.831 V 61.425 V 122.85 V
20.475 A 10.237 A 6.142 A 3.583 A 1.535 A
8.8 V 22.0 V 38.5 V 66.0 V 132.0 V
Average Resolution
Voltage:
Current:
Overvoltage Protection (OVP):
2 mV 5 mV 10 mV 15 mV 30 mV
6 mA 3 mA 2 mA 1.2 mA 0.5 mA
13 mV 30 mV 54 mV 93 mV 190 mV
Accuracy
Overvoltage Protection (OVP):
Analog Programming (VP):*
0.36% +
Analog Programming (IP):*
160 mV 400 mV 700 mV 1.2 V 2.4 V
6 mV 15 mV 27 mV 45 mV 90 mV
7.6% + 18 mA 9.2 mA
1.5% + 5.5 mA 3.2 mA 1.4 mA
Current Monitor (+IM):*
7.7% + 65 mA 32 mA
1.6 % + 8.1 mA 7.1 mA 1.8 mA
*Referenced to supply outputDrift Temperature Stability (following a 30-minute warmup, change in output over 8 hours under constant line, load,
and ambient temperature)
Voltage: 0.02% +
Current: 0.02% +
Temperature Coefficients (change per °C)
0.4 mV 1 mV 2 mV 3 mV 6 mV
16 mA 6 mA 3 mA 2 mA 1 mA
Voltage:
+Current:
Voltage Readback:
+Current Readback:
--Current Readback:
Overvoltage Protection (OVP):
Analog Programming (VP):
Analog Programming (IP):
Current Monitor (+IM):
Maximum Input Power:
60 ppm + 0.1 mV 0.2 mV 0.3 mV 0.5 mV 1.1 mV
95 ppm + 0.82 mA 0.41 mA 0.18 mA 0.12 mA 0.04 mA
60 ppm + 0.2 mV 0.5 mV 0.75 mV 1.3 mV 2.6 mV
95 ppm + 1.2 mA 0.62 mA 0.33 mA 0.20 mA 0.08 mA
110 ppm + 1.2 mA 0.62 mA 0.33 mA 0.20 mA 0.08 mA
200 ppm + 1.6 mV 3.3 mV 5 mV 13 mV 24 mV
60 ppm + 0.1 mV 0.25 mV 0.4 mV 0.7 mV 1.25 mV
90 ppm + 0.56 mA 0.28 mA 0.17 mA 0.1 mA 0.04 mA
75 ppm + 0.61 mA 0.3 mA 0.06 mA 0.06 mA 0.02 mA
480 VA; 400 W, 60 W with no load
Notes: 1For Performance Specifications, see Table 1-la.
:
General Information 21
Table 1-lb. Supplemental Characteristics for Series 664xA (continued)
1
Parameter Agilent Model Number
6641A 6642A 6643A 6644A 6645A
Maximum AC Line Current Ratings
100 Vac nominal:
120 Vac nominal:
220 Vac nominal:
230 Vac nominal:
240 Vac nominal:
Maximum Reverse Bias Current:
With AC input power applied and the dc output reverse
biased by an external dc source, the supply will continuously
4.4 A rms
3.8 A rms
2.2 A rms
2.1 A rms
2.0 A rms
withstand without damage a current equal to its output
current rating (see Table 1- 1a).
Remote Sensing Capability
Voltage Drop Per Lead:
Load Regulation:
Load Voltage:
Up to 1/2 of rated output voltage.
Add 3 mV to spec (see Table l-la) for each l-volt change in
the + output lead due to load current changes.
Subtract voltage drop in load leads from specified output
voltage rating.
Command Processing Time (Average time for output voltage to change after receipt of digital data when the supply
is connected directly to the GPIB Bus):
20 ms
Downprogrammer Current Capability (± 15%):
5.8 A 2.5 A 1.5 A 0.9 A 0.75 A
Output Voltage Programming Response Time
Rise/Fall Time (time for output to change from 90 % to 10% or from 10% to 90% of its total excursion):
<15 ms
Settling Time (time for output change to settle within 1 LSB (0.025% x rated voltage) of its final value):
Monotonicity:
Auto-Parallel Configuration:
<60 ms
Output is monotonic over entire rated voltage, current, and
temperature range.
Up to 3 identical models
Analog Programming (IP & VP)
Input Signal:*
Input Impedance:
*Signal source must be isolated.
Current Monitor Output (+IM):
Savable States
Nonvolatile Memory Locations:
Nonvolatile Memory Write Cycles:
Prestored State (factory default):
10 kΩ, nominal
0 to -5 V represents zero to full-scale current output
5 ( 0 through 4)
0 to -5 V
40,000, typical
Location 0
Notes: lFor Performance Specifications, see Table l-la.
General Information22
Table 1-1b. Supplemental Characteristics for Series 664xA (continued)
Readback Accuracy (from front panel or over GPIB with respect to actual output @ 25 ± 5 °C)
Voltage: 0.07% + 6 mV 15 mV 25 mV 40 mV 80 mV+Current 0.15% + 67 mA 26 mA 15 mA 7 mA 3 mA
-Current 0.35% +
100 mA 44 mA 24 mA 15 mA 7 mA
Load Regulation (change in output voltage or current for any load change within ratings)
Voltage:
Current:
1 mV 2 mV 3 mV 4 mV 5 mV
2 mA 1 mA 0.5 mA 0.5 mA 0.5 mA
Line Regulation (change in output voltage or current for any line change within ratings
Voltage:
Current:
0.5 mV 0.5 mV 1 mV 1 mV 2 mV
2 mA 1 mA 0.75 mA 0.5 mA 0.5 mA
Transient Response Time (for the output voltage to recover to its previous level (within 0.1% of the rated voltage or
20 mV, whichever is greater) following any step change in load current up to 50% of the rated current.
< 100 µs
AC Input Ratings (selectable via internal switching - see Appendix B)Nominal line voltage 100,120,220,240 Vac: 230 Vac:
F requency range:
-13%, +6 %
-10%, +10%
47-63 Hz
Output Terminal Isolation
±240 Vdc (maximum, from chassis ground)
Notes: 1For Supplemental Characteristics, see Table 1-2b.
General Information 25
Table 1-2b. Supplemental Characteristics for Series 665xA
1
Parameter Agilent Model Number
6651A 6652A 6653A 6654A 6655A
Output Programming Range (maximum programmable values)
Voltage:
Current:
Overvoltage Protection (OVP):
8.190 V 20.475 V 35.831 V 61.425 V 122.85 V
51.188 A 25.594 A 15.356 A 9.214 A 4.095 A
8.8 V 22.0 V 38.5 V 66.0 V 132.0 V
Average Resolution
Voltage:
Current:
Overvoltage Protection (OVP):
2 mV 5 mV 10 mV 15 mV 30 mV
15 mA 7 mA 4 mA 2.5 mA 1 mA
13 mV 30 mV 54 mV 93 mV 190 mV
Accuracy
Overvoltage Protection (OVP):*
Analog Programming (VP):*
0.36% +
Analog Programming (IP):*
160 mV 400 mV 700 mV 1.2 V 2.4 V
6 mV 15 mV 27 mV 45 mV 90 mV
7% + 75 mA 31 mA 16 mA 8 mA 5 mA
Current Monitor (+IM):*
7% + 730 mA 400 mA 120 mA 80 mA 75 mA
*Referenced to supply outputDrift Temperature Stability (following a 30-minute warmup, change in output over eight hours under constant line,
load, and ambient temperature)
Voltage: 0.02% +
Current: 0.02% +
Temperature Coefficients (change per °C)
0.4 mV 1 mV 2 mV 3 mV 6 mV
40 mA 15 mA 8 mA 5 mA 2.5 mA
Voltage:
+Current:
Voltage Readback:
+Current Readback:
-Current Readback:
Overvoltage Protection (OVP):
Analog Programming (VP):
Analog Programming (IP):
Current Monitor (+IM):
Maximum Input Power
60 ppm + 0.1 mV 0.2 mV 0.3 mV 0.5 mV 1.1 mV
90 ppm + 1.4 mA 0.7 mA 0.3 mA 0.2 mA 0.2 mA
60 ppm + 0.2 mV 0.5 mV 0.75 mV 1.3 mV 2.6 mV
90 ppm + 1.7 mA 0.9 mA 0.5 mA 0.3 mA 0.2 mA
105 ppm + 1.7 mA 0.9 mA 0.5 mA 0.3 mA 0.2 mA
200 ppm + 1.6 mV 3.3 mV 5 mV 13 mV 24 mV
60 ppm + 0.1 mV 0.25 mV 0.4 mV 0.7 mV 1.25 mV
90 ppm + 1.4 mA 0.7 mA 0.3 mA 0.2 mA 0.15 mA
80 ppm + 1.4 mA 0.7 mA 0.3 mA 0.2 mA 0.15 mA
1380 VA; 1100 W, 120 W with no load
Notes: 1For Performance Specifications, see Table 1-2a.
General Information26
Table 1-2b. Supplemental Characteristics for Series 665xA (continued)
1
Parameter Agilent Model Number
6651A 6652A 6653A 6654A 6655A
Maximum AC Line Current Ratings
100 Vac nominal:
120 Vac nominal:
220 Vac nominal:
230 Vac nominal:
240 Vac nominal:
Maximum Reverse Bias Current:
12 A rms (15 AM fuse)
10 A rms (12 AM fuse)
5.7 A rms (7 AM fuse)
5.5 A rms (7 AM fuse)
5.3 A rms (7 AM fuse)
With AC input power applied and the dc output reverse
biased by an external dc source, the supply will continuously
withstand without damage a current equal to its output
current rating (see Table 1- 2a) .
Remote Sensing Capability
Voltage Drop Per Lead:
Load Regulation:
Load Voltage:
Up to 1/2 of rated output voltage.
Add 3 mV to spec (see Table l-2a) for each l-volt change in
the + output lead due to load current changes.
Subtract voltage drop in load leads from specified output
voltage rating.
Command Processing Time (Average time for output voltage to change after receipt of digital data when the supply
is connected directly to the GPIB Bus):
20 ms
Downprogrammer Current Capability (± 15%):
11.6 A 5 A 3 A 1.8 A 1.5 A
Output Voltage Programming Response Time
Rise/Fall Time (time for output to change from 90 % to 10% or from 10% to 90% of its total excursion):
<15 ms
Settling Time (time for output change to settle within 1 LSB (0.025% x rated voltage) of its final value):
Monotonicity:
Auto-Parallel Configuration:
Output is monotonic over entire rated voltage, current, and
temperature range.
Up to 3 identical models
<60 ms
Analog Programming (IP & VP)
Input Signal:*
Input Impedance:
*Signal source must be isolated.
Current Monitor Output (+IM):
Savable States
Nonvolatile Memory Locations:
Nonvolatile Memory Write Cycles:
Prestored State (factory default):
10 kΩ, nominal
0 to -5 V represents zero to full-scale current output.
5 ( 0 through 4)
0 to -5 V
40,000, typical
Location 0
Notes: lFor Performance Specifications, see Table l-2a.
General Information27
Table 1-2b. Supplemental Characteristics for Series 665xA (continued)
Readback Accuracy (from front panel or over GPIB with respect to actual output @ calibration temp1 ± 5 °C)
Voltage: 0.05% + 12 mV 30 mV 50 mV 90 mV 180 mVCurrent: 0.1% + 150 mA 100 mA 60 mA 35 mA 18 mALoad Regulation (change in output voltage or current for any load change within ratings)
Voltage: 0.002% +
Current: 0.005% +
300 µV 650 µV
10 mA 7 mA 4 mA 2 mA 1 mA
1.2 mV 2 mV 4 mV
Line Regulation (change in output voltage or current for any line change within ratings
Voltage: 0.002% +
Current: 0.005% +
300 µV 650 µV
10 mA 7 mA 4 mA 2 mA 1 mA
1.2 mV 2 mV 4 mV
bisep>
Transient Response Time (for the output voltage to recover to its previous level (within 0.1% of the rated voltage or
20 mV, whichever is greater) following any step change in load current up to 50% of the rated current.
< 900 µs
AC Input Ratings (selectable via internal switching - see Appendix B)
Nominal line voltage
200 Vac:*
*below 185 Vac, derate output voltage
7.8 V 18.0 V 31.5 V 56.5 V 108 V
174-220 Vac
linearly to :
230 Vac:
F requency range:
191-250 Vac
47-63 Hz
Output Terminal Isolation
±240 Vdc (maximum, from chassis ground)
Notes: 1For Supplemental Characteristics, see Table 1-3b.
General Information30