ROOM AIR CONDITIONER
INSTALLATION MANUAL
(Split Type)
Please read this installation manual completely
before installing the product.
When the power cord is damaged, replacement
work shall be performed by authorized personnel
only.
Installation work must be performed in accordance
with the national wiring standards by authorized
personnel only.
Contact the authorised service technician for
repair or maintenance of this unit.
CONTENTS
SAFETY PRECAUTIONS...................................................................2
INSTALLATION OF INDOOR AND OUTDOOR UNITS.......................3
ELECTRICAL WORK ........................................................................10
AIR PURGING ..................................................................................
TEST RUNNING...............................................................................
WARNING
!
Do not install, remove and reinstall the unit by yourself.
Improper installation will cause water leakage, electrical shock,
or fire. Please consult authorized dealer or specialist for the
installation work. Please note fault caused by improper
installation is not covered by warranty.
Unit must be installed in an easily accessible area. Any
additional cost required to hire a special equipment to
service the unit will be the responsibility of the customer.
13
15
1
Contents
SAFETY PRECAUTIONS
The following should be always observed for safety:
Be sure to read the following WARNING before installing the air
conditioner.
Be sure to observe the cautions specified here as they include
important items related to safety.
After reading this instructions, be sure to keep it together with the
owners manual in a handy place for future reference.
WARNING
!
Do not install it yourself.
Incorrect installation could cause injury due to fire,
electric shock, the unit falling or leakage of water.
Consult the dealer from whom you purchased the
unit or special installer
Install the unit securely in a place which
can bear the weight of the unit.
When installed in an insufficiently strong place,
the unit could fall causing injury.
Use the specified wires to connect the
indoor and outdoor units securely and
attach the wires firmly to the terminal
board connecting sections so the stress
of the wires is not applied to the sections
Incorrect connection and fixing could cause a fire.
Be sure to use the part provided or
specified parts for the installation work.
The use of defective parts could cause an injury
due to a fire, electric shock, the unit falling, etc.
Perform the installation securely referring
to the installation instruction.
Incorrect installation could cause a personnel
injury due to fire, electric shock, the unit falling
or leakage of water.
Perform electrical work according to the
installation manual and be sure to use an
exclusive circuit.
If the capacity of the power circuit is insufficient
or there is incomplete electrical work, it could
result in a fire or an electric shock.
Check that the refrigerant gas does not
leak after installation is completed.
Attach the electrical part cover to the indoor unit and
the service panel to the outdoor unit securely.
If the electrical part covers of the indoor unit
and/or the service panel of the outdoor unit
are not attached securely, it could result in a
fire or electrical shock due to dust, water, etc.
Do not install the unit in a place where
a flammable gas leaks.
If gas leaks and accumulates in the area
surrounding the unit, it could cause a
explosion.
Safety precautions
2
!
CAUTIONS
Perform the drainage/piping work according to the
installation instruction.
If there is a defect in the drainage/piping work,
water could leak from the unit and household
goods could get wet and be damaged.
INSTALLATION OF INDOOR AND OUTDOOR UNITS
Read completely, then follow step by step.
More than 15cm
Indoor unit
Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles
in front or around the unit.
Make sure that condensation drainage can
be conveniently routed away.
Do not install near a doorway.
Ensure that the space on the left and right
of the unit is more than 12cm.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.
A minimum pipe run of 3 metres is required to minimise vibration & excessive noise.
The indoor unit should be installed on the wall at a height of 2.3 metres or more
from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from
the ceiling.
Any variations in pipe length will/may require adjustment to refrigerant charge.
More than 12cm
More than 12cm
More than 2.3m
Fig.1
Outdoor unit
If an awning is built over the outdoor unit to
prevent direct sunlight or rain exposure,
More than 30cm
make sure that heat radiation from the
condenser is not restricted.
Ensure that the clearance around the back
of the unit is more than 30cm
more than 30cm
. The front of the unit should
have more than 200cm of clearance and the
and left side is
More than 200cm
Fig.2
connection side (right side) should have more
than 60cm of clearance.
Do not place animals and plants in the path of the air inlet or outlet.
Take the air conditioner weight into account and select a place where noise
and vibration will not be an issue.
Select a place so that the warm air and noise from the air conditioner do not
disturb neighbors.
Rooftop installation:
If the outdoor unit is installed on a roof structure, be sure to level the unit.
Ensure the roof structure and anchoring method are adequate for the unit
location.
Consult local codes regarding rooftop mounting.
If the outdoor unit is installed on roof structures or external walls, this may
result in excessive noise and vibration, and may also be classed as a non
serviceable installation.
More than 60cm
More than 60cm
Installation Instruction
3
Items packed with the unit
Number
1
2
3
4
5
6
7
8
9
Name of Accessories
Installation Plate
Clip Anchor
Self-tapping Screw A ST3.9X25
Seal
Drain Joint
Liquid side
Connecting pipe
Assembly
Gas side
Remote controller
Self-tapping Screw B ST2.9X10
Remote controller holder
6.35
9.53
12.7
( 9000Btu/h)
( 9000Btu/h)
Qty
1
8
8
1
1
Parts you
must
purchase
1
2
1
Note: Except the above parts provided, the other parts needed during installation you
must purchase.
Mounting screwA
12cm above
3
Clip Anchor
2
15cm above
1
Installation plate
CAUTION
Install the indoor unit on the wall
where the height from the floors
more than 2.3 meters.
12cm above
A minimum pipe run of 4 to 5
meters is required to minimize
vibration and excessive noise.
6
Two of the A,B,C directions
should be free from blocking.
Air Filter
A
30cm above
B
Installation Instruction
4
Air Outlet
200cm above
Fig.3
60cm above
30cm above
60cm above
C
AUTO
Loop the
connective
cable.
COOL
DRY
7
HEAT
TEMP
MODE ON/OFF
SWING
ECONONY
LOCK
RESET
R
DIGITALDISPLAY
Remote Controller
FAN
HIGH
MED
LOW
FAN
TIMER
CANCEL
Mounting screw B
ST2.9x10-C-H
8
Remote controller
holder
9
This illustration is for explanation purposes only.
The actual shape of the installation plate will be
different depending on the models.
Copper lines must be insulated independently