X -- DENOTES FIELD
WIRE SPLICE
PRODUCT MUST BE INSTALLED
ACCORDING TO ALL APPLICABLE
BUILDING AND LIFE SAFETY CODES
CONTROL SWITCH (N.O.) (EX. PUSHBUTTON)
(KEYPAD) (CARD READER)
DRY CONTACTS !
4605/4606 24 VAC 40 VA TRANSFORMER (12 VAC BY OTHERS)
RED
120 VAC
LINE
VOLTAGE
RED
4603
2 AMP
RECTIFIER
WHITE |
X |
|
|
(+) |
|
|
D1 |
24 VDC BLACK (-)
|
|
HINGE EDGE |
|
|
|
OF DOOR |
|
4612 WIRE |
EL ELECTRIFIED |
C |
|
TRANSFER |
|||
|
|
EXIT DEVICE |
L |
X |
|
|
|
X |
X |
REFER TO EXIT DEVICE |
|
|
TEMPLATE FOR BAR HEIGHT |
||
|
|
NOT SUPPLIED |
|
|
|
MAY USE 1N4004 |
|
YELLOW |
|
TO PREVENT ARCING |
12 VDC |
||
YELLOW |
|||
IN SWITCH.75000000 |
|
|
24 VDC BLACKBLACK
FIG. 1
ELECTRIC LATCH RETRACTION WIRING SCHEMATIC
BLUE BLUE (N.O.)
MONITOR SWITCH
A SINGLE POLE SINGLE THROW MONITOR SWITCH IS ADDED TO THE SOLENOID. INDICATE WHEN THE UNIT IS ELECTRICALLY UNLATCHED. SWITCH OUTPUTS CAN BE USED TO SIGNAL AUTOMATIC DOOR OPERATORS, MONITOR PANELS, FIRE CONTROL PANELS ETC.
DOOR PREPARATION
FIG. 2
.375
FOR WIRING ACCESS
TO LOCATED AND PREPPED AT INSTALLATION
C
L
REFER TO EXIT DEVICE
TEMPLATE FOR BAR HEIGHT
EXIT DEVICE MOUNTING HOLES |
|
(REFER TO EXIT DEVICE TEMPLATE) |
WIRE SIZING FIG. 3 |
|
www.adamsrite.com
Phone: 800-626-7590 800-872-3267
Fax: 866-582-4641
800-232-7329
3700EL/8700EL/8800EL |
|
ELECTRIC LATCH RETRACTION |
|||
RIM EXIT DEVICES |
|
INSTALLATION INSTRUCTIONS |
|||
80-0180-268 |
Rev. J |
ECN: 11955C |
Date: 07-18-12 |
Page 1of 2 |
Appvd: MP |