00683A3 INST01102-06
6 MULTIPLE WIRELESS SENSORS
The main unit supports up to three wireless sensors. Each additional wireless sensor
must be designated a different channel number. Assigning different channel numbers
differentiate each sensors temperature and hygrometer readings for the main units’
display. The included wireless sensor is automatically channel # 1.
Additional wireless sensors are sold seperately. Call 1-800-556-2548 to order.
1) Open each sensor by separating the front and back pieces
3) Use the interior slide switch to select a channel
NOTE: use channel #2 and/or #3. Channel #1 is already taken by the included
wireless sensor.
6) Press the TX button to send a signal to the main unit.
7) Snap the front and back pieces together.
8) Mount the sensor. See section 3 for placement of the remote sensor unit.
7 TROUBLESHOOTING
---
Problem:
is displayed as the wireless sensor temperature (OUT).
Possible solutions:
•Move sensor away from interference (electrical devices, metal surfaces, etc.).s
•Batteries may need replacing.
•Sensor could be out of range (more than 100 feet from the main unit). Place the sensor
closer to the main unit.
Problem: The temperature shown for “OUT” (wireless sensor) seems to be inaccurate
Possible solutions:
•The wireless sensor will not send an outdoor temperature reading if it is not placed
outdoors. Be sure that the wireless sensor is placed outdoors.
•Make sure that the wireless sensor is out of direct sunlight or direct weather elements,
these locations may cause inaccurate readings
•Reset both units by removing all batteries and re-installing them (see section 2).
Instruction Manual
Wireless Thermometer
MODEL # 00683A3
CH
MIN /MAX
CLEAR
WI RE LE SS
Main Unit Wireless Sensor
Thank You! We appreciate you for purchasing this wireless thermometer.
We hope you enjoy using this versatile wireless thermometer!
WI RE LE SS
Do not return product to retail store. For Technical Assistance and
product return information, please call Customer Care:
877-221-1252
HOURS: Monday through Friday from 8:00 a.m. to 4:45 pm CST.
PLEASE DISPOSE OF OLD
OR DEFECTIVE BATTERIES
IN AN ENVIRONMENTALLY
SAFE WAY IN ACCORDANCE
WITH LOCAL REGULATIONS
Features:
• Main unit with indoor and outdoor LCD temperature display.
• Wireless Sensor – range is 100’ (33m).
• Temperature measurement ranges:
Indoor main unit: +32º F to +122º F
Outdoor wireless sensor: -4º F to +158º F
• Battery operated. (batteries not included)
1 CHECK PACKAGE CONTENTS
(1) Main unit - dimensions: 2.75" x 3.5" x 1" (7 cm x 9 cm x 2.5 cm)*
(1) Wireless Sensor – dimensions: 2.5" x 3.5" x 1" (6.4 cm x 9 cm x 2.5 cm)*
(3) 1" (2.5cm) screws with plastic anchor
(1) Instructions
*Dimensions are approximate.
NOTE: Carefully remove the units from their packaging. Discard the packaging and
save the instructions.
2 READ
Please read these instructions carefully before you set up the thermometer. In this
way you can become familiar with all of the thermometer’s features and get the most
benefit from them.
3 INSTALLATION & SET UP
Operating Range of Batteries
LITHIUM
BATTERIES
ALKALINE
BATTERIES
(-30ºC) (70ºC)
-22ºF 158ºF
-4ºF 158ºF
(-20ºC)
(70ºC)
Severe cold (below -4º F/-20º C) can cause alkaline
batteries to freeze and function improperly. Use lithium
batteries in extremely low temperature conditions to
ensure continued operation.
Main Unit
The Main unit is intended for indoor use only. When deciding where to put the main unit,
choose a dry location away from dust, dirt, mold and smoke, and avoid temperature
extremes. Do not drop the main unit. It is a sensitive electronic device, and is not designed
to withstand high impact blows.
NOTE: Install batteries in the MAIN UNIT before putting batteries in the wireless
sensor.
Main Unit Batteries: On the back of the unit, remove the battery compartment cover.
Insert 2 AA alkaline (or lithium) batteries making sure they are installed according to the
correct polarity (+/-). Replace the cover.
Wireless Sensor
This water resistant wireless sensor is intended for outdoor use. When deciding where to
place the sensor, make sure it will be protected from direct sunlight and from precipitation.
Do not drop the remote sensor. It is sensitive, and not designed to withstand high impact
blows.
Wireless Sensor Batteries: On the back of the wireless sensor unit, remove the battery
compartment cover. Insert 2 AAA alkaline (or lithium) batteries making sure they are
installed according to the correct polarity (+/-). Replace the cover.
You may need to wait a few minutes after batteries are installed for the units to communicate with each other. When they do, both the indoor and outdoor temperatures will be
shown on the main unit LCD display. If nothing is displayed, refer to section 4 of this
manual for troubleshooting.
NOTE: The sensor’s LED flashes momentarily whenever it sends information – about once
each minute.
Main Unit
ALERT
+
-
C/F
enlargement
of back function
buttons
Wireless Sensor
TX C/F
To access the battery
compartment and the
function buttons, open the
case along the seam.
AA
AA
AAA
AAA
Placement & Mounting
Choose a location for each
unit that is at least 10 feet away
from other electronic devices
that may interfere with the
wireless signal.
4 USING the MAIN UNIT FEATURES
Choose a Temperature Scale
Press the + / C/F button to select either Fahrenheit or Celsius as your temperature scale.
View High and Low Temperatures Held in Memory
Press the MIN/MAX button once to view the maximum inside and outside temperatures
that are held in the main unit's memory.
While the maximum temperatures are displayed, press the MIN/MAX button again to view
the minimum temperatures.
Clearing Memory - Press the CLEAR button while the value you want to clear (MAX or
MIN) is displayed.
Temperature Alert
NOTE:This feature is available for the wireless sensor temperature display.
When the alert feature is on, and a preset alert temperature is reached, an alert is
signaled. This signal can be heard and seen. It consists of three short beeps while on the
main unit display the temperature and the upper/lower icons are flashing.
To stop the alarm - press any button. The temperature will continue to flash until it
changes (from either the higher or lower temperature alerts that were set).
To set minimum and maximum temperature alerts:
1)Press the ALERT button once to turn on the feature. You will see the
upper/lower icon flashing at the top of the main unit display.
2)Press ALERT until the outdoor temperature and the upper/lower icon flash.
Press the + or - buttons to select the desired channel. Press ALERT to confirm
the channel selection.
3)The upper pointer and temperature begin to flash. Enter the desired upper l
limit temperature (See 9 for temperature range.) by pressing the + or - buttons.
Press ALERT to confirm the setting.
4)The lower pointer begins to flash. Enter the desired minimum temperature
with the + or - buttons. Press ALERT to confirm the setting.
View Multiple Wireless Sensor Temperatures with Auto Scroll
When there is more than one remote sensor, pressing the - / button starts the auto
scroll. The icon appears under the channel number showing that auto scroll has been
turned on. The display shows the remote sensor temperature from each channel scrolling
continually from one channel to the next. See section 6 for more information.