REFERENCE MANUAL
Acu-Rite Companies Inc.
Page 2
Page 3
SENC 50 Table of Contents
Page
Introduction / Supplied items ............................................... 2
Key Points / Tolerances ......................................................... 3
Linear Encoder Dimensions.................................................. 4
Spar Dimensions .................................................................... 5
Typical Mounting ................................................................... 7
Encoder Installation Procedure ............................................ 8
Page
Checking the Installation.................................................... 10
Electrical Shielding.............................................................. 11
Troubleshooting ................................................................... 12
Mechanical Specifications ................................................... 13
Output Signals and Pin-Outs.............................................. 14
Electrical Specifications ...................................................... 15
The Acu-Rite Companies Inc.
Hassle Free Warranty & Service ........................................ 16
Spar
Front mount
bracket
Bottom mount
bracket
Adjustable front or
rear mount
Front mount
bracket
Base mount
• Installation brackets and kits are available.
• Your Authorized Distributor can assist you in selecting brackets and tools for your installation.
1 Acu-Rite Companies Inc.
Page 4
Introduction / Supplied Items SENC 50
The SENC 50 Precision Glass Scale Linear Encoder provides the accuracy and reliability of an Acu-Rite Companies Inc. measuring system in a very small cross-section with digital output (analog output available). Features and options include:
• Resolutions of 0.5, 1.0 or 5µm.
• Accuracy grades of ± 3 or ± 5 µm / 1000mm.
• Position Trac or 50mm interval Reference Mark.
• Vinyl or Armor cables of 5, 13, & 19 ft. lengths.
• Mounting fasteners, center supports, and backup spar.
• Installation tools, brackets, and accessories. The SENC 50 is especially useful for applications with limited space such as X/Y stages and compact metrology equipment. Contact your Authorized Distributor for assistance with selection of product options and accessories.
Shipping carton
contents
A
C
For future ordering information or warranty service, record the linear encoder catalog and serial numbers.
Catalog # Serial # Manufacture Code # Axis # 1: _____________________________________ Axis # 2: _____________________________________ Axis # 3: _____________________________________ Axis # 4: _____________________________________
Date of Purchase _____________________________________ Distributor: _____________________________________ Address: _____________________________________
Telephone: _____________________________________
B
A) SENC 50 linear encoder B) Reference Manual C) Encoder and Cable
Mounting Hardware
Acu-Rite Companies Inc. 2
Page 5
SENC 50 Key Points / Tolerances
Use this information to plan your Linear Encoder installation.
// .005 A
// .005 B
• Understand your mounting requirements.
• Follow kit instructions when using an Acu-Rite Companies Inc. bracket kit.
• Mount encoders close to ways to insure system accuracy.
• Mount with lip seals down and away from the work area.
• Brackets should be short and rigid.
• Surfaces must be in good condition, clean and free of dirt and paint.
Do not remove shipping brackets until instructed.
• Shipping bracket spacers can be used to insure .059” gap.
-A- = Machine travel Center support surface
Reading head
assembly
Equal
required
// .005 A
Equal
Gap
.059 ±.005”
[1.50]
Scale assembly
// .005 A
// .005 A
B
• Mount from either side to obtain desired cable exit direction.
• Tolerances of .005” TIR apply to all mounting dimensions.
Center support surface required for all measuring
lengths when not using a back up spar.
1.00
Shipping bracket removal clearance
Slide brackets away
from the reading head
1.00
Total head travel
.26 [6.6]
Min.
Measuring length + 1”
[25.4] over travel
.037 [.9]
Min.
• Limit equipment travel to less than measuring length.• Allow clearance for shipping bracket removal.
3 Acu-Rite Companies Inc.
Page 6
Linear Encoder Dimensions SENC 50
.280
[7.11]
Typ.
End cap
.140
[3.55]
.175 [4.57]
.295
[7.50]
Typ.
Reading
head
assembly
.463
[11.76]
.213
[5.41]
Typ.
M3 x .25 [6.31]
deep min.
Measuring length + 4.65 [118]
Measuring length + 4.09 [103.9]
Scale assembly
for M4
Hex nut
Scale case
Mounting hole
Strain relief
1.85
[47.00]
2.775
[70.50]
[4.00] min.
2.350
[59.69]
[3.81]
.138
[3.50]
and cable
Ø .160
.150
.335
[8.51]
Ø .30
[7.6]
Armor
2.0 [50] Approx. min bend radius
of armor
.280
[7.11]
.159
[4.04] Typ.
Ø .16
[4.1]
Vinyl
.670
[17.00]
1.182
[30.00]
Align both
surfaces
.02
[0.5]
1.352 [34.34]
.652
[16.56]
.482
[12.25]
.Gap
.059 ± .005
[1.50]
.170
[4.32]
.840
[21.34]
Spar
.170
[4.32]
Acu-Rite Companies Inc. 4
Page 7
SENC 50 Spar Dimensions
Backup spar Linear Encoder L A X No. B
Part Number Measuring Length Places
680803-01 1 5.650 .825 2 4.000 680803-02 2 6.650 .825 2 5.000 680803-03 3 7.650 1.325 2 5.000 680803-04 4 8.650 1.825 2 5.000 680803-05 5 9.650 2.325 2 5.000 680803-06 6 10.650 2.825 2 5.000 680803-07 7 11.650 3.325 2 5.000 680803-08 8 12.650 3.825 2 5.000 680803-09 9 13.650 1.825 3 5.000
Encoder
retaining clip
Spar
fastener
Spar leveling
screws
Backup spar Linear Encoder L A X No. B
Part Number Measuring Length Places
680803-10 10 14.650 2.325 3 5.000 680803-11 11 15.650 2.825 3 5.000 680803-12 12 16.650 3.325 3 5.000
680803-13 13 17.650 3.825 3 5.000 680803-14 14 18.650 1.825 4 5.000 680803-15 15 19.650 2.325 4 5.000
680803-16 16 20.650 2.825 4 5.000 680803-18 18 22.650 1.325 3 10.000
680803-20 20 24.650 2.325 3 10.000
Backup spar mounting optional for all lengths
Backup spar
mounting
Clip mounting
screws
.510
.330
.075
Ø .196 Drill thru
Ø .344 C’bore x .100 Dp.
“X” no. of places
“A”
± .005
Non accumulative
B Typ. ±.005
“A”
Ref.
±.015
L
5 Acu-Rite Companies Inc.
Page 8
Mounting Requirements SENC 50
Mounting options can be adapted to machine mounting surfaces using spacers, standoffs, and leveling screws.
• Measuring length and mechanical configuration of your equipment determines your options.
• Length related mounting options shown.
• When a backup spar is used, mount the backup spar following the same procedure as required for mounting without a backup spar, using the same tolerances.
End mounting holes
Center support
assembly
• 8” and larger: End mounting holes with center support.
• 7” and smaller: End mounting holes with encoder mounted to a continuous flat surface, or with center surface on same plane as end mounting surfaces.
Acu-Rite Companies Inc. 6
Page 9
SENC 50 Typical mounting
A variety of mounting conditions can be accommodated.
• Mechanical configuration of the equipment determines brackets and adapters required to install the linear encoder.
• Three typical conditions are shown for reference.
Flush mounting surfaces
// .005
Spar mounting
// .030
• Flush or offset mounting surfaces using a spar.
• Reading head mounting bracket required (bottom mounting bracket example shown).
Offset mounting surfaces
// .030
• Mounting surfaces are flush within .005”.
• Installation without a backup spar.
• Offset mounting surfaces using a reading head bracket.
7 Acu-Rite Companies Inc.
Page 10
Encoder Installation Procedure SENC 50
These steps apply to all mounting conditions. Although this may not pictorially represent your application, your installation procedure should follow these steps.
Acu-Rite Companies Inc. Bracket Kit instructions
supercede this section.
• General steps for small X & Y stage.
• Adjust drill depths and fastener lengths as required.
• Contact your Authorized Distributor if assistance is required.
Keep head and
Scale case
Shipping
brackets (2)
C
L
Reading head
scale case
surfaces flush
Strain relief
and
cable assembly
Center mounting axis
C
Mark center of axis
• Center the axis.
• Mark the axis for easy return to center.
Underside of end caps to be
flush with parting line of
upper slide.
End cap
Align top of scale case to
within .015” of axis travel
Mark end mounting
L
Scale case
hole location
• Center the reading head on the scale case by sliding the head and shipping brackets together along the scale case.
Acu-Rite Companies Inc. 8
• Locate the linear encoder along the axis parting line.
• Mark location of one end mounting hole in the scale case.
Page 11
SENC 50 Installation Procedure
Axis
travel
Align to within
.005”
to axis travel
Drill / tap for 6-32
(M3).
Use shipping brackets
to maintain .059
gap between
head and
scale case.
Drill / tap
for 6-32 (M3).
6-32 x 3/4” SHCS & M3
flat washer (M3 x 20mm)
• Drill / tap the first end mounting hole / Attach the scale case.
• Align to within .005” TIR. and drill / tap second end hole.
• Attach scale case & align to within .005” TIR. of the axis travel.
6-32 x 3/4” SHCS & M3 flat washer
(M3 x 20mm)
Retaining clip
Center support
• Use center supports when provided.
• Place at uniform intervals along the scale case.
C
L
6-32 x 3/4” SHCS & M3
flat washer (M3 x 20mm)
• Center the axis and mark the reading head mounting holes.
• Move the axis and drill / tap holes for 6-32 (M3).
• Attach head and align to scale case to within .005” TIR.
Slide bracket from reading head
and twist 45°
Shipping bracket
(2)
• Slide shipping brackets from reading head and twist to remove from the scale case.
• Save the shipping brackets with the Reference Manual.
9 Acu-Rite Companies Inc.
Page 12
Checking the Installation SENC 50
Connecting
Provide slack
loops
These steps will confirm proper operation of your installation. Counting tests check channel A and B output function and Reference Mark tests check Reference Mark operation.
• Configure the readout for proper counting resolution.
• Move axis and compare the display to the movement.
• Repeat test for mechanical integrity and repeatability.
• Configure the readout for sensing reference mark.
• Move the reading head approximately 20mm.
Secure excess
cable
• Locate an indicator on scale end and zero out axis and indicator.
• Move axis out and back over full travel and return to dial
• Route the cables with slack loops to allow for axis motion.
• Secure excess cable by fastening with clips or ties.
zero.
• Electronics should read zero ± 1 count.
• Attach the linear encoder connectors to the readout.
Counting Test
Readout
• Check function of the linear encoder.
Acu-Rite Companies Inc. 10
Place indicator at end of
moving component (scale case
shown, or reading head).
Repeatability Test
Readout
• Zero the display and indicator.
• Move axis to the end of it’s travel, then return to dial zero.
• Readout should read zero ± 1 count.
Page 13
SENC 50 Electrical Shielding
Connect a ground wire from the terminal on the back of the readout to the machine or earth ground. Attach a ground wire from the machine to a solid earth ground.
With the encoder attached to the machine and the cable connected to the readout, check shielding by measuring resistance between connector housing and scale unit. Desired
value: 1
ΩΩ
Ω max.
ΩΩ
11 Acu-Rite Companies Inc.
Page 14
Trouble Shooting SENC 50
If you experience difficulties with your installation, there are methods to analyze the difficulty. Operating difficulties can be caused by either the linear encoders or the readout.
Checking the readout
Follow the steps below to determine if your difficulties are associated with the readout:
• Insure that the linear encoder connectors are correctly seated.
• Swap linear encoder cables at the readout to see if the problem is still shown in the same display.
• If the problem remains in the same display, the readout is in error.
• If the problem follows the connection change, the linear encoder may be in error.
• Follow this procedure for any intermittent problem experienced.
If the readout is at fault, refer to “What to do” to arrange for the parts necessary to repair your system. If the linear encoders appear to be the cause, perform the next step.
Checking the Linear Encoders
Linear encoder difficulties can be caused by improper installation, loose or misaligned bracketry, or a damaged / failed linear encoder.
Follow the steps below to determine the cause of your system difficulties:
• Confirm that your bracketry and installation does not interfere
with other machine structures through the length of the linear
encoder travel.
• Check for loose fasteners. If you find loose fasteners, first confirm that the linear encoder is installed to the tolerances specified and then retighten the fasteners as required.
• Confirm that the linear encoder is installed to the required tolerances by checking the alignment tolerances specified on Page 3 “Key Points”. If the installation does not meet the tolerances, reinstall the linear encoder according to the procedures in “Installation”.
• Perform a Repeatability Test as described on Page 10, “Checking Your Installation”. If the linear encoder is installed to the required tolerances, the bracketry and linear encoder have been checked for interferences and loose fasteners, and the linear encoder fails the repeatability test, the linear encoder is likely at fault.
Do not attempt to repair the linear encoder. The units are only serviceable by assembly replacement. Attempted repair can permanently damage the unit and void the warranty.
What to do
If an Acu-Rite Companies Inc. linear encoder or readout is found to be at fault, prior to removing the linear encoders or readout contact your Authorized Distributor or OEM/OEI for repair instructions.
Acu-Rite Companies Inc. 12
Page 15
SENC 50 Mechanical Specifications
Mechanical Specifications Digital Analog
Resolution 0.5µm 1µm 5µm
Grating pitch 20µm
Scale medium Light transmission reflective off of chrome coated glass Accuracy (@ 20° C) / 1000mm ± 3µm, ± 5µm
Max. slew speed (M/s) 1
Force required to move < 0.5 (lbs)
reading head Operating Environment
Temperature 0° to 50° C Relative Humidity 20% to 95% (non-condensing)
Storage Environment Temperature - 20° to 70° C Humidity 20% to 95% (non-condensing)
Weight 1.1 + 0.2 lbs/ft of measuring length [64g + 5.6g/in.]
Connecting cable Length = 5, 13, and 19 ft. Length = 5, 13, and 19 ft. armored or vinyl Connector: DE-9P Connector: DE-9P
Max. cable length (ft) 20 26 75
Measuring lengths 1” - 20” Reference pulse interval 50mm fixed or Position Trac
Repeatability Within one resolution count
Operating current (ma) 220 180 75
Protection (IEC 529) IP 53 when installed as per instruction
13 Acu-Rite Companies Inc.
Page 16
Output Signals and Pin-Outs SENC 50
Digital Differential
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9
N/C Green Yellow Pink Red White Black Gray Brown N/C Channel Channel Channel Channel Ground Vcc, + 5.1 Channel Channel
A+ A- B+ B- ± 0.1 VDC R+ R-
1
5
6
9
Analog Differential
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9
White w/Grn Stripe & Brown Green Yellow Orange Red N/C Black Blue Violet
Ground Channel Channel Channel Channel N/C Vcc, + 5.0 Channel Channel
A+ A- B+ B- ± 0.1 VDC R+ R-
Acu-Rite Companies Inc. 14
Page 17
SENC 50 Electrical Specifications
Parameter
Output Signals
Incremental signals
Signal levels
Reference Mark signals
Signal level
Digital
IOH=(High level output current) = 20mA VOH=(High level output voltage) >2.5Vdc
Channel A+
Channel A-
1 0
1 0
Channel R+
Channel R-
360°
90°
Channel B+
Channel B-
1 0
1 0
1 Count
(Phased)
IOL=(Low level output current) = -20mA VOL=(Low level output voltage) < 0.6Vdc
Square-wave voltage signals.
Channels A and B, in 90°
quadrature relationship
TTL-level
Square-wave signal
TTL-level
Analog
90°
360°
1 0
1
Channel B
Channel A
I
:7-16 µA
A, B
or
1.0 V
pp
pp
0
Channel R
IR:2-8 µA
1.2 V
pp
or
pp
Similar phasing, but differential
sinusoidal current or 1 volt peak to peak output
7-16µApp or 1.0 V
pp
w/1 K Ohm load
Differential current or 1 volt peak to peak output
2-8µApp or 1.2 V
pp
w/100 K Ohm load
Power Supply
5.1 ± 0.1 VDC @ 220 mA max.
15 Acu-Rite Companies Inc.
5.0 ± 0.1VDC @ 75 mA max.
Page 18
Acu-Rite Companies Inc. Warranty SENC 50
ACU-RITE Companies, Inc. is proud to offer the 3-Year Hassle-Free Warranty for all readout systems, and precision glass scales. This warranty will cover all of the ACU-RITE repair and replacement costs for any readout or precision glass scale returned during the three (3) year warranty period. ACU-RITE will repair or replace the damaged components regardless of the product’s condition absolutely free, no questions asked. This warranty covers both materials, and factory labor. In addition, authorized ACU-RITE service representatives will provide service labor (field service) for a period of one (1) year at no charge. Notice of the claimed defect must be received by ACU-RITE within the warranty period.
This warranty applies only to products and accessories installed and operated in accordance with this reference manual. ACU­RITE shall have no obligation, with respect to any defect, or other condition caused in whole or part by the customer’s incorrect use, improper maintenance modification of the equipment, or by the repair, or maintenance of the product by any person except those deemed qualified by ACU-RITE.
Responsibility for loss of operation, or diminished performance due to conditions beyond ACU-RITE’s control cannot be accepted by ACU-RITE.
The foregoing warranty obligations are in lieu of all expressed or implied warranties. ACU-RITE Companies, Inc. shall not be liable under any circumstances for consequential damages.
Acu-Rite Companies Inc. 16
Page 19
Page 20
Acu-Rite Companies Inc.Acu-Rite Companies Inc.
Acu-Rite Companies Inc.
Acu-Rite Companies Inc.Acu-Rite Companies Inc.
IS ANIS AN
IS AN
IS ANIS AN
ISO 9001ISO 9001
ISO 9001
ISO 9001ISO 9001
CERTIFIEDCERTIFIED
CERTIFIED
CERTIFIEDCERTIFIED
MANUFMANUF
ACTURERACTURER
MANUF
ACTURER
MANUFMANUF
ACTURERACTURER
Acu-Rite Companies Inc.
One Precision Way • Jamestown, NY 14701
516353-21 Ve00 4/2009
Loading...