Technical Documentation of (EU) No 617/2013
Product type |
|
Desktop computer |
|
|
Product category |
B |
C |
D |
|
Manufacturer name, address |
Acer Italy s.r.l, |
|
|
|
Via Lepetit, 40, 20020 Lainate (MI) Italy |
|
|||
|
|
|||
Product model number |
|
Veriton M2630; |
|
|
|
Veriton M2631. |
|
||
|
|
|
||
|
|
|
|
|
Year of manufacture |
|
2014 |
|
|
ETEC allowance with capability |
|
|
|
|
adjustments when discrete graphics cards |
197 kWh/year |
213 kWh/year |
248 kWh/year |
|
are disabled (from 1 July 2014) |
|
|
|
|
ETEC allowance with capability |
|
|
|
|
adjustments when discrete graphics cards |
266 Watt |
282 kWh/year |
317 kWh/year |
|
are enabled (from 1 July 2014) |
|
|
|
|
ETEC allowance with capability |
|
|
|
|
adjustments when discrete graphics cards |
151 kWh/year |
159 kWh/year |
187 kWh/year |
|
are disabled (from 1 January 2016) |
|
|
|
|
ETEC allowance with capability |
|
|
|
|
adjustments when discrete graphics cards |
189 Watt |
197 kWh/year |
225 kWh/year |
|
are enabled (from 1 January 2016) |
|
|
|
|
Whether all discrete graphics card are |
Yes |
Yes |
Yes |
|
enabled during the test |
||||
|
|
|
||
Whether switchable graphics mode with |
No |
No |
No |
|
UMA is driving the display during the test |
||||
ETEC of highest power-demanding |
156.8 kWh/year |
158.37 kWh/year |
144.6 kWh/year |
|
configuration |
||||
|
|
|
||
Idle state power demand |
41.94 Watt |
43.29 Watt |
39.14 Watt |
|
Sleep mode power demand |
2.82 Watt |
2.55 Watt |
2.69 Watt |
|
Sleep mode with WOL enabled power |
2.91 Watt |
2.63 Watt |
2.78 Watt |
|
demand |
||||
|
|
|
||
Off mode power demand |
0.31 Watt |
0.31 Watt |
0.31 Watt |
|
Off mode with WOL enabled power |
0.31 Watt |
0.31 Watt |
0.31 Watt |
|
demand |
||||
|
|
|
||
|
|
|
|
|
Maximum power demand |
Not applicable |
Not applicable |
Not applicable |
|
Internal power supply (IPS) efficiency at |
10% - 91.14% |
10% - 91.14% |
10% - 91.14% |
|
20% - 93.31% |
20% - 93.31% |
20% - 93.31% |
||
10 %, 20 %, 50 % and 100 % of rated |
||||
50% - 90.89% |
50% - 90.89% |
50% - 90.89% |
||
output power |
||||
100% - 99.04% |
100% - 99.04% |
100% - 99.04% |
||
|
||||
|
|
|
|
|
External power supply's (EPS) average |
Not applicable |
Not applicable |
Not applicable |
|
active efficiency |
||||
|
|
|
||
|
|
|
|
|
Noise levels (the declared A-weighted |
3.2 B |
3.2 B |
3.2 B |
|
sound power level, LWAd) of idle mode |
||||
|
|
|
||
Noise levels (the declared A-weighted |
|
|
|
|
sound power level, LWAd) of "HDD random |
3.2 B |
3.2 B |
3.2 B |
|
seek" mode |
|
|
|
|
|
|
|
|
Minimum number of loading cycles that |
Not applicable |
Not applicable |
Not applicable |
|
the batteries can withstand |
||||
|
|
|
||
Configuration of memory |
2 ~ 16 GB |
2 GB |
4~ 16 GB |
|
Configuration of internal storage |
2 piece |
2 piece |
2 piece |
|
Configuration of discrete television tuner |
0 piece |
0 piece |
0 piece |
|
Configuration of discrete audio card |
0 piece |
0 piece |
0 piece |
|
Configuration of discrete graphics cards |
1 piece |
1 piece |
1 piece |
|
Configuration of discrete graphics cards |
G3 |
G3 |
G3 |
|
category |
||||
|
|
|
||
The battery in this product cannot be |
Not applicable |
Not applicable |
Not applicable |
|
easily replaced by users themselves |
||||
|
|
|
||
For products with an integrated display, |
Not applicable |
Not applicable |
Not applicable |
|
the total content of mercury is |
||||
|
|
|
||
|
COMMISSION REGULATION (EU) No 617/2013 of 26 June |
|||
|
2013 implementing Directive 2009/125/EC of the European |
|||
Measurement methodology for ETEC |
Parliament and of the Council with regard to ecodesign |
|||
requirements for computers and computer servers: |
||||
|
||||
|
ANNEX II Ecodesign requirements and timetable: |
|||
|
1.1.1. ETEC formula. |
|
|
|
|
EN 62623:2013 — Desktop and notebook computers — |
|||
|
Measurement of energy consumption: |
|
||
|
5.2. Test setup; |
|
|
|
Measurement methodology for idle mode |
5.3.5. Measuring short idle mode; |
|
||
5.7. True RMS watt meter specification; |
|
|||
|
|
|||
|
5.8. True RMS watt meter accuracy; |
|
||
|
Annex E.2 (informative) ENERGY STAR® V5 compliant testing |
|||
|
methodology. |
|
|
|
|
EN 62623:2013 — Desktop and notebook computers — |
|||
|
Measurement of energy consumption |
|
||
Measurement methodology for sleep |
5.2. Test setup; |
|
|
|
5.3.3. Measuring sleep mode; |
|
|||
mode |
|
|||
5.4. Test conditions; |
|
|
||
|
|
|
||
|
5.7. True RMS watt meter specification; |
|
||
|
5.8. True RMS watt meter accuracy. |
|
||
|
|
|||
|
EN 62623:2013 — Desktop and notebook computers — |
|||
|
Measurement of energy consumption |
|
||
|
5.2. Test setup; |
|
|
|
Measurement methodology for off mode |
5.3.2. Measuring off mode; |
|
||
|
5.4. Test conditions; |
|
|
|
|
5.7. True RMS watt meter specification; |
|
||
|
5.8. True RMS watt meter accuracy. |
|
||
|
|
|||
Measurement methodology for IPS |
Generalized Test Protocol for Calculating the Energy Efficiency |
|||
of Internal Ac-Dc and Dc-Dc Power Supplies Revision 6.6 |
||||
efficiency |
||||
(April,2012). |
|
|
||
|
|
|
||
|
|
|
|
|
Measurement methodology for EPS |
Not applicable |
|
|
|
efficiency |
|
|
||
|
|
|
||
|
|
|
|