ABB Tmax XT2 Dimensional Sheet

2.87
Approximate dimensions Tmax XT2 - Installation for fixed circuit breaker
Fixed circuit breaker mounting on the backplate
120 (4P)
Captions
1 Insulating plate compulsory
2 Optional wiring ducts
3 25mm insulating barriers
between phases (compulsory) provided
4 Front carter compulsory for through door of the panel ≤ 25mm/0,98"
5
130
5.12
65
0.04
1
0.04
2.56
1
4.72
114
4.49
30
1.18301.18301.18
45
1.77
0.04
4
1
1.1Nm
82.5
3.25
95.5
3.76
90.5
3.56
24
16
0.63
0.94
41
1.61
73
2.87
A
With standard flange III - IV 86
Without flange
III - IV 83.5
III - IV 91.5
Captions
1 Mounting bracket
2 Insulating plate compulsory
3 25mm insulating
barriers between phases (compulsory) provided
45
1.77
84
3.31
3.54
1
0,04
1
3
0.12
Fixed circuit breaker mounting on DIN EN 50022 rail
120
4.72
114
4.49
45
30
1.18301.18
45
1.77
1.77
65
2.56
130
5.12
30
1.18
65
2.56
130
5.12
90
3.54
84
3.31
30
1.18301.18
45
1.77
1.77
45
1
Drilling templates
15
0.59
15
0.59
45
1.77
15
0.59
2
116
4.56
1.5
0.06
3.5
0.14
35
1.38
1.1Nm
1
0.04
7.5
0.29
0.08
95.5
3.76
90.5
3.56
82.5
3.25
16
116
4.56
2
0.63
41
1SDC21034HF0001
24
0.94
1.61
73
1SDC21035HF0001
5/24 SACE Tmax XT UL/CSA | US Technical Catalog
55.5
2.19
Ø 4.5 - M4
Ø 0.18
3 POLES
111
4.37
55.5
2.19
Ø 4.5 - M4
Ø 0.18
4 POLES
111
4.37
1SDC21036HF0001
Flanges
Captions
1 Flange for fixed circuit breaker
III
2 Flange for fixed circuit breaker
IV
3 Flange for fixed circuit breaker
III-IV with MOE and FLD
4 Flange for circuit breaker III-IV
with direct rotary handle RHD
5 Optional flange
100
3.94
104.5
4.11
109.8
4.32
130
5.12
85
3.35
109.8
111
4.32
5
4.37
61
2.40
78
3.07
1SDC21037HF0001
US Technical Catalog | SACE Tmax XT UL/CSA 5/25
Approximate dimensions Tmax XT2 - Installation for fixed circuit breaker
Drilling templates for compartment door
With standard flange
94
3.70
1.85
47
124
4.88
47
1.85
5
Caption
1 Optional flange
29
1.14
83
3.27
3 POLES
Without flange
25
0.98
75
2.95
3 POLES
With optional flange
73
2.87
29
1.14
83
3.27
1SDC21038HF0001
1SDC21039HF0001
1SDC21040HF0001
86
3.36
43
1.69
4 POLES
116
4.56
25
0.98
75
2.95
43
1.69
17
0.67
43
1.69
47
1.85
23.5
0.93
3-4 POLES
4 POLES
57
2.24
28.5
1.12
32
1.26
120 (4P)
4.72
114
4.49
90 (4P)
3.54
3.31
1.77
84
45
1.77
45
22.5
0.89
Execution A B C
With optional flange
fixed 92 3-4 poles
plug-in, mounting at 50mm 142 3-4 poles
plug-in, mounting at 70mm 162 3-4 poles
5/26 SACE Tmax XT UL/CSA | US Technical Catalog
3-4 POLES
1SDC21041HF0001
153
6.02
134
5.27
30
1.18301.18301.18
1SDC21041HF0001
111
Approximate dimensions
Tmax XT2 - Terminals for fixed circuit breaker
Terminals F
Captions
1 25mm insulating barriers
between phases (compulsory) not provided
2 Front terminals for busbar connection
Captions
3 Front extended terminals
4 Terminal covers with degree of
protection IP40 (optional) not provided
20 MAX
0.79
12
0.47
25
0.98
65
2.56
Terminals EF
1.18
~ 100
~ 3.94
30
Ø 6
Ø 0.24
30
1.18301.18
0.27
7 MAX
17.5
0.69
Ø 8.2
Ø 0.32
6Nm
~ 100
58
~ 3.94
2.28
18
0.71
5 MAX
0.20
30
1.18301.18
17.5
0.69
Ø 8.2
Ø 0.32
1SDC21051HF0001
25.5
1
0.20
5
5
6Nm
5 100mm insulating barriers
between phases (compulsory) provided
130
5.12
130
5.12
180
7.09
6 Insulated plate (compulsory)
provided for XT2 Ue>440V
7 Drilling template for 3p circuit
breaker Ue>440V (compulsory)
50
8 Drilling template for 4p circuit
1.97
breaker Ue>440V (compulsory)
120
4.72
Ø 4.5
Ø 0.18
4.37
0.59
15
0.59
15
50
1.97
1
0.04
150
5.90
Ø 4.5
3 POLES 4 POLES
119
4.68
119
4.68
Ø 0.18
111
4.37
3.54
90
45
1.77
0.59
15
119
4.68
119
4.68
Ø 2.65
Ø 0.10
Ø 2.65
Ø 0.10
US Technical Catalog | SACE Tmax XT UL/CSA 5/27
1SDC21043HF0001
Ø 0.10
5.55
5.55
Approximate dimensions
Tmax XT2 - Terminals for fixed circuit breaker
Terminals ES
Captions
1 Drilling template for 3p
circuit breaker Ue>440V (compulsory)
2 Drilling template for 4p
circuit breaker Ue>440V (compulsory)
3 Front extended spread
terminals
4 200mm insulating
barriers between phases (compulsory) provided for
5
Ue>440V
5 Insulated plate (compulsory)
provided for XT2 Ue>440V
1.18
~ 200
~ 7.87
3 POLES
Ø 4.5
Ø 0.18
111
4.37
165
6.50
45
1.77451.77451.77
30
30
1.18301.18301.18
0.59
135
5.31
52.5
Ø 4.5
Ø 0.18
141
5.55
1.18
2.07
30
7.5
0.29
Ø 10.5
Ø 0.41
~ 200
~ 7.87
123
4.84
108
4.25
165
6.50
15
0.59
15
1.18
52.5
2.07
30
112.5
4.43
1.18
30
1.77
25.5
1
1
0.04
Ø 10.5
Ø 0.41
123
4.84
108
4.25
195
7.68
45
0.59
15
5
0.20
4 POLES
55.5
2.19
6Nm
141
111
4.37
Ø 2.65
Ø 0.10
141
Ø 2.65
5.55
141
1SDC21044HF0001
5/28 SACE Tmax XT UL/CSA | US Technical Catalog
25
0.98
14 x 14
0.55 x 0.55
7Nm
61.25 in. lbs
85
3.35
30
1.18301.18301.18
65
2.56
116
4.13
Terminals FCCu
Captions
3 25mm insulating barriers
between phases (compulsory) provided as standard with the circuit breaker
6 Terminals FCCu
Caption
6 Multi-cable terminals
Captions
~ 25
~ 0.98
65
2.56
Terminals MC
115
4.53
Terminals R
30
1.18
30
1.18
30
1.18
14 x 14
25
0.98
58
2.29
0.55 x 0.55
7Nm
61.95 in. lbs
1SDC21048HF0001
5
72
6Nm
2.83
32
29
1.26
1.14
20
0.79
10
10
0.39
Ø 8.2
Ø 0.32
3.5
0.39
0.13
15
0.59
27.5
1.08
1.57
40
7Nm
10
0.39
1SDC21049HF0001
1 Rear adjustable terminals
2 Bottom terminal covers with
degree of protection IP30 (optional) provided
3 Drilling template for mounting
circuit breaker III sheet
4 Drilling template for mounting
circuit breaker IV sheet
30
1.18301.18301.18
18.8
0.74
25
0.98
42.5
8.3
0.32
1.67
67
2.63
116
55.5
21
0.82
2.18
111
4.56
4.36
116
4.56
58
2.28
30
1.18301.18301.18
45
1.77
4 POLES
15
0.59
4.5
0.17
21
0.82
55.5
1SDC21006CF0001
2.18
111
4.36
1SDC21007CF0001
134
5.27
58
2.28
105
92.5
3.64
55
2.16
1SDC21002CF0001
4.56
3 POLES
30
1.18301.18
15
15
0.59
0.59
4.5
0.17
US Technical Catalog | SACE Tmax XT UL/CSA 5/29
Approximate dimensions
Tmax XT2 - Accessories for fixed circuit breaker
Rotary handle operating mechanism on circuit breaker (RHD)
120 (4P)
4.72
90 (3P)
3.54
2
0.08
5
Captions
2 Rotary handle operating mechanism on circuit breaker
45
1.77
16.5
0.65
48.8
1.1Nm
1.92
130
3
0.12
5.12
82.5
3.25
126.3
4.97
120
4.72
171.8
6.76
45.5
1.79
2
0.08
61.5
2.42
(16.5)
(0.65)
Ø 3.5
81
3.19
40.5
1.59
14.5
0.57
200
7.87
MINIMUM ROTATION RADIUS FOR DOOR FULCRUM
Ø 0.14
14
0.55
Ø 3.25
Ø 0.13
54.8
2.15
88
3.46
1SDC21050HF0001
4 Drilling template of door with
direct rotary handle
6 25mm insulating barriers
between phases provided with circuit breaker
5/30 SACE Tmax XT UL/CSA | US Technical Catalog
Rotary handle operating mechanism on the compartment door (RHE)
22.5
0.89
120 (4P)
0.08
Ø 5
Ø 0.20
4.72
2
90 (3P)
3.54
23.5
0.93
45
1.77
2
0.08
16.5
0.65
48.8
16.5
Ø 5
Ø 0.20
1.1Nm
1.92
1.1Nm
0.65
3
0.12
130
HEIGHTS FOR DOOR WITH MAXIMUM DISTANCE
82.5
3.25
5.12
174.2
6.36
(16.5)
(0.65)
597.95
23.54
47.95
1.89
1.4Nm
1.4Nm
2
0.08
46
1.81
Ø 54
Ø 2.13
5
461
18.15
HEIGHTS FOR DOOR WITH MINIMUM DISTANCE
3
0.12
45
1.77
82.5
3.25
156.75
6.17
(16.5)
(0.65)
187.95
7.40
47.95
1.89
2
0.08
1.4Nm
1.4Nm
46
1.81
Ø 54
Ø 2.13
1SDC21052HF0001
200
7.87
MINIMUM ROTATION RADIUS FOR DOOR FULCRUM
Captions
1 Extended rotary handle
operating mechanism
3 Door drilling template with
extended rotary handle
5 Transmission unit
6 25mm insulating barriers
between phases provided with circuit breaker
23.5
0.93
51
2
US Technical Catalog | SACE Tmax XT UL/CSA 5/31
120 (4P)
4.72
90 (3P)
3.54
30
1.18301.18301.18
45
1.77
1.8
0.07
14.8
0.58
38.8
1.53
14.2
0.56
130
5.12
33.5
1.32
12
0.47
28
1.10
82.5
3.25
178.3
7.02
59.5
2.34
37.5
1.48
61.5
2.42
48
1.89
77.3
3.04
26.5
1.04
172
6.77
1.1Nm
2
0.08
3
0.12
Approximate dimensions
Tmax XT2 - Accessories for fixed circuit breaker
Stored energy motor operator (MOE)
120 (4P)
4.72
90 (3P)
30
1.18301.18301.18
130
5.12
5
3.54
45
1.77
12
0.47
33.5
28
1.32
1.10
1.1Nm
82.5
3.25
178.3
7.02
37.5
1.48
26.5
1.04
59.5
2.34
61.5
2.42
48
1.89
77.3
3.04
14.2
0.56
Captions
1 Stored energy motor operator
(MOE)
2 Key lock (not provided)
3 Drilling template of door with
MOE with flange
4 Door drilling template with MOE
without flange
5 Drilling template for mounting
3p circuit breaker on the backplate
1.8
0.07
38.8
1.53
14.8
0.58
3
0.12
91
3.58
45.5
1.79
172
6.77
48.7
1.91
79
3.11
3 POLES
15
0.59
15
0.59
Ø 4.5 - M4
Ø 0.18
55.5
2.19
111
4.37
2
0.08
4 POLES
45
1.77150.59
101
3.97
50.5
1.99
Ø 4.5 - M4
Ø 0.18
55.5
2.19
54.7
111
2.15
4.37
91
3.58
6 Drilling template for mounting
4p circuit breaker on the backplate
7 25mm insulating barriers
between phases provided with circuit breaker
5/32 SACE Tmax XT UL/CSA | US Technical Catalog
1SDC21053HF0001
120 (4P)
4.72
90 (3P)
3.54
30
1.18301.18301.18
45
1.77
36.5
1.44
27.5
1.08
130
5.12
78.4
3.09
29.6
1.16
7
0.27
Ø 3.5
Ø 0.14
2
0.08
3
0.12
120
4.72
82.5
3.25
7.4
0.28
32.9
1.29
22.8
0.90
2.25
0.09
126
4.96
Front for lever operating mechanism (FLD)
120 (4P)
4.72
30
1.18301.18301.18
90 (3P)
3.54
45
1.77
14.5
0.57
91
3.58
7
0.27
78.4
3.09
29.6
1.16
45.5
1.79
14
0.55
130
5.12
27.5
1.08
36.5
1.44
Ø 3.5
Ø 0.14
3
0.12
82.5
3.25
126
4.96
120
4.72
7.4
0.28
2.25
0.09
14.5
0.57
32.9
1.29
2
0.08
14
0.55
22.8
0.90
Ø 3.5
Ø 0.14
Ø 3.5
Ø 0.14
5
Captions
1 Key lock optional
2 Front for lever operating mechanism (FLD)
3 Drilling template of door with
FLD with flange
4 Drilling template of door with
FLD without flange
5 25mm insulating barriers
between phases provided with circuit breaker
61.5
1.93
79
3.11
2.42
200
7.87
49
200
7.87
55
61.5
2.42
2.17
91
3.58
1SDC21054HF0001
US Technical Catalog | SACE Tmax XT UL/CSA 5/33
Approximate dimensions
Tmax XT2 - Accessories for fixed circuit breaker
Ekip Display or Ekip LED Meter
Captions
1 25mm insulating barriers
between phases provided with circuit breaker
2 Ekip Display or Ekip LED Meter
5
130
5.12
82.5
3.25
99.35
3.91
95.5
3.76
90.5
3.56
24
0.63
0.94
41
1.61
73
2.87
1SDC21055HF0001
16
120 (4P)
4.72
114
4.49
30
1.18
1.18
2.56
0.04
1
65
30
45
1.77
84
3.31
90 (3P)
3.54
30
1.18
45
1.77
29.5
19.3
1.16
1.1Nm
0.76
5/34 SACE Tmax XT UL/CSA | US Technical Catalog
Loading...
+ 23 hidden pages