3B SCIENTIFIC® PHYSICS
Optical Lamp K U8475400
Instruction sheet
08/07 SP/ALF
1 Protective cap
2 Alignment guide, horizontal
3 Alignment guide, vertical
1. Safety instructions
• Do not operate the lamp with a voltage higher
than 12 V.
• Do not subject the light source to mechanical
shocks or vibrations.
Caution! Lamps become hot when operated for long
periods! There is a risk of burning!
• Do not touch a hot lamp.
• After a long period of operation, allow the lamp
to cool for at least 20 minutes.
The light becomes very intense.
• Do not look directly into the lamp.
The grease from your hands will smudge the lamp
and considerably reduce its operating life.
• Do not touch halogen lamp bulbs with your
fingers, for example when changing a bulb. Instead use a cloth or a similar form of protection.
4 4-mm safety sockets
5 Knurled securing screw
6 Light aperture and halogen lamp
2. Description
The optical lamp K is used for experiments with the
optical bench K (Kröncke optical system) in combination with the optical rider K.
The halogen lamp is mounted in a cylindrical housing on a reflector (100x100 mm
with the coil either horizontal or vertical.
2.1 Accessories
Halogen lamp 12 V, 20 W U8475410
3. Technical data
Halogen lamp: 12 V, 20 W
Connectors: 4 mm safety sockets
Overall dimensions: 60x100x100 mm approx.
Mass: 130 g approx.
2
). It can be positioned
1
4. Operation
Recommended additional equipment:
For supplying the voltage for the halogen lamp:
Transformer 12 V, 25 VA (230 V, 50/60 Hz)
U8475430-230
or
Transformer 12 V, 25 VA (115 V, 50/60 Hz)
U8475430-115
For mounting the halogen light source:
Optical rider K U8475350
For carrying out the experiments:
Optical bench K, 450 mm U8475336
or
Optical bench K, 1000 mm U8475337
Optical components from the Kröncke optical system
• Set up the experiment.
• Mount the halogen light source on the optical
rider K in the vertical or horizontal position according to preference, and connect it to the
transformer.
• Carry out the experiment.
5. Changing the bulb
• Disconnect the voltage supply from the halogen
light source.
• If necessary, allow the halogen light source to
cool.
• Loosen the knurled securing screws and remove
the protective cap.
• Using a cloth or similar material, take out the
halogen bulb replace it with the new one.
• Refit the protective cap and tighten the screws.
• When disposing of a used halogen lamp, comply
with local regulations.