
EN
MultiScanner® 340
Multifunction Wall Scanner
The MultiScanner® 340 features three scan modes to detect studs and metal up to 1½ in. (38 mm) deep behind
walls, floors, and ceilings. The SpotLite
stud or near metal/AC.
®
Pointing System
SpotLite
AC WireWarning
Indicator
STUD SCAN Mode LED
DEEPSCAN® Mode LED
METAL SCAN Mode LED
Power Button
Note: This product is intended
only for use with an optimum
voltage range of 110 - 127 V.
DeepScan, MultiScanner, SpotLite, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.
Visit www.zircon.com/support for the most current instructions.
LIMITED 1 YEAR WARRANTY
Zircon Corporation, (“Zircon”) warrants this product to be free from defects
in materials and workmanship for one year from the date of purchase. Any
in-warranty defective product returned to Zircon*, freight prepaid with proof
of purchase date and $5.00 to cover postage and handling, will be repaired or
replaced at Zircon’s option. This warranty is limited to the electronic circuitry
and original case of the product and specifically excludes damage caused
by abuse, unreasonable use or neglect. This warranty is in lieu of all other
warranties, express or implied, and no other representations or claims of
any nature shall bind or obligate Zircon. Any implied warranties applicable
to this product are limited to the one year period following its purchase.
IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR
MALFUNCTION OF THIS PRODUCT.
In accordance with government regulations, you are advised that: (i) some
states do not allow limitations on how long an implied warranty lasts and/
or the exclusion or limitation of incidental or consequential damages, so the
above limitations and/or exclusions may not apply to you, and further (ii) this
warranty gives you specific legal rights and you may also have other rights
which vary from state to state.
®
Pointing System automatically displays a beam of light over the edge of a
Stud Edge Groove
Metal Sensor
®
LED Sensing
Display
READY Indicator
Mode Selector Switch
Battery (back of unit)
Return product freight prepaid with proof of purchase date (dated sales receipt)
and $5.00 to cover postage and handling, to:
Zircon Corporation
*Attn: Returns Department
1580 Dell Avenue
Campbell, CA 95008-6992 USA
Be sure to include your name and return address. Out of warranty service and
repair, where proof of purchase is not provided, shall be returned with repairs
charged C.O.D. Allow 4 to 6 weeks for delivery.
Customer Service, 1-800-245-9265 or 1-408-963-4550
Monday–Friday, 8:00 a.m. to 5:00 p.m. PST
www.zircon.com
info@zircon.com
© 2015 Zircon Corporation • P/N 67391 • Rev A 10/15
ZirconCorporation ZirconTV
ZirconTools
|
ZirconToolPro
ZirconTools
1. MODE SELECTION
• When looking for studs, always start in STUD SCAN mode, which scans
through surfaces up to
• DEEPSCAN
®
built-up and thicker than normal construction. You should always
scan the area in STUD SCAN mode first, to verify that DEEPSCAN
is needed. DEEPSCAN
1½ inches (38 mm).
• When scanning for metal pipes or rebar, select METAL SCAN mode.
3
⁄4 inch (19 mm) thick.
mode should only be selected if you know the surface is
®
®
mode is for depths between 3⁄4 inch (19 mm) and
mode
2. OPERATING TIPS
• Tool Position. For proper use, always place tool flat against the surface
before turning on power.
• Power. Press and hold in the Power Button continuously while in use.
• Calibration. Place tool flat against surface. Press and hold the Power
Button. Do not move tool until calibration is complete (1-2 seconds).
When calibration is complete, the READY indicator will light.
• Operation. Move tool slowly, while keeping it flat against the wall.
Do not rock, tilt, or lift it.
• If you calibrate over a stud in DEEPSCAN
detect any studs. Move tool a few inches right or left, release the Power
Button, and start over.
3. SCANNING IN STUD SCAN
OR DEEPSCAN
After calibrating (see number 2), continue to hold the Power Button and
slowly slide the tool across the surface. When full arrow lights, SpotLite
Pointing System shines, and a steady tone sounds, you have located the edge
of the stud. Mark this spot (see illustrations below).
Continue holding Power Button in and scan beyond the marked spot until
arrow bars ramp down.
Without releasing Power Button, slide tool in reverse direction to locate other
edge of stud. Mark this second spot. Middle of stud is centered between the
two marks.
®
MODE
Scanning in STUD SCAN or DEEPSCAN® Mode
®
mode, you probably will not
®
4. SCANNING IN METAL MODE
Select METAL SCAN mode. After calibrating (see number 2), continue to hold
Power Button and slowly slide tool across the surface. When the display
LEDs peak, SpotLite
Continue in the same direction until display LEDs turn off.
Reverse direction and mark the spot where the display LEDs peak from
that direction. The midpoint of the two marks is the approximate center of
the object.
®
beam shines and a steady tone sounds, mark this spot.
Metal
In METAL SCAN mode, if you calibrate directly over metal, you probably
will not detect any metal. Move tool a few inches right or left, release the
Power Button, and start over.
WireWarning® Detection
WireWarning
METAL SCAN modes. When AC voltage is detected, the AC WireWarning
indicator will light.
the scanned surface, in concrete, encased in conduit, present behind
a plywood shear wall or metallic wall covering, or if moisture is
present in the environment or scanned surface.
COULD BE DANGEROUS IF THE WALL CONTAINS A LIVE ELECTRICAL
WIRE. ALWAYS TURN OFF THE ELECTRICAL POWER, GAS, AND WATER
SUPPLIES BEFORE PENETRATING A SURFACE. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS
INJURY OR PROPERTY DAMAGE.
®
detection works continuously in STUD SCAN, DEEPSCAN®, and
WARNING
WARNING
Electrical field locators may not detect live AC
wires if wires are more than 2 in. (51 mm) from
DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL
WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT
®
Always turn off power when working near electrical wires.
5. OPERATING CAUTIONS
Depending on the proximity of electrical wiring or pipes to the wall
surface, tool may detect them in the same manner as studs, especially in
®
mode. Caution should always be used when nailing, sawing,
DEEPSCAN
or drilling into walls, floors, and ceilings that may contain these items.
Because of its increased sensitivity, DEEPSCAN
objects in walls that are not studs.
®
mode may also detect other
To avoid surprises, remember that studs or joists are normally spaced
16 or 24 in. (406 or 610 mm) apart and are 1½ in. (38 mm) in width.
Anything closer together or a different width may not be a stud, joist, or
firebreak. Always turn off the power when working near electrical wires.
Working With Different Materials
• Wallpaper: The MultiScanner
with wallpaper or fabric, unless the materials are metallic foil, contain
metallic fibers, or are still wet after application.
• Lath & plaster: Due to irregularities in plaster thickness, it is difficult for
the tool to locate studs in STUD SCAN mode. Change to METAL SCAN
mode to locate nail heads holding laths to studs. If plaster has metal
mesh reinforcement, tool will be unable to detect anything through
that material.
• Textured walls or acoustic ceilings: When scanning a ceiling or wall
with an uneven surface, place thin cardboard on ceiling or wall and
scan over the cardboard using DEEPSCAN
cardboard in place.
• Wood flooring, subflooring, or gypsum drywall over plywood
sheathing: Use DEEPSCAN
• Tool cannot scan for wood studs and joists through ceramic floor tile,
concrete, or carpeting and pad.
• In problem situations, try using METAL SCAN to locate nails or drywall
screws that line up vertically where a stud is positioned.
Note: Sensing depth and accuracy can vary due to moisture, content of
materials, wall texture, and paint. Indoor use only.
WARNING
information sources to help locate items before penetrating the
surface. Such additional sources include construction plans, visible
points of entry of pipes and wiring into walls, such as in a basement,
and in standard 16 and 24 in. (41 and 61 cm) stud spacing practices.
®
340 functions normally on walls covered
®
mode. Calibrate with
®
mode.
Do not rely exclusively on the detector to locate
items behind the scanned surface. Use other
6. CHANGING THE BATTERY
Press battery door release down with your finger
or a coin and remove door.
Connect brand new 9V alkaline battery to cable
and place inside.
Replace battery door and snap shut.
FCC Part 15 Class B Registration Warning
This device complies with Part 15 of FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
7. HELPFUL HINTS (See also number 2, OPERATING TIPS)
Situation
Not certain the
object found is a
stud in DEEPSCAN
mode.
Lights flashing, tool
beeping (over-thestud indication).
Working in
®
mode
DEEPSCAN
and can’t detect
studs.
Detects other objects
besides studs in
STUD SCAN and
®
modes.
DEEPSCAN
Top LED
doesn’t light.
Difficulty detecting
metal.
Image of metal
object appears wider
than actual size.
Constant readings of
studs near windows
and doors.
You suspect
electrical wires, but
do not detect any.
Probable Causes
®
• DEEPSCAN
®
• Tool was calibrated over a stud or
• Tool tilted or lifted during scan.
• You may have calibrated over a stud.
• Electrical wiring and metal/plastic
• Wall is particularly thick or dense.
• Tool not properly calibrated.
• Metal targets too deep.
• Metal has greater density than
• Double and triple studs are usually
• Wires may be shielded in metal
• Wires deeper than 2 in. (51 mm) from
• Wires may not be hot.
increased sensitivity
may have located something other
than a stud.
on dense part of wall.
®
mode is very sensitive.
(DEEPSCAN
The error condition has been
disabled in this mode.)
pipes may be near or touching back
surface of wall.
wood.
found around doors and windows.
Solid headers are above them.
conduit or behind metallic wall
covering.
surface might not be detected.
• Scan the same area with METAL SCAN and AC Scan. If tool indicates
the presence of metal or hot AC, do NOT assume the original stud
indication is a stud.
• Turn tool off, move over a few inches, press Power Button, and
start again.
• On rough surfaces, place thin cardboard on wall, scanning through
it to help slide scanner more smoothly.
• Move tool over a couple of inches and recalibrate.
• Switch to METAL SCAN mode, where combined with WireWarning
detection, pipes and electrical wiring should be detected.
• Check for other studs equally spaced to either side (12, 16, or 24 in.
apart [305, 406, or 610 mm]) or the same stud at several places
directly above or below the first.
• Use CAUTION when nailing, sawing, or drilling into walls, floors,
and ceilings where these items may exist.
• Interpret the pair of LED bars closest to the center as stud edge.
• Switch to DEEPSCAN
the stud.
• Always calibrate in air for best sensitivity and to avoid calibrating
over any metal.
• Scan in both horizontal and vertical directions. Metal sensitivity is
increased when metal object is parallel to sensor, located at front
end of tool beneath crosshair.
• To reduce sensitivity, recalibrate tool over either of first
two marks.
• Detect outer edges so you know where to begin.
• Try METAL SCAN to see if you can find metal, wire, or metal conduit.
• Always turn off the power when working near electrical wires.
• Try turning on switches to outlet.
• Try plugging a lamp into outlet and turning on switch.
Solutions
®
, where more bars may appear, to locate
®
EN
MultiScanner® 340
Multifunction Wall Scanner
®
The MultiScanner
walls, floors, and ceilings. The SpotLite
stud or near metal/AC.
DeepScan, MultiScanner, SpotLite, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.
Visit www.zircon.com/support for the most current instructions.
LIMITED 1 YEAR WARRANTY
Zircon Corporation, (“Zircon”) warrants this product to be free from defects
in materials and workmanship for one year from the date of purchase. Any
in-warranty defective product returned to Zircon*, freight prepaid with proof
of purchase date and $5.00 to cover postage and handling, will be repaired or
replaced at Zircon’s option. This warranty is limited to the electronic circuitry
and original case of the product and specifically excludes damage caused
by abuse, unreasonable use or neglect. This warranty is in lieu of all other
warranties, express or implied, and no other representations or claims of
any nature shall bind or obligate Zircon. Any implied warranties applicable
to this product are limited to the one year period following its purchase.
IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR
MALFUNCTION OF THIS PRODUCT.
In accordance with government regulations, you are advised that: (i) some
states do not allow limitations on how long an implied warranty lasts and/
or the exclusion or limitation of incidental or consequential damages, so the
above limitations and/or exclusions may not apply to you, and further (ii) this
warranty gives you specific legal rights and you may also have other rights
which vary from state to state.
340 features three scan modes to detect studs and metal up to 1½ in. (38 mm) deep behind
®
SpotLite
Pointing System
AC WireWarning
Indicator
®
Pointing System automatically displays a beam of light over the edge of a
®
STUD SCAN Mode LED
®
DEEPSCAN
Mode LED
READY Indicator
METAL SCAN Mode LED
Power Button
Note: This product is intended
only for use with an optimum
voltage range of 110 - 127 V.
Return product freight prepaid with proof of purchase date (dated sales receipt)
and $5.00 to cover postage and handling, to:
Zircon Corporation
*Attn: Returns Department
1580 Dell Avenue
Campbell, CA 95008-6992 USA
Be sure to include your name and return address. Out of warranty service and
repair, where proof of purchase is not provided, shall be returned with repairs
charged C.O.D. Allow 4 to 6 weeks for delivery.
Customer Service, 1-800-245-9265 or 1-408-963-4550
Monday–Friday, 8:00 a.m. to 5:00 p.m. PST
www.zircon.com
info@zircon.com
ZirconCorporation ZirconTV
ZirconTools
© 2015 Zircon Corporation • P/N 67391 • Rev A 10/15
Mode Selector Switch
Battery (back of unit)
|
ZirconToolPro
Stud Edge Groove
Metal Sensor
LED Sensing
Display
ZirconTools
1. MODE SELECTION
• When looking for studs, always start in STUD SCAN mode, which scans
through surfaces up to
• DEEPSCAN
®
built-up and thicker than normal construction. You should always
scan the area in STUD SCAN mode first, to verify that DEEPSCAN
is needed. DEEPSCAN
1½ inches (38 mm).
• When scanning for metal pipes or rebar, select METAL SCAN mode.
3
⁄4 inch (19 mm) thick.
mode should only be selected if you know the surface is
®
®
mode is for depths between 3⁄4 inch (19 mm) and
mode
4. SCANNING IN METAL MODE
Select METAL SCAN mode. After calibrating (see number 2), continue to hold
Power Button and slowly slide tool across the surface. When the display
LEDs peak, SpotLite
Continue in the same direction until display LEDs turn off.
Reverse direction and mark the spot where the display LEDs peak from
that direction. The midpoint of the two marks is the approximate center of
the object.
®
beam shines and a steady tone sounds, mark this spot.
Metal
2. OPERATING TIPS
• Tool Position. For proper use, always place tool flat against the surface
before turning on power.
• Power. Press and hold in the Power Button continuously while in use.
• Calibration. Place tool flat against surface. Press and hold the Power
Button. Do not move tool until calibration is complete (1-2 seconds).
When calibration is complete, the READY indicator will light.
• Operation. Move tool slowly, while keeping it flat against the wall.
Do not rock, tilt, or lift it.
• If you calibrate over a stud in DEEPSCAN
detect any studs. Move tool a few inches right or left, release the Power
Button, and start over.
3. SCANNING IN STUD SCAN
OR DEEPSCAN
After calibrating (see number 2), continue to hold the Power Button and
slowly slide the tool across the surface. When full arrow lights, SpotLite
Pointing System shines, and a steady tone sounds, you have located the edge
of the stud. Mark this spot (see illustrations below).
Continue holding Power Button in and scan beyond the marked spot until
arrow bars ramp down.
Without releasing Power Button, slide tool in reverse direction to locate other
edge of stud. Mark this second spot. Middle of stud is centered between the
two marks.
®
MODE
®
mode, you probably will not
Scanning in STUD SCAN or DEEPSCAN® Mode
In METAL SCAN mode, if you calibrate directly over metal, you probably
will not detect any metal. Move tool a few inches right or left, release the
Power Button, and start over.
WireWarning
WireWarning
METAL SCAN modes. When AC voltage is detected, the AC WireWarning
indicator will light.
the scanned surface, in concrete, encased in conduit, present behind
®
a plywood shear wall or metallic wall covering, or if moisture is
present in the environment or scanned surface.
COULD BE DANGEROUS IF THE WALL CONTAINS A LIVE ELECTRICAL
WIRE. ALWAYS TURN OFF THE ELECTRICAL POWER, GAS, AND WATER
SUPPLIES BEFORE PENETRATING A SURFACE. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS
INJURY OR PROPERTY DAMAGE.
®
Detection
®
detection works continuously in STUD SCAN, DEEPSCAN®, and
WARNING
WARNING
Electrical field locators may not detect live AC
wires if wires are more than 2 in. (51 mm) from
DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL
WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT
Always turn off power when working near electrical wires.
5. OPERATING CAUTIONS
Depending on the proximity of electrical wiring or pipes to the wall
surface, tool may detect them in the same manner as studs, especially in
®
mode. Caution should always be used when nailing, sawing,
DEEPSCAN
or drilling into walls, floors, and ceilings that may contain these items.
Because of its increased sensitivity, DEEPSCAN
objects in walls that are not studs.
®
mode may also detect other
To avoid surprises, remember that studs or joists are normally spaced
16 or 24 in. (406 or 610 mm) apart and are 1½ in. (38 mm) in width.
Anything closer together or a different width may not be a stud, joist, or
firebreak. Always turn off the power when working near electrical wires.
Working With Different Materials
• Wallpaper: The MultiScanner
with wallpaper or fabric, unless the materials are metallic foil, contain
metallic fibers, or are still wet after application.
• Lath & plaster: Due to irregularities in plaster thickness, it is difficult for
the tool to locate studs in STUD SCAN mode. Change to METAL SCAN
mode to locate nail heads holding laths to studs. If plaster has metal
mesh reinforcement, tool will be unable to detect anything through
that material.
• Textured walls or acoustic ceilings: When scanning a ceiling or wall
with an uneven surface, place thin cardboard on ceiling or wall and
scan over the cardboard using DEEPSCAN
cardboard in place.
• Wood flooring, subflooring, or gypsum drywall over plywood
sheathing: Use DEEPSCAN
• Tool cannot scan for wood studs and joists through ceramic floor tile,
concrete, or carpeting and pad.
• In problem situations, try using METAL SCAN to locate nails or drywall
screws that line up vertically where a stud is positioned.
Note: Sensing depth and accuracy can vary due to moisture, content of
®
materials, wall texture, and paint. Indoor use only.
WARNING
information sources to help locate items before penetrating the
surface. Such additional sources include construction plans, visible
points of entry of pipes and wiring into walls, such as in a basement,
and in standard 16 and 24 in. (41 and 61 cm) stud spacing practices.
®
340 functions normally on walls covered
®
mode. Calibrate with
®
mode.
Do not rely exclusively on the detector to locate
items behind the scanned surface. Use other
6. CHANGING THE BATTERY
Press battery door release down with your finger
or a coin and remove door.
Connect brand new 9V alkaline battery to cable
and place inside.
Replace battery door and snap shut.
FCC Part 15 Class B Registration Warning
This device complies with Part 15 of FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
7. HELPFUL HINTS (See also number 2, OPERATING TIPS)
Situation
Not certain the
object found is a
stud in DEEPSCAN
mode.
Lights flashing, tool
beeping (over-thestud indication).
Working in
®
mode
DEEPSCAN
and can’t detect
studs.
Detects other objects
besides studs in
STUD SCAN and
®
modes.
DEEPSCAN
Top LED
doesn’t light.
Difficulty detecting
metal.
Image of metal
object appears wider
than actual size.
Constant readings of
studs near windows
and doors.
You suspect
electrical wires, but
do not detect any.
Probable Causes
®
• DEEPSCAN
®
• Tool was calibrated over a stud or
• Tool tilted or lifted during scan.
• You may have calibrated over a stud.
• Electrical wiring and metal/plastic
• Wall is particularly thick or dense.
• Tool not properly calibrated.
• Metal targets too deep.
• Metal has greater density than
• Double and triple studs are usually
• Wires may be shielded in metal
• Wires deeper than 2 in. (51 mm) from
• Wires may not be hot.
increased sensitivity
may have located something other
than a stud.
on dense part of wall.
®
mode is very sensitive.
(DEEPSCAN
The error condition has been
disabled in this mode.)
pipes may be near or touching back
surface of wall.
wood.
found around doors and windows.
Solid headers are above them.
conduit or behind metallic wall
covering.
surface might not be detected.
• Scan the same area with METAL SCAN and AC Scan. If tool indicates
the presence of metal or hot AC, do NOT assume the original stud
indication is a stud.
• Turn tool off, move over a few inches, press Power Button, and
start again.
• On rough surfaces, place thin cardboard on wall, scanning through
it to help slide scanner more smoothly.
• Move tool over a couple of inches and recalibrate.
• Switch to METAL SCAN mode, where combined with WireWarning
detection, pipes and electrical wiring should be detected.
• Check for other studs equally spaced to either side (12, 16, or 24 in.
apart [305, 406, or 610 mm]) or the same stud at several places
directly above or below the first.
• Use CAUTION when nailing, sawing, or drilling into walls, floors,
and ceilings where these items may exist.
• Interpret the pair of LED bars closest to the center as stud edge.
• Switch to DEEPSCAN
the stud.
• Always calibrate in air for best sensitivity and to avoid calibrating
over any metal.
• Scan in both horizontal and vertical directions. Metal sensitivity is
increased when metal object is parallel to sensor, located at front
end of tool beneath crosshair.
• To reduce sensitivity, recalibrate tool over either of first
two marks.
• Detect outer edges so you know where to begin.
• Try METAL SCAN to see if you can find metal, wire, or metal conduit.
• Always turn off the power when working near electrical wires.
• Try turning on switches to outlet.
• Try plugging a lamp into outlet and turning on switch.
Solutions
®
, where more bars may appear, to locate
®