Zibro R 421 E User Manual [de]

R 421 E
3
2
6
5
4
>
u
1
:
=
FIN
MANUEL D'UTILISATION
GEBRAUCHSANWEISUNG
BRUGSANVISNING
KÄYTTÖOHJE
OPERATING MANUAL
ISTRUZIONI D’USO
BRUKSANVISNING
GEBRUIKSAANWIJZING
INSTRUKCJI OBS
ŁUGI
BRUKSANVISNING
2
14
26
38
50
62
74
86
98
110
122
Dear Sir, Madam,
Congratulations on your purchase of this Zibro heater, the number one brand
amongst portable heaters. You have purchased a quality product, which will
serve you for many years to come. This, of course, provided you use the heater
correctly. Please read these Directions for Use first, to ensure the maximum
lifetime for your heater.
This appliance comes with a 24-month manufacturer’s warranty on all defects
in materials or workmanship.
We wish you much warmth and comfort from your Zibro.
Yours sincerely,
PVG International b.v.
Customer Service Department
1 READ THE DIRECTIONS FOR USE FIRST.
2 IN CASE OF ANY DOUBT, CONTACT YOUR ZIBRO DEALER.
3 BEFORE YOU START READING, FOLD OUT THE LAST PAGE. ! ! ! ! ! ! ! ! ! !
4
62
GENERAL DIRECTIONS FOR USE
Below you will find the main steps to be taken for
using your heater. For more details, please refer to
the MANUAL (pages 65 ff.).
The first time you ignite your heater it will smell
like ’new’ for a short time.
Store your fuel in a cool and dark place.
Fuel has a limited shelf life. Start every heating
season with new fuel.
The right quality of fuel will be assur
ed, when you
use Zibro Extra or Zibro Kristal for your heater.
If you change to another brand and/or type of
paraf
fin oil, you must first finish up all the
remaining fuel in the heater.
MAIN COMPONENTS
OFF - button (for
emergency stop)
Knurled wick
adjustment knob
Ignition button
Combustion chamber
Combustion chamber
handle
Fuel indicator
Grill
Lid for removable
tank
Removable tank
Fuel gauge
r
emovable tank
Ignition coil
Battery holder
Air quality contr
ol
system
Information display
(E-Guar
d)
W
ick height lock
!
"
#
$
%
&
'
(
)
*
+
,
-
.
/
! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !
Remove all packaging materials (refer to Section A, Fig. A).
Fill the removable tank ) and wait 30 minutes before you
ignite the heater
(refer to Section B, Fig. H).
Inser
t the batteries into the battery holder
,
(r
efer to Section A, Fig. F).
Check whether the combustion chamber 0 is fully upright
(refer to Section A, Fig. E).
Ignite the heater by turning the Knurled wick adjustment knob
" and the ignition button # simultaneously (refer to Section
C, Fig. J and K).
After igniting the heater it will take 10 to 15 minutes before
you can check if the heater burns well (refer to Section D).
Switch off the heater (refer to Section E).
1
2
3
4
5
6
7
4
63
WHAT YOU NEED TO KNOW IN ADVANCE
ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION
This heater is equipped with an air quality control system !. When there is
insufficient ventilation in the room or when the heater is being used in a room
w
hich is too small, the heater will shut off automatically. For comfortable and safe
heating ensure that there is sufficient ventilation.
Note: To avoid unexpected shut off, we recommend to put a door or window ajar
when the heater is operating.
For each model the minimum size of space is specified in which you can use the
heater safely, without additional ventilation
(refer to Section K). If a particular
room is smaller than the specified space, always leave a window or door slightly
ajar (± 2.5 cm). We also recommend doing this in highly insulated or draught-free
rooms and/or at altitudes above 1,500 metres. Do not use your heater in cellars or
other underground areas.
SAFE TOP
The heater is supplied with a safe top. This application decreases the temperature
of the top plate. In this way, the risk of harmful accidents at accidentally touching
the top plate is considerably decreased. However, be aware that the top plate still
becomes hot.
Avoid any contact with the top plate and grille.
THE RIGHT FUEL
Only use Class C1 paraffin fuel in accordance with BS2869 Part two, or equivalent.
Your Zibro heater has been designed for use with high-quality water-free pure
paraffin oil, such as Zibro Extra or Zibro Kristal. Only fuels of this kind will ensure
clean and proper burning. Lower quality fuel may result in:
! excessive tar deposits on the glass fibre wick
! incomplete burning
! reduced heater lifetime
! smoke and/or smells
! deposits on the grid or mantle
Using the right fuel is therefore essential for safe, efficient, and comfortable use
of your heater.
Always refer to your local Zibro dealer for the right fuel for your heater.
4
64
A
This transpor
tation cap
is packed separately in
the box. Only this cap
ensures trouble-fr
ee
transportation of the
heater after use.
Store it well!
Only the use of the
correct fuel will ensure
safe, efficient, and
comfortable use of your
heater.
MANUAL
A INSTALLING THE HEATER
Carefully remove your Zibro heater from the box and check the contents.
I
n addition to the heater you also need to have:
! a manual fuel pump
! a transportation cap
! these directions for use
Keep the box and the packaging materials (Fig. A) for storage and/or transportation.
Remove the other packaging materials:
! Remove the packaging material from the grill !. Lift the grill from the slot
(Fig. B) and pull it forward.
! Push the packing material on top of the combustion chamber " slightly
down and remove it (Fig. C). Remove the packaging materials from under
the combustion chamber as well (Fig. D).
! Put the combustion chamber back into its place. The combustion chamber
is positioned correctly when it can be smoothly moved a little to the left
and to the right by its handle # (Fig. E). Close the grill: Slightly lift it to
reposition it in its slot.
! Open the lid for removable tank $ and remove the piece of cardboard.
Fill the removable tank as indicated in Section B.
Insert the batteries into their holder % at the back of the heater (Fig. F).
Ensure that the positive and negative poles match the + and - marks indicated
on the battery housing.
The floor should be firm and completely level.
Your heater is now ready for use.
B FILLING FUEL
Do not fill the removable tank in the living room, but in a more suitable place
(there can always be some spillage). Follow the procedure below:
Make sure that the heater is switched off.
Open the lid
$ and lift the removable tank & out of the heater (Fig. G).
Note: Some dr
ops may leak from the tank. Put down the removable tank
(cap pointing upwards) and screw off the fuel cap.
2165432
1
4
65
! ! ! ! ! !
B
C
D
E
G
F
T
ake the manual fuel pump and insert the smooth, most rigid tube into the
jerrycan. Make sure that it is in a higher position than the removable tank
(Fig. H). Insert the ribbed hose into the opening of the removable tank.
Lock the valve on top of the pump (turn clockwise).
Squeeze the pump a few times, until fuel starts flowing into the removable
tank. As soon as this happens, there is no need to press any longer.
Check the removable tank fuel gauge
! while filling the tank (Fig. I). Stop
filling by loosening the valve on top of the pump (turn anti-clock-wise), once
the gauge indicates that the tank is full. Never overfill the tank, especially not
when the fuel is very cold (fuel expands when it heats up).
Let the remaining fuel in the pump flow back into the jerrycan and carefully
remove the pump. Carefully screw the fuel cap back on the tank. Clean off
any spilled fuel.
Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.
C IGNITING THE HEATER
A new heater may give off some smells for a short while, when it is used for the
first time. You should therefore provide extra ventilation or ignite the heater
outside the living room.
When you use the heater for the first time, first put the filled removable tank into
place, and then wait approximately 30 minutes before you ignite the heater. This
allows the glass fibre wick to soak up the fuel. Follow the same procedure when you
have completely burnt up all fuel from the tank, and after the glass fibre wick has
been replaced.
Before igniting the heater, always check the fuel indicator
" to see whether the
removable tank needs filling up.
Always ignite the heater with the ignition coil #. Never use matches or a cigar
ette
lighter
.
Follow the procedure below:
Turn the knurled wick adjustment knob $ clockwise to its stop (Fig. J). If you
apply more pressure you may turn it slightly further; however, it will automatically
return to the startposition. When you have set the wick to its highest position,
this action will automatically activate the safety device.
Push in the ignition button % (Fig. K), but do not apply too much for
ce.
Release the ignition button as soon as a flame is visible in the combustion
chamber
&.
When you have ignited the heater but it shuts off again shortly after, the batteries
need to be r
eplaced. It is best to use new alkaline batteries (4x D-size).
2
1
876
543
4
66
I
H
empty full
J
E
K
If the heater has been used only a few times and the wick adjustment knob is not
locked, first turn the wick adjustment knob (Fig. S) completely left, before putting the
wick in the highest position for ignition (Section C).
After having ignited the heater, always check whether the combustion
chamber ! is level, by sliding it slightly to the left and the right by its handle
(
Fig. E) ".This should be a smooth movement. If the combustion chamber is
not level, this will cause smoke and soot to develop.
D BURNING OF THE HEATER
After you have ignited the heater, it will take 10 to 15 minutes before you can
check whether the heater is burning well. Too high a flame may cause smoke and
soot, whereas too low a flame causes smells. The page opposite the folding page
shows the minimum and maximum permissible burning heights of the flame (Fig. P).
The flame can be slightly adjusted with knurled wick adjustment knob # (Fig. S).
If the flame remains low after the adjustment, the wick height must be
adjusted
(refer to Section F).
Too low a flame may also be caused by:
! insufficient fuel (fill the tank)
! poor fuel quality (contact your dealer)
! insufficient ventilation (leave window or door ajar)
! wastage of the wick (contact your dealer or replace the wick,
refer to section M)
When there is insufficient ventilation in the room, an intermittent buzzer will be
heard and the VENT lamp (Yellow) will be lit (Fig. Q) . When this signal is given,
ensure that the ventilation of the room is improved (e.g. by opening a door or
window a little more) to avoid that the heater shuts off. When the ventilation of
the room is improved, the VENT lamp and buzzer will be deactivated. When there
is still insufficient ventilation, the heater shuts off automatically. After improving
the ventilation of the room (e.g. by opening a door or window a little more), the
heater can be ignited again.
This heater is fitted with a safety system that ensures that it switches off if you
lift the exchange tank out of the heater. To switch the heater on again, put the
exchange tank back and follow the steps in
chapter C.
E SWITCHING OFF THE HEA
TER
Let the heater burn at its lowest setting for approximately one minute. Push the
OFF-button $. The flame will extinguish after a little while (Fig. L).
In cases of emergency: switch off the heater with the OFF - button $ (Fig. L).
4
67
S
L
Q
V
E
N
T
.
F ADJUSTING THE WICK HEIGHT
After a period of time the combustion may no longer be high enough (Section D). In
that case you can adjust the wick height to improve the flame. To do this, the heater
must have been switched off. Follow the procedure below:
P
ush the OFF-button
! (
Fig. L).
Pull the knurled wick adjustment knob " off the heater, so the wick height
lock # will be visible.
Take t he plast ic colla r b etwee n y our thum b and in dex fing er and pull it out.
Turn t he co llar up one s tep, to eithe r positi on 2 or 3 (Fig. R) . Car efu lly p ush
the collar back, so the pin engages in the recess.
Carefully reinstall the knurled wick adjustment knob. This can be done in one
way only - check the rear of the cap for the correct position.
If adjustment of the wick height does not have the required effect, let the
heater burn until all fuel has been used up (Section H).
If the flame height is still too low and the wick is set on position 3, then contact your
dealer,
or replace the wick, refer to section M.
If the flame gets too high after adjus-
ting (Fig P), the wick height lock should be placed one position lower again.
Otherwise smoke or soot may be caused.
G MALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below, please contact your Zibro dealer.
THE HEATER DOES NOT IGNITE
! The batteries are not positioned correctly in the holder. Check (Fig. F). ! There is not enough power left in the batteries for the ignition. Replace (Fig. F). ! You have run out of fuel from the tank or the wick has been repl ac ed .
After having r
efilled and r
eplaced the removable tank, wait for 30 minutes
before igniting the heater.
! Y
ou are pushing the Ignition button
$ with too much for
ce.
Push it down less forcefully (Section C).
! The ignition coil % is defective.
Contact your dealer.
IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS
! The combustion chamber & has not been positioned correctly.
Use the handle ' to put it level, until you can easily slide it slightly to the left and to the right and the chamber is level.
! The flame height has not been adjusted properly.
See Fig. P and the directions in Section D.
! Y
ou are using fuel which is past its ‘use by’ date.
Star
t ever
y heating season with fresh fuel.
! You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (Section ’What you need to know in advance’).
! Dust has gather
ed in the lower par
t of the heater
.
Contact your dealer.
! The wick heigt is not cor
r
ect.
See Section F.
THE HEATER SLOWLY EXTINGUISHES
! The removable tank is empty.
4
3
2
1
4
68
broken ignition coil
R
F
Refer to Section B.
! The lower reservoir is contaminated by water.
Contact your dealer.
! The wick has hardened on the upper side.
Burn the heater until all fuel is used (Section H). Use the right fuel.
! You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
THE HEATER REMAINS BURNING LOW
! Wick position too low.
Reinstall the wick height lock (Section F).
! Before you refilled the tank, the heater had burnt up almost all the fuel.
After having refilled and replaced the removable tank, wait for 30 minutes b
efore igniting the heater.
! You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (Section ’What you need to know in advance’).
! The room is insufficiently ventilated.
Leave a window or a door wide open for a while.
THE HEATER BURNS TOO HIGH, THE FLAMES CANNOT BE ADJUSTED.
! You are using an incorrect, too volatile type of fuel.
Refer to THE RIGHT FUEL (Section ’What you need to know in advance’).
! Wick position too high.
Reinstall the wick height lock (Section F).
H MAINTENANCE
Your heat er need s hard ly any main te na nc e. It is, howe ve r, impo rt an t that you remove dust and stains in time with a damp cloth, because otherwise these may cause stains that are hard to remove. Under normal conditions, only three components are subject to wear:
1. THE BATTERIES
You m ay rep lac e t he bat ter ies yo urs elf . Do n ot dis pos e o f o ld bat ter ies al ong wi th the other domestic waste. Follow the locally applicable regulations regarding the disposal of domestic chemical waste.
2. THE WICK
To ext end the g lass fibr e w ick life , y ou must occasiona lly let the heate r burn until the tank is completely emptied and the heater extinguishes by itself. Do this when you notice that the flame is weakening. The burn-out will cause some smells, so it is recommended that you take the heater outside of the living room.
3. THE IGNITION COIL
The ignition coil will last longer if you ignite in the right way. Replace the batteries on time and make sure you do not push the ignition button too forcefully. If the filament is broken, you should replace the coil.
THE FUEL FILTER
Check the fuel filter regularly as well. Remove the removable tank
! from the heater and take out the fuel filter (Fig.
M). Some drops of fuel may spill from the filter; keep a cloth at hand. Turn the fuel filter upside down and clean it from all dirt deposits by tapping it on a hard sur­face.
(Never clean it with water!) Reposition the fuel filter in the heater.
Do not remove any heater components yourself. Always contact your dealer for repairs.
Let the heater cool down first, before you start any maintenance or service work.
4
69
ignition coil
M
fuel filter
I STORAGE (END OF THE HEATING SEASON)
We recommend that you burn up all the fuel in the fuel tank at the end of the heating
season and store the heater properly. Follow the next procedure:
Ignite the heater outside the living room and let it burn until all fuel is used.
Let the heater cool down.
Clean the heater with a damp cloth and then dry it with a cloth.
Remove the batteries from the holder
! and store them in a dry place.
Clean the fuel filter (refer to section H).
Store the heater in a dust-free place, if possible in its original packaging. Unused fuel cannot be used for the next heating season. If there is still some fuel left, do not throw it away, but dispose of it in accordance with the local regulations for the disposal of domestic chemical waste.
Always start the new heating season with fresh fuel. When you start re-using the heater
, follow the instructions again
(star
ting from Section A and as
specified).
J TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
Let the heater cool down.
Remove the removable tank " from the heater and remove the fuel filter
(Fig. N). Some drops may leak from the filter; keep a cloth at hand. Store the
fuel filter and the removable tank outside the heater.
Place the transportation cap into the position of the fuel filter (Fig. O).
Press it tight.
Always move the heater in an upright position.
K SPECIFICATIONS
Ignition electrical Dimensions (mm) width 428
Fuel paraffin (including base plate) depth 295
Capacity (kW)
*
2.70
height 513
Suitable space (m3)
**
45-95 Accessories: manual fuel pump
Fuel consumption (l/hr)
*
0.281 transportation cap
Fuel consumption (g/hr)
*
225
Required batteries
4x LR20
, MN 1300
Burning time per tank (hr)
*
14.2 1.5V
Capacity removable tank (litres) 4.0 Wick type F
Weight (kg) 9.0
Monitoring of the quality of ventilation (air r
enewal):
Dir
ect measur
ement of the CO
2
level (NDIR CO2-sensor E-Guard#).
*
At maximum setting
**
Specified values are indicative
4321765
4
3
2
1
4
70
O
transportation cap
N
fuel filter
Loading...
+ 22 hidden pages