COPYRIGHT 2000–2006 Zhone Technologies, Inc. All rights reserved.
This publication is protected by copyright law. No part of this publication may be copied,
distributed, displayed, modified, transmitted, stored in a retrieval system, or translated without
express written permission from Zhone Technologies, Inc.
Acculink, ADSL/R, Bitstorm, Comsphere, DSL the Easy Way, ETC, Etherloop, FrameSaver,
GranDSLAM, GrandVIEW, Hotwire, the Hotwire logo, iMarc, Jetstream, MVL, NextEDGE,
Net to Net Technologies, OpenLane, Paradyne, the Paradyne logo, Performance Wizard,
ReachDSL, StormPort, TruePut are registered trademarks of Zhone Technologies, Inc.
BAN, Connect to Success, GigMux, Hotwire Connected, JetFusion, JetVision, MALC,
MicroBurst, PacketSurfer, Quick Channel, Raptor, Reverse Gateway, SLMS, Spectrum
Manager, StormTracker, Z-Edge, Zhone, ZMS, and the Zhone logo are trademarks of Zhone
Technologies, Inc.
All other products names or service marks mentioned herein are the trademarks, trade names
and service names of their respective owners.
Zhone Technologies makes no representation or warranties with respect to the contents hereof
and specifically disclaims any implied warranties of merchantability, noninfringement, or
fitness for a particular purpose. Further, Zhone Technologies reserves the right to revise this
publication and to make changes from time to time in the contents hereof without obligation of
Zhone Technologies to notify any person of such revision or changes.
!
Important Safety Instructions
1 Read and follow all warning notices and instructions marked on the
product or included in the manual.
2 Slots and openings in the cabinet are provided for ventilation. To ensure
reliable operation of the product and to protect it from overheating, these
slots and openings must not be blocked or covered.
3 Do not allow anything to rest on the power cord and do not locate the
product where persons will walk on the power cord.
4 Do not attempt to service this product yourself, as opening or removing
covers may expose you to dangerous high voltage points or other risks.
Refer all servicing to qualified service personnel.
5 General purpose cables are used with this product for connection to the
network. Special cables, which may be required by the regulatory
inspection authority for the installation site, are the responsibility of the
customer. Use a UL Listed, CSA certified, minimum No. 24 AWG line
cord for connection to the Digital Subscriber Line (DSL) network.
6 When installed in the final configuration, the product must comply with
the applicable Safety Standards and regulatory requirements of the
country in which it is installed. If necessary, consult with the appropriate
regulatory agencies and inspection authorities to ensure compliance.
7 A rare phenomenon can create a voltage potential between the earth
grounds of two or more buildings. If products installed in separate
buildings are interconnected, the voltage potential may cause a hazardous
condition. Consult a qualified electrical consultant to determine whether
or not this phenomenon exists and, if necessary, implement corrective
action prior to interconnecting the products.
8 Input power to this product must be provided by one of the following: (1)
a UL Listed/CSA certified power source with a Class 2 or Limited Power
Source (LPS) output for use in North America, or (2) a certified
transformer, with a Safety Extra Low Voltage (SELV) output having a
maximum of 240 VA available, for use in the country of installation.
9 In addition, since the equipment is to be used with telecommunications
circuits, take the following precautions:
— Never install telephone wiring during a lightning storm.
— Never install telephone jacks in wet locations unless the jack is
specifically designed for wet locations.
— Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface.
— Use caution when installing or modifying telephone lines.
— Avoid using a telephone (other than a cordless type) during an
electrical storm. There may be a remote risk of electric shock from
lightning.
— Do not use the telephone to report a gas leak in the vicinity of the
leak.
6212-I3 4-Port Router User’s Guide3
CE Marking
When the product is marked with the CE mark on the equipment label, a
supporting Declaration of Conformity may be downloaded from the Zhone
World Wide Web site at www.zhone.com.
FCC Part 15 Declaration
An FCC Declaration of Conformity may be downloaded from the Zhone
World Wide Web site at www.zhone.com.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The authority to operate this equipment is conditioned by the requirement that
no modifications will be made to the equipment unless the changes or
modifications are expressly approved by the responsible party.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
zReorient or relocate the receiving antenna.
zIncrease the separation between the equipment and receiver.
zConnect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
zConsult the dealer or an experienced radio/TV technician for help.
Notice to Users of the United States Telephone Network
The following notice applies to versions of the modem that have been FCC
Part 68 approved.
This equipment complies with Part 68 of the FCC rules and the requirements
adopted by the Administrative Council for Terminal Attachment (ACTA). On
the bottom side of this equipment is a label that contains, among other
information, a product identifier in the format US:AAAEQ##TXXXX. If
requested, this number must be provided to the Telephone Company.
46212-I3 4-Port Router User’s Guide
This equipment is intended to connect to the Public Switched Telephone
Network through a Universal Service Order Code (USOC) type RJ11C jack.
A plug and jack used to connect this equipment to the premises wiring and
telephone network must comply with the applicable FCC Part 68 rules and
requirements adopted by the ACTA. A compliant telephone cord and modular
plug is provided with this product. It has been designed to be connected to a
compatible modular jack that is also compliant.
The Ringer Equivalence Number (or REN) is used to determine the number of
devices that may be connected to a telephone line. Excessive RENs on a
telephone line may result in the devices not ringing in response to an
incoming call. In most but not all areas, the sum of RENs should not exceed
five (5.0). To be certain of the number of devices that may be connected to a
line, as determined by the total RENs, contact the local Telephone Company.
The REN for this product is part of the product identifier that has the format
US:AAAEQ##TXXXX. The digits represented by ## are the REN without a
decimal point. For example, 03 represents a REN of 0.3.
If the modem causes harm to the telephone network, the Telephone Company
will notify you in advance that temporary discontinuance of service may be
required. But if advance notice is not practical, the Telephone Company will
notify the customer as soon as possible. Also, you will be advised of your
right to file a complaint with the FCC if you believe it is necessary.
The Telephone Company may make changes in its facilities, equipment,
operations or procedures that could affect the operation of the equipment. If
this happens, the Telephone Company will provide advance notice in order for
you to make necessary modifications to maintain uninterrupted service. If
trouble is experienced with the modem, refer to the repair and warranty
information in this document.
If the equipment is causing harm to the telephone network, the Telephone
Company may request that you disconnect the equipment until the problem is
resolved.
The user may make no repairs to the equipment.
Connection to party line service is subject to state tariffs. Contact the state
public utility commission, public service commission or corporation
commission for information.
If the site has specially wired alarm equipment connected to the telephone
line, ensure the installation of the modem does not disable the alarm
equipment. If you have questions about what will disable alarm equipment,
consult your Telephone Company or a qualified installer.
Notice to Users of the Canadian Telephone Network
NOTICE: This equipment meets the applicable Industry Canada Terminal
Equipment Technical Specifications. This is confirmed by the registration
number. The abbreviation IC before the registration number signifies that
registration was performed based on a Declaration of Conformity indicating
that Industry Canada technical specifications were met. It does not imply that
Industry Canada approved the equipment.
6212-I3 4-Port Router User’s Guide5
NOTICE: The Ringer Equivalence Number (REN) for this terminal
equipment is labeled on the equipment. The REN assigned to each terminal
equipment provides an indication of the maximum number of terminals
allowed to be connected to a telephone interface. The termination on an
interface may consist of any combination of devices subject only to the
requirement that the sum of the Ringer Equivalence Numbers of all the
devices does not exceed five.
If your equipment is in need of repair, contact your local sales representative,
service representative, or distributor directly.
!
CANADA - EMI NOTICE:
This Class B digital apparatus meets all requirements of the Canadian
interference-causing equipment regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
règlement sur le matérial brouilleur du Canada.
Japan Notices
This is a Class B product based on the standard of the Voluntary Control
Council for Interference from Information Technology Equipment
(VCCI). If this is used near a radio or television receiver in a domestic
environment, it may cause radio interference. Install and use the
equipment according to the instruction manual.
This chapter provides basic instructions for connecting the router to a
computer or a LAN and to the Internet using DSL. The first part provides
instructions to set up the hardware, and the second part describes how to
prepare your PC for use with the router.
It is assumed that you have already subscribed to DSL service with your
Internet service provider (ISP).
Shut down your PC and any other equipment before connecting it to the
router. To connect your router:
1 Verify that the router’s power switch is in the Off (outward) position.
Verify that any PCs and other LAN devices you will attach (such as hubs
or switches) are turned off.
2 Use the provided modular phone cable to connect the LINE jack of the
router to your RJ11 wall jack.
3 Use the provided Ethernet cable to connect your computer to the router.
Attach one end of the Ethernet cable to one of the LAN ports on the back
of the router and connect the other end to the Ethernet port or Network
Interface Card (NIC) in your PC.
Connect any other PCs, hubs, and switches to the remaining LAN ports.
Either a crossover or a straight-through Ethernet cable can be used: the
router determines the type of signal required.
4 Connect the cylindrical power plug into the POWER connector on the
back of the device. Next:
— If you have a wall-mount adapter, plug the AC adapter into a wall
outlet or a power strip.
— If you have a table-top adapter, use the AC power cord to connect the
adapter to a wall outlet or power strip.
The supplied power adapter may look different than the one illustrated
here.
5 Turn on your PC and any other LAN devices, such as hubs or switches.
6 Turn on the router using its power switch.
7 Verify that the router's LEDs are illuminated as shown in Table 3.
Table 3: LED Indicators (Sheet 1 of 2)
This LED . . .Should be:
POWERSolid green to indicate that the device is turned on. If this
light is not on, check if the power adapter is attached to the
router and plugged into an AC power source.
xDSL ACTSolid green to indicate that the router can communicate
with your ISP via ADSL, flashing when the device is
sending or receiving data over the ADSL connection, or
blinking when the router is trying to connect to your ISP.
xDSL LNKFlashing when the device is sending or receiving data over
LAN 1–4Solid green to indicate that the device can communicate
with your PC via Ethernet, or flashing when the router is
sending or receiving data over Ethernet.
If the LEDs are illuminated as expected, the router is working properly.
Configuring Your Computer
Before you can access the router over the LAN you have to configure your
PC's TCP/IP address to be 192.168.1.x (where x is any number between 3 and
254), with a subnet mask of 255.255.255.0. Your router's default IP address is
192.168.1.1.
If you know the version of Windows that you use, go to the appropriate
section below to learn how to set the IP address of your PC. To determine the
version of Windows running on your PC, click on the Windows Start button,
then click on Run... in the Start menu. Type winver in the Open selection box
and click on OK.
1 In the Windows task bar, click on the Start button, and then click on
Control Panel.
2 Double-click on the Network Connections icon.
3 In the LAN or High-Speed Internet window, right-click on the icon
corresponding to your network interface card (NIC), and select
Properties. (Often this icon is labeled Local Area Connection). The Local
Area Connection dialog box displays with a list of currently installed
network items.
4 Ensure that the check box to the left of the item labeled Internet Protocol
6 Click on OK twice to confirm your changes, and close the Control Panel.
1 In the Windows task bar, click on the Start button, point to Settings, and
then click on Control Panel.
2 Double-click on the Network and Dial-up Connections icon.
3 In the Network and Dial-up Connections window, right-click on the Local
Area Connection icon, and then select Properties.
The Local Area Connection Properties dialog box display a list of
currently installed network components. If the list includes Internet
Protocol (TCP/IP), the protocol has already been enabled; skip to Step 10.
4 If Internet Protocol (TCP/IP) does not appear as an installed component,
click on Install.
5 In the Select Network Component Type dialog box, select Protocol, and
then click on Add.
6 Select Internet Protocol (TCP/IP) in the Network Protocols list, and then
click on OK.
You may be prompted to install files from your Windows 2000
installation CD or other medium. Follow the instructions to install the
files.
7 If prompted, click on OK to restart your computer with the new settings.
8 After restarting your PC, double-click on the Network and Dial-up
Connections icon in the Control Panel.
9 In Network and Dial-up Connections window, right-click on the Local
Area Connection icon, and then select Properties.
10 In the Local Area Connection Properties dialog box, select Internet
Protocol (TCP/IP), and then click on Properties.
11 In the Internet Protocol (TCP/IP) Properties dialog box, click on the radio
button labeled Use the following IP address. Type an address between
192.168.1.3 and 192.168.1.254 in the IP Address field and 255.255.255.0
in the Subnet Mask field.
12 Click on OK twice to confirm and save your changes, and then close the
Control Panel.
1 In the Windows task bar, click on the Start button, point to Settings, and
then click on Control Panel.
2 Double-click on the Network and Dial-up Connections icon.
3 In the Network and Dial-up Connections window, right-click on the
Network icon, and then select Properties.
The Network Properties dialog box displays a list of currently installed
network components. If the list includes Internet Protocol (TCP/IP), the
protocol has already been enabled; skip to Step 11.
4 If Internet Protocol (TCP/IP) does not appear as an installed component,
click on Add.
5 In the Select Network Component Type dialog box, select Protocol, and
then click on Add.
6 Select Microsoft in the Manufacturers box.
7 Select Internet Protocol (TCP/IP) in the Network Protocols list, and then
click on OK.
You may be prompted to install files from your Windows Me installation
CD or other media. Follow the instructions to install the files.
8 If prompted, click on OK to restart your computer with the new settings.
9 After restarting your PC, double-click on the Network and Dial-up
Connections icon in the Control Panel.
10 In Network and Dial-up Connections window, right-click on the Network
icon, and then select Properties.
11 In the Network Properties dialog box, select TCP/IP, and then click on
Properties.
12 In the TCP/IP Settings dialog box, click on the radio button labeled Use
the following IP address. Type an address between 192.168.1.3 and
13 Click on OK twice to confirm and save your changes, and then close the
Windows 95 and Windows 98
1 In the Windows task bar, click on the Start button, point to Settings, and
2 Double-click on the Network icon.
3 If TCP/IP does not appear as an installed component, click on Add. The
4 Select Protocol, and then click on Add.
192.168.1.254 in the IP Address field and 255.255.255.0 in the Subnet
Mask field.
Control Panel.
then click on Control Panel.
The Network dialog box displays a list of currently installed network
components. If the list includes TCP/IP, the protocol has already been
enabled. Skip to step 9.
Select Network Component Type dialog box appears.
The Select Network Protocol dialog box appears.
5 Click on Microsoft in the Manufacturers list box, and then click on TCP/
IP in the Network Protocols list box.
6 Click on OK to return to the Network dialog box, and then click on OK
again.
You may be prompted to install files from your Windows 95/98
installation CD. Follow the instructions to install the files.
7 Click on OK to restart the PC and complete the TCP/IP installation.
8 After restarting your PC, open the Control Panel window, and then click
on the Network icon.
9 Select the network component labeled TCP/IP, and then click on
Properties.
If you have multiple TCP/IP listings, select the listing associated with
your network card or adapter.
10 In the TCP/IP Properties dialog box, click on the IP Address tab.
11 Click in the radio button labeled Use the following IP address. Type an
address between 192.168.1.3 and 192.168.1.254 in the IP Address field
and 255.255.255.0 in the Subnet Mask field.
12 Click on OK twice to confirm and save your changes. You will be
prompted to restart Windows. Click on Yes.
Windows NT 4.0
1 In the Windows NT task bar, click on the Start button, point to Settings,
and then click on Control Panel.
2 In the Control Panel window, double click on the Network icon.
3 In the Network dialog box, click on the Protocols tab.
The Protocols tab displays a list of currently installed network protocols.
If the list includes TCP/IP, the protocol has already been enabled. Skip to
Step 9.
4 If TCP/IP does not appear as an installed component, click on Add.
5 In the Select Network Protocol dialog box, select TCP/IP, and then click
on OK.
You may be prompted to install files from your Windows NT installation
CD or other medium. Follow the instructions to install the files.
After all files are installed, a window appears to inform you that a TCP/IP
service called DHCP can be set up to dynamically assign IP information.
6 Click on Yes to continue, and then click on OK, if prompted, to restart
your computer.
7 After restarting your PC, open the Control Panel window, and then
double-click on the Network icon.
8 In the Network dialog box, click on the Protocols tab.
9 In the Protocols tab, select TCP/IP, and then click on Properties.
10 In the Microsoft TCP/IP Properties dialog box, click on the radio button
labeled Use the following IP address. Type an address between
192.168.1.3 and 192.168.1.254 in the IP Address field and 255.255.255.0
in the Subnet Mask field.
11 Click on OK twice to confirm and save your changes, and then close the
Control Panel.
Logging in to Your Router
This section shows how to connect to the router's web interface, configure
settings, and observe some statistics of your Internet connection.
1 Open your Web browser, and type the following URL in the address/
location box, and press Enter:
http://192.168.1.1
This is the default IP address for the LAN port on the router.