Zetex ZR404005F25, ZR404005N825, ZR40401N825, ZR40401R25, ZR404005R25 Datasheet

...
0 (0)
PRECISION 2.5 VOLT MICROPOWER VOLTAGE REFERENCE
ISSUE 3 - MARCH 1998
ZR4040-2.5
DEVICE DESCRIPTION
The ZR4040-2.5 uses a bandgap circuit design to achieve a precision micropower voltage reference of 2.5 volts. The device is available in small outline surface mount packages, ideal for applications where space saving is important, as well as packages for through hole requirements.
The ZR4040-2.5 design provides a stable voltage without an external capacitor and is stable with capacitive loads. The ZR4040-2.5 is recommended for operation between 60µA and 15mA and so is ideally suited to low power and battery powered applications.
Excellent performance is maintained to an absolute maximum of 25mA, however the rugged design and 20 volt processing allows the reference to withstand transient effects and currents up to 200mA. Superior switching capability allows the device to reach stable operating conditions in only a few microseconds.
SCHEMETIC DIAGRAM
FEATURES
Small outline SO8 and SOT23 packages
TO92 style package
No stabilising capacitor required
Typical TC 30ppm/°C
Typical slope resistance 0.4
2% 1% and 0.5 % tolerance
Industrial temperature range
Operating current 60µA to 15mA
Transient response, stable in less than
10µs
APPLICATIONS
Battery powered and portable
equipment. Metering and measurement systems.
Instrumentation.
Test equipment.
Data acquisition systems.
Precision power supplies.
V
R
G
nd
4-173
ZR4040-2.5
ABSOLUTE MAXIMUM RATING
Reverse Current 25mA Forward Current 25mA Operating Temperature -40 to 85°C Storage Temperature -55 to 125°C
Power Dissipation (T
SOT23 330mW SO8 625mW E-Line, 3 pin (TO92) 500mW
ELECTRICAL CHARACTERISTICS TEST CONDITIONS (Unless otherwise stated) T
SYMBOL PARAMETER
V
I I
R
MIN
R
Reverse Breakdown Voltage
Minimum Operating Current 25 60 Recommended Operating
Current
T
Average Reverse
C
Breakdown Voltage Temp. Co.
R
§ Slope Resistance 0.4 2
S
Z
R
E
N
Reverse Dynamic Impedance IR =1mA
Wideband Noise Voltage IR= 1mA
CONDITIONS LIMITS TOL.
=150µA
I
R
I
to
R(min)
I
R(max)
f = 100Hz I
=0.1 I
AC
R
f = 10Hz to
10kHz
=25°C
amb
MIN TYP MAX
2.4875
2.475
2.45
0.06 15 mA
=25°C)
amb
UNITS
%
2.5
2.5
2.5
2.5125
2.525
2.55
0.5 1 2
V
µA
30 100 ppm/°C
0.3 0.8
45
µV
(rms)
(
V
V
T
Note: V
=
C
R(max)
R(max
V
- V
)
x (
R
R(min)
) x 1000000
R(min
)
T
T
(
max
)
)
(
min
)
is the maximum deviation in reference voltage measured over the full operating temperature range.
V
Change
(
I
(
§
min) to I
R
R
=
S
R
I
(
max
)
R
(
max
R
I
(
min
)
R
60
)
50
A
µ
( t
40
urren
30
e C
))
evers R
20
10
0
0.2 0.6
1.0 1.8 2.61.4 2.2
°C
=85
A
T
°C
=25
A
T
-40°C
=
A
T
Reverse Voltage (V)
Reverse Characteristics