OCT Imaging Model 5000 Model 500
Methodology Spectral domain OCT Spectral domain OCT
Scan speed 27,000 - 68,000 A-scans per second
1
27,000 - 68,000 A-scans per second
1
A-scan depth 2.0 mm (in tissue), 1024 points 2.0 mm (in tissue), 1024 points
Axial resolution 5 µm (in tissue) 5 µm (in tissue)
Transverse resolution 15 µm (in tissue) 15 µm (in tissue)
Fundus Imaging Model 5000 Model 500
Methodology Line scanning opthalmoscope (LSO) Live OCT Fundus
TM
Live fundus image During alignment and during OCT scan During alignment
Field of view 36 degrees W x 30 degrees H 36 degrees W x 22 degrees H
Frame rate > 20 Hz > 1.7 Hz
Transverse resolution 25 µm (in tissue) 45 µm (in tissue)
Iris Imaging Model 5000 Model 500
Methodology CCD camera CCD camera
Resolution 1280 x 1024 1280 x 1024
Live iris image During alignment During alignment
Electrical and Physical Model 5000 Model 500
Weight 80 lbs (36 kg) 76 lbs (34 kg)
Dimensions of instrument 26L x 18W x 21H (in)
65L x 46W x 53H (cm)
26L x 18W x 21H (in) 65L x 46W x 53H (cm)
Dimensions of table 39L x 22W (in)
99L x 56W (cm)
39L x 22W (in) 99L x 56W (cm)
Fixation Internal, external Internal, external
Internal fixation focus adjustment -20D to +20D (diopters) -20D to +20D (diopters)
Electrical rating (115V) Single Phase, 100–120V~ systems: 50/60Hz, 5A Single Phase, 100–120V~ systems: 50/60Hz, 5A
Electrical rating (230V) Single Phase, 220–240V~ systems: 50/60Hz, 2.5A Single Phase, 220–240V~ systems: 50/60Hz, 2.5A
Internal Computer Model 5000 Model 500
Operating system/processor Windows
®
7, i7 Intel® processor Windows® 7, i7 Intel® processor
Memory 4 GB 4 GB
Hard drive/internal storage ≥ 750 GB
> 80,000 scans
≥ 750 GB > 80,000 scans
Display Integrated 19“ color flat panel display Integrated 19“ color flat panel display
USB ports 6 ports 6 ports
CIRRUS™ HD-OCT Technical Specifications
Technical specifications subject to change.
Carl Zeiss Meditec, Inc.
5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com/cirrus
Carl Zeiss Meditec AG
Goeschwitzer Str. 51-52 07745 Jena Germany www.meditec.zeiss.com/cirrus
0297
© 2012 Carl Zeiss Meditec, Inc. All rights reserved. The contents of this brochure may differ from the current
status of approval of the product in your country. Please contact your local representative. 1112 5M
International Version Publication No: 000000-2037-501 CZ-XI/2012
1. All existing scan patterns in version 6.5 software run at 27,000 A-scans per second. The fundus image acquired with the Model 500 will be captured at 68,000 A-scans per second.
Loading...