Featu res and s pecifications indic ated
herein an d on our web site are subject
to ch ange at a ny time w ithout notice.
Check our websit e, wolfappliance .com
for th e most up-to -dat e sp ecificat ions.
I M P O R T A N T N O T E
As you foll ow these instructi ons, you
will notice warning and caution sy mbols.
This blocked information i s important
for th e safe and efficient in stallat ion of
Wolf eq uipment. There are two ty pes of
potential ha zards th at may o ccur during
installation.
®
WOLF
is a registered trademark of Wolf Appliance, Inc.
signals a situation w here m inor
injury or product d amage may o ccur
if you do not fo llow instructi ons.
states a hazard that may cause
serious injury or death if preca utions
are not followed.
Another footnot e we would li ke to
iden tify is IMPORTANT NOTE: Thi s
high lights i nformation that i s especially
relevant to a problem-free i nstallation.
W O L F V E N T I L A T I O N
W O L F V E N T I L A T I O N
Ventilation is an integral part of any kitchen.
Proper ventilation provides a cleaner, more
enjoyable cooking environment by removing the
cooking vapors and odors from the cooking area.
From downdrafts to 66" (1676) wide wall hoods,
Wolf has ventilation products to satisfy all of
your customers’ needs and preferences. The
chart on the following page gives ventilation
recommendations for each product line.
Installation instructions shipped with each Wolf
ventilation product provide detailed specifications. These instructions can also be found on
our website, wolfappliance.com. Work with a
qualified installer or Wolf authorized service
center technician to ensure that all local codes
are followed. Consult a qualified HVAC engineer
for specific installation and ducting applications.
The inform atio n and images in t his guide are the
copyr ight property of Wolf Appliance, I nc., a n
affiliate of Sub-Z ero, Inc. Ne ither this book nor any
informati on or images contained herein m ay be
copied or used in whole or in par t without th e
express writt en permissi on of Wolf Applianc e, Inc.,
an affiliate of Sub -Zero, Inc.
S E L E C T I N G A V E N T I L A T I O N S Y S T E M
ooktop or Pro Ventilation
C
Wolf ventilation systems are divided into two
categories: Cooktop ventilation and Pro ventilation. Wolf cooktop wall and island hoods are
recommended for use with Wolf induction,
electric, gas and integrated cooktops and should
be at least as wide as the cooking surface. Wolf
downdraft ventilation systems are recommended
for use with Wolf framed induction, electric and
gas cooktops and some integrated modules.
They cannot be installed with unframed induction and electric cooktops and steamer and fryer
modules. They are not recommended for use
with the electric grill module. A Pro ventilation
hood is recommended for use with Wolf dual
fuel ranges, gas ranges, sealed burner rangetops
and gas rangetops.
A downdraft can be used with sealed burner
rangetop Models SRT304 and SRT366. An
accessory trim kit (810215) is required for this
installation. Contact your dealer for details.
The chart below provides a quick reference
of recommended ventilation equipment for
specific Wolf cooking products.
pdraft or Downdraft
U
The choice between updraft ventilation and
downdraft ventilation will depend on several
factors, most notably the cooking appliance
being used as well as the installation and installation location. Updraft ventilation, or overhead
hood, will normally be a more effective ventilation option. Cooking vapors naturally rise,
making it easier to collect and remove them from
the cooking area.
Wolf downdrafts provide another effective
option for ventilation. The 9" (229) telescope
rises up from the countertop and draws cooking
vapors away from the cooking surface. Downdraft ventilation is a great option in installations
where updraft ventilation is either not wanted or
is not a viable option.
COOKTOP S A ND MODU LES
Framed Induction Cooktops
Unframed Induction Cooktops
Framed Electric Cooktops
Unframed Electric Cooktops
Gas Cooktops
Integrated Modules –
CT15I/S and IM15/S
IG15/S, IS15/S and IF15/S
RANGES AND RANGETOPS
Dual Fuel Ranges
Sealed Burner Rangetops –
SRT304 and SRT366
All Other Models
Gas Ranges
Gas Rangetops
Dimensions i n
parenthe ses are i n
millimeters unless
otherwise sp ecified.
COOKTOP VENTILATIONPRO VENTILATION
WALL HOODSISLAND HOODSDOWNDRA FTSWALL H OOD SISLAND H OOD SLINERS
4
W O L F V E N T I L A T I O N
S E L E C T I N G A V E N T I L A T I O N S Y S T E M
FM Recommendations
C
Ventilation performance is measured in Cubic
Feet per Minute, or CFM. The higher the CFM,
the greater the amount of air that is evacuated
through the ventilation system. CFM recommendations are based on the cooking appliance
output. Wolf recommends 1 CFM per 100
Btu/hr.
The chart on page 53 provides minimum CFM
recommendations for all Wolf cooking products.
Internal, In-Line or Remote Blower
A ventilation system must include a blower
assembly. Most Wolf ventilation hoods and
downdrafts are sold as a shell only. There are a
few exceptions where internal blowers are
included. An internal, in-line or remote blower
assembly must be selected to accommodate the
cooking appliance requirements and homeowner
preferences.
The charts on pages 55–56 provide blower
options for all Cooktop and Pro ventilation
products.
Internal blowers are mounted inside the hood
canopy or downdraft blower box. In-line blowers
are mounted in between the hood and the
exterior of the home. Remote blowers are
mounted on the roof, or in some cases, an
exterior wall. Remote mounted blowers will
minimize the amount of blower noise, but will
not eliminate the noise completely.
Some blower noise is considered normal while
the blower is operational. If noise is a concern, a
remote blower is recommended. To reduce noise
further for remote blower applications, an attenuator may be necessary. Consult a qualified
HVAC engineer for specific installation and
ducting applications.
idth Guidelines
W
The minimum hood width recommended for wall
installations should be equal to the width of the
cooktop or range. If the space is not restricted, a
wider hood should be used to increase the
capture area.
Island installations require a greater capture area.
It is recommended that Wolf island hoods
overlap the width of the cooktop or range by a
minimum of 3" (76) on either side.
The width of the Wolf downdraft system should
match the width of the cooktop.
Ceiling Height
When selecting a Wolf ventilation hood, make
sure there is enough ceiling height to accommodate the hood. This can be determined by adding
the floor-to-countertop height plus the recommended spacing between the countertop and
the bottom of the hood plus the height of the
hood. Overall dimensions for all Wolf ventilation
products are provided in this guide.
Installation of cooktop wall and island hoods
should be 24" (610) to 30" (762) from the
bottom of the hood to the countertop. For
additional ceiling height guidelines for these
chimney-style hoods, refer to pages 19–20.
Installation of Pro wall, wall chimney and island
hoods and hood liners should be 30" (762) to
36" (914) from the bottom of the hood to the
countertop.
Recirculating Ventilation
Recirculating ventilation units are installed on
top of a ventilation hood; no ductwork is
required. Recirculating units recycle the air
through a charcoal filter and return it to the
kitchen. Wolf recirculating units are for use with
cooktop low-profile hoods with an internal
blower and Pro wall hood Models PW302210,
PW362210, PW302418, PW362418, PW302718
and PW362718.
IMPORTANT NOTE: This type of ventilation will
not remove heat, moisture or combustion gases
from the air. It will also be less effective in
reducing odors and smoke.
5
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P C H I M N E Y H O O D S
odel CTWH30
M
Mode l CTWH36
Mode l IH4227
W O L F
W A R R A N T Y
Wolf produc ts are
covered by a two
and five year
resident ial warrant y
(exclusions apply) .
See warranty
details at the end
of th is guide.
Wolf cooktop chimney wall hoods are 21" (533)
deep and come in 30" (762) and 36" (914)
widths. The cooktop chimney island hood is 42"
(1067) wide and 27" (686) deep. The hoods are
seamless stainless steel in the classic finish.
Wolf cooktop chimney wall and island hoods are
recommended for use with Wolf induction,
electric and gas cooktops as well as with integrated modules and should be at least as wide
as the cooking surface. A Pro ventilation hood is
recommended for use with Wolf dual fuel
ranges, gas ranges, sealed burner rangetops and
gas rangetops. Refer to page 30 for Pro ventilation specifications.
Cooktop chimney wall and island hoods come
with a telescopic chimney flue extension which
allows you to reach a ceiling height of 8' (2.4 m)
to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available as a sales accessory.
Installation of cooktop chimney wall and island
hoods should be 24" (610) to 30" (762) from the
bottom of the hood to the countertop.
Wolf cooktop chimney hoods are shipped
without the blower assembly. Internal, in-line or
remote blower assemblies are available as a
sales accessory.
IMPORTANT NOTE: Install these ventilation
hoods only with a Wolf blower.
Refer to the Cooktop Ventilation chart on page
55 for blower options for each cooktop hood.
ooktop Chimney Hood Features
C
Front-Mounted Controls. Easy-access controls
with LED indicator lights.
Three-Speed Blower Control. Low, medium and
high blower speed control.
Filter Clean Timer. Timer lets you know when
the filter needs cleaning. The filter LED will
illuminate after approximately 30 hours of
operation.
Heat Sentry Feature. This feature automatically
turns the unit on when heat is sensed and
adjusts blower speed. The Heat Sentry feature
is always in wait and is activated when exhaust
temperature from hood reaches 200˚F (95˚C).
At this temperature, blower motor speed will
automatically adjust to the next highest speed.
Delay-Off Feature. This feature will allow the
blower to continue running at the selected speed
for a short time after you have left the cooking
area. If the blower is on high speed and the
Delay-Off feature is activated, the blower will
continue to run at high speed for five minutes.
Then it will go to low speed for five minutes
before the blower is turned off.
Telescopic Chimney. Chimney flue extension fits
8' (2.4 m) to 9' (2.7 m) ceilings. A flue extension
to accommodate 10' (3 m) ceilings is available.
Halogen Lighting. Sealed lighting with three
settings.
UL Listed. Listed to US and Canadian safety
standards.
Dimensions i n
parenthe ses are i n
millimeters unless
otherwise sp ecified.
6
M O D E L O P T I O N S
Cooktop Chimney Wall Ho ods
30" ( 762) WidthCTWH30
36" ( 914) WidthCTWH36
Cooktop Chimney Island Hood
42" ( 1067) WidthIH42 27
W O L F C O O K T O P V E N T I L A T I O N
67/8"
(175)
3
0
1
/2" TO 4
8
1
/2"
(775 – 1232)
OVERALL HEIGHT
1
9
1
/8"
(
486)
30" (762)
OVERALL WIDTH
41/2"min
(
114)
1
8"
(457)
1
2"
(305)
21" (533)
OVERALL DEPTH
19/16"
(
40)
6
"
(152)
Model CTWH30
C O O K T O P C H I M N E Y W A L L H O O D
Model CTWH30
Installation TypeChimney Wall Hood
FinishClassic Stainless Steel
Overall Width30" (762)
Overall Height30
1
/2" (775) minimum to
481/2" (1232) full extension
Overall Depth21" (533)
Blower Options
450 CFM Internal
600 or 1100 CFM In-Line
600, 900, 1200 or 1500 CFM Remote
Installation Height24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size8" (203) round
DischargeVertical
Electrical Supply110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen BulbsTwo T4, 12 V, 20 W bulbs
included
Shipping Weight
(shell only)85 lbs (39 kg)
Features
Heavy-duty, seamless stainless steel
Telescopic chimney flue extension
Front-mounted controls with LED indicator
Three-speed blower control
Filter clean timer
Delay-Off feature
Heat Sentry feature
Dishwasher-safe, aluminum mesh filters
Sealed halogen lighting with three settings
Accessories
Flue extension to accommodate 10' (3 m)
ceilings
30" (762) x 30" (762) wall shield
8" (203) to 10" (254) round transition for
remote blower
Mode l CTWH30
M O D E L C T W H 3 0
Wall ho od comes
complete wit h
filters, halogen
bulbs, transitio n and
backdraft dam per.
Internal, in -line and
remote bl owers , as
well as op tional
accessories , are
available throug h
your Wolf dealer.
Refer to page 22
for ad ditiona l
informati on on
accessories .
7
191/8"
(
486)
45/16"m
in
(110)
3211/16" TO507/8"
(
830 – 1292)
O
VERALL HEIGHT
357/16" (
900)
O
VERALL WIDTH
18"
(457)
12"
(305)
21" (533)
OVERALL DEPTH
91/4"
(235)
19/16"
(40)
811/16"
(221)
Model CTWH36
W O L F C O O K T O P V E N T I L A T I O N
Model CTWH36
M O D E L C T W H 3 6
Wall ho od comes
complete wit h
filters, halogen
bulbs, transitio n and
backdraft dam per.
Internal, in -line and
remote bl owers , as
well as op tional
acce ssories , are
available throug h
your Wolf dealer.
Refer to page 22
for ad ditiona l
informati on on
acce ssories .
C O O K T O P C H I M N E Y W A L L H O O D
Model CTWH36
Installation TypeChimney Wall Hood
FinishClassic Stainless Steel
Overall Width357/16" (900)
Overall Height32
11
/16" (830) minimum to
507/8" (1292) full extension
Overall Depth21" (533)
Blower Options
600 or 900 CFM Internal
600 or 1100 CFM In-Line
600, 900, 1200 or 1500 CFM Remote
Installation Height24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size8" (203) round
DischargeVertical
Electrical Supply110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen BulbsThree T4, 12 V, 20 W bulbs
included
Shipping Weight
(shell only)100 lbs (45 kg)
Features
Heavy-duty, seamless stainless steel
Telescopic chimney flue extension
Front-mounted controls with LED indicator
Three-speed blower control
Filter clean timer
Delay-Off feature
Heat Sentry feature
Dishwasher-safe, aluminum mesh filters
Sealed halogen lighting with three settings
Accessories
Flue extension to accommodate 10' (3 m)
ceilings
36" (914) x 30" (762) wall shield
8" (203) to 10" (254) round transition for
remote blower
Dimensions i n
parenthe ses are i n
millimeters unless
otherwise sp ecified.
8
W O L F C O O K T O P V E N T I L A T I O N
339/16" TO 471/16"
(853 – 1195)
O
VERALL HEIGHT
42" (1067)
OVERALL WIDTH
18"
(
457)
12"
(
305)
27" (686)
OVERALL DEPTH
195/16"
(491)
5
"
m
in
(127)
91/4"
(
235)
19/16"
(40)
Model IH4227
Mode l IH4227
C O O K T O P C H I M N E Y I S L A N D H O O D
Model IH4227
Installation TypeChimney Island Hood
FinishClassic Stainless Steel
Overall Width42" (1067)
Overall Height33
9
/16" (853) minimum to
6
471/
1
"(1195) full extension
Overall Depth27" (686)
Blower Options
600 or 900 CFM Internal
600 or 1100 CFM In-Line
600, 900, 1200 or 1500 CFM Remote
Installation Height24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size8" (203) round
DischargeVertical
Electrical Supply110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen BulbsFour T4, 12 V, 20 W bulbs
included
Shipping Weight
(shell only)110 lbs (50 kg)
Features
Heavy-duty, seamless stainless steel
Telescopic chimney flue extension
Front-mounted controls with LED indicator
Three-speed blower control
Filter clean timer
Delay-Off feature
Heat Sentry feature
Dishwasher-safe, aluminum mesh filters
Sealed halogen lighting with three settings
Accessories
Flue extension to accommodate 10' (3 m)
ceilings
8" (203) to 10" (254) round transition for
remote blower
M O D E L I H 4 2 2 7
Island hood comes
complete wit h
filters, halogen
bulbs, transitio n and
backdraft dam per.
Internal, in -line and
remote bl owers , as
well as op tional
accessories , are
available throug h
your Wolf dealer.
Refer to page 22
for ad ditiona l
informati on on
accessories .
9
W O L F C O O K T O P V E N T I L A T I O N
8' TO 9'
(2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
24" TO 30"*
(610 – 762)
TO
COUNTERTOP
21"
(533)
E
4" (102)
6"
(152)
30" OR 357/16"
(762 or 900)
481/2" OR 507/8"
(1232 or 1292)
MAXIMUM
HEIGHT OF HOOD
301/2" OR 3211/16"
(775 or 830)
MINIMUM
HEIGHT OF HOOD
*8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling
will allow for a maximum height above the countertop of 29
1
/2" (749) for Model CTWH30 and 275/16" (694) for Model CTWH36.
LOCATION OF
ELECTRICAL
C O O K T O P C H I M N E Y H O O D S
I N S T A L L A T I O N
Refer to the insta llation instructi ons
shipped with ea ch
Wolf ventil ation
product fo r detailed
specificatio ns.
These i nstructions
can a lso be found
on ou r web site,
wolfappliance.co m.
lectrical Requirements
E
Wolf cooktop chimney wall and island hoods
require a separate, grounded 120 V AC, 60 Hz
power supply. The service should have its own
15 amp circuit breaker. Placement of the electrical supply is not critical as long as you provide a
minimum of 12" (305) of 120 V AC power cable
for the wall hood and 6' (1.8 m) for the island
hood.
Locate electrical within the shaded area shown
in the installation illustration for your model
below and on the following page.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
lower Considerations
B
Wolf cooktop chimney wall and island hoods are
shipped without the blower assembly. Internal,
in-line and remote blower assemblies are available. For wall hoods, the remote blower can be
mounted on the roof or an exterior wall. For
island hoods, the remote blower will be mounted
on the roof.
The blower will vary in size, which is dictated by
the cooking surface, the volume of air that needs
to be moved and the length of the duct run.
A remote-mounted blower will minimize the
amount of blower noise but will not eliminate
the noise completely. All remote blowers will
require a transition to a 10" (254) duct.
IMPORTANT NOTE: Install these ventilation
hoods only with a Wolf blower.
Refer to the Cooktop Ventilation chart on page
55 for blower options.
Dimensions i n
parenthe ses are i n
millimeters unless
otherwise sp ecified.
C O O K T O P W A L L H O O D I N S T A L L A T I O N
10
4
2"
(1067)
4
7
1
/16" (1195)
MAXIMUM
HEIGHT OF HOOD
3
3
9
/16" (853)
MINIMUM
HEIGHT OF HOOD
27" (686)
LOCATION OF ELECTRICAL
ON CEILING THROUGH
TOP OF HOOD
8'
TO 9
'
(
2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
2
4"
TO 3
0"*
(
610 – 762)
TO
COUNTERTOP
*8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling
will allow for a maximum height above the countertop of 26
7
/16" (672).
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P I S L A N D H O O D I N S T A L L A T I O N
I N S T A L L A T I O N
Refer to the insta llation instructi ons
shipped with ea ch
Wolf ventil ation
product fo r detailed
specificatio ns.
These i nstructions
can a lso be found
on ou r web site,
wolfappliance.co m.
11
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P L O W - P R O F I L E H O O D S
Mode l CTEWH3 0I
Mode l CTEWH3 6(I)
Mode l CTEWH4 5(I)
Mode l CTEIH4 2I
Wolf cooktop low-profile wall hoods are 173/4"
(451) deep and come in 30" (762), 36" (914) and
45" (1143) widths. The cooktop low-profile
island hood is 42" (1067) wide and 215/8" (549)
deep. The hoods are classic stainless steel with
a black glass front panel. Wall and island hoods
are available with an internal blower or some
wall hood models have in-line and remote
blower options.
Wolf cooktop low-profile wall and island hoods
are recommended for use with Wolf induction,
electric and gas cooktops and integrated
modules. For Wolf ranges and rangetops, a Pro
ventilation hood is recommended.
Cooktop low-profile wall and island hoods come
with a telescopic chimney flue extension which
allows you to reach a ceiling height of 8' (2.4 m)
to 9' (2.7 m) with a finished look.
Refer to the Cooktop Ventilation chart on page
55 for blower options for each cooktop hood.
ooktop Low-Profile Hood Features
C
Stainless steel construction with classic finish
500 CFM internal blower included with (I)
models—in-line or remote blower options for
Models CTEWH36 and CTEWH45
30" (762) x 30" (762) wall shield
Recirculating kit with charcoal filter
C T E W H 3 0 I
Wall ho od includes a
500 C FM internal
blower and c omes
complete wit h
filters, halogen
bulbs, transitio n and
backdraft dam per.
Refer to page 22
for in formation on
accessories available through you r
Wolf de aler.
13
201/8"
(511)
31/8" (79)
57/8" (149)
TO
183/8" (467)
107/8"
(276)
97/8"
(251)
291/8" (
740)
TO
411/2" (1054)
O
VERALL
HEIGHT
36" (914)
OVERALL WIDTH
173/4"
(451)
OVERALL DEPTH
Model CTEWH3 6(I)
W O L F C O O K T O P V E N T I L A T I O N
Model CTEWH36(I)
C T E W H 3 6 ( I )
Model CTEWH3 6I
includes a 500 CF M
internal blower.
Internal, in -line and
remote bl owers are
available for Model
CTEWH36. Bot h
wall hoods c ome
complete wit h
filters, halogen
bulbs, transitio n and
backdraft dam per.
Refer to page 22
for in formation on
acce ssories available through you r
Wolf de aler.
C O O K T O P L O W - P R O F I L E W A L L H O O D
Model CTEWH36(I)
Installation TypeLow-Profile Wall Hood
FinishClassic Stainless Steel
Overall Width36" (914)
Overall Height29
1
/8" (740) minimum to
411/2" (1054) full extension
Overall Depth173/4" (451)
CTEWH36I Blower500 CFM Internal
CTEWH36 Blower Options
600 or 1100 CFM In-Line
600, 900, 1200 or 1500 CFM Remote
Installation Height24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size6" (152) round
DischargeVertical
Electrical Supply110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen BulbsFour T4, 12 V, 20 W bulbs
included
Shipping Weight
CTEWH36 (shell)51 lbs (23 kg)
CTEWH36I57 lbs (26 kg)
Recirculating kit with charcoal filter (CTEWH45I
only)
C T E W H 4 5 ( I )
Mode l CTEWH4 5I
includes a 500 CF M
internal blower.
Internal, in -line and
remote bl owers are
available for Model
CTEWH45. Bot h
wall hoods c ome
complete wit h
filters, halogen
bulbs, transitio n and
backdraft dam per.
Refer to page 22
for in formation on
accessories available through you r
Wolf de aler.
15
227/8"
(581)
31/8" (79)
21/8" (54)
TO
151/2" (394)
107/8"
(276)
121/8"
(308)
2
8
1
/4" (
718)
TO
411/2" (1054)
O
VERALL
HEIGHT
42" (1067)
OVERALL WIDTH
215/8" (549)
OVERALL DEPTH
Model CTEIH4 2I
W O L F C O O K T O P V E N T I L A T I O N
Model CTEIH42I
C T E I H 4 2 I
Island hood includes
a 5 00 CFM inter nal
blower and c omes
complete wit h
filters, halogen
bulbs, transitio n and
backdraft dam per.
Refer to page 22
for ad ditiona l
informati on on
acce ssories .
C O O K T O P L O W - P R O F I L E I S L A N D H O O D
Wolf cooktop low-profile wall and island hoods
require a separate, grounded 110/120 V AC,
60 Hz power supply. The service should have its
own 15 amp circuit breaker.
Locate electrical within the shaded area shown
in the installation illustration for your model
below and on the following page.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
lower Considerations
B
Wolf low-profile wall and island cooktop hoods
are available with an internal blower. Wall hood
Models CTEWH36 and CTEWH45 can be used
with an in-line or remote blower assembly.
IMPORTANT NOTE: Install these ventilation
hoods only with a Wolf blower.
The blower will vary in size and is dictated by
the cooking surface, the volume of air that needs
to be moved and the length of the duct run. A
straight, short duct run with a limited number of
elbows and transitions will allow the ventilation
hood to perform most efficiently.
A remote mounted blower will minimize the
amount of blower noise, but will not eliminate
the noise completely.
Refer to the Cooktop Ventilation chart on page
55 for blower options.
I N S T A L L A T I O N
Refer to the insta llation instructi ons
shipped with ea ch
Wolf ventil ation
product fo r detailed
specificatio ns.
These i nstructions
can a lso be found
on ou r web site,
wolfappliance.co m.
L O W - P R O F I L E W A L L H O O D I N S T A L L A T I O N
17
8' TO9'
(2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
24" TO30"
(610 – 762)
TO
COUNTERTOP
42" (1067)
OVERALL WIDTH
281/4" (718)
TO
411/2" (1054)
OVERALL
HEIGHT
LOCATION OF
E
LECTRICAL
ON CEILING
THROUGH TOP
O
F HOOD
215/8" (549)
OVERALL DEPTH
I N S T A L L A T I O N
Refer to the insta llation instructi ons
shipped with ea ch
Wolf ventil ation
product fo r detailed
specificatio ns.
These i nstructions
can a lso be found
on ou r web site,
wolfappliance.co m.
W O L F C O O K T O P V E N T I L A T I O N
L O W - P R O F I L E I S L A N D H O O D I N S T A L L A T I O N
Dimensions i n
parenthe ses are i n
millimeters unless
otherwise sp ecified.
18
W O L F C O O K T O P V E N T I L A T I O N
B
AC
D
MINIMUM
FLUE
EXTENSION
MINIMUM
FLUE
EXTENSION
B
AC
D
C O O K T O P V E N T I L A T I O N H O O D S
ood Placement
H
Wolf cooktop wall and island hoods come with a
telescopic chimney flue extension that allows
you to reach a ceiling height of 8' (2.4 m) to 9'
(2.7 m) with a finished look. A flue extension to
accommodate 10' (3 m) ceilings is available as a
sales accessory for cooktop chimney hoods
only.
Installation of the cooktop wall or island hood
should be 24" (610) to 30" (762) from the
bottom of the hood to the countertop.
To determine placement of the wall or island
hood, you must calculate the height of the
telescopic chimney flue. Refer to the chart for
the minimum and maximum flue extension for
your specific hood. Also refer to the illustrations.
IMPORTANT NOTE: Both sections of the
telescopic chimney flue must be installed in
order for the chimney to be lifted for service.
IMPORTANT NOTE: If the height of the upper
flue section is less than
1
/2" (13), you will need
to modify the flue to affix to the flue attachment
brackets.
alculate Chimney Flue Height
C
1) First measure the total kitchen height from
finished floor to finished ceiling height (A).
8' (2.4 m) or 9' (2.7 m) ceilings are standard.
2) Next, measure the height from the finished
floor to countertop (B). 36" (914) countertop
height is standard.
3) Determine the desired distance from countertop to bottom of hood (C). This dimension
must be between 24" (610) and 30" (762).
IMPORTANT NOTE: 8' (2.4 m) ceilings may not
permit installation of the wall or island hood at
30" (762) above the countertop.
4) To calculate the chimney flue height (D):
D = A – (B + C). This dimension must be
between the minimum and maximum flue
extension for your specific hood as shown in
the chart.
C O O K T O P H O O D S
Flue Extension
ModelMinimumMaximum
CTWH30
CTWH36
IH4227
CTEWH30I
CTEWH36(I)
CTEWH45(I)
CTEWH42I
301/2" (775)481/2" (1232)
3211/16" (830)507/8" (1292)
339/16" (853)471/16" (1195)
291/8" (740)411/2" (1054)
291/8" (740)411/2" (1054)
291/8" (740)411/2" (1054)
281/4" (718)411/2" (1054)
Cooktop Chimney HoodsCooktop Low-Profile Hoods
19
21" (535)
DEPTH OF HOOD
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
301/2" (775) TO
481/2" (1232)
OR
3211/16" (830) TO
507/8" (1292)
HEIGHT
OF HOOD
DUCTWORK
INSTALLATION
THROUGH
R
OOF
DUCTWORK
INSTALLATION
THROUGH
WALL
27" (686)
DEPTH OF HOOD
DUCTWORK
INSTALLATION
T
HROUGH
R
OOF
DUCTWORK
INSTALLATION
THROUGH EAVE –
INTERNAL
BLOWER ONLY
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
339/16" (853)
TO
471/16" (1195)
HEIGHT
OF HOOD
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P C H I M N E Y H O O D S
ucting Considerations
D
IMPORTANT NOTE: All Wolf cooktop hoods
must be vented to the outside. Use only metal
ductwork.
Wolf cooktop wall and island hoods have an 8"
(203) round vertical discharge. Ducting can run
through the roof, external wall or eave. Ducting
through an eave requires an internal blower.
Refer to the illustrations below for ducting
considerations.
A straight, short duct run with a limited number
of elbows and transitions will allow the ventilation hood to perform most efficiently. Wolf
cooktop wall and island hoods will operate most
efficiently when ductwork does not exceed 50'
(15 m) in length. Refer to the chart on page 52
to calculate total duct length.
Refer to the illustrations below for ducting
considerations for cooktop wall and island
hoods. Consult a qualified HVAC engineer for
specific installation and ducting applications.
C O O K T O P C H I M N E Y W A L L H O O D SC O O K T O P C H I M N E Y I S L A N D H O O D
20
W O L F C O O K T O P V E N T I L A T I O N
DUCTWORK
INSTALLATION
THROUGH
ROOF
D
UCTWORK
INSTALLATION
THROUGH
WALL
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
291/8" (740)
TO
411/2" (1054)
OVERALL
HEIGHT
173/4"
(451)
DEPTH OF HOOD
DUCTWORK
I
NSTALLATION
THROUGH
ROOF
DUCTWORK
INSTALLATION
THROUGH EAVE –
INTERNAL
BLOWER ONLY
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
281/4" (718)
TO
411/2" (1054)
OVERALL
HEIGHT
215/8" (549)
DEPTH OF HOOD
C O O K T O P L O W - P R O F I L E H O O D S
ucting Considerations
D
IMPORTANT NOTE: Except in recirculating
installations, cooktop low-profile hoods must be
vented to the outside. Use only metal ductwork.
Wolf cooktop low-profile hoods have a 6" (152)
round vertical discharge. Ducting can run
through the roof, external wall or eave. Ducting
through an eave requires an internal blower.
Refer to the illustrations below.
Ventilation hoods will operate most efficiently
when ductwork does not exceed 50' (15 m) in
length. Refer to the chart on page 52 to calculate
total duct length.
Local building codes may require the use of
make-up air. Consult your local HVAC professional for specific requirements in your area.
Refer to the Cooktop Ventilation chart on page
55 for blower options.
Refer to the illustrations below for ducting
considerations for cooktop low-profile wall and
island hoods. Consult a qualified HVAC engineer
for specific installation and ducting applications.
C O O K T O P L O W - P R O F I L E W A L L H O O D SC O O K T O P L O W - P R O F I L E I S L A N D H O O D
21
A C C E S S O R I E S
Optional acc essories
are ava ilable
through your Wolf
dealer. To obta in
loca l dealer
informati on, visit
the S howroom
Locator s ection of
our websi te,
wolfappliance.co m.
W O L F C O O K T O P V E N T I L A T I O N
A C C E S S O R I E S
O O K T O P W A L L A N D I S L A N D H O O D S
C
Flue Extension for 10' (3 m) Ceiling Height
DescriptionNumberModels
Flue Extension801635CTWH30 / CTWH36
Flue Extension801639IH4227
Classic Stainless Steel Wall Shields
DescriptionNumberModels
30" (762) x 30" (762) Wall Shield801633CTWH30 / CTEWH30I
36" (914) x 30" (762) Wall Shield801634CTWH36 / CTEWH36(I)
Recirculating Kit
DescriptionNumberModels
Recirculating Kit with Charcoal Filter812446CTEWH30I / CTEWH36I
Recirculating Kit with Charcoal Filter812447CTEIH42I
C
TEWH45I
Transitions
DescriptionNumberModels
8" (203) to 10" (254) Round804708CTWH30 / CTWH36 / IH4227
Dimensions i n
parenthe ses are i n
millimeters unless
otherwise sp ecified.
22
W O L F C O O K T O P V E N T I L A T I O N
D O W N D R A F T V E N T I L A T I O N S Y S T E M S
Wolf downdraft ventilation systems are available
in 30" (762), 36" (914) and 45" (1143) widths.
The downdraft should be at least as wide as the
cooking surface. Classic, platinum and carbon
stainless steel finishes are available on the
control module and top cover for Models DD30
and DD36. Model DD45 is available in the classic
stainless steel finish only.
Wolf downdraft systems are recommended for
use with Wolf framed induction, electric and gas
cooktops and some integrated modules.
A downdraft can be used with sealed burner
rangetop Models SRT304 and SRT366. An
accessory trim kit (810215) is required for this
installation. Contact your dealer for details.
IMPORTANT NOTE: Wolf downdraft ventilation
systems cannot be used with unframed induction and electric cooktops and steamer and fryer
modules. They are not recommended for use
with the electric grill module.
Downdraft Models DD30I, DD36I and DD45I
include a 500 CFM internal blower. Internal, inline and remote blowers are available for Models
DD30R, DD36R and DD45R.
IMPORTANT NOTE: Install these downdrafts
only with a Wolf blower.
Refer to the Cooktop Ventilation chart on page
55 for blower options for each downdraft.
owndraft Features
D
Remote-Mounted Control Module. Control
module with LED indicator lights can be
mounted in any location within 10' (3 m) of the
downdraft.
Three-Speed Blower Control. Low, medium and
high blower-speed control.
Filter Clean Timer. Timer lets you know when
the filter needs cleaning. The filter LED will
illuminate after approximately 30 hours of
operation.
Delay-Off Feature. This feature will allow the
blower to continue running at the selected speed
for five minutes. The chimney will remain up.
UL Listed. Listed to US and Canadian safety
standards.
Mode l DD30
Mode l DD36
Mode l DD45
Control Module
IMPORTANT NOTE: This appliance must be
used with a Wolf-approved control module and
top cover.
The downdraft control kit (includes control
module, top cover, mounting brackets, RJ45
connector and mounting hardware) is available
as a sales accessory for Models DD30 and DD36
and is included with Model DD45. Installation of
the remote-mounted control module must be
within 10' (3 m) of the downdraft assembly and
a minimum of 3" (76) from the outer edge of
cooktop cut-out.
M O D E L O P T I O N S
Downdraft w ith 500 CFM
Internal Blower
30" (762) Wi dthDD30I
36" (914) Wi dthDD36I
45" (1143) W idthDD45I
Downdraft O nly
30" (762) Wi dthDD30R*
36" (914) Wi dthDD36R*
45" (1143) W idthDD45R*
*Require s in-line or remote blower.
23
W O L F C O O K T O P V E N T I L A T I O N
23/8"
(60)
30"
(762)
91/16"
(230)
261/4"
(667)
11/2" (38)
DEPTH OF
DOWNDRAFT CHIMNEY
36"
(914)
321/4"
(819)
23/8"
(60)
91/16"
(230)
11/2" (38)
DEPTH OF
DOWNDRAFT CHIMNEY
Dimensions i n
parenthe ses are i n
millimeters unless
otherwise sp ecified.
24
Model DD30I / DD30R
3 0 " ( 7 6 2 ) D O W N D R A F T S Y S T E M
Model DD30I / DD30R
Installation TypeDowndraft
rim FinishesClassic Stainless Steel
T
Platinum Stainless Steel
Carbon Stainless Steel
Overall Width30" (762)
Overall Height9
1
/16" (230) above
countertop
Overall Depth23/8" (60)
Blower (DD30 I)
500 CFM Internal blower included
Blower Options (DD30 R)
1100 CFM In-Line
900, 1200 or 1500 CFM Remote
Duct Size
DD30I3
1
/4" (83) x 10" (254)
DD30R31/4" (83) x 14" (356)
DischargeAdjustable
Electrical Supply110/120 V AC, 60 Hz
15 amp dedicated circuit
Power Cord21/2' (.8 m) 3-prong
Features
Remote-mounted control module
Three-speed blower control
Filter clean timer
Delay-Off feature
Heat Sentry feature
Dishwasher-safe, aluminum mesh filters
Accessories
Classic, platinum or carbon stainless steel
control module with trim kit
Bracket support for installation with modules
SRT/downdraft trim kit (810215)
Transitions for in-line and remote blowers
Shipping Weight75 lbs (34 kg)
Model DD36I / DD36R
3 6 " ( 9 1 4 ) D O W N D R A F T S Y S T E M
Model DD36I / DD36R
Installation TypeDowndraft
rim FinishesClassic Stainless Steel
T
Platinum Stainless Steel
Carbon Stainless Steel
Overall Width36" (914)
Overall Height9
1
/16" (230) above
countertop
Overall Depth23/8" (60)
Blower (DD36I)
500 CFM Internal blower included
Blower Options (DD36R)
1100 CFM In-Line
900, 1200 or 1500 CFM Remote
Duct Size
DD36I3
1
/4" (83) x 10" (254)
DD36R31/4" (83) x 14" (356)
DischargeAdjustable
Electrical Supply110/120 V AC, 60 Hz
15 amp dedicated circuit
Power Cord21/2' (.8 m) 3-prong
Features
Remote-mounted control module
Three-speed blower control
Filter clean timer
Delay-Off feature
Heat Sentry feature
Dishwasher-safe, aluminum mesh filters
Accessories
Classic, platinum or carbon stainless steel
control module with trim kit
SRT/downdraft trim kit (810215)
Transitions for in-line and remote blowers
Shipping Weight80 lbs (36 kg)
Loading...