Wolf Pro Wall Hood Guide

V E N T I L A T I O N G U I D E
C O O K T O P H O O D S
D O W N D R A F T S Y S T E M S
|
P R O H O O D S
|
H O O D L I N E R S
|
C O N T E N T S
W
olf Cooktop Ventilation 6
W
ooktop Chimney Hoods 6
C
Cooktop Low-Profile Hoods 12
Downdraft Ventilation Systems 23
Wolf Pro Ventilation 30
Pro Low-Profile Wall Hoods 32
Pro 24" (610) Wall Hoods 33
Pro 27" (686) Wall Hoods 34
Pro Wall Chimney Hoods 35
Pro Island Hoods 36
Pro Hood Liners 39
Recirculating Ventilation 42
Ventilation 101 51
Determine the Duct Run 51
Determine Minimum CFM 53
CFM Recommendations 53
Select a Blower 54
Blower Options 55
Blower Specifications 57
Blower Considerations 71
Warranty Information 76
Featu res and s pecifications indic ated herein an d on our web site are subject to ch ange at a ny time w ithout notice. Check our websit e, wolfappliance .com for th e most up-to -dat e sp ecificat ions.
I M P O R T A N T N O T E
As you foll ow these instructi ons, you will notice warning and caution sy mbols. This blocked information i s important for th e safe and efficient in stallat ion of Wolf eq uipment. There are two ty pes of potential ha zards th at may o ccur during installation.
®
WOLF
is a registered trademark of Wolf Appliance, Inc.
signals a situation w here m inor injury or product d amage may o ccur if you do not fo llow instructi ons.
states a hazard that may cause serious injury or death if preca utions are not followed.
Another footnot e we would li ke to iden tify is IMPORTANT NOTE: Thi s high lights i nformation that i s especially relevant to a problem-free i nstallation.
W O L F V E N T I L A T I O N
W O L F V E N T I L A T I O N
Ventilation is an integral part of any kitchen. Proper ventilation provides a cleaner, more enjoyable cooking environment by removing the cooking vapors and odors from the cooking area. From downdrafts to 66" (1676) wide wall hoods, Wolf has ventilation products to satisfy all of your customers’ needs and preferences. The chart on the following page gives ventilation recommendations for each product line.
Installation instructions shipped with each Wolf ventilation product provide detailed specifica­tions. These instructions can also be found on our website, wolfappliance.com. Work with a qualified installer or Wolf authorized service center technician to ensure that all local codes are followed. Consult a qualified HVAC engineer for specific installation and ducting applications.
The inform atio n and images in t his guide are the copyr ight property of Wolf Appliance, I nc., a n affiliate of Sub-Z ero, Inc. Ne ither this book nor any informati on or images contained herein m ay be copied or used in whole or in par t without th e express writt en permissi on of Wolf Applianc e, Inc., an affiliate of Sub -Zero, Inc.
©Wolf Applia nce, Inc. all rights reserved.
3
W O L F V E N T I L A T I O N
S E L E C T I N G A V E N T I L A T I O N S Y S T E M
ooktop or Pro Ventilation
C
Wolf ventilation systems are divided into two categories: Cooktop ventilation and Pro ventila­tion. Wolf cooktop wall and island hoods are recommended for use with Wolf induction, electric, gas and integrated cooktops and should be at least as wide as the cooking surface. Wolf downdraft ventilation systems are recommended for use with Wolf framed induction, electric and gas cooktops and some integrated modules. They cannot be installed with unframed induc­tion and electric cooktops and steamer and fryer modules. They are not recommended for use with the electric grill module. A Pro ventilation hood is recommended for use with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops.
A downdraft can be used with sealed burner rangetop Models SRT304 and SRT366. An accessory trim kit (810215) is required for this installation. Contact your dealer for details.
The chart below provides a quick reference of recommended ventilation equipment for specific Wolf cooking products.
pdraft or Downdraft
U
The choice between updraft ventilation and downdraft ventilation will depend on several factors, most notably the cooking appliance being used as well as the installation and instal­lation location. Updraft ventilation, or overhead hood, will normally be a more effective ventila­tion option. Cooking vapors naturally rise, making it easier to collect and remove them from the cooking area.
Wolf downdrafts provide another effective option for ventilation. The 9" (229) telescope rises up from the countertop and draws cooking vapors away from the cooking surface. Down­draft ventilation is a great option in installations where updraft ventilation is either not wanted or is not a viable option.
COOKTOP S A ND MODU LES
Framed Induction Cooktops
Unframed Induction Cooktops
Framed Electric Cooktops
Unframed Electric Cooktops
Gas Cooktops
Integrated Modules – CT15I/S and IM15/S IG15/S, IS15/S and IF15/S
RANGES AND RANGETOPS
Dual Fuel Ranges
Sealed Burner Rangetops – SRT304 and SRT366 All Other Models
Gas Ranges
Gas Rangetops
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
COOKTOP VENTILATION PRO VENTILATION
WALL HOODS ISLAND HOODS DOWNDRA FTS WALL H OOD S ISLAND H OOD S LINERS
4
W O L F V E N T I L A T I O N
S E L E C T I N G A V E N T I L A T I O N S Y S T E M
FM Recommendations
C
Ventilation performance is measured in Cubic Feet per Minute, or CFM. The higher the CFM, the greater the amount of air that is evacuated through the ventilation system. CFM recommen­dations are based on the cooking appliance output. Wolf recommends 1 CFM per 100 Btu/hr.
The chart on page 53 provides minimum CFM recommendations for all Wolf cooking products.
Internal, In-Line or Remote Blower
A ventilation system must include a blower assembly. Most Wolf ventilation hoods and downdrafts are sold as a shell only. There are a few exceptions where internal blowers are included. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance requirements and homeowner preferences.
The charts on pages 55–56 provide blower options for all Cooktop and Pro ventilation products.
Internal blowers are mounted inside the hood canopy or downdraft blower box. In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers are mounted on the roof, or in some cases, an exterior wall. Remote mounted blowers will minimize the amount of blower noise, but will not eliminate the noise completely.
Some blower noise is considered normal while the blower is operational. If noise is a concern, a remote blower is recommended. To reduce noise further for remote blower applications, an atten­uator may be necessary. Consult a qualified HVAC engineer for specific installation and ducting applications.
idth Guidelines
W
The minimum hood width recommended for wall installations should be equal to the width of the cooktop or range. If the space is not restricted, a wider hood should be used to increase the capture area.
Island installations require a greater capture area. It is recommended that Wolf island hoods overlap the width of the cooktop or range by a minimum of 3" (76) on either side.
The width of the Wolf downdraft system should match the width of the cooktop.
Ceiling Height
When selecting a Wolf ventilation hood, make sure there is enough ceiling height to accommo­date the hood. This can be determined by adding the floor-to-countertop height plus the recom­mended spacing between the countertop and the bottom of the hood plus the height of the hood. Overall dimensions for all Wolf ventilation products are provided in this guide.
Installation of cooktop wall and island hoods should be 24" (610) to 30" (762) from the bottom of the hood to the countertop. For additional ceiling height guidelines for these chimney-style hoods, refer to pages 19–20.
Installation of Pro wall, wall chimney and island hoods and hood liners should be 30" (762) to 36" (914) from the bottom of the hood to the countertop.
Recirculating Ventilation
Recirculating ventilation units are installed on top of a ventilation hood; no ductwork is required. Recirculating units recycle the air through a charcoal filter and return it to the kitchen. Wolf recirculating units are for use with cooktop low-profile hoods with an internal blower and Pro wall hood Models PW302210, PW362210, PW302418, PW362418, PW302718 and PW362718.
IMPORTANT NOTE: This type of ventilation will not remove heat, moisture or combustion gases from the air. It will also be less effective in reducing odors and smoke.
5
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P C H I M N E Y H O O D S
odel CTWH30
M
Mode l CTWH36
Mode l IH4227
W O L F W A R R A N T Y
Wolf produc ts are covered by a two and five year resident ial warrant y (exclusions apply) . See warranty details at the end of th is guide.
Wolf cooktop chimney wall hoods are 21" (533) deep and come in 30" (762) and 36" (914) widths. The cooktop chimney island hood is 42" (1067) wide and 27" (686) deep. The hoods are seamless stainless steel in the classic finish.
Wolf cooktop chimney wall and island hoods are recommended for use with Wolf induction, electric and gas cooktops as well as with inte­grated modules and should be at least as wide as the cooking surface. A Pro ventilation hood is recommended for use with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops. Refer to page 30 for Pro ventila­tion specifications.
Cooktop chimney wall and island hoods come with a telescopic chimney flue extension which allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue exten­sion to accommodate 10' (3 m) ceilings is avail­able as a sales accessory.
Installation of cooktop chimney wall and island hoods should be 24" (610) to 30" (762) from the bottom of the hood to the countertop.
Wolf cooktop chimney hoods are shipped without the blower assembly. Internal, in-line or remote blower assemblies are available as a sales accessory.
IMPORTANT NOTE: Install these ventilation hoods only with a Wolf blower.
Refer to the Cooktop Ventilation chart on page 55 for blower options for each cooktop hood.
ooktop Chimney Hood Features
C
Front-Mounted Controls. Easy-access controls
with LED indicator lights.
Three-Speed Blower Control. Low, medium and high blower speed control.
Filter Clean Timer. Timer lets you know when the filter needs cleaning. The filter LED will illuminate after approximately 30 hours of operation.
Heat Sentry Feature. This feature automatically turns the unit on when heat is sensed and adjusts blower speed. The Heat Sentry feature is always in wait and is activated when exhaust temperature from hood reaches 200˚F (95˚C). At this temperature, blower motor speed will automatically adjust to the next highest speed.
Delay-Off Feature. This feature will allow the blower to continue running at the selected speed for a short time after you have left the cooking area. If the blower is on high speed and the Delay-Off feature is activated, the blower will continue to run at high speed for five minutes. Then it will go to low speed for five minutes before the blower is turned off.
Telescopic Chimney. Chimney flue extension fits 8' (2.4 m) to 9' (2.7 m) ceilings. A flue extension to accommodate 10' (3 m) ceilings is available.
Halogen Lighting. Sealed lighting with three settings.
Aluminum Mesh Filters. Dishwasher-safe stain­less steel clad, aluminum mesh filters.
UL Listed. Listed to US and Canadian safety standards.
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
6
M O D E L O P T I O N S
Cooktop Chimney Wall Ho ods
30" ( 762) Width CTWH30 36" ( 914) Width CTWH36
Cooktop Chimney Island Hood
42" ( 1067) Width IH42 27
W O L F C O O K T O P V E N T I L A T I O N
67/8"
(175)
3
0
1
/2" TO 4
8
1
/2"
(775 – 1232)
OVERALL HEIGHT
1
9
1
/8"
(
486)
30" (762)
OVERALL WIDTH
41/2"min
(
114)
1
8"
(457)
1
2"
(305)
21" (533)
OVERALL DEPTH
19/16"
(
40)
6
"
(152)
Model CTWH30
C O O K T O P C H I M N E Y W A L L H O O D
Model CTWH30
Installation Type Chimney Wall Hood
Finish Classic Stainless Steel
Overall Width 30" (762)
Overall Height 30
1
/2" (775) minimum to
481/2" (1232) full extension
Overall Depth 21" (533)
Blower Options
450 CFM Internal 600 or 1100 CFM In-Line 600, 900, 1200 or 1500 CFM Remote
Installation Height 24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size 8" (203) round
Discharge Vertical
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen Bulbs Two T4, 12 V, 20 W bulbs
included
Shipping Weight (shell only) 85 lbs (39 kg)
Features
Heavy-duty, seamless stainless steel Telescopic chimney flue extension Front-mounted controls with LED indicator Three-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters Sealed halogen lighting with three settings
Accessories
Flue extension to accommodate 10' (3 m) ceilings 30" (762) x 30" (762) wall shield 8" (203) to 10" (254) round transition for remote blower
Mode l CTWH30
M O D E L C T W H 3 0
Wall ho od comes complete wit h filters, halogen bulbs, transitio n and backdraft dam per. Internal, in -line and remote bl owers , as well as op tional accessories , are available throug h your Wolf dealer.
Refer to page 22 for ad ditiona l informati on on accessories .
7
191/8"
(
486)
45/16"m
in
(110)
3211/16" TO507/8"
(
830 – 1292)
O
VERALL HEIGHT
357/16" (
900)
O
VERALL WIDTH
18"
(457)
12"
(305)
21" (533)
OVERALL DEPTH
91/4"
(235)
19/16"
(40)
811/16"
(221)
Model CTWH36
W O L F C O O K T O P V E N T I L A T I O N
Model CTWH36
M O D E L C T W H 3 6
Wall ho od comes complete wit h filters, halogen bulbs, transitio n and backdraft dam per. Internal, in -line and remote bl owers , as well as op tional acce ssories , are available throug h your Wolf dealer.
Refer to page 22 for ad ditiona l informati on on acce ssories .
C O O K T O P C H I M N E Y W A L L H O O D
Model CTWH36
Installation Type Chimney Wall Hood
Finish Classic Stainless Steel
Overall Width 357/16" (900)
Overall Height 32
11
/16" (830) minimum to
507/8" (1292) full extension
Overall Depth 21" (533)
Blower Options
600 or 900 CFM Internal 600 or 1100 CFM In-Line 600, 900, 1200 or 1500 CFM Remote
Installation Height 24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size 8" (203) round
Discharge Vertical
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen Bulbs Three T4, 12 V, 20 W bulbs
included
Shipping Weight (shell only) 100 lbs (45 kg)
Features
Heavy-duty, seamless stainless steel Telescopic chimney flue extension Front-mounted controls with LED indicator Three-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters Sealed halogen lighting with three settings
Accessories
Flue extension to accommodate 10' (3 m) ceilings 36" (914) x 30" (762) wall shield 8" (203) to 10" (254) round transition for remote blower
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
8
W O L F C O O K T O P V E N T I L A T I O N
339/16" TO 471/16"
(853 – 1195)
O
VERALL HEIGHT
42" (1067)
OVERALL WIDTH
18"
(
457)
12"
(
305)
27" (686)
OVERALL DEPTH
195/16"
(491)
5
"
m
in
(127)
91/4"
(
235)
19/16"
(40)
Model IH4227
Mode l IH4227
C O O K T O P C H I M N E Y I S L A N D H O O D
Model IH4227
Installation Type Chimney Island Hood
Finish Classic Stainless Steel
Overall Width 42" (1067)
Overall Height 33
9
/16" (853) minimum to
6
471/
1
"(1195) full extension
Overall Depth 27" (686)
Blower Options
600 or 900 CFM Internal 600 or 1100 CFM In-Line 600, 900, 1200 or 1500 CFM Remote
Installation Height 24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size 8" (203) round
Discharge Vertical
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen Bulbs Four T4, 12 V, 20 W bulbs
included
Shipping Weight (shell only) 110 lbs (50 kg)
Features
Heavy-duty, seamless stainless steel Telescopic chimney flue extension Front-mounted controls with LED indicator Three-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters Sealed halogen lighting with three settings
Accessories
Flue extension to accommodate 10' (3 m) ceilings 8" (203) to 10" (254) round transition for remote blower
M O D E L I H 4 2 2 7
Island hood comes complete wit h filters, halogen bulbs, transitio n and backdraft dam per. Internal, in -line and remote bl owers , as well as op tional accessories , are available throug h your Wolf dealer.
Refer to page 22 for ad ditiona l informati on on accessories .
9
W O L F C O O K T O P V E N T I L A T I O N
8' TO 9'
(2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
24" TO 30"*
(610 – 762)
TO
COUNTERTOP
21"
(533)
E
4" (102)
6"
(152)
30" OR 357/16"
(762 or 900)
481/2" OR 507/8"
(1232 or 1292)
MAXIMUM
HEIGHT OF HOOD
301/2" OR 3211/16"
(775 or 830)
MINIMUM
HEIGHT OF HOOD
*8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of 29
1
/2" (749) for Model CTWH30 and 275/16" (694) for Model CTWH36.
LOCATION OF
ELECTRICAL
C O O K T O P C H I M N E Y H O O D S
I N S T A L L A T I O N
Refer to the insta lla­tion instructi ons shipped with ea ch Wolf ventil ation product fo r detailed specificatio ns. These i nstructions can a lso be found on ou r web site, wolfappliance.co m.
lectrical Requirements
E
Wolf cooktop chimney wall and island hoods require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electri­cal supply is not critical as long as you provide a minimum of 12" (305) of 120 V AC power cable for the wall hood and 6' (1.8 m) for the island hood.
Locate electrical within the shaded area shown in the installation illustration for your model below and on the following page.
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
lower Considerations
B
Wolf cooktop chimney wall and island hoods are shipped without the blower assembly. Internal, in-line and remote blower assemblies are avail­able. For wall hoods, the remote blower can be mounted on the roof or an exterior wall. For island hoods, the remote blower will be mounted on the roof.
The blower will vary in size, which is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run.
A remote-mounted blower will minimize the amount of blower noise but will not eliminate the noise completely. All remote blowers will require a transition to a 10" (254) duct.
IMPORTANT NOTE: Install these ventilation hoods only with a Wolf blower.
Refer to the Cooktop Ventilation chart on page 55 for blower options.
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
C O O K T O P W A L L H O O D I N S T A L L A T I O N
10
4
2"
(1067)
4
7
1
/16" (1195)
MAXIMUM
HEIGHT OF HOOD
3
3
9
/16" (853)
MINIMUM
HEIGHT OF HOOD
27" (686)
LOCATION OF ELECTRICAL
ON CEILING THROUGH
TOP OF HOOD
8'
TO 9
'
(
2.4 m – 2.7 m) FLOOR TO
CEILING HEIGHT
2
4"
TO 3
0"*
(
610 – 762)
TO
COUNTERTOP
*8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of 26
7
/16" (672).
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P I S L A N D H O O D I N S T A L L A T I O N
I N S T A L L A T I O N
Refer to the insta lla­tion instructi ons shipped with ea ch Wolf ventil ation product fo r detailed specificatio ns. These i nstructions can a lso be found on ou r web site, wolfappliance.co m.
11
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P L O W - P R O F I L E H O O D S
Mode l CTEWH3 0I
Mode l CTEWH3 6(I)
Mode l CTEWH4 5(I)
Mode l CTEIH4 2I
Wolf cooktop low-profile wall hoods are 173/4" (451) deep and come in 30" (762), 36" (914) and 45" (1143) widths. The cooktop low-profile island hood is 42" (1067) wide and 215/8" (549) deep. The hoods are classic stainless steel with a black glass front panel. Wall and island hoods are available with an internal blower or some wall hood models have in-line and remote blower options.
Wolf cooktop low-profile wall and island hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. For Wolf ranges and rangetops, a Pro ventilation hood is recommended.
Cooktop low-profile wall and island hoods come with a telescopic chimney flue extension which allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look.
Refer to the Cooktop Ventilation chart on page 55 for blower options for each cooktop hood.
ooktop Low-Profile Hood Features
C
Stainless steel construction with classic finish
500 CFM internal blower included with (I)
models—in-line or remote blower options for Models CTEWH36 and CTEWH45
Front-mounted controls
Four-speed blower control
Filter clean indicator lets you know when grease
filter needs cleaning
Delay-off mode automatically turns unit off
Sealed halogen lighting with three settings
Stainless steel filter cover with dishwasher-safe
stainless steel clad aluminum mesh grease filter(s)
Heat Sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed
Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings
Internal blower (I) models can be used in a non­ducted application using an accessory charcoal recirculating filter
Transition with backdraft damper included
UL listed to US and Canadian safety standards
W O L F W A R R A N T Y
Wolf produc ts are covered by a two and five year resident ial warrant y (exclusions apply) . See warranty details at the end of th is guide.
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
12
M O D E L O P T I O N S
Cooktop Low-Profile Wal l Ho ods
30" ( 762) Width CTEWH30I 36" ( 914) Width CTEWH36I
CTEWH36
45" ( 1143) Width CTEWH45I
CTEWH45
Cooktop Low-Profile Island H ood
42" ( 1067) Width CTEIH42I
W O L F C O O K T O P V E N T I L A T I O N
201/8"
(511)
31/8" (79)
57/8" (149)
TO
183/8" (467)
107/8"
(276)
97/8"
(251)
2
9
1
/8" (
740)
TO
411/2" (1054)
O
VERALL
HEIGHT
30" (762)
OVERALL WIDTH
173/4"
(451)
OVERALL DEPTH
Model CTEWH30I
Mode l CTEWH3 0I
C O O K T O P L O W - P R O F I L E W A L L H O O D
Model CTEWH30I
Installation Type Low-Profile Wall Hood
Finish Classic Stainless Steel
Overall Width 30" (762)
Overall Height 29
1
/8" (740) minimum to
411/2" (1054) full extension
Overall Depth 173/4" (451)
Internal Blower 500 CFM included
Installation Height 24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size 6" (152) round
Discharge Vertical
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen Bulbs Four T4, 12 V, 20 W bulbs
included
Shipping Weight 53 lbs (24 kg)
Features
Heavy-duty classic stainless steel Telescopic chimney flue extension Front-mounted controls Four-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters Sealed halogen lighting with three settings
Accessories
30" (762) x 30" (762) wall shield Recirculating kit with charcoal filter
C T E W H 3 0 I
Wall ho od includes a 500 C FM internal blower and c omes complete wit h filters, halogen bulbs, transitio n and backdraft dam per.
Refer to page 22 for in formation on accessories avail­able through you r Wolf de aler.
13
201/8"
(511)
31/8" (79)
57/8" (149)
TO
183/8" (467)
107/8"
(276)
97/8"
(251)
291/8" (
740)
TO
411/2" (1054)
O
VERALL
HEIGHT
36" (914)
OVERALL WIDTH
173/4"
(451)
OVERALL DEPTH
Model CTEWH3 6(I)
W O L F C O O K T O P V E N T I L A T I O N
Model CTEWH36(I)
C T E W H 3 6 ( I )
Model CTEWH3 6I includes a 500 CF M internal blower. Internal, in -line and remote bl owers are available for Model CTEWH36. Bot h wall hoods c ome complete wit h filters, halogen bulbs, transitio n and backdraft dam per.
Refer to page 22 for in formation on acce ssories avail­able through you r Wolf de aler.
C O O K T O P L O W - P R O F I L E W A L L H O O D
Model CTEWH36(I)
Installation Type Low-Profile Wall Hood
Finish Classic Stainless Steel
Overall Width 36" (914)
Overall Height 29
1
/8" (740) minimum to
411/2" (1054) full extension
Overall Depth 173/4" (451)
CTEWH36I Blower 500 CFM Internal
CTEWH36 Blower Options
600 or 1100 CFM In-Line 600, 900, 1200 or 1500 CFM Remote
Installation Height 24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size 6" (152) round
Discharge Vertical
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen Bulbs Four T4, 12 V, 20 W bulbs
included
Shipping Weight
CTEWH36 (shell) 51 lbs (23 kg) CTEWH36I 57 lbs (26 kg)
Features
Heavy-duty classic stainless steel Telescopic chimney flue extension Front-mounted controls Four-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters Sealed halogen lighting with three settings
Accessories
36" (914) x 30" (762) wall shield Recirculating kit with charcoal filter (CTEWH36I only)
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
14
W O L F C O O K T O P V E N T I L A T I O N
201/8"
(511)
31/8" (79)
57/8" (
149)
TO
183/8" (467)
1
0
7
/8"
(276)
97/8"
(251)
291/8" (740)
TO
411/2" (1054)
OVERALL
HEIGHT
45" (1143)
OVERALL WIDTH
173/4"
(451)
OVERALL DEPTH
Model CTEWH45(I)
Mode l CTEWH4 5(I)
C O O K T O P L O W - P R O F I L E W A L L H O O D
Model CTEWH45(I)
Installation Type Low-Profile Wall Hood
Finish Classic Stainless Steel
Overall Width 45" (1143)
Overall Height 29
1
/8" (740) minimum to
411/2" (1054) full extension
Overall Depth 173/4" (451)
CTEWH45I Blower 500 CFM Internal
CTEWH45 Blower Options
600 or 1100 CFM In-Line 600, 900, 1200 or 1500 CFM Remote
Installation Height 24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size 6" (152) round
Discharge Vertical
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen Bulbs Four T4, 12 V, 20 W bulbs
included
Shipping Weight
CTEWH45 (shell) 55 lbs (25 kg) CTEWH45I 63 lbs (29 kg)
Features
Heavy-duty classic stainless steel Telescopic chimney flue extension Front-mounted controls Four-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters Sealed halogen lighting with three settings
Accessories
Recirculating kit with charcoal filter (CTEWH45I only)
C T E W H 4 5 ( I )
Mode l CTEWH4 5I includes a 500 CF M internal blower. Internal, in -line and remote bl owers are available for Model CTEWH45. Bot h wall hoods c ome complete wit h filters, halogen bulbs, transitio n and backdraft dam per.
Refer to page 22 for in formation on accessories avail­able through you r Wolf de aler.
15
227/8"
(581)
31/8" (79)
21/8" (54)
TO
151/2" (394)
107/8"
(276)
121/8"
(308)
2
8
1
/4" (
718)
TO
411/2" (1054)
O
VERALL
HEIGHT
42" (1067)
OVERALL WIDTH
215/8" (549)
OVERALL DEPTH
Model CTEIH4 2I
W O L F C O O K T O P V E N T I L A T I O N
Model CTEIH42I
C T E I H 4 2 I
Island hood includes a 5 00 CFM inter nal blower and c omes complete wit h filters, halogen bulbs, transitio n and backdraft dam per.
Refer to page 22 for ad ditiona l informati on on acce ssories .
C O O K T O P L O W - P R O F I L E I S L A N D H O O D
Model CTEIH42I
Installation Type Low-Profile Island Hood
Finish Classic Stainless Steel
Overall Width 42" (1067)
Overall Height 28
1
/4" (718) minimum to
411/2" (1054) full extension
Overall Depth 215/8" (549)
Internal Blower 500 CFM included
Installation Height 24"– 30" (610 – 762) bottom
of hood to countertop
Duct Size 6" (152) round
Discharge Vertical
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Halogen Bulbs Four T4, 12 V, 20 W bulbs
included
Shipping Weight 92 lbs (42 kg)
Features
Heavy-duty classic stainless steel Telescopic chimney flue extension Front-mounted controls Four-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters Sealed halogen lighting with three settings
Accessories
Recirculating kit with charcoal filter
16
W O L F C O O K T O P V E N T I L A T I O N
8' TO 9'
(2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
24" TO 30"
(610 – 762)
TO
COUNTERTOP
173/4"
(451)
OVERALL DEPTH
E
15"
(381)
5"
(127)
30", 36" OR 45"
(762, 914 or 1143)
OVERALL WIDTH
291/8" (740)
TO
411/2" (1054)
OVERALL
HEIGHT
L
OCATION OF
ELECTRICAL WITHIN
SHADED AREA
C O O K T O P L O W - P R O F I L E H O O D S
lectrical Requirements
E
Wolf cooktop low-profile wall and island hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker.
Locate electrical within the shaded area shown in the installation illustration for your model below and on the following page.
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
lower Considerations
B
Wolf low-profile wall and island cooktop hoods are available with an internal blower. Wall hood Models CTEWH36 and CTEWH45 can be used with an in-line or remote blower assembly.
IMPORTANT NOTE: Install these ventilation hoods only with a Wolf blower.
The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. A straight, short duct run with a limited number of elbows and transitions will allow the ventilation hood to perform most efficiently.
A remote mounted blower will minimize the amount of blower noise, but will not eliminate the noise completely.
Refer to the Cooktop Ventilation chart on page 55 for blower options.
I N S T A L L A T I O N
Refer to the insta lla­tion instructi ons shipped with ea ch Wolf ventil ation product fo r detailed specificatio ns. These i nstructions can a lso be found on ou r web site, wolfappliance.co m.
L O W - P R O F I L E W A L L H O O D I N S T A L L A T I O N
17
8' TO9'
(2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
24" TO30"
(610 – 762)
TO
COUNTERTOP
42" (1067)
OVERALL WIDTH
281/4" (718)
TO
411/2" (1054)
OVERALL
HEIGHT
LOCATION OF
E
LECTRICAL
ON CEILING
THROUGH TOP
O
F HOOD
215/8" (549)
OVERALL DEPTH
I N S T A L L A T I O N
Refer to the insta lla­tion instructi ons shipped with ea ch Wolf ventil ation product fo r detailed specificatio ns. These i nstructions can a lso be found on ou r web site, wolfappliance.co m.
W O L F C O O K T O P V E N T I L A T I O N
L O W - P R O F I L E I S L A N D H O O D I N S T A L L A T I O N
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
18
W O L F C O O K T O P V E N T I L A T I O N
B
A C
D
MINIMUM
FLUE
EXTENSION
MINIMUM
FLUE
EXTENSION
B
A C
D
C O O K T O P V E N T I L A T I O N H O O D S
ood Placement
H
Wolf cooktop wall and island hoods come with a telescopic chimney flue extension that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available as a sales accessory for cooktop chimney hoods only.
Installation of the cooktop wall or island hood should be 24" (610) to 30" (762) from the bottom of the hood to the countertop.
To determine placement of the wall or island hood, you must calculate the height of the telescopic chimney flue. Refer to the chart for the minimum and maximum flue extension for your specific hood. Also refer to the illustrations.
IMPORTANT NOTE: Both sections of the telescopic chimney flue must be installed in order for the chimney to be lifted for service.
IMPORTANT NOTE: If the height of the upper flue section is less than
1
/2" (13), you will need to modify the flue to affix to the flue attachment brackets.
alculate Chimney Flue Height
C
1) First measure the total kitchen height from
finished floor to finished ceiling height (A). 8' (2.4 m) or 9' (2.7 m) ceilings are standard.
2) Next, measure the height from the finished floor to countertop (B). 36" (914) countertop height is standard.
3) Determine the desired distance from counter­top to bottom of hood (C). This dimension must be between 24" (610) and 30" (762).
IMPORTANT NOTE: 8' (2.4 m) ceilings may not permit installation of the wall or island hood at 30" (762) above the countertop.
4) To calculate the chimney flue height (D): D = A – (B + C). This dimension must be
between the minimum and maximum flue extension for your specific hood as shown in the chart.
C O O K T O P H O O D S
Flue Extension
Model Minimum Maximum
CTWH30
CTWH36
IH4227
CTEWH30I
CTEWH36(I)
CTEWH45(I)
CTEWH42I
301/2" (775) 481/2" (1232)
3211/16" (830) 507/8" (1292)
339/16" (853) 471/16" (1195)
291/8" (740) 411/2" (1054)
291/8" (740) 411/2" (1054)
291/8" (740) 411/2" (1054)
281/4" (718) 411/2" (1054)
Cooktop Chimney Hoods Cooktop Low-Profile Hoods
19
21" (535)
DEPTH OF HOOD
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
301/2" (775) TO
481/2" (1232)
OR
3211/16" (830) TO
507/8" (1292)
HEIGHT
OF HOOD
DUCTWORK
INSTALLATION
THROUGH
R
OOF
DUCTWORK
INSTALLATION
THROUGH
WALL
27" (686)
DEPTH OF HOOD
DUCTWORK
INSTALLATION
T
HROUGH
R
OOF
DUCTWORK
INSTALLATION
THROUGH EAVE –
INTERNAL
BLOWER ONLY
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
339/16" (853)
TO
471/16" (1195)
HEIGHT
OF HOOD
W O L F C O O K T O P V E N T I L A T I O N
C O O K T O P C H I M N E Y H O O D S
ucting Considerations
D
IMPORTANT NOTE: All Wolf cooktop hoods
must be vented to the outside. Use only metal ductwork.
Wolf cooktop wall and island hoods have an 8" (203) round vertical discharge. Ducting can run through the roof, external wall or eave. Ducting through an eave requires an internal blower. Refer to the illustrations below for ducting considerations.
A straight, short duct run with a limited number of elbows and transitions will allow the ventila­tion hood to perform most efficiently. Wolf cooktop wall and island hoods will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Refer to the chart on page 52 to calculate total duct length.
Refer to the illustrations below for ducting considerations for cooktop wall and island hoods. Consult a qualified HVAC engineer for specific installation and ducting applications.
C O O K T O P C H I M N E Y W A L L H O O D S C O O K T O P C H I M N E Y I S L A N D H O O D
20
W O L F C O O K T O P V E N T I L A T I O N
DUCTWORK
INSTALLATION
THROUGH
ROOF
D
UCTWORK
INSTALLATION
THROUGH
WALL
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
291/8" (740)
TO
411/2" (1054)
OVERALL
HEIGHT
173/4"
(451)
DEPTH OF HOOD
DUCTWORK
I
NSTALLATION
THROUGH
ROOF
DUCTWORK
INSTALLATION
THROUGH EAVE –
INTERNAL
BLOWER ONLY
24" (610)
TO
30" (762)
COUNTERTOP
TO BOTTO M
OF HOOD
281/4" (718)
TO
411/2" (1054)
OVERALL
HEIGHT
215/8" (549)
DEPTH OF HOOD
C O O K T O P L O W - P R O F I L E H O O D S
ucting Considerations
D
IMPORTANT NOTE: Except in recirculating
installations, cooktop low-profile hoods must be vented to the outside. Use only metal ductwork.
Wolf cooktop low-profile hoods have a 6" (152) round vertical discharge. Ducting can run through the roof, external wall or eave. Ducting through an eave requires an internal blower. Refer to the illustrations below.
Ventilation hoods will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Refer to the chart on page 52 to calculate total duct length.
Local building codes may require the use of make-up air. Consult your local HVAC profes­sional for specific requirements in your area.
Refer to the Cooktop Ventilation chart on page 55 for blower options.
Refer to the illustrations below for ducting considerations for cooktop low-profile wall and island hoods. Consult a qualified HVAC engineer for specific installation and ducting applications.
C O O K T O P L O W - P R O F I L E W A L L H O O D S C O O K T O P L O W - P R O F I L E I S L A N D H O O D
21
A C C E S S O R I E S
Optional acc essories are ava ilable through your Wolf dealer. To obta in loca l dealer informati on, visit the S howroom Locator s ection of our websi te, wolfappliance.co m.
W O L F C O O K T O P V E N T I L A T I O N
A C C E S S O R I E S
O O K T O P W A L L A N D I S L A N D H O O D S
C
Flue Extension for 10' (3 m) Ceiling Height
Description Number Models
Flue Extension 801635 CTWH30 / CTWH36
Flue Extension 801639 IH4227
Classic Stainless Steel Wall Shields
Description Number Models
30" (762) x 30" (762) Wall Shield 801633 CTWH30 / CTEWH30I
36" (914) x 30" (762) Wall Shield 801634 CTWH36 / CTEWH36(I)
Recirculating Kit
Description Number Models
Recirculating Kit with Charcoal Filter 812446 CTEWH30I / CTEWH36I
Recirculating Kit with Charcoal Filter 812447 CTEIH42I
C
TEWH45I
Transitions
Description Number Models
8" (203) to 10" (254) Round 804708 CTWH30 / CTWH36 / IH4227
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
22
W O L F C O O K T O P V E N T I L A T I O N
D O W N D R A F T V E N T I L A T I O N S Y S T E M S
Wolf downdraft ventilation systems are available in 30" (762), 36" (914) and 45" (1143) widths. The downdraft should be at least as wide as the cooking surface. Classic, platinum and carbon stainless steel finishes are available on the control module and top cover for Models DD30 and DD36. Model DD45 is available in the classic stainless steel finish only.
Wolf downdraft systems are recommended for use with Wolf framed induction, electric and gas cooktops and some integrated modules.
A downdraft can be used with sealed burner rangetop Models SRT304 and SRT366. An accessory trim kit (810215) is required for this installation. Contact your dealer for details.
IMPORTANT NOTE: Wolf downdraft ventilation systems cannot be used with unframed induc­tion and electric cooktops and steamer and fryer modules. They are not recommended for use with the electric grill module.
Downdraft Models DD30I, DD36I and DD45I include a 500 CFM internal blower. Internal, in­line and remote blowers are available for Models DD30R, DD36R and DD45R.
IMPORTANT NOTE: Install these downdrafts only with a Wolf blower.
Refer to the Cooktop Ventilation chart on page 55 for blower options for each downdraft.
owndraft Features
D
Remote-Mounted Control Module. Control
module with LED indicator lights can be mounted in any location within 10' (3 m) of the downdraft.
Three-Speed Blower Control. Low, medium and high blower-speed control.
Filter Clean Timer. Timer lets you know when the filter needs cleaning. The filter LED will illuminate after approximately 30 hours of operation.
Delay-Off Feature. This feature will allow the blower to continue running at the selected speed for five minutes. The chimney will remain up.
Aluminum Mesh Filters. Stainless steel filter covers with dishwasher-safe, aluminum mesh filters.
UL Listed. Listed to US and Canadian safety standards.
Mode l DD30
Mode l DD36
Mode l DD45
Control Module
IMPORTANT NOTE: This appliance must be
used with a Wolf-approved control module and top cover.
The downdraft control kit (includes control module, top cover, mounting brackets, RJ45 connector and mounting hardware) is available as a sales accessory for Models DD30 and DD36 and is included with Model DD45. Installation of the remote-mounted control module must be within 10' (3 m) of the downdraft assembly and a minimum of 3" (76) from the outer edge of cooktop cut-out.
M O D E L O P T I O N S
Downdraft w ith 500 CFM Internal Blower
30" (762) Wi dth DD30I 36" (914) Wi dth DD36I 45" (1143) W idth DD45I
Downdraft O nly
30" (762) Wi dth DD30R* 36" (914) Wi dth DD36R* 45" (1143) W idth DD45R*
*Require s in-line or remote blower.
23
W O L F C O O K T O P V E N T I L A T I O N
23/8"
(60)
30"
(762)
91/16"
(230)
261/4"
(667)
11/2" (38)
DEPTH OF
DOWNDRAFT CHIMNEY
36"
(914)
321/4"
(819)
23/8"
(60)
91/16"
(230)
11/2" (38)
DEPTH OF
DOWNDRAFT CHIMNEY
Dimensions i n parenthe ses are i n millimeters unless otherwise sp ecified.
24
Model DD30I / DD30R
3 0 " ( 7 6 2 ) D O W N D R A F T S Y S T E M
Model DD30I / DD30R
Installation Type Downdraft
rim Finishes Classic Stainless Steel
T
Platinum Stainless Steel Carbon Stainless Steel
Overall Width 30" (762)
Overall Height 9
1
/16" (230) above
countertop
Overall Depth 23/8" (60)
Blower (DD30 I)
500 CFM Internal blower included
Blower Options (DD30 R)
1100 CFM In-Line 900, 1200 or 1500 CFM Remote
Duct Size
DD30I 3
1
/4" (83) x 10" (254)
DD30R 31/4" (83) x 14" (356)
Discharge Adjustable
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Power Cord 21/2' (.8 m) 3-prong
Features
Remote-mounted control module Three-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters
Accessories
Classic, platinum or carbon stainless steel control module with trim kit Bracket support for installation with modules SRT/downdraft trim kit (810215) Transitions for in-line and remote blowers
Shipping Weight 75 lbs (34 kg)
Model DD36I / DD36R
3 6 " ( 9 1 4 ) D O W N D R A F T S Y S T E M
Model DD36I / DD36R
Installation Type Downdraft
rim Finishes Classic Stainless Steel
T
Platinum Stainless Steel Carbon Stainless Steel
Overall Width 36" (914)
Overall Height 9
1
/16" (230) above
countertop
Overall Depth 23/8" (60)
Blower (DD36I)
500 CFM Internal blower included
Blower Options (DD36R)
1100 CFM In-Line 900, 1200 or 1500 CFM Remote
Duct Size
DD36I 3
1
/4" (83) x 10" (254)
DD36R 31/4" (83) x 14" (356)
Discharge Adjustable
Electrical Supply 110/120 V AC, 60 Hz
15 amp dedicated circuit
Power Cord 21/2' (.8 m) 3-prong
Features
Remote-mounted control module Three-speed blower control Filter clean timer Delay-Off feature Heat Sentry feature Dishwasher-safe, aluminum mesh filters
Accessories
Classic, platinum or carbon stainless steel control module with trim kit SRT/downdraft trim kit (810215) Transitions for in-line and remote blowers
Shipping Weight 80 lbs (36 kg)
Loading...
+ 54 hidden pages