Wolf Pro Wall Hood Installation Guide

Page 1
I NSTALLATION I NSTRUCTIONS
P RO W ALL V ENTILATION H OODS
Page 2
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
WOLF®is a registered trademark of Wolf Appliance, Inc.
CONTACT INFORMATION
Wolf Customer Service: 800-332-9513
Website: wolfappliance.com
Page 3
3
WOLF PRO WALL VENTILATION HOODS
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be completed by a qualified installer or Wolf authorized service center technician.
Installer:
Please read the entire Installation Instructions prior to installation. Save these instructions for the local inspector’s refer­ence, then leave them with the homeowner.
Homeowner:
Please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
Any questions or problems about the installa­tion should be directed to your Wolf dealer or Wolf Appliance, Inc. at 800-332-9513. You can also visit our website at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the wall hood. Both numbers are listed on the rating plate, located inside the left wall of the hood shell. Refer to the illustration below.
A)
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B)
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
C)
Ducted fans must always be vented to the outdoors.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
RATING PLATE INFORMATION
Model Number
Serial Number
Rating plate location
Rating plate located
inside hood shell
To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
Page 4
4
WOLF PRO WALL VENTILATION HOODS
LIST OF MATERIALS
The following is a list of materials shipped with the Wolf Pro wall ventilation hood.
Stainless steel wall hood
Transition with backdraft damper— 24" (610) and 27" (686) deep hoods: attached inside hood (needs to be removed prior to installation)
Decorative stainless steel rail and installa­tion components—(R) model hoods only
Control knobs—two for low-profile and 24" (610) deep hoods, three for 27" (686) deep hoods
Filters (installed in hood)
Grease cups—24" (610) and 27" (686) deep hoods only (shipped loose in carton)
Halogen lamps for lighting—heat lamps for 27" (686) deep hoods are not included
Wood mounting support—24" (610) and 27" (686) deep hoods only
Installation package (part #810555) mounting hardware included:
(10) #8 x 3" (76) Phillips drywall screws, (12) #10 x 1
1
/2" (38) pan head wood screws, (12) #12 flat washers (4) #8 x 3" (76) Phillips sheet metal screws
Installation Instructions
Use & Care Information and product registration card
Wolf logo nameplate
Bottle of Signature stainless steel cleaner
INSTALLATION CONSIDERATIONS
Wolf Pro wall ventilation hoods are recommended for use with all Wolf cooking appliances.
IMPORTANT NOTE:
For optimal performance, a Pro 27" (686) deep wall hood is recom­mended for use with ranges and rangetops that contain a charbroiler or griddle.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Wolf Warranty. Refer to the Wolf Pro Ventilation Hoods Use & Care Information for warranty details, or visit our website, wolfappliance.com.
Make sure you have the tools and materials necessary for proper installation.
Warranty service must be performed by a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation.
IMPORTANT NOTE:
Wolf Pro ventilation hoods are shipped without the blower assembly. Wolf internal, in-line and remote blower assemblies are available, refer to page
24. Use only a Wolf blower with the Pro wall ventilation hood.
Low-Profile Wall Hood
Low-Profile Wall Hood (R) Rail Option
24" (610) Wall Hood
24" (610) Wall Hood (R) Rail Option
27" (686) Wall Hood
27" (686) Wall Hood (R) Rail Option
Page 5
5
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
RECIRCULATING KIT
If you are installing the accessory recirculating kit, refer to the instructions included with the kit before installing the hood. Accessory kits are available through your Wolf dealer.
HORIZONTAL DISCHARGE KIT
Pro low-profile wall hoods come standard from the factory with horizontal or vertical discharge. If a horizontal discharge is needed for installation of a 24" (610) or 27" (686) deep wall hood, an accessory horizontal discharge kit is required. Refer to the instructions included in the kit for complete mounting and blower options. Accessory kits are available through your Wolf dealer.
INSTALLATION CONSIDERATIONS
IMPORTANT NOTE:
Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop.
Rail option (R) wall hoods come with a classic stainless steel decorative rail and stand-offs. Optional platinum or brass rails are available to match Wolf dual fuel range bezels. Contact your Wolf dealer for details.
ELECTRICAL REQUIREMENTS
Wolf Pro wall ventilation hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply within the shaded area shown in the Installation Specifications illustration on page 7.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
DUCT COVER
If you are installing a Wolf duct cover with the Pro wall hood, refer to instructions on page 18 before installing the hood.
Page 6
Dimensions in parentheses are in millimeters unless otherwise specified.6
WOLF PRO WALL VENTILATION HOODS
10" (254)
OVERALL
HEIGHT
OVERALL WIDTH
4" (102)
22" (559)
OVERALL DEPTH
12"
(305)
2"
(51)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL WIDTH
4" (102)
24" (610)
OVERALL DEPTH
12"
(305)
18" (457)
OVERALL
HEIGHT
2"
(51)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL WIDTH
27" (686)
OVERALL DEPTH
12"
(305)
18" (457)
OVERALL
HEIGHT
2"
(51)
4" (102)
3
/4" (19)
DIAMETER
OF RAIL
OVERALL DIMENSIONS
LOW-PROFILE WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067) and 48" (1219)
Overall Height
10" (254)
Overall Depth (
excluding
rail) 22" (559)
Shipping Weight (shell only) 39–55 lbs
(18–25 kg)
Unit dimensions may vary to ±1/8" (3).
24" (610) DEEP WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067), 48" (1219), 54" (1372),
60" (1524) and 66" (1676)
Overall Height
18" (457)
Overall Depth (
excluding
rail) 24" (610)
Shipping Weight (shell only) 67–126 lbs
(30–57 kg)
Unit dimensions may vary to ±1/8" (3).
27" (686) DEEP WALL HOODS
Overall Widths 30" (762), 36" (914),
42" (1067), 48" (1219), 54" (1372),
60" (1524) and 66" (1676)
Overall Height
18" (457)
Overall Depth (
excluding
rail) 27" (686)
Shipping Weight (shell only) 92–163 lbs
(42–74 kg)
Unit dimensions may vary to ±1/8" (3).
Low-Profile Wall Hood
shown with (R) rail option
24" (610) Deep Wall Hood
shown with (R) rail option
27" (686) Deep Wall Hood
shown with (R) rail option
Page 7
7
INSTALLATION INSTRUCTIONS
E
6"
(152)
5"
(127)
LOCATION OF ELECTRICAL
30" TO 36"
(762–914)
TO COUNTERTOP
10" (254)
HEIGHT
OF HOOD
22" (559)
DEPTH OF HOOD
WIDTH OF HOOD
30" TO 36"
(762–914)
TO COUNTERTOP
NOTE: Pro low-profile wall hoods have an adjustable discharge.
30" TO 36"
(762–914)
TO COUNTERTOP
30" TO 36"
(762–914)
TO COUNTERTOP
18" (457)
HEIGHT
OF HOOD
24" (610) 27" (686)
DEPTH OF HOOD
WIDTH OF HOOD
NOTE: 24" (610) and 27" (686) deep wall hoods have a vertical discharge. A horizontal discharge kit is available as a sales accessory.
E
6"
(152)
5"
(127)
LOCATION OF ELECTRICAL
INSTALLATION SPECIFICATIONS
Low-Profile Wall Hoods
24" (610) and 27" (686) Deep Wall Hoods
Page 8
8
WOLF PRO WALL VENTILATION HOODS
TRANSITION SPECIFICATIONS
The illustrations and chart provide dimensions specific to Pro low-profile wall hood models with different transition applications. These dimensions are critical for proper installation.
Low-Profile Wall Hoods – 10" (254) Round Accessory Transition (for use with in-line or remote blower)
Model (A) (B) (C) (D)
PW302210(R) 30" (762) 9" (229) 143/4" (375) 55/8" (143)
PW362210(R) 36" (914) 9" (229) 173/4" (451) 55/8" (143)
PW422210(R) 42" (1067) 9" (229) 203/4" (527) 55/8" (143)
PW482210(R) 48" (1219) 9" (229) 233/4" (603) 55/8" (143)
Low-Profile Wall Hoods – 500 CFM Internal Blower (vertical discharge)
Model (A) (B) (C) (D)
PW302210(R) 30" (762) 11/2" (38) 143/4" (375) 25/8" (60)
PW362210(R) 36" (914) 11/2" (38) 173/4" (451) 25/8" (60)
PW422210(R) 42" (1067) 11/2" (38) 203/4" (527) 25/8" (60)
PW482210(R) 48" (1219) 11/2" (38) 233/4" (603) 25/8" (60)
Low-Profile Wall Hoods – 500 CFM Internal Blower (horizontal discharge)
Model (A) (B) (C) (D)
PW302210(R) 30" (762) 11/2" (38) 143/4" (375) 2" (51)
PW362210(R) 36" (914) 11/2" (38) 173/4" (451) 2" (51)
PW422210(R) 42" (1067) 11/2" (38) 203/4" (527) 2" (51)
PW482210(R) 48" (1219) 11/2" (38) 233/4" (603) 2" (51)
Letters correspond to those in the illustrations.
Low-Profile Wall Hoods – 10" (254) Round Accessory Transition
Low-Profile Wall Hoods – 500 CFM Internal Blower (vertical discharge)
Low-Profile Wall Hoods – 500 CFM Internal Blower (horizontal discharge)
IMPORTANT NOTE:
The transition included with the 500 CFM internal blower accommo­dates 3
1
/4" (83) x 10" (254) ductwork. An
optional 3
1
/4" (83) x 10" (254) to 8" (203) round transition is available as a sales accessory. Contact your Wolf dealer for details.
Low-Profile Wall Hoods –
No Transition
B
HEIGHT OF
TRANSITION
TO CENTER
OF TRANSITION
D
D
TO CENTER
OF TRANSITION
C
TO CENTER
OF TRANSITION
WIDTH
OF HOOD
B
HEIGHT OF
TRANSITION
A
C
TO CENTER
OF TRANSITION
A
WIDTH
OF HOOD
RECTANGULAR
CUT-OUT
14"
(356)
1
3
"
/4
(83)
D
TO CENTER
OF
TRANSITION
A
WIDTH
B
HEIGHT OF
TRANSITION
C
TO CENTER
OF TRANSITION
OF HOOD
Page 9
9
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
24" (610) and 27" (686) Deep Wall Hoods –
Transition Included
24" (610) Deep Wall Hoods
Model (A) (B) (C) (D)
PW302418(R) 30" (762) 9" (229) 143/4" (375) 55/8" (143)
PW362418(R) 36" (914) 9" (229) 173/4" (451) 55/8" (143)
PW422418(R) 42" (1067) 9" (229) 203/4" (527) 55/8" (143)
PW482418(R) 48" (1219) 9" (229) 233/4" (603) 55/8" (143)
PW542418(R) 54" (1372) 9" (229) 263/4" (679) 55/8" (143)
PW602418(R) 60" (1524) 9" (229) 293/4" (756) 55/8" (143)
PW662418(R) 66" (1676) 9" (229) 323/4" (832) 55/8" (143)
27" (686) Deep Wall Hoods
Model (A) (B) (C) (D)
PW302718(R) 30" (762) 9" (229) 143/4" (375) 55/8" (143)
PW362718(R) 36" (914) 9" (229) 173/4" (451) 55/8" (143)
PW422718(R) 42" (1067) 9" (229) 203/4" (527) 55/8" (143)
PW482718(R) 48" (1219) 9" (229) 233/4" (603) 55/8" (143)
PW542718(R) 54" (1372) 9" (229) 263/4" (679) 55/8" (143)
PW602718(R) 60" (1524) 9" (229) 293/4" (756) 55/8" (143)
PW662718(R) 66" (1676) 9" (229) 323/4" (832) 55/8" (143)
Letters correspond to those in the illustrations.
TRANSITION SPECIFICATIONS
The illustration and chart provide dimensions specific to Pro 24" (610) and 27" (686) deep wall hood models. These dimensions are critical for proper installation.
B
HEIGHT OF
TRANSITION
TO CENTER
OF TRANSITION
D
C
TO CENTER
OF TRANSITION
A
WIDTH
OF HOOD
Page 10
10
WOLF PRO WALL VENTILATION HOODS
DUCTWORK INSTALLATION
THROUGH ROOF
22" (559)
DEPTH OF HOOD
10" (254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE
17
3
/4"W x 41/4"D TO 10" ROUND
9
3
/8"H (INCLUDING FLANGES)
ACCESSORY TRANSITION
FOR IN-LINE OR
REMOTE BLOWER
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
10" (254)
HEIGHT OF HOOD
WALL HOOD
ROOF CAP OR REMOTE BLOWER
NOTE: 10" (254) ROUND ACCESSORY TRANSITION SHOWN IN VERTICAL DISCHARGE APPLICATION WITH IN-LINE OR REMOTE BLOWER. REFER TO INSTALLATION INSTRUCTIONS FOR HORIZONTAL DISHCARGE.
Ducting for low-profile wall hoods with in-line or remote blower
LOW-PROFILE WALL HOODS
STEP 1: INSTALL DUCTWORK
IMPORTANT NOTE:
Wolf recommends that the Pro low-profile wall hood be installed 30" (762) to 36" (914) above the countertop.
IMPORTANT NOTE:
Consult a qualified HVAC Engineer for specific ducting applications.
IMPORTANT NOTE:
All Pro low-profile wall hoods must exhaust to the outdoors except when used with the accessory recirculating kit (Models PW302210 and PW362210 only). Always use metal ducting. Do not use flex ducting.
Decide where the ductwork will run between the wall hood and the outside. A straight, short duct run will allow the hood to perform more efficiently. Limit the number of elbows and transitions to as few as possible. Long duct runs, elbows and transitions will reduce the performance of the hood. Wolf recommends the maximum linear duct run be no greater than 50' (15 m).
IMPORTANT NOTE:
There is a possibility of noise issues, if there is a short duct run coupled with a remote blower.
IMPORTANT NOTE:
Pro low-profile wall hoods come standard from the factory with horizontal or vertical discharge. When using an in-line or external blower, use either the optional accessory 10" (254) round transition (part #811194) or a custom piece. The rectan­gular cut-out on the hood is 3
1
/4" (83) x 14"
(356).
IMPORTANT NOTE:
Internal blower WBLOWER-50INT comes with a transition for use with 3
1
/4" (83) x 10" (254) ducting, attached
to the blower. A 3
1
/4" (83) x 10" (254) to 8" (203) round transition (part #804707) for use with WBLOWER-50INT is available as a sales accessory.
To reduce the risk of fire, use only metal ductwork.
Page 11
11
Dimensions in parentheses are in millimeters unless otherwise specified.
STEP 2: WALL PREPARATION
Construct the wall framing as shown in the illustration below. Be sure to locate horizon­tal framing using the desired installation height of the hood.
Refer to the illustrations below for the location of mounting holes for low-profile wall hoods.
LOW-PROFILE WALL HOODS
STEP 1: INSTALL DUCTWORK
Always install a roof or wall cap if you are not installing a remote blower. Connect 8" (203) or 10" (254) round metal ductwork to the cap and work back towards the hood. Use duct sealing tape on joints between ductwork sections.
Local codes may require the use of a backdraft damper. Contact your local HVAC professional for specific requirements. In cold weather installations, a backdraft damper is necessary to minimize the backflow of cold air into the room.
Local building codes may require the use of make-up air. Consult your local HVAC profes­sional for specific requirements in your area.
Framing must be tied together and to ceiling joists to provide enough structural strength to support the weight of the hood and internal blower, if applicable.
If wall framing is not available, wall anchors must be used.
Wall framing
To reduce the risk of fire and electric shock, install this ventilation hood only with a blower manufactured by Wolf. Blower model numbers are listed on page 24.
INSTALLATION INSTRUCTIONS
STEP 3: HOOD PREPARATION
IMPORTANT NOTE:
If an optional duct cover is to be used, follow the instructions on page 18 before installing the wall hood. If you are installing a recirculating kit, refer to instruc­tions included with the kit before installing the wall hood.
WIDTH OF HOOD
1
26
" (667) TO
/4
FRAMING STUD CENTERS
1
13
"
/8
(333)
1
8
"
/4
(210) TO
CENTER OF STUD
HOOD CENTERLINE
FRAMING
STUDS
Page 12
12
WOLF PRO WALL VENTILATION HOODS
LOW-PROFILE WALL HOODS
If you are using WBLOWER-50INT, refer to installation instructions provided with the blower and follow instructions for horizontal and vertical discharge. Install the blower in the hood before mounting the hood to the wall.
Remove the filters by pushing each filter up at the angle it is placed in, and rotate down. Remove the center filter first. Gloves should be worn to provide the proper grip when removing filters.
If you are using an inline or remote blower, attach the optional accessory 10" (254) round transition or custom piece to the top of the wall hood using holes provided.
If you are installing an in-line or remote blower, drill a
7
/8" (22) hole through the wood framing for the conduit. Refer to the in-line and remote blower information on pages 22–23 and follow installation instruc­tions provided with the blower.
IMPORTANT NOTE:
Do not run wiring for the
remote blower through the ductwork.
STEP 4: HOOD INSTALLATION
IMPORTANT NOTE:
If a backsplash is to be used, it should be installed before the wall hood is mounted. Refer to the instructions included with the kit for complete mounting instructions.
Install the wall mounting brackets as shown in the illustration below. Hang the wall hood on the installation brackets in preparation for attaching the hood to framing.
Position the hood in the desired location on the wall. Depending on the application, install the #10 x 1
1
/2" (38) screws with washers or 3" (76) drywall screws through the mounting holes on the back plate. Verify that the screws engage the wall studs or framing. If not, wall anchors must be used.
IMPORTANT NOTE:
If additional support is required for the wall hood, drill supplementary mounting holes in the back plate and use these holes to attach the hood assembly to the wall framing.
Due to the weight of the wall hood, be sure to have adequate manpower for installation.
WIDTH OF HOOD
26
1
/4
" (667) TO
MOUNTING BRACKET
HOLE CENTERS
13
1
/8
"
(333)
HOOD CENTERLINE
USE ROUND
AND SLOTTED
HOLES TO
SECURE HOOD
TO WALL
STUDS
MOUNT
BRACKETS TO
WALL FRAMING
7
7
/16
" (189)
TO TOP OF
BRACKET
Hood installation—vertical discharge
WIDTH OF HOOD
26
1
/4
" (667) TO
MOUNTING BRACKET
HOLE CENTERS
22
1
/2
" (572)
CENTERED ON HOOD
9
1
/2
" (229)
CENTERED
ON HOOD
13
1
/8
"
(333)
HOOD CENTERLINE
USE ROUND
AND SLOTTED
HOLES TO
SECURE HOOD
TO WALL
STUDS
MOUNT
BRACKETS TO
WALL FRAMING
7
7
/16
" (189)
TO TOP OF
BRACKET
WALL HOLE
CUT-OUT
Hood installation—horizontal discharge
Page 13
13
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
24" (610) AND 27" (686) WALL HOODS
STEP 1: INSTALL DUCTWORK
IMPORTANT NOTE:
Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop.
IMPORTANT NOTE:
Consult a qualified HVAC Engineer for specific ducting applications.
IMPORTANT NOTE:
All Pro 24" (610) and 27" (686) deep wall hoods must exhaust to the outdoors except when used with the accessory recirculating kit (Models PW302418 and PW362418 only). Always use metal ducting. Do not use flex ducting.
Decide where the ductwork will run between the wall hood and the outside. A straight, short duct run will allow the hood to perform more efficiently. Limit the number of elbows and transitions to as few as possible. Long duct runs, elbows and transitions will reduce the performance of the hood. Wolf recommends the maximum linear duct run be no greater than 50' (15 m).
IMPORTANT NOTE:
There is a possibility of noise issues, if there is a short duct run coupled with a remote blower.
IMPORTANT NOTE:
If a horizontal discharge is needed for installation of a 24" (610) or 27" (686) deep wall hood, an accessory horizontal discharge kit is required. Refer to instructions included with the kit for complete mounting and blower options. Accessory kits are avail­able through your Wolf dealer.
DUCTWORK INSTALLATION
THROUGH ROOF
24" (610)
DEPTH OF HOOD
ROOF CAP OR REMOTE BLOWER
10" (254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.
VERTICAL DISCHARGE
TRANSITION
22
1
/4"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
18" (457)
HEIGHT OF HOOD
WALL HOOD
Ducting for 24" (610) deep wall hoods
To reduce the risk of fire, use only metal ductwork.
Page 14
14
WOLF PRO WALL VENTILATION HOODS
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
18" (457)
HEIGHT OF HOOD
WALL HOOD
DUCTWORK INSTALLATION
THROUGH ROOF
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
27" (686)
DEPTH OF HOOD
10" (254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.
TRANSITION
22
1
/4"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
ROOF CAP OR REMOTE BLOWER
VERTICAL DISCHARGE
Ducting for 27" (686) deep wall hoods
24" (610) AND 27" (686) WALL HOODS
STEP 1: INSTALL DUCTWORK
Always install a roof or wall cap if you are not installing a remote blower. Connect 10" (254) round metal ductwork to the cap and work back towards the hood. Use duct sealing tape on joints between ductwork sections.
Wolf Pro 24" (610) and 27" (686) deep wall hoods come standard with a backdraft damper included in the transition assembly. Local codes may require the use of an additional backdraft damper. Contact your local HVAC professional for specific requirements. In cold weather installations, a backdraft damper is necessary to minimize the backflow of cold air into the room.
Local building codes may require the use of make-up air. Consult your local HVAC profes­sional for specific requirements in your area.
To reduce the risk of fire and electric shock, install this ventilation hood only with a blower manufactured by Wolf. Blower model numbers are listed on page 24.
Page 15
IMPORTANT NOTE:
The screws should be
countersunk so that they are below flush.
Install the flat metal hood retaining brackets to the wood mounting support at the loca­tions shown in the illustration and the chart below. Use the provided #10 X 1
1
/2" (38) screws and washers to secure these brackets in place. The metal bracket should be mounted
1
/2" (13) above the top of the
wood mounting support.
IMPORTANT NOTE:
The location of this wood mounting support and retaining bracket allow for
1
/2" (13) clearance at the top of the hood for ease of installation. This gap will be taken up during final mounting of the hood to the wood mounting support.
Refer to the illustration below for the location of mounting holes for the Pro 24" (610) and 27" (686) deep wall hoods.
15
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
If wall framing is not available, wall anchors must be used.
4
7
/16
"
(113)
2
1
/2
"
(64)
MOUNTING
HOLES
Location of mounting holes
24" (610) AND 27" (686) WALL HOODS
STEP 2: WALL PREPARATION
Construct the wood wall framing flush with the wall studs and centered in the location that the hood will be mounted. Finish the wall surface.
Attach the provided wood mounting support. Refer to the illustration and the chart below. The wood support should be centered within the desired hood location. Use the provided 3" (76) screws to attach the support to the wall. The location of these screws should correspond to the wood supports within the walls or the framing.
Framing must be tied together to provide enough structural strength to support the weight of the hood and internal blower, if applicable.
Wood mounting support
Wood Mounting Support
Hood Width (A) (B)
30" (762) 113/4" (298) 151/8" (384)
36" (914) 121/4" (311) 151/8" (384)
42" (1067) 151/4" (387) 151/8" (384)
48" (1219) 181/4" (464) 151/8" (384)
54" (1372) 211/4" (540) 151/8" (384)
60" (1524) 241/4" (616) 151/8" (384)
66" (1676) 271/4" (692) 151/8" (384)
HOOD RETAINING
BRACKET
B
TO BOTTOM
OF HOOD
A
30" TO 36"
(762–914)
BOTTOM OF
HOOD TO
COUNTERTOP
CENTER LINE
OF HOOD
LOCATION
1
/2" (13)
A
3
" (19)
/4
3
(92)
5
"
/8
Page 16
16
WOLF PRO WALL VENTILATION HOODS
24" (610) AND 27" (686) WALL HOODS
STEP 3: HOOD PREPARATION
IMPORTANT NOTE:
If a duct cover is to be used, follow instructions on page 18 before installing the wall hood. If you are installing a recirculating kit, refer to instructions included with the kit before installing the wall hood.
IMPORTANT NOTE:
Wolf recommends installing the internal blower to the back plate prior to mounting the hood.
If you are installing WBLOWER-60INT, WBLOWER-90INT or WBLOWER-120INT, refer to the internal blower information on page 21 and follow installation instructions provided with the blower assembly.
The hood assembly is shipped with the back plate/transition attached. The transition is shipped upside down in the top of the hood. It must be removed and rein­stalled in the proper position.
Remove the filters by pushing each filter up at the angle it is placed in, and rotate down. Remove the center filter first. Then take out the grease cups placed on the bottom edge of the hood coinciding with the bottom edge of the filters. Gloves should be worn to provide the proper grip when removing filters.
Detach the back plate/transition assembly from the hood by removing the screws from the top and back of the assembly. Refer to the illustration below.
Separate the transition from the back plate by removing the shipping nut from the inside of the back plate.
Position the back plate in the desired location and mark the mounting holes on the wood support. Drill pilot holes for the mounting hardware.
If you are installing an in-line or remote blower, drill an additional
7
/8" (22) hole through the wood framing for the conduit in order to run power to the blower. Refer to the illustration on page 19 for location of the electrical box and to the in-line and remote blower information on pages 22–23. Also, follow installation instructions provided with the blower assembly.
IMPORTANT NOTE:
Do not run wiring for the
remote blower through the ductwork.
Back plate/transition assembly
Page 17
17
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
24" (610) AND 27" (686) WALL HOODS
STEP 4: REATTACH BACK PLATE
Follow these instructions to reattach the back plate to the wall hood:
Attach the transition to the back plate using the four shipping screws provided in the hardware mounting kit.
Reinstall the shipping screws removed previously from the top and back of the back plate.
Use duct sealing tape to ensure a tight seal from the transition to the back plate.
IMPORTANT NOTE:
If additional support is required, drill supplementary mounting holes in the back plate and use these holes to attach the hood assembly to the wall framing.
Due to the weight of the hood, be sure to have adequate manpower for installation.
STEP 5: HOOD INSTALLATION
IMPORTANT NOTE:
If a backsplash is to be used, it should be installed before the wall hood is mounted. Refer to instructions included with the backsplash.
Follow these instructions to install the wall hood:
Align the mounting holes in the back plate of the hood assembly with the metal retaining brackets on the wood mounting support. Refer to the illustration below for location of the mounting holes.
Position the hood and install the #10 x 1
1
/2" (38) screws and washers (included in the hardware mounting kit) through the mounting holes on the back plate. Refer to the illustration below. Verify that the screws engage the wood mounting support.
Attach the transition to existing ductwork with sheet metal screws and duct sealing tape.
Location of mounting holes Hood installation
1
2
"
/2
(64)
MOUNTING
HOLES
7
4
"
/16
(113)
Page 18
18
WOLF PRO WALL VENTILATION HOODS
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
DUCT COVER INSTALLATION
Duct cover installation
Installing a duct cover assembly will impact all aspects of the hood installa­tion including hood location, ducting, electrical placement and the mounting surface.
Duct covers 6" (152), 12" (305), 18" (457) and 24" (610) high in widths to match all wall hoods are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
IMPORTANT NOTE:
If an optional duct cover is to be used with any Wolf Pro wall hood, follow these instructions before installing the hood:
Remove all screws from the front edge of the back panel on the top of the wall hood. Leave the two screws on the sides as there is a relief in the duct cover for them.
Attach the duct cover from the inside of the hood through the filter opening using the screws provided.
Leave screws partially loose until all screws are installed. Check alignment of the duct cover with the hood and tighten the four corner screws to secure the duct cover. Tighten all remaining screws.
Continue with the installation of the wall hood.
Optional
Duct Cover
Mounting
Screws
Page 19
19
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
Do not remove the control knob bezel to access hood wiring; this will damage the bezel assembly.
Location of electrical box
IMPORTANT NOTE
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
ELECTRICAL WIRING
This ventilation hood must be properly grounded. This unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on acciden­tally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Follow these instructions to install wiring for all Wolf Pro wall hoods:
Run a 120 V AC, 15 amp circuit power cable from the service panel to the electrical box on the back plate.
Run the conduit connector through the holes in the back plate. Refer to the illustra­tion below for the location of the electrical box.
Insert the conduit through the hole on top of the back plate to the electrical box.
Remove the electrical box cover from the back plate. Connect black wire to power supply black wire, white wire to power supply white wire and green wire to green wire or bare wire.
Place all wiring connections inside the electrical box and reinstall on the back plate in the upper right-hand corner. Make sure that the wires are secure and that no wires are pinched between the cover and box.
Electrical Box
Page 20
20
WOLF PRO WALL VENTILATION HOODS
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
FILTER INSTALLATION
Follow these instructions to install filters and grease cups for Wolf Pro wall hoods:
Remove all packaging material from the filters and grease cups.
Slide the grease cups along the bottom edge of the hood so that the lip of the grease cup overhangs slightly.
Install the filters. Orient each filter with lines running vertically. Position the top edge of the filter as shown in the illustra­tion below. While pressing up against the spring, rotate the bottom edge of the filter into position next to the grease cup. Gloves should be worn to provide proper grip when installing filters.
IMPORTANT NOTE:
The illustration shows a 27" (686) deep wall hood filter installation, with the filter sloping up from front to back. For low-profile and 24" (610) deep hoods, the filter will slope down from front to back.
WOLF NAMEPLATE
The Wolf logo nameplate does not come installed on the hood since there are various locations that the nameplate can be attached. Also, some customers prefer not to have a nameplate on their hood.
A template for positioning the Wolf logo nameplate in a standard location is included on the back page. Follow these steps to install the nameplate:
Decide on the location for the nameplate.
Clean the mounting area with rubbing alcohol.
If desired, cut out the template from the back page. Fold the template, locate place­ment on hood and tape to the hood surface. Check alignment and adjust if necessary.
Remove backing paper from the nameplate.
Position the nameplate in the template cut-out and press into place.
Remove the template and any tape residue.
Filter installation—27" (686) deep wall hood shown
Spring
Filter
Grease Cup SIDE VIEW
Page 21
21
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
INTERNAL BLOWERS
BLOWER INSTALLATION
IMPORTANT NOTE:
Refer to the specific installation instructions provided with each internal blower for additional mounting and wiring instructions.
IMPORTANT NOTE:
Use wire connectors or wire nuts approved by UL or C/UL.
IMPORTANT NOTE:
Wolf recommends installing the internal blower to the back plate assembly prior to installing the hood to the wall framing.
IMPORTANT NOTE:
For low-profile wall hoods using the 500 CFM internal blower, refer to the WBLOWER-50INT installation instruc­tions for details.
24" (610) AND 27" (686) DEEP HOODS
Assemble the blower housing to the blower mounting plate. Follow installation instruc­tions included with the blower assembly for proper installation.
Attach the blower assembly to the hood mounting plate. To attach, slide the blower mounting plate over the weld studs and secure with eight nuts (included with the blower). Refer to the illustration below.
Verify that the blower discharge aligns with the discharge cut-out in the back panel of the hood.
Install the hood and blower assembly to the wall. Secure the power cord(s) without damaging or pinching while installing the hood.
Follow hood installation instructions begin­ning on page 9 for low-profile wall hoods, and page 12 for 24" (610) and 27" (686) deep wall hoods.
Once the hood installation is complete, plug the blower power cord(s) into receptacle(s) located near the center of the hood shell. Refer to the illustration below. Use the clips on the interior of the hood to keep excess power cord away from moving parts.
IMPORTANT NOTE:
Before turning the power on to the ventilation hood, make sure the blower is off.
Internal blower installation
Blower Receptacle(s)
Blower receptacle location
Hood
Back Plate
Blower
Mounting
Plate
Blower
Housing
Page 22
22
WOLF PRO WALL VENTILATION HOODS
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
IN-LINE AND REMOTE BLOWERS
BLOWER INSTALLATION
IMPORTANT NOTE:
Refer to the specific installation instructions provided with each blower for additional mounting instructions.
Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. Wolf recommends the maximum linear duct run be no greater than 50' (15 m).
If possible, remote blowers should be located between wall studs or roof rafters. Avoid pipes, wires or other ductwork that may be running through the wall.
Be sure that there is enough space for any transitions that may be needed between the blower and the connecting ductwork. For best performance, locate transitions nearest the blower.
Refer to the illustrations below and on the following page for overall dimensions of Wolf in-line and remote blowers. Also refer to the specific installation instructions provided with each remote blower to verify cut-out dimen­sions.
Dimensions for BLOWER-60IL
Dimensions for BLOWER-110IL
243/8"
(619)
113/4"
(298)
181/2"
(470)
41/2"
(114)
211/2"
(546)
121/4"
(311)
7
24
/8
(632)
18"
(457)
12"
(305)
22"
(559)
8"
(203)
18"
(457)
"
Page 23
23
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
IN-LINE AND REMOTE BLOWERS
BLOWER WIRING
IMPORTANT NOTE:
Refer to the specific installation instructions provided with each blower for additional wiring instructions.
Follow wiring instructions at the blower as outlined in the specific installation instruc­tions provided with each blower. Black (L1) to black, white (neutral) to white, or white to blue, or white to brown (depending on model) and green to grounding screw. Run blower cable (ROMEX) to the hood.
Insert 6" (152) of ROMEX cable through the knockout opening and into the electrical box on the back plate of the hood. Secure the cable to the electrical box with an appropriate connector.
Locate the cord assembly provided with the blower. The cord assembly has two leads, black (L1) and white (neutral). Connect these leads to the leads from the blower, black to black and white to white.
Connect
all
green and bare wires together
to the ground screw in the electrical box.
Plug the cord assembly into the receptacle located near the center of the hood shell. Refer to the illustration on page 21. Use the clips on the interior of the hood to keep excess power cord away from moving parts.
Reinstall the electrical box cover and screws in the upper right-hand corner of the hood. Make sure that all wires are secure and that no wires are pinched between the cover and box.
IMPORTANT NOTE:
Before turning the power on to the ventilation hood, make sure the blower is off.
When making electrical connections, make sure the electrical power is turned off at the power source or circuit breaker before proceeding.
Dimensions for BLOWER-60REM and BLOWER-90REM
Dimensions for BLOWER-150REMDimensions for BLOWER-120REM
3
/4
20
"
28
(718)
1
/4
15
(394)
"
Diameter
1
"
/2
14"
(356)
10" (254)
3
/4
24
(629)
(527)
1
24
"
/2
(622)
3
4
"
/4
"
(121)
29
(749)
25"
(635)
21" (533)
10"
(254)
29
(749)
7
(184)
1
"
/2
1
"
/4
18" (457)
10"
1
"
/2
10" (254)
Diameter
3
14
"
/4
(375)
1
10
"
/8
(257)
22"
(559)
(254)
29
(749)
7
(184)
1
29
"
/2
(749)
1
/2
"
1
/4
"
14
(375)
10" (254)
Diameter
3
"
/4
3
10
"
/8
(264)
Page 24
24
WOLF PRO WALL VENTILATION HOODS
IN-LINE BLOWERS
BLOWER-60IL (808331) –
600 CFM in-line blower for low-profile wall hoods and 24" (610) and 27" (686) deep wall hoods, Models PW302418 and PW302718.
BLOWER-110IL (808332) –
1100 CFM in-line blower for all 24" (610) and 27" (686) deep wall hoods.
REMOTE BLOWERS
BLOWER-60REM (801640) –
600 CFM remote blower for low-profile wall hoods and Models PW302418 and PW302718.
BLOWER-90REM (801641) –
900 CFM remote blower for low-profile wall hoods and 24" (610) and 27" (686) deep wall hoods; 30" (762), 36" (914), 42" (1067), 48" (1219) and 54" (1372) wide models.
BLOWER-120REM (801642) –
1200 CFM remote blower for all 24" (610) and 27" (686) deep wall hoods.
BLOWER-150REM (804701) –
1500 CFM remote blower for all 24" (610) and 27" (686) deep wall hoods.
BLOWER ASSEMBLIES
Wolf Pro wall ventilation hoods are shipped without the blower assembly. Wolf internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer.
IMPORTANT NOTE:
Blower options vary with the cooking surface. Use only a Wolf blower with the Pro wall ventilation hood.
Refer to the Wolf Design Guide for Pro ventilation recommendations. You can also visit our website at wolfappliance.com.
INTERNAL BLOWERS
WBLOWER-50INT (810991) –
500 CFM internal blower for all low-profile wall hoods.
WBLOWER-60INT (810559) –
600 CFM internal blower for 24" (610) and 27" (686) deep wall hoods; 30" (762), 36" (914) and 42" (1067) wide models.
WBLOWER-90INT (811131) –
900 CFM internal blower for 24" (610) and 27" (686) deep wall hoods; 30" (762), 36" (914) and 42" (1067) wide models.
WBLOWER-120INT (810316) –
1200 CFM internal blower for 24" (610) and 27" (686) deep wall hoods; 48" (1219), 54" (1372), 60" (1524) and 66" (1676) wide models.
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
Page 25
25
Dimensions in parentheses are in millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
ACCESSORY KITS
RECIRCULATING KITS
RECIRC30 (808223) –
Must be used with WBLOWER-50INT (810991) for low-profile wall hoods and WBLOWER-60INT (810559) for 24" (610) deep wall hoods.
RECIRC36 (808224) –
Must be used with WBLOWER-50INT (810991) for low-profile wall hoods and WBLOWER-60INT (810559) for 24" (610) deep wall hoods.
Page 26
26
WOLF PRO WALL VENTILATION HOODS
The information and images in this book are the copyright property of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc.
©Wolf Appliance, Inc. all rights reserved.
CONTACT INFORMATION
Wolf Customer Service: 800-332-9513
Website: wolfappliance.com
IF YOU NEED SERVICE
Maintain the quality built into your Pro wall ventilation hood by calling a Wolf authorized service center.
For the name and number of the Wolf authorized service center nearest you, check the Constant Care section of our website,
wolfappliance.com
, or call Wolf
Customer Service at
800-332-9513
.
When calling for service, you will need the model and serial number of your ventilation hood. This information is found on the rating plate located on the left wall of the hood shell. Refer to the illustration on page 3.
TROUBLESHOOTING
IMPORTANT NOTE:
If the Pro wall ventilation hood does not operate properly, follow these troubleshooting steps:
Verify that power is being supplied to the ventilation hood.
Check electrical connections to ensure that the installation has been completed correctly.
Refer to the Troubleshooting Guide in the Wolf Pro Ventilation Hoods Use & Care Information.
If the ventilation hood still does not work, contact a Wolf authorized service center. Do not attempt to repair the ventilation hood yourself. Wolf is not responsible for service required to correct a faulty installation.
Page 27
27
FOLD LINE FOR LOGO PLACEMENT
BOTTOM EDGE OF HOOD
CUT-OUT FOR LOGO PLACEMENT
LEFT OUTER EDGE OF HOOD
Page 28
811504 7/2007
WOLF APPLIANCE, INC. P. O. BOX
44848
MADISON, WI
53744 800-332-9513
WOLFAPPLIANCE.COM