3L09
WHITE-RODGERS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
This series of limit controls has a normally closed SPST
switch that opens on temperature rise to limit the maximum allowable temperature in forced air heating sys-
THIS CONTROL MUST BE INSTALLED BY A QUALIFIED INSTALLER.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting components could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to re-calibrate this control will void the WhiteRodgers warranty.
WARNING
!
Do not use on circuits exceeding specified voltages. Higher voltages will damage control and
could cause shock or fire hazard.
If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a qualified heating and air conditioning contractor or a
licensed electrician.
Limit Controls
INSTALLATION INSTRUCTIONS
DESCRIPTION
tems. A small bimetal sensing element is located in the air
stream for quick response. These controls have a fixed
temperature setting and fixed differential.
PRECAUTIONS
CAUTION
!
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation.
Following installation or replacement, follow
appliance manufacturers’ recommended installation/service instructions to insure proper operation.
ELECTRICAL RATING:
Resistive: 15 amps @ 120 VAC
13 amps @ 240 VAC
9.3 amps @ 277 VAC
Inductive: 5.8 FLA, 34.8 LRA @ 120 VAC
2.9 FLA, 13.0 LRA @ 240 VAC
Pilot Duty: 278 VA
This control must be mounted in the air stream of the
appliance. Follow the original equipment manufacturers’
recommendations for proper location and wiring.
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
Printed in U.S.A.
SPECIFICATIONS
Temperature Setting:
Fixed setting stamped on control
INSTALLATION
Wiring
All wiring must conform to local and national
electrical codes and ordinances.
PART NO. 37-6133A