White-Rodgers
Universal
80 Series
Universal
Thermostats
• Auto-Changeover
• 7 Day, 5/1/1 Day Programmable
or Non-Programmable
• Hardwired or Battery Powered
1F85-277
Multi-Stage/Heat Pump/Single Stage
7 Day, 5/1/1 Day Programmable
or Non-Programmable
®
Single Stage/
Multi-Stage/Heat Pump
ACCURACY
OPTIMUM COMFORT
AND PERFORMANCE
1F85-275
Multi-Stage/Heat Pump/Single Stage
5/1/1 Day Programmable
or Non-Programmable
1F83-277
Multi-Stage/Heat Pump/Single Stage
Non-Programmable
Programmable
80 Series® Classic Universal Thermostats for
Single Stage, Multi-Stage, Heat Pump and Truck Stock Use.
We offer the best-selling digital thermostat by combining a single stage, multi-stage and heat pump into one universal
thermostat. And better yet we’ve enhanced it with styling and features specially designed for all systems. It offers
more control, more convenience and more value than the competition. And it’s backed with the reputation of
White-Rodgers — pioneers in home comfort since 1937.
More Accuracy and Control. If you’re in the
process of upgrading a multi-stage, heat
pump or single stage system, don’t forget
the “brain” for your new system…your
thermostat. Our White-Rodgers 80 Series®
can maintain a set temperature to within
one degree. Plus, there’s a permanent
memory that saves all programs and
settings during a power loss.
Comfort and Convenience with Versatility.
The programmable models deliver perfect
comfort, as they automatically change to
the temperature you selected for wake-up,
during the day, evening hours and while
you sleep. You can also configure them
with minimum and maximum temperature
range for cooling or heating. The lighted
display makes for clearer low-light viewing.
Non-Programmable
Maximum Energy Savings. Program heating
and cooling times to cut energy use, not
comfort. You can save up to 33% in energy
costs, depending on your home’s location,
climate and program selections.
Now you can have it all…energy savings, with
comfort and convenience! See the back to
find out how this best-seller gives you more
of what you want in a universal thermostat.
White-Rodgers
80 Series
®
Universal Thermostats
1F85-277
Multi-Stage/Heat Pump/Single Stage
7 Day, 5/1/1 Day Programmable
or Non-Programmable
• Auto-Changeover • 7 Day, 5/1/1 Day Programmable or Non-Programmable • Hardwired or Battery Powered
1F85-275
Multi-Stage/Heat Pump/Single Stage
5/1/1 Day Programmable
or Non-Programmable
1F83-277
Multi-Stage/Heat Pump/Single Stage
Non-Programmable
Programming (1F85-277)/(1F85-275)
Choice of 7 day or 5/1/1 day
programmable or non-programmable
4 time and 4 temperature settings per
program (heat & cool)
Energy savings up to 33%
Patented pre-programmed software
simplifies time and temperature
programming
Display
40% larger LCD with improved contrast for
easier reading
Lighted display for easier low-light viewing
Terminal Designations
E/W1
C GW2
R
24V Hot
24V
Common
(Optional)
Heat
Relay
(Stg. 1)
Heat
Relay
(Stg. 2)
Blower/Fan
Performance
Universal – Single Stage, Multi-Stage
or Heat Pump
Dual Powered (Hardwire and Battery)
(Patented)
Coded keypad lockout
Selectable Energy Management Recovery
(1F85-275)/(1F85-277)
Meets California Building Code, Title 24
(1F85-275)/(1F85-277)
Fast (FA) or slow (SL) heating cycle anticipation
Compressor lockout protection (optional)
Setpoint temperature limits
Y2
Y1 O B L
Cool
Relay
(Stg. 1)
Cool
Relay
(Stg. 2)
Energized
in Cool
Energized
in Heat
System
Monitor
Comfort & Convenience
Optional minimum and maximum
temperature configurable
Auto Changeover (optional)
Permanent program retention during
power loss, no batteries needed
Indefinite setpoint Hold
Air filter change indicator
Simple “set-up” menu to activate
optional features
Programmed temporary temperature
override 4 hours max.
Maintains room temperature differential
within +/- 1°
Display temperature recalibration (+/- 4°)
Includes 2 “AA” alkaline batteries for long
battery life
Dimensions
6.1"H x 3.8"W x 1.1"D
Electrical Specifications
Rating
20 to 30 VAC, 50/60 Hz or DC
0.05 to 1.0 Amp (load per terminal)
2.5 Amps maximum load (all terminals combined)
Standard Systems
Multi-Stage—2 stage heat, 2 stage cool
Heat Pump—2 or 3 stage heat, 1 stage cool
Single stage gas, oil, electric
Stages Heat/Cool
by System
Single
Multi-
Stage
Stage
2/2
1/1
2/2
1/1
2/2
1/1
* H/B= Hardwired or Battery option
Heat
Pump
2/1
2/1
2/1
Programs
Program
Options
7, 5+1+1,
5+1+1,
Ø
Ø
Ø
Model
Model
Number
1F85-277
1F85-275
1F83-277
Applications
3 Wire
Gas/Oil/
Zone
Electric
Valv e
✓
✓
✓
St. Louis, Missouri Markham, Ontario
314-553-3600 905-948-3411
Thermal Specifications
Setpoint Temperature Range:
45° to 90°F (7° to 32°C)
Rated Differential:
0.6° to 1.6°F with adjustable anticipation
Operating Ambient Temperature:
32° to 105°F (0° to 40°C)
Operating Humidity Range:
90% non-condensing maximum
Shipping Temperature Range:
-4° to 150°F (-20° to 65°C)
Selectable Performance Features
Thermostat
Millivolt
Compatible
Power
Source*
✓
✓
✓
www.white-rodgers.com
www.emerson.com
H/B
H/B
H/B
Auto
Changeover
✓
✓
✓
Program
Override
✓
✓
Energy
Management
Recovery
✓
✓
The Emerson logo is a trademark and
a service mark of Emerson Electric Co.
Programmable
Fan
Diplay
Size
(sq. in.)
2.2
2.2
2.2
Accessories
Wallplate F61-2500 (7.6"W x 4.8"H)
Thermostat Guard F29-0231
(For additional guard options refer
to White-Rodgers catalog)
For Additional Information
Visit www.white-rodgers.com
Comfort & Convenience Features
Alkaline
Lighted
Battery Life
Display
(Years)
2+
✓
2+
✓
2+
✓
Cool
Savings
Furnace Lockout
Ignition
Module Reset
✓
✓
✓
Memory
Back-up
P-Permanent
B-Battery
P
P
P
Warranty
(Years)
1
1
1
WR-2278-2A