White Rodgers 1F85-277, 1F83-277 Specification

White-Rodgers
Universal
80 Series
Universal Thermostats
• Auto-Changeover
• 7 Day, 5/1/1 Day Programmable or Non-Programmable
• Hardwired or Battery Powered
1F85-277
Multi-Stage/Heat Pump/Single Stage
7 Day, 5/1/1 Day Programmable or Non-Programmable
®
Single Stage/ Multi-Stage/Heat Pump
ACCURACY
OPTIMUM COMFORT AND PERFORMANCE
1F85-275
Multi-Stage/Heat Pump/Single Stage
5/1/1 Day Programmable or Non-Programmable
1F83-277
Multi-Stage/Heat Pump/Single Stage
Non-Programmable
Programmable
80 Series® Classic Universal Thermostats for Single Stage, Multi-Stage, Heat Pump and Truck Stock Use.
We offer the best-selling digital thermostat by combining a single stage, multi-stage and heat pump into one universal thermostat. And better yet we’ve enhanced it with styling and features specially designed for all systems. It offers more control, more convenience and more value than the competition. And it’s backed with the reputation of White-Rodgers — pioneers in home comfort since 1937.
More Accuracy and Control. If you’re in the
process of upgrading a multi-stage, heat pump or single stage system, don’t forget the “brain” for your new system…your thermostat. Our White-Rodgers 80 Series® can maintain a set temperature to within one degree. Plus, there’s a permanent memory that saves all programs and settings during a power loss.
Comfort and Convenience with Versatility.
The programmable models deliver perfect comfort, as they automatically change to the temperature you selected for wake-up, during the day, evening hours and while you sleep. You can also configure them with minimum and maximum temperature range for cooling or heating. The lighted display makes for clearer low-light viewing.
Non-Programmable
Maximum Energy Savings. Program heating and cooling times to cut energy use, not comfort. You can save up to 33% in energy costs, depending on your home’s location, climate and program selections.
Now you can have it all…energy savings, with comfort and convenience! See the back to find out how this best-seller gives you more of what you want in a universal thermostat.
White-Rodgers
80 Series
®
Universal Thermostats
1F85-277
Multi-Stage/Heat Pump/Single Stage
7 Day, 5/1/1 Day Programmable or Non-Programmable
• Auto-Changeover • 7 Day, 5/1/1 Day Programmable or Non-Programmable • Hardwired or Battery Powered
1F85-275
Multi-Stage/Heat Pump/Single Stage
5/1/1 Day Programmable or Non-Programmable
1F83-277
Multi-Stage/Heat Pump/Single Stage
Non-Programmable
Programming (1F85-277)/(1F85-275) Choice of 7 day or 5/1/1 day
programmable or non-programmable
4 time and 4 temperature settings per program (heat & cool)
Energy savings up to 33%
Patented pre-programmed software simplifies time and temperature programming
Display
40% larger LCD with improved contrast for easier reading
Lighted display for easier low-light viewing
Terminal Designations
E/W1
C GW2
R
24V Hot
24V
Common
(Optional)
Heat
Relay
(Stg. 1)
Heat
Relay
(Stg. 2)
Blower/Fan
Performance
Universal – Single Stage, Multi-Stage or Heat Pump
Dual Powered (Hardwire and Battery) (Patented)
Coded keypad lockout
Selectable Energy Management Recovery (1F85-275)/(1F85-277)
Meets California Building Code, Title 24 (1F85-275)/(1F85-277)
Fast (FA) or slow (SL) heating cycle anticipation
Compressor lockout protection (optional)
Setpoint temperature limits
Y2
Y1 O B L
Cool
Relay
(Stg. 1)
Cool
Relay
(Stg. 2)
Energized
in Cool
Energized
in Heat
System Monitor
Comfort & Convenience
Optional minimum and maximum temperature configurable
Auto Changeover (optional)
Permanent program retention during power loss, no batteries needed
Indefinite setpoint Hold
Air filter change indicator
Simple “set-up” menu to activate optional features
Programmed temporary temperature override 4 hours max.
Maintains room temperature differential within +/- 1°
Display temperature recalibration (+/- 4°)
Includes 2 “AA” alkaline batteries for long battery life
Dimensions
6.1"H x 3.8"W x 1.1"D
Electrical Specifications
Rating
20 to 30 VAC, 50/60 Hz or DC
0.05 to 1.0 Amp (load per terminal)
2.5 Amps maximum load (all terminals combined)
Standard Systems
Multi-Stage—2 stage heat, 2 stage cool
Heat Pump—2 or 3 stage heat, 1 stage cool
Single stage gas, oil, electric
Stages Heat/Cool
by System
Single
Multi-
Stage
Stage
2/2
1/1
2/2
1/1
2/2
1/1
* H/B= Hardwired or Battery option
Heat
Pump
2/1
2/1
2/1
Programs
Program Options
7, 5+1+1,
5+1+1,
Ø
Ø
Ø
Model
Model
Number
1F85-277
1F85-275
1F83-277
Applications
3 Wire
Gas/Oil/
Zone
Electric
Valv e
St. Louis, Missouri Markham, Ontario
314-553-3600 905-948-3411
Thermal Specifications
Setpoint Temperature Range: 45° to 90°F (7° to 32°C)
Rated Differential:
0.6° to 1.6°F with adjustable anticipation
Operating Ambient Temperature: 32° to 105°F (0° to 40°C)
Operating Humidity Range: 90% non-condensing maximum
Shipping Temperature Range:
-4° to 150°F (-20° to 65°C)
Selectable Performance Features
Thermostat
Millivolt
Compatible
Power
Source*
www.white-rodgers.com
www.emerson.com
H/B
H/B
H/B
Auto
Changeover
Program
Override
Energy
Management
Recovery
The Emerson logo is a trademark and a service mark of Emerson Electric Co.
Programmable
Fan
Diplay
Size
(sq. in.)
2.2
2.2
2.2
Accessories
Wallplate F61-2500 (7.6"W x 4.8"H)
Thermostat Guard F29-0231
(For additional guard options refer to White-Rodgers catalog)
For Additional Information
Visit www.white-rodgers.com
Comfort & Convenience Features
Alkaline
Lighted
Battery Life
Display
(Years)
2+
2+
2+
Cool
Savings
Furnace Lockout
Ignition
Module Reset
Memory Back-up
P-Permanent
B-Battery
P
P
P
Warranty
(Years)
1
1
1
WR-2278-2A