White Rodgers 1F85-0422 Wiring diagram

80 Series Thermostat
Heat Pump 1
(HP1)
O
Energized in
Cool Mode
B
Energized in
Heat, Off,
Emergency
Mode
No Output
Heat and Cool Mode 1st Stage (Compressor)
Blower/ Circulator Fan Energized on Call for Heat or Cool. Set Elect/Gas Option for Emergency Mode
Heat Mode 2nd Stage. Emergency Mode 2nd Stage
Emergency Mode 1st Stage
Optional*
24 Volt
(Com-
mon)
Fault Indicator or System Malfunction Switch
24 Volt (Hot) Cool
System
Y
W/E
C
L
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt (Hot) Heat
RH
Jumper
Y2
W2
G
Jumper
Comfort Alert II Module
or Similar System
Malfunction Module
O/B
Single Stage 1
(SS1)
Multi­Stage 2
(MS2)
O
Energized Constantly
in
Cool Mode
B
Energized Constantly
in Heat, Off, Emergency
Mode
No Output
Cool Mode 2nd Stage
Cool Mode 1st Stage
Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat)
No Output
Heat Mode 2nd Stage
Heat Mode 1st Stage
Optional*
24 Volt
(Com-
mon)
24 Volt (Hot) Cool
System
Y
G
W/E
C
L
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt (Hot) Heat
RH
Y2
W2
Jumper
Fault Indicator or System Malfunction Switch
Comfort Alert II Module
or Similar System
Malfunction Module
O/B
Wiring Diagrams for 1F83-0422 & 1F85-0422
Single Stage, Multi-Stage, Heat Pump
Heat Pump Connections
If you do not have a heat pump system, refer to figures 2 & 3. Refer to equipment manufacturers’ instructions for specific system wiring information. You can configure the thermostat for use with the following heat pump systems.
Figure 1 – Heat Pump Systems
Single Stage and Multi-Stage Connections
Refer to equipment manufacturers’ instructions for specific system wiring information. This thermostat is designed to operate a single-transformer or two­transformer system. You can configure the thermostat for use with the following fossil fuel systems:
HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas or electric backup.
NOTE: If your system
does not provide an E
connection, jumper W2 to
W/E to use the Auxiliary
Heat in the Emergency
Mode.
* Common connection
required for fault or
malfunction indication.
SINGLE STAGE (SS 1) gas, oil or electric. MULTI-STAGE (MS 2) gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration.
Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer
* Common connection
required for fault or
malfunction indication.
www.white-rodgers.com
PART NO. 37-9832A
0825
Figure 3 – Single Stage or Multi-Stage System (No Heat Pump) with Two
Single Stage 1
(SS1)
Multi­Stage 2
(MS2)
O
Energized Constantly
in
Cool Mode
B
Energized
Constantly in Heat, Off, Emergency
Mode
No Output
Cool Mode 2nd Stage
Cool Mode 1st Stage
Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat)
No Output
Heat Mode 2nd Stage
Heat Mode 1st Stage
Optional
24 Volt
(Com-
mon)
Fault Indicator (NOT USED)
24 Volt (Hot) Cool
System
Y
G
W/E
C
L
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt (Hot) Heat
RH
120VAC
Remove Jumper Wire between RH & RC
HOT
24VAC
NEUTRAL
CLASS II
TRANSFORMER
HEATING
COOLING
Y2
W2
Jumper
O/B
Single Stage 3-wire Zone Valve application
Blower/Circulator Fan Energized
Opens Va lve (4)
Constant
24 Volt
(Com-
mon)
24 Volt (Hot) Cool
System
6
Y
W
C
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt (Hot) Heat (5)
RH
G
Jumper
Closes Va lve (6)
Transformers
NOTE: If continuous backlight or
hardwired power input are desired but do not function in both HEAT and COOL modes, cut the heating transformer 24V wires and tape off. Connect the neutral circuit disconnected from the heating transformer to the neutral circuit of the cooling transformer. Disconnect the wire to the RH terminal and install a jumper between RH and RC. Depending on the system requirements, replace the cooling transformer with a 75VA class II transformer if needed.
Figure 4 – 3-Wire (SPDT) Heat Only Zone Valve Wiring