White-Rodgers 1F83C-11PR Instruction Sheet Manuals & Guides

Optional Accessory: Wall Cover-Up Plate F61-2663, 6 3/4” W x 4 1/2” H
WARNING
!
CAUTION
!
INDEX
Thermostat Installation
Wiring
Installer Menu
Using the Thermostat
Thermostat Overview
User Menu
Thermostat Operation
Thermostat Schedule
Troubleshooting
Homeowner Help Line
2-4
2
3-4
5-7
5
6
6
7
7-8
8
1F83C-11PR (Programmable)
Installation and Operating Instructions
Battery Powered or Hardwired with Common
Conventional Gas, Oil, Electric (mV and 24V), Heat Only, Cool Only or Heat/ Cool Systems
Heat Pump (air source or geothermal) with no Aux. Heat
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.
80 Series Single Stage Thermostat
Thermostat Applications
Maximum
Stages
Heat/Cool
1/1
1/1
THERMOSTAT INSTALLATION
WIRING
Refer to equipment manufacturer’s instructions for specic system wiring information. After wiring, see INSTALLER MENU for proper thermostat conguration. Wiring table shown are
for typical systems and describe the thermostat terminal functions.
Terminal Designations Terminal Function
RC* Power for Cooling
RH* Power for Heating
O/B
Y** Cooling Relay
G Fan Relay
W** Heating Relay
C
*When both RC and RH wires are present, cut RC/RH jumper (see next page). **For heat pump systems, add a jumper wire to connect terminals Y and W
Changeover Terminal-Energized in Heat (B) or Cool (O) for Heat Pump or Damper Systems
Common wire for 24V (optional with batteries)
Leveling Thermostat
Leveling is for appearance only and
will not aect thermostat operation.
SPECIFICATIONS
Electrical Rating:
Battery Power ..................................... mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire .................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load .......................................... 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (to 37° C)
Rated Dierentials: Fast Med Slow
Heat (@ 6°F/ Hr) .................................. 0.5°F 0.75°F 1.9°F
Cool (@ 6°F/ Hr) .................................. 0.9°F 1.2°F 1.7°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Operating Humidity ................................. 90% non-condensing max
Shipping Temperature Range ................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions ........................... 3-3/4” H x 6” W x 1-1/8” D
emersonthermostats.com white-rodgers.com
PART NO. 37-7478A-EN
1504
Precautions
• Do not exceed the specication ratings.
• All wiring must conform to local and national electrical codes and ordinances.
• This control is a precision instrument, and should be handled carefully. Rough handing or distorting components could cause the control to malfunction.
Do not use on circuits exceeding specied voltage.
Higher voltage will damage control and could
cause shock or re hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out thermostat and could cause personal injury
and/or property damage.
To prevent electrical shock and/or equipment
damage, disconnect electrical power to system,
at main fuse or circuit breaker box,until
installation is complete.
2
INSTALLER MENU (C0ntinued)
CAUTION
!
Baery Locaon
3
Premium AA alkaline batteries are required when C-wire is not available. When C-wire is
1
available, the batteries provide a back-up source of power (this will maintain the clock in the
2
event of a power outage).
1.) Gas/Elec Switch
If the system is a heat pump or electric furnace, the GAS/ELEC Switch must be set to
Elec. If your system is a gas or oil furnace, the switch must be set to Gas.
2.) O/B Terminal Switch
The O/B switch on this thermostat is factory set to the O position. This will accommodate
the majority of heat pump applications, which require the changeover relay to be energized in Cool. If the heat pump being installed requires a B terminal, to energize the changeover relay in Heat, the O/B switch must be moved to the B position.
3.) RC/RH Jumper Wire
This thermostat electrically connects the RC and RH terminals so a jumper wire is not
required. If the application provides a separate wire for RC and RH, clip the RC/RH jumper. This will isolate both terminals so they can be independently used.
INSTALLER MENU
To prevent changes that may aect system performance, this thermostat has an INSTALLER’S MENU and an USER MENU. The INSTALLER’S MENU provides access to every option, while the USER MENU provides access to items that will not aect system performance. To access the INSTALLER’S MENU press the Menu button for 8 seconds. The display will show item 30 in
the table below. Use Next and Back to navigate through menu items. Press or to change a menu setting.
Installer’s Menu #
(Hold Menu 8 Seconds)
30
35
50
65 66
74
(Installer Menu continued on next page)
3
Description
Heat Cycle Rate (how often
the heat will turn on)
Cool Cycle Rate (how often the cooling will turn on)
Compressor Lockout (protects the compressor from short cycling)
Maximum Heat Limit
(maximum set point for heat mode) Minimum Cool Limit (minimum
set point for cool mode)
Schedule Type (set as either 7-Day, 5-1-1 Day or Non-Programmable)
Default Setting
(ashing icons)
MEd
MEd
OFF
99 47 to 99
45 45 to 97
5
Settings
(Press or )
SLO – slow MEd – medium FAS – fast
SLO – slow MEd – medium FAS – fast
On – 5 minute display OFF – no delay
7 – 7 Day 5 – 5-1-1 Day 0 – Non Programmable
Installer’s Menu #
(Hold Menu 8 Seconds)
76
79
81
83
86
99
Description
Early Start (starts heating or
cooling early so your programmed temperature is reached by the programmed time)
Fahrenheit or Celsius °F
Temperature Display Adjustment (adjust the displayed
“Room Temperature”)
Continuous Display Light (keep the backlight always on – “C” wire required)
Change Air Filter (set up a monthly reminder)
Keypad Lock (prevent unwanted changes to the thermostat)
Default Setting
(ashing icons)
OFF
0 -5 to +5
OFF
OFF
OFF
Settings
On – start early OFF – start at program
period time
°F – Fahrenheit °C – Celsius
On – always on OFF – momentarily
1 to 12 – reminder time (months)
OFF – no lter reminder On – disable buttons
OFF – all buttons are
active
TEST EQUIPMENT
Turn on power to the system.
Fan Operation If your system does not have a G terminal connection, skip to Heating System.
1.) Move fan switch to On position. The blower should begin to operate.
2.) Move fan switch to Auto position. The blower should stop immediately.
Heating System
1.) Move System Switch to Heat position.
2.) Press to adjust thermostat setting to above room temperature. The system should
begin to operate and the thermostat will indicate Heat On.
3.) Press to adjust thermostat setting below room temperature. The heating system
should stop operating and the thermostat should indicate Heat.
Cooling System
1.) Move System Switch to Cool position.
2.) Press to adjust thermostat setting below room temperature. The blower should
come on immediately on high speed, followed by cold air circulation. The thermostat will indicate Cool On. There can be up to a 5 minute delay. (see INSTALLER MENU, item 50)
3.) Press to adjust thermostat setting to above room temperature. The cooling system
should stop operating and the thermostat will indicate Cool.
Note: If Starting Soon is shown on the display, the compressor lockout feature is operating.
There will be up to a 5 minute delay before the compressor turns on.(see INSTALLER MENU, item 50)
To prevent compressor and/or property damage, if the outdoor temperature is below 50°F,
Do not allow the compressor to run unless the compressor oil heaters have been operational
for 6 hours and the system has not been operational for at least 5 minutes.
DO NOT operate the cooling system.
4
USING THE THERMOSTAT
THERMOSTAT OVERVIEW
Before you begin using your thermostat, you should be familiar with its features, display and the location/operation of the thermostat buttons and switches.
THERMOSTAT BUTTONS AND SWITCHES THE DISPLAY
1.) Fan Switch 10.) Thermostat is protecting the equipment from short
2.) System Switch 11.) Indicates that the system is running in cool or heat
3.) Backlight Button (located on the top
of the thermostat
4.) Set Correct Time 13.) Battery status indicator
5.) Hold a Permanent Temperature 14.) Low battery indicator
6.) Cancels Hold – Returns to Programmed
Schedule
7.) Raises Temperature Setting 16.) Permanent hold (bypassing the schedule)
8.) Access Menu Options 17.) Temperature setpoint
9.) Lowers Temperature Setting 18.) Appears when the keypad is locked (to prevent unwanted
12
13
1
11
2
23
10
” appears in the display, new premium brand AA alkaline batteries
Whenever “ should be installed. If the house will be unoccupied for an extended period and either
or “
5
Replace
Replace
” is displayed, install new batteries before leaving.
cycling (5-minute delay)
12.) Displays the current time
15.) Day of the week used when programming a schedule
changes)
19.) Next (Menu button) is used to navigate within a menu
20.) Access the schedule and customize thermostat features
21.) Back (Run button) is used to navigate within a menu
22.) Exit (Hold button) returns to the home screen
23.) SEE TROUBLESHOOTING
14
4 5 6
3
22
15
16
21
17
20
19
7
18
8
9
“ ”
USER MENU
To customize thermostat settings, press the Menu button from the home screen. Use the
or buttons to highlight Settings and press Next. Use Next and Back to navigate
through menu items. Press or to change the setting.
User’s Menu # (Press Menu button and release)
01
02
03
04
05
06
07
Description
Schedule Type (set as either 7-Day,
5-1-1 Day or Non Programmable)
Early Start (starts heating or cooling early so your programmed temperature is reached by the programmed time)
Fahrenheit or Celsius °F
Temperature Display Adjustment
(adjust the Room Temperature)
Continuous Display Light (keep the backlight always on – “C” wire required)
Change Air Filter (set up a monthly reminder)
Keypad Lock (prevent unwanted changes to the thermostat)
Default Setting
(ashing icons)
5
OFF
0 -5 to +5
OFF
OFF
OFF
Settings (Press or )
7 – 7 Day 5 – 5-1-1 Day 0 – Non-programmable
On – start early OFF – start at program
period time
°F – Fahrenheit °C – Celsius
On – always on OFF – momentarily
1 to 12 – reminder time (months)
OFF – no lter reminder
On – disable buttons OFF – all buttons are active
THERMOSTAT OPERATION
Set Current Time and Day
Note: Time icons will ash at initial power up or after a reset.
1.) Press Set Time
2.) Use or to adjust the hour
3.) Press Next to advance to set the minutes and day of the week
4.) Press Exit when nished.
The default program is 5-1-1 Day, but can be setup as a 7-Day or Non-Programmable thermostat (refer to the User Menu above)
Hold Temperature (bypassing the schedule) – With the System switch set to Heat or Cool, momentarily press the Hold button. Hold will be displayed. Use or to adjust the temperature. The thermostat will hold the room temperature at the selected setting until you press Run to start program operation again.
Program Override (Temporary Hold) – Press or until the desired temperature is displayed. The thermostat will override the schedule until the next programmed time period with a minimum override of 2 hours. Then the thermostat will automatically revert to the program.
Keypad Lockout – To prevent unwanted changes, the buttons can be disabled. To turn this feature On, press and hold and the Menu button unl the icon appears (this can also be turned on in the menu). To turn O, press and hold and the Menu button for 3 seconds.
6
THERMOSTAT SCHEDULE
Energy Saving Factory Schedule
This thermostat is programmed with the energy saving settings shown in the table below for all days of the week.
Wake Leave Return Sleep
Heating Schedule
Cooling Schedule
Note: Thermostat can be programmed on or o the subbase
6:00 AM - 70°F 8:00 AM - 62°F 5:00 PM - 70°F 10:00 PM - 62°F
6:00 AM - 75°F 8:00 AM - 83°F 5:00 PM - 75°F 10:00 PM -78°F
Modify the Heating Schedule
1.) Slide the system switch to Heat
2.) Press Menu
3.) Press Next to enter the schedule
4.) The time icons will ash – use or to set the time for the start of a period
5.) Press Next – the set point icons will ash – use or to set the temperature for the
current period
6.) Continue to press Next to advance through all periods (Wake, Leave, Return, Sleep) for all days of the week.
Note: Press Back to return to the previous setting. Once all days of the week have been
programmed the thermostat will display End. Press Exit at any time to save changes and return to home screen.
Modify the Cooling Schedule
1.) Slide the system switch to Cool
2.) Repeat steps 2-6 from the heating schedule
TROUBLESHOOTING
Symptom Possible Cause Corrective Action
1.) Blown fuse or tripped circuit breaker
No Heat/ No Cool/ No Fan (common problem)
No Heat
(Troubleshooting continued on next page)
7
2.) Furnace power switch to OFF
3.) Furnace blower compartment
door panel loose or not properly installed
4.) Loose connection to thermostat or system
1.) System Switch not set to
Heat
2.) Loose connection to
thermostat or system
3.) Heating System requires
service or thermostat requires replacement
1.) Replace fuse or reset breaker
2.) Turn switch to ON
3.) Replace door panel in proper position to engage
safety interlock or door switch
4.) Tighten Connections
Verify thermostat and system wires are securely aached. Diagnosc: Set System Switch to Heat and raise the setpoint above room temperature. Within ve minutes the thermostat should make a so click sound and “Heat On” should appear on display. This sound indicates the thermostat is operang properly. If the thermostat does not click, try the reset operaon listed below. If the thermostat does not click aer being reset, contact your heang and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a service person to verify the heang system is operang correctly.
TROUBLESHOOTING (C0ntinued)
Symptom Possible Cause Corrective Action
1.) System Switch not set to Cool
2.) Loose connection to thermostat or system
No Cool
Heat, Cool or Fan Runs Constantly
Thermostat Display & Thermometer Disagree
Furnace (Air Conditioner) Cycles Too Fast or Slow (narrow or wide temperature swing)
“Call for Service” icon appears on displayed
3.) Cooling System requires service or thermostat requires replacement
Possible short in wiring, thermostat, heat, cool or fan system
Thermostat display requires adjustment
The location of the thermostat and/or the size of the Heating
System may be inuencing the
cycle rate
1.) Heating system is not able to heat the space to within 10 degrees of the setpoint within 2 hours
2.) Cooling system is not able to cool the space to within 10 degrees of the setpoint within 2 hours
3.) If “--” is displayed for the Room Temperature, a replacement thermostat is needed
4.) None of the buttons operate on the thermostat
Resetting the Thermostat or Thermostat Settings
If the thermostat has good batteries, but has a blank display or does not respond to key presses, the thermostat should be reset by removing the batteries for 2 minutes. This reset will not change the menu settings or program. If the condition persists after reinstalling the batteries, replace the thermostat.
To conveniently reset only the schedule and user settings back to factory defaults, press Menu and Backlight buttons at the same time and hold until the display goes blank and resets.
HOMEOWNER HELP LINE: 1-800-284-2925
White-Rodgers is a business of Emerson Electric Co.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
www.white-rodgers.com
www.emersonclimate.com
Verify thermostat and system wires are securely aached. Diagnosc: Set System Switch to Cool and lower setpoint below room temperature. Same procedures as diagnosc for “No Heat” condion except set the thermostat to Cool and lower the setpoint below the room temperature. There may be up to a ve minute delay before the thermostat clicks in Cooling if the compressor lock-out opon is selected in the installer menu. (see INSTALLER MENU, item 50)
Check each wire connection to verify they are not shorted or touching other wires. Try resetting the thermostat. If the condition persists contact your HVAC service person.
Display can be adjusted +/-5°. See User Menu item
04
Digital thermostats provide precise control and cycle faster than older mechanical models. The system
turns on and o more frequently but runs for a shorter
time. If you would like to increase cycle time, choose SLO for slow cycle in the Installer menu. (Reference menu items 30 & 35) If an acceptable cycle rate is not achieved, contact your HVAC service person.
1.) See corrective action for “No Heat”
2.) See corrective action for “No Cool”
3.) Replace thermostat
4.) Make sure keypad lockout is not turned on
(denoted by icon)