Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Your new White-Rodgers Digital Multi-stage Thermostat uses the technology of a solid-state microcomputer to provide precise time/temperature control.
Features:
• Simultaneous heat and cool setpoint storage
• Optional C terminal (dual power option)
• Optional B and O terminals
• Preprogrammed temperature control
This thermostat is intended for use with a 24-volt system; do not use this thermostat with a millivolt or line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician.
Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and
ordinances. This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause the control to malfunction.
1F83-71
Non-Programmable Electronic
Digital Automatic Changeover Multi-stage Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
DESCRIPTION
• LCD continuously displays setpoint and room temperature
°F/°C convertibility
• Temperature range 45° to 90°F
• Two-stage heat/two-stage cool
• Armchair programming capability
PRECAUTIONS
CAUTION
!
To prevent electrical shock and/or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
WARNING
!
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
ELECTRICAL DATA Electrical Rating:
20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO. 9797 REAVIS ROAD ST. LOUIS, MISSOURI 63123-5398
APPLICATIONS
For use with:
• Heat/cool systems with up to two stages heat, two
DO NOT USE WITH:
• Millivolt systems
• Systems exceeding 30 VAC and 2.5 amps
• 3-wire zoned hydronic heating systems
Printed in U.S.A.
SPECIFICATIONS
stages cool
PART NO. 37-6126B
0004
Page 2
INST ALLATION
Figure 1. Back of thermostat base
W905 CUT FOR LONGER CYCLES
GAS ELECTRIC
REMOVE OLD THERMOSTAT
1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.
2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
3. Identify each wire attached to the old thermostat using the
labels enclosed with the new thermostat.
4. Disconnect the wires from old thermostat one at a time. DO NOT LET WIRES FALL BACK INTO THE WALL.
5. Install new thermostat using the following procedures.
PRE-INSTALLATION SET-UP
1. Remove the packing material from the thermostat.
2. This thermostat is configured from the factory to operate a heat/cool, fossil fuel (gas, oil, etc.), forced air system with up to 2 stages of heat and 2 stages of cool. It is configured correctly for any system that DOES NOT require the thermo­stat to energize the fan on a call for heat.
If your system is an electric heat or heat-pump system that REQUIRES the thermostat to turn on the fan on a call for heat, locate the GAS/ELECTRIC switch on the back of the thermostat (see fig. 1) and switch it to the ELECTRIC position. This will allow the thermostat to energize the fan immediately on a call for heat. If you are unsure if the heating/ cooling system requires the thermostat to control the fan, contact a qualified heating and air conditioning service person.
3. One jumper is located on the back of the thermostat, so that you may customize the thermostat to meet your individual preference (see fig. 1). In most applications, the factory jumper settings provide the most comfortable and conve­nient thermostat operation.
Jumper wire W905 determines how fast the system cycles on and off, based on temperature change. As shipped from the factory, the thermostat will maintain a very consistent room temperature, usually within 1°F of the thermostat setting. To achieve a slower on and off cycle, providing a slightly wider temperature span, cut and separate jumper wire W905.
INSTALLING THE THERMOSTAT
1. Gently remove the cover by pulling it straight off the base. Forcing or prying on the unit may cause damage to the unit.
2. Remove the battery tab. With the batteries installed, the Armchair Programming feature allows you to program the thermostat before installing it on the wall.
3. Pull wires through the hole in the thermostat base and place the base over the hole in the wall. Mark mounting hole locations on the wall using the base as a template.
4. Move the base out of the way. Drill mounting holes.
5. Fasten the base loosely to the wall, as shown in fig. 2, using two mounting screws. Place a level against the bottom of the base, adjust until level, and then tighten the screws. (Level­ing is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if the holes drilled are too large and do not allow you to tighten the base snugly, use plastic screw anchors to secure the base.
Alkaline batteries (3 “AA”–
install “+” ends to the left)
Screw anchors
C
W
W2
O
R
G
Reset button
Mounting
holes
B
Y
Y2
Figure 2. Thermostat base
6. Check that the system is turned off. Connect the wires beneath the terminal screws on the base using the appropri­ate wiring diagram (see figs. 3 through 5).
7. Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.
CHECK THERMOSTAT OPERATION
NOTE
If at any time during testing, your system does not operate properly, contact a qualified serviceperson.
Fan Operation
1. Turn on power to the system.
2. Press SYSTEM button until the system is OFF.
3. Move FAN switch to ON. The blower should begin to operate.
4. Move FAN switch to AUTO position. The blower should stop within a short period of time.
(Instructions continue on page 4.)
2
Page 3
The following wiring diagrams show typical terminal identifica-
C* R
Y2
Compressor
Contactor
Stage 1
Heat
Relay
Stage 1
Heat
Relay
Stage 2
Thermostat
Control
Circuit
Limit or
Safety
Switches
Limit or
Safety
Switches
Limit or
Safety
Switches
Limit or
Safety
Switches
24 VAC 120 VAC
Hot
Common
Common
Neutral
THERMOSTAT
SYSTEM
Y W
W2
Figure 5. Typical wiring diagram for two-transformer systems with safety circuits in BOTH systems
Fan
Relay
G
HEATING
TRANSFORMER
Compressor
Contactor
Stage 2
24 VAC 120 VAC
Hot
Neutral
COOLING
TRANSFORMER
TWO COMMONS MUST
BE JUMPERED TOGETHER!
24 VAC Accessory Relay N.O.
Contact
* The 24 Volt neutral connection
to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer
®
alkaline
batteries.
O
Energized
in COOL
B
Energized
in HEAT
tion and wiring. For proper installation, refer to the original manufacturer’s instructions.
W2
Heat
Relay
Stage 2
Energized
in HEAT
Energized
in COOL
Y2OB
Y W
Compressor
Contactor
Stage 2
Compressor
Contactor
Stage 1
G
Heat
Relay
Stage 1
Fan
Relay
Figure 3. Typical wiring diagram for single transformer systems
NOTENOTE
Relay contacts shown are thermostatically operated.
* The 24 Volt neutral connection
to terminal C on the thermostat
Thermostat
Control
Circuit
C* R
THERMOSTAT
SYSTEM
Hot
24 VAC 120 VAC
Neutral
TRANSFORMER
Thermostat
Control
Circuit
is not required if you replace the batteries once a year with fresh “AA” Energizer batteries.
* The 24 Volt neutral connection
to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer® alkaline batteries.
®
alkaline
CUT AND
TAPE OFF!
Hot
Neutral
TRANSFORMER
Y W
Compressor
24 VAC120 VAC
Compressor
BE JUMPERED TOGETHER!
Contactor
Contactor
Stage 1
TWO COMMONS MUST
Y2
Stage 2
G
Fan
Relay
O
Energized
in COOL
B
Energized
in HEAT
Heat
Relay
Stage 1
W2
Heat
Relay
Stage 2
C* R
Figure 4. Typical wiring diagram for two-transformer systems with NO safety circuits
3
THERMOSTAT
SYSTEM
Hot
24 VAC 120 VAC
Neutral
TRANSFORMER
Page 4
Heating System
1. Press SYSTEM button to turn thermostat to HEAT.
2. Press to adjust thermostat setting to 90° and hold for five seconds. After you release the button, both stages of the
heating system should begin to operate within five seconds.
3. Press to adjust temperature setting below room tempera­ture. The auxiliary heating system will stop immediately and
the first stage will stop within three to four minutes.
Cooling System
CAUTION
!
To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.
1. Press SYSTEM button to turn thermostat to COOL.
2. Press to adjust thermostat setting to 45° and hold for five seconds. After you release the button, the blower should
come on immediately on high speed, followed by cold air circulation. Both stages of the cooling system should begin to operate (if you have a two-stage cooling system).
If the fan is running but the compressor is not running and the word COOL is flashing, the compressor lockout feature is operating (see Lockout Bypass Option to temporarily override the compressor lockout feature during testing).
3. Press ture. The cooling system should stop operating.
to adjust temperature setting above room tempera-
NOTE
During normal operation, the second stage of heat or cool may take 15 to 30 minutes to turn on. The delay varies depending on the performance of the first stage. Typically the second stage will come on sooner in more severe weather, while in milder weather it will take longer. There is no adjustment to this feature, as it is designed to maximize both comfort and efficiency.
LOCKOUT BYPASS OPTION
FOR QUALIFIED SERVICE TECHNICIANS’ USE ONLY. OPERATORS SHOULD NOT USE THIS FEA­TURE DUE TO POSSIBILITY OF EQUIPMENT OR PROPERTY DAMAGE, OR PERSONAL INJURY.
COMPRESSOR SHORT TERM
CYCLE PROTECTION
During normal operation, this thermostat has a built-in short term (5-minute) time delay. During this 5-minute period, the thermostat will lock out the compressor to allow head pressure to stabilize. If you want to over­ride this feature while testing thermostat operation,
simply press and buttons at the same time.
DO NOT USE THE LOCKOUT BYPASS OPTION UNLESS THE COMPRESSOR OIL HEATERS HAVE BEEN OPERATIONAL FOR 6 HOURS AND THE SYSTEM HAS NOT BEEN OPERATIONAL FOR AT LEAST 5 MINUTES.
4
Page 5
Before you begin using your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. Your thermostat consists of two parts: the thermostat cover and the base. To remove the cover, gently pull it straight out from the base. To replace the cover, line up the cover with the base and press gently until the cover snaps onto the base.
THE THERMOSTAT BASE
Other than and , the following buttons and switches are located behind the door on the bottom of the thermostat cover
(see fig. 6). Pull the door down to open it.
The Thermostat Buttons and Switches
(Red arrow) Raises temperature setting.
1
(Blue arrow) Lowers temperature setting.
2
SYSTEM button (COOL, OFF, HEAT, AUTO).
3
FAN switch (ON, AUTO).
4
The Display
HT is displayed when the SYSTEM button has been pressed
5
to put the thermostat in the HEAT mode. CL is displayed when the SYSTEM button has been pressed to put the thermostat in the COOL mode. CL is displayed (flashing) when the compressor is in lockout mode. AUTO is displayed when the SYSTEM button has been pressed to put the thermostat in the automatic changeover (AUTO) mode. 1+2 indicates the number of stages the thermostat is calling for.
Displays current temperature.
6
LOCK is displayed when keypad lockout has been acti-
7
vated. Displays current setpoint temperature (this is blank when
8
SYSTEM button has been pressed to turn the system OFF). LO BATTERY is displayed when approximately 70% of
9
battery life has been exhausted.
OPERATING FEATURES
Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the thermostat.
TEMPERATURE SETPOINT — Press or until the display shows the temperature you want.
SIMULTANEOUS HEATING/COOLING SETPOINT STORAGE — You can enter both your heating and cooling setpoints at the same time.
AUTOMATIC CHANGEOVER —If you have a heating/ cooling system, you can set the thermostat to automatically switch from heat to cool as needed to maintain setpoint temperature. To select this mode, press SYSTEM button until AUTO is displayed along with HEAT or COOL.
In AUTO mode, pressing and at the same time will change the displayed setpoint temperature to the setpoint
of the other mode (HEAT or COOL). This allows you to change both the HEAT and COOL setpoints, if desired.
TOTAL KEYPAD LOCKOUT — This security feature al- lows you to lock out the thermostat buttons to prevent
OPERATION
1
AUTO
FAN ONSYSTEM
COOL-OFF-HEAT-AUTO
3 4
5
HT 1+2
6 8
Figure 6. Thermostat display, buttons, and switches
unauthorized tampering. To select this feature, press and SYSTEM button at the same time and hold until LOCK
is displayed. To unlock the thermostat, press and SYSTEM buttons at the same time until LOCK is no longer
displayed.
°F/°C CONVERTIBILITY — Press and SYSTEM but-
tons until the temperature display is in Celsius. To display Fahrenheit, repeat the process.
TEMPERATURE DISPLAY ADJUSTMENT — Your new thermostat has been accurately set in our factory. However, if you wish, you may adjust your new thermostat tempera­ture display. This can be accomplished (within a ±4°F range) as follows:
1. Press and hold and SYSTEM buttons at the same
time until the actual temperature only is displayed (about 5 seconds).
2. Press or to adjust the displayed temperature to
your desired setting. (To reset the temperature display back to the actual sensed temperature, press and
SYSTEM buttons at the same time again.)
3. Press SYSTEM to resume normal thermostat operation.
If your thermostat’s display is frozen or displaying incorrectly, the thermostat may have been affected by static discharge or voltage variations. If this happens, press the RESET button (see fig. 2, page 2 for the location of the button). If pressing the RESET button does not correct the problem, contact a qualified service technician.
For optimum performance, we recommend replacing batteries once a year with fresh “AA” Energizer
5
OFF
CL 1+2
LOCK
5
7
BATTERY
9
TROUBLESHOOTING
®
alkaline batteries.
2
Page 6
Loading...