White Rodgers 1F83-261, 1F81-261 Wiring diagram

C* R
Y2
Compressor
Contactor
Heat
Relay
Heat
Relay
Stage 2
Thermostat
Control
Circuit
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
Y W
W2
Typical wiring diagram for single transformer systems
Fan
Relay
G
TRANSFORMER
Compressor
Contactor
* The 24 Volt neutral connection
to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer® alkaline batteries.
CONFIGURATION AND
1
Displayed (Factory Default) Press or to select: COMMENTS
HOLD (0:00)
0 to 8 hrs (in
15 minute increments)
2
(FA)
SL
Select temporary Hold time
4
5
E
(ON)
OFF
6
7
LOC
(OFF)
ON
0 HI
(0)
4 LO to
4 HI
°(F) °C
Returns to normal operation
9
10
Select Energy Management Recovery OFF or ON
Select compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to °F or °C
Select ON to start 2nd stage immediately when the setpoint is manually raised more than 3° F in HEAT or lowered more than 3° F in COOL from room temperature
RUN
PRGM
and RUN
HOLD
*
HOLD
*
3
d-L
(ON)
OFF
OFF
Select display backlight OFF or ON
HOLD
*
HOLD
*
Filter (000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
HOLD
*
HOLD
*
HOLD
*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
* Press
HOLD to advance to next item or TIME to move backwards to previous item
1 + 2
FA
(ON)
8
1F83-261
Press Button(s)
1F81-261
Press Button(s)
Step
HOLD
*
N/A
N/A
N/A
Set SYSTEM
switch to OFF
and Press
and
and
and
and
and
and
Set SYSTEM
switch to HEAT
or COOL
C* R
Y2
Compressor
Contactor
Stage 1
Heat
Relay
Stage 1
Heat
Relay
Stage 2
Thermostat
Control
Circuit
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
Y
W
W2
Typical wiring diagram for two-transformer systems with NO safety circuits
Fan
Relay
G
TRANSFORMER
Compressor
Contactor
Stage 2
24 VAC120 VAC
Hot
Neutral
TRANSFORMER
TWO COMMONS MUST
BE JUMPERED TOGETHER!
CUT AND
TAPE OFF!
* The 24 Volt neutral connection
to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” Energizer® alkaline batteries.
TYPICAL WIRING DIAGRAMS
1F81-261 1F83-261
NOTE
The following wiring diagrams show typical terminal identication and wiring. For proper installation, refer to the original manufacturer’s instruc­tions.
Relay contacts shown are thermostatically operated.
www.white-rodgers.com
Reset Operation: 1F81-261
If a voltage spike or static discharge blanks out the display or causes er­ratic thermostat operation, you can reset the thermostat by pressing , and TIME at the same time. This also resets the factory defaults to the
conguration menu and program. If the
thermostat has power, has been reset and still does not function correctly, contact your heating/cooling service person or place of purchase.
Reset Operation: 1F83-261
If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by pressing , and move the SYSTEM switch from OFF to HEAT at the same time. This also
resets the factory defaults to the configuration menu. If the thermostat
has power, has been reset and still does not function correctly, contact your heating/cooling service person or place of purchase.
181