30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS |
PRODUCT DIMENSIONS |
|
WFG20S0FS |
WFG525S0H |
WFG550S0H |
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
GAS SUPPLY REQUIREMENTS |
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of gas |
|
|
|
|
|
|
|
|
|
|||||
Natural gas: |
|
A |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|||||||||
■■ This range is factory set for use with Natural gas. See “Gas |
|
|
|
|
|
|
|
|
|
|||||
Conversions” section. The model/serial rating plate located on the |
|
|
|
|
|
|
|
|
|
|||||
oven frame behind the top left side of the oven door has information |
|
|
|
|
|
|
|
|
|
|||||
on the types of gas that can be used. If the types of gas listed do not |
F |
|
|
|
|
|||||||||
|
|
C |
|
|||||||||||
include the type of gas available, check with the local gas supplier. |
B |
|
|
|||||||||||
|
|
|
|
|
|
|
||||||||
Propane gas conversion: |
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
||||||
Conversion must be done by a qualified service technician. No attempt |
|
|
|
|
|
|
|
|
|
|||||
shall be made to convert the appliance from the gas specified on the |
|
|
|
|
|
|
|
|
|
|||||
model/serial rating plate for use with a different gas without consulting |
|
|
|
|
|
|
|
|
|
|||||
the serving gas supplier. See “Gas Conversions” section. |
|
|
|
|
|
|
|
|
|
|||||
GAS SUPPLY LINE |
|
|
E |
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
■■ Provide a gas supply line of 3/4" (19 mm) rigid pipe to the range |
|
|
|
|
|
|
|
|
|
|||||
|
|
|
D |
|
|
|
|
|
||||||
location. A smaller size pipe on longer runs may result in insufficient |
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|||||||
gas supply. With Propane gas, piping or tubing size can be 1/2" |
|
|
|
|
|
|
|
|
|
|||||
(13 mm) minimum. Usually, Propane gas suppliers determine the |
|
|
|
|
|
|
|
|
|
|||||
size and materials used in the system. |
A. 277/8" (70.8 cm) max. depth with handle |
|
|
|
|
|||||||||
NOTE: Pipe-joint compounds that resist the action of Propane gas |
B. 36" (91.4 cm) cooktop height (max.) with leveling legs screwed all the |
|||||||||||||
must be used. Do not use TEFLON®† tape. |
way in* |
|
|
|
|
|||||||||
Flexible metal appliance connector: |
C. 467/8" (119.1 cm) overall height (max.) with leveling legs screwed all |
|||||||||||||
■■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to |
the way in* |
|
|
|
|
|||||||||
D. 297/8" (75.9 cm) width |
|
|
|
|
||||||||||
152.4 cm) long, 1/2" (13 mm) or 3/4" (19 mm) I.D., flexible metal |
E. 257/16" (64.6 cm) depth. Back of range to front of cooktop** |
|
|
|||||||||||
appliance connector may be used for connecting range to the gas |
F. Model/serial rating plate (located on the oven frame behind the |
|||||||||||||
supply line. |
||||||||||||||
top left side of the oven door) |
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
IMPORTANT: Range must be level after installation. Follow the |
|
|
|||||||
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
instructions in the “Level Range” section. Using the cooktop as a |
|
|
|||||||
|
|
|
|
|
reference for leveling the range is not recommended. |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
||||||
■■ A 1/2" (13 mm) male pipe thread is needed for connection to the |
|
|
|
|
||||||||||
* Range can be raised approximately 1" (2.5 cm) by adjusting the |
||||||||||||||
female pipe threads of the inlet to the appliance pressure regulator. |
||||||||||||||
leveling legs. |
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
||||||
■■ Do not kink or damage the flexible metal tubing when moving the |
** Front of door and drawer may extend further forward, depending on |
|||||||||||||
range. |
styling. |
|
|
|
|
|||||||||
■■ Must include a shutoff valve: |
|
|
|
|
|
|
|
|
|
|||||
The supply line must be equipped with a manual shutoff valve. This |
|
|
|
|
|
|
|
|
|
|||||
valve should be located in the same room but external to the range |
|
|
|
|
|
|
|
|
|
|||||
opening, such as an adjacent cabinet. It should be in a location that |
|
|
|
|
|
|
|
|
|
|||||
allows ease of opening and closing. Do not block access to shutoff |
|
|
|
|
|
|
|
|
|
|||||
valve. The valve is for turning on or shutting off gas to the range. |
|
|
|
|
|
|
|
|
|
B
A
C
A.Gas supply line
B.Shutoff valve “open” position
C.To range
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. |
Page 1 of 2 |
Because Whirlpool Corporation includes a continuous commitment to improve our |
Dimensions are for planning purposes only. For complete details, see Installation |
Ref. W10545337B |
products, we reserve the right to change materials and specifications without notice. |
Instructions packed with product. Specifications subject to change without notice. |
04/19/2017 |