Whirlpool Duet WGD9450W, Duet WGD9470W, Duet WGD9550W, Duet WGD9600T, Duet WGD9750W Product Dimensions

0 (0)
Duet Steam and Non-Steam Electronic Gas Dryer
27
"
(686 mm)
38
"
(965 mm)
NON-STEAM - 511/2
"
(1308 mm)
STEAM - 529/16
"
(1335 mm)
NON-STEAM - 311/2
"
(800 mm)
*STEAM - 329/16
"
(827 mm)
27
"
(686 mm)
38
"
(965 mm)
1
"*
(25 mm)
1
"*
(25 mm)
NON-STEAM - 5
"**
(127 mm)
STEAM - 51/2
"**
(140 mm)
NON-STEAM - 311/2
"
(800 mm)
STEAM - 329/16
"
(827 mm)
27
"
(686 mm)
14
" max.
(356 mm)
18
" max.
(457 mm)
1
"
(25 mm)
1
"
(25 mm)
76
"
(1930 mm)
6
"
(152 mm)
3
"
(76 mm)
3
"
(76 mm)
48 in.2 *
(310 cm
2
)
24 in.
2
*
(155 cm
2
)
5
"
(127 mm)
NON-STEAM - 311/2
"
(800 mm)
STEAM - 329/16
"
(827 mm)
14
"* max.
(356 mm)
9
"*
(229 mm)
7
"*
(178 mm)
7
"*
(178 mm)
18
"* max.
(457 mm)
27
"
(686 mm)
1
"*
(25 mm)
1
"*
(25 mm)
14
"
(356 mm)
37/16"
(87 mm)
1
"
(25 mm)
75/8"
(194 mm)
33/8"
(86 mm)
1
"
(25 mm)
4"
(102 mm)
2½"
(64 mm)
4" (102 mm)
4" (102 mm)
B
A
Number of 90 turns or elbows
Ty pe of vent
Box or Louvered hoods
Angled hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5 m)
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
PRODUCT MODEL NUMBERS
WGD9450W, WGD9470W, WGD9550W, WGD9600T, WGD9750W
Gas supply: This dryer is equipped for use with Natural
gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required for gas dryers, 30 amp for electric dryers. A time-delay fuse or circuit breaker and a separate circuit are recommended.
Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Hood styles: A & B are recommended.
C
OVERALL DIMENSIONS
Dryer dimensions
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
Custom undercounter installation-dryer only
Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. See Installation Instructions, “Venting Requirements.”
A. Louvered hood B. Box hood C. Angled hood (acceptable)
The vent system chart provides venting requirments that will help to achieve the best drying performance.
Vent system chart: NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Back View
Side View
For dryer on pedestal; cabinet installation, with a door, the minimum ventilation openings in the top are required.
*Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specied in vent length chart. Determine the number of elbows you will need.
Ref. W10255469B
11/2010
Loading...