S E R V I C E |
Whirlpool Europe |
Customer Services |
ARG 090/G/WP
Service Manual
Mini-bar
ARG 090/G/WP
Model |
ARG 090/G/WP |
|
Version |
8534 090 10005 |
Page |
|
Technical data |
2 |
|
Spare part list |
3 |
|
Exploded view |
4 |
|
Circuit and Wiring diagram |
5 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 12.11.2003 (Mod. 01) |
Subject to modification |
Document-No.: 4812 731 14425 |
|
10.01.2003 / Page 2 |
ARG 090/G/WP |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 731 14425 |
8534 090 10005 |
Customer Service |
||
Technical data |
|
|
|
|
Factory Code |
|
RE 090 X |
|
|
Dimensions |
|
|
|
|
Height |
|
55.0 |
|
cm |
Width |
|
55.0 |
|
cm |
Depth |
|
60.3 |
|
cm |
Capacity |
|
|
|
|
gross |
|
90 |
|
l |
net |
|
88 |
|
l |
Electrical connection |
|
|
|
|
Voltage |
|
220 - 240 |
|
V |
Frequency |
|
50 |
|
Hz |
Power consumption |
|
|
|
|
in 24 hours |
|
0.49 |
|
kWh |
Compressor |
|
|
|
|
Type |
|
EMT 22 HLP |
|
|
Capacity (CECOMAF) |
|
53 |
|
W |
Refrigerant |
|
|
|
|
Type |
|
R 134 a |
|
|
Quantity |
|
55 |
|
g |
Thermostat switching value |
|
|
|
|
Switch on temperature min. |
|
- 1.5 |
|
˚C |
Switch on temperature max. |
|
- 10.5 |
|
˚C |
Switch off temperature min. |
|
- 7.5 |
|
˚C |
Switch off temperature max. |
|
- 16.5 |
|
˚C |