Detailed Specification & Technical Data
D25454
22/2 Bonded Shield CMP
Audio and Control
Construction & Dimensions
|
CONSTRUCTION & DIMENSIONS |
|
- |
|
|
|
CONDUCTOR PARAMETER |
|
- |
|
|
|
• Number of Pairs |
|
1 |
|
|
|
• AWG Size |
|
22 |
|
|
|
• Conductor Stranding |
|
7x30 |
||
|
• Conductor Type |
|
Tinned Copper |
||
|
• Nominal DCR |
|
17 Ohm/1000ft |
||
|
INSULATION PARAMETER |
|
- |
|
|
|
• Insulation Type |
|
FEP |
||
|
• Insulation Thickness |
|
0.007 in |
||
|
• Insulation Color Code |
|
1. Black 2.Red |
||
|
SHIELDING PARAMETER |
|
- |
|
|
|
• Shield Type |
|
Bonded Overall 100% Aluminum Foil |
||
|
• Drain Wire Type |
|
Tinned Copper |
||
|
• Drain Wire AWG |
|
22 AWG |
||
|
ELECTRICAL CHARACTERISTICS |
|
- |
|
|
|
• Nominal Impedance |
|
45 Ohm |
||
|
• Nom. Cap. Between Conductors |
|
34 pF/ft |
||
|
• Nom. Cap. Conductor to Shield |
|
67 pF/ft |
||
|
Overall Construction |
|
|
|
|
|
|
|
|
|
|
|
OVERALL CONSTRUCTION PARAMETERS |
|
- |
|
|
|
Jacket Type |
|
Flexible Plenum |
||
|
Jacket Thickness |
|
0.018 in |
||
|
Nominal Cable O.D. |
|
0.13 in |
||
|
Plenum |
|
Yes |
||
|
NEC UL Rating |
|
CMP |
||
|
RoHS Compliant |
|
Yes |
||
|
Pull Tension |
|
33 lbs |
||
|
Bend Radius |
|
1.17 in |
||
|
Cable Weight |
|
15 lbs |
||
|
Overall Electrical & Optical Characteristics |
|
|
|
|
|
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS |
|
|
- |
|
|
UL Flammability |
|
|
NFPA 262 Plenum |
|
|
Operating Range |
|
|
-0 to 60 Deg C |
|
|
UL Voltage Rating |
|
|
300 |