West Penn C6C-114BK-10FB, C6C-114BK-15FB, C6C-114BK-20FB, C6C-114BK-25FB, C6C-114BK-3FB Specsheet

...
0 (0)
West Penn C6C-114BK-10FB, C6C-114BK-15FB, C6C-114BK-20FB, C6C-114BK-25FB, C6C-114BK-3FB Specsheet

Detailed Specification & Technical Data

C6C-114cc-xxFB

Category 6 UTP Assembly

PRODUCT OVERVIEW

-

 

 

Product Description

 

Category 6 Patch Cords w/Snag-Proof Boots

Product Overview

 

West Penn continues to set the standard for high-quality, high-performance patch cords with two

 

 

series of category 6 patch cords. Our category 6 cords are 100% transmission tested to component

 

 

performance as specified in ANSI/TIA-568-C.2. Assembled in a con-trolled environment using ad-

 

 

vanced manufacturing techniques to ensure consistent quality, these patch cords provide exceptional

 

 

performance when mated with our category 6 connecting hardware.

 

 

West Penn category 6 patch cords incorporate slim-profile snag-free boots, which protect the plug

 

 

latch, and a flexible, but durable cable strain relief and are compatible with both T568A and T568B

 

 

wiring schemes. Category 6 patch cords are manufactured using ETL-verified stranded cable de-

 

 

signed for greater flexibility and service life and are available in eight popular colors and a variety of

 

 

standard lengths

 

 

Package Qty.

 

1

 

 

 

 

 

 

 

Product Features

-

 

 

 

 

• Transmission performance per TIA/EIA-568-C.2 performance specifications

 

• ETL verified 26-AWG stranded cable

 

• 100% factory transmission tested to component level performance per TIA/EIA-568-C.2

Features

• Rated for at least 750 plug insertions

 

• Enhanced plug-to-jack connection integrity

 

• Slim-profile snag-free boots with durable flexible cable strain relief

 

• T568A/B wiring scheme compatible

 

 

 

 

 

SPECIFICATIONS & DIMENSIONS

-

 

Transmission Performance

 

ANSI/TIA/EIA-568-C.2: category 6 (1-250 MHz) specifications

 

 

 

ISO/IEC 11801 2nd Ed.: category 6 (1-250 MHz) specifications

Cordage

 

 

Jacket diameter: < 6.35 mm (0.25 in)

 

 

 

Construction: 4 pairs, 7 strands 26 AWG, UTP,

 

 

 

high density polyethylene insulation,

 

 

 

fire retardant PVC compound jacket

Wiring Scheme

 

 

ANSI/TIA/EIA-568-C.2: T568A & T568B

 

 

 

ISO/IEC 11801 2nd Ed.: 8-position conductor/pair assignment (1-2/3-6/4-5/7-8)

Physical Characteristics

 

 

Retention: 50 N (11 lbf) for 60±5 s

 

 

 

Mating cycle life: min 750 cycles

 

 

 

Tensile strength: ≥ 20 N per wire

Electrical/Optical Characteristics

 

Insulation resistance: min 500 MOhm @ 100 Vdc

 

 

 

Dielectric withstanding voltage: 1,000 Vdc/ac peak contact to contact @ 60 Hz for 1

 

 

 

min

 

 

 

Contact resistance: max 20 Mohm

Environmental Characteristics

 

Storage: -40 °C-+70 °C (-40 °F-+158 °F)

 

 

 

Operation: -10 °C-+60 °C (+14 °F-+140 °F)

 

 

 

RH (operation): max non-condensing 93 %

Warranty

 

 

5-year limited component warranty

 

 

 

10-year Signamax Link/Channel Warranty

 

 

 

15-year Signamax Extended Component Warranty

 

 

 

25-year Signamax Cabling System Warranty

 

 

 

 

PRODUCT PARTS

 

 

-

C6C-114cc-xxFB

 

 

 

Replace cc: Color BK, BU, GY, WH, RD, YE

 

 

 

 

Replace xx: 3,7,10,15,20,25 ft

2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com