Detailed Specification & Technical Data
C6AS=314GY-xxFB
Category 6A F/UTP Assembly
PRODUCT OVERVIEW |
- |
Product Description |
Category 6A Screened Patch Cords w/Snag-Proof Boots |
Product Overview |
West Penn Connectivity Systems category 6A patch cords are designed to meet 10 Gigabit Ethernet IEEE 802.3an rev. 1.0 |
|
transmis-sion requirements, and are guaranteed to meet ANSI/TIA-568-C.2 channel performance. Cords are 100% transmis- |
|
sion tested and support category 6A 100-meter channel performance. Assembled in a controlled environment using advanced |
|
manufacturing tech-niques to insure consistent quality these patch cords provide reliable performance when mated with our |
|
category 6A connecting hardware and deliver supreme performance for network cabling systems. |
|
West Penn category 6A patch cords incorporate slim-profile snag-free boots, which protect the plug latch, and a flexible, but |
|
durable cable strain relief and are compatible with both T568A and T568B wiring schemes. Patch cords are manufactured us- |
|
ing ETL-verified 26-AWG stranded cable designed for greater flexibility and service life. |
Package Qty. |
1 |
PRODUCT FEATURES |
- |
Features |
• Designed to meet 10G IEEE 802.3an transmission requirements |
|
• Guaranteed to meet TIA-568-C.2 performance |
|
• 100% factory transmission tested per TIA-568-C.2 specifications |
|
• Support category 6A 100-meter channel performance |
|
• Screening provides 100 % protection against ANEXT |
|
• Rated for at least 750 plug insertions |
|
• T568A/B wiring scheme compatible |
|
• Contact design provides enhanced plug-to-jack connection integrity |
|
• Slim-profile snag-free boots with durable flexible cable strain relief |
|
• ETL verified 26 AWG stranded cable |
SPECIFICATIONS & DIMENSIONS |
- |
Transmission Performance |
ANSI/TIA-568-C.2: category 6A (1-500 MHz) specifications |
Cordage |
Jacket diameter: < 6.35 mm (0.25 in) |
|
Construction: 4 pairs, 7 strands 26 AWG, UTP, |
|
high density polyethylene insulation, |
|
fire retardant PVC compound jacket |
Wiring Scheme |
ANSI/TIA/EIA-568-C.2: T568A & T568B |
|
ISO/IEC 11801: 8-position conductor/pair assignment (1-2/3-6/4-5/7-8) |
Physical Characteristics |
Retention: 50 N (11 lbf) for 60±5 s |
|
Mating cycle life: min 750 cycles |
|
Tensile strength: ≥ 20 N per wire |
Electrical/Optical Characteristics |
Insulation resistance: min 500 MOhm @ 100 Vdc |
|
Dielectric withstanding voltage: 1,000 Vdc/ac peak contact to contact @ 60 Hz for 1 min |
|
Contact resistance: max 20 Mohm |
Environmental Characteristics |
Storage: -40 °C-+70 °C (-40 °F-+158 °F) |
|
Operation: -10 °C-+60 °C (+14 °F-+140 °F) |
|
RH (operation): max non-condensing 93 % |
Warranty |
5-year limited component warranty |
|
10-year Signamax Link/Channel Warranty |
|
15-year Signamax Extended Component Warranty |
|
25-year Signamax Cabling System Warranty100BASE-T2, 1000BASE-T, 10GBASE-T |
PRODUCT PARTS |
- |
C6AS-314cc-xxFB |
Replace cc: Color GY |
|
Replace xx: 3,7,10,15,20,25 ft |
2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com