DE |
Ergänzende Betriebsanleitung |
|
|
|
|
|
|
||
|
|
|
||
GB |
Supplementary operating instructions |
|
|
|
ES |
Manual de instrucciones complementario |
|
|
|
FR |
Mode d'emploi complémentaire |
|
|
|
IT |
Istruzioni per l'uso integrative |
|
|
|
PT |
Manual complementar |
|
|
|
NL |
Aanvullende gebruiksaanwijzing |
|
|
|
SV |
Tilläggsbruksanvisning |
|
|
|
DK |
Supplerende betjeningsvejledning |
|
|
|
FI |
Täydentävä käyttöopas |
|
|
|
GR |
Συμπληρωματικές οδηγίες λειτουργίας |
WTHA 1 |
||
TR |
Tamamlayıcı kullanım kılavuzu |
|||
CZ |
Dodatečný návod k provozu |
|||
PL |
Uzupełniająca instrukcja obsługi |
|||
HU |
Kiegészítő üzemeltetési utasítás |
|||
SK |
Doplnkový návod na obsluhu |
|
|
|
SL |
Dodatna navodila za uporabo |
|
|
|
EE |
Lisakasutusjuhend |
|
|
|
LV |
Papildu lietošanas pamācība |
|
|
|
LT |
Eksploatacijos instrukcijos papildymas |
|
|
|
BG |
Допълнително Ръководство за работа |
|
|
|
RO |
Manualul de utilizare suplimentar |
|
|
|
HR |
Dodatne Upute za uporabu |
|
|
|
CN |
|
|
|
|
JP |
|
|
|
|
|
|
|
|
|
DE GB ES FR IT PT NL
SV DK FI GR
TR CZ PL HU SK SL
EE LT
LV BG
RO HR
CN
JP
Deutsch
English
Español
Français
Italiano
Portugues
Nederlands
Svenska
Dansk
Suomi
Ελληνικα
Türkçe
Český
Polski
Magyar
Slovensky
Slovenščina
Eesti
Latviski
Lietuviškai
Български
Român
Hrvatski
Menü | Zurücksetzen auf Werkseinstellungen | Fehlermeldungen und Fehlerbehebung | Luftmenge
Menu | Resetting to factory settings | Error messages and error clearance | Air flow
Menú | Restaurar la configuración de fábrica | Mensajes de error y su reparación | Air flow
Menu | Réinitialisation aux réglages d‘usine |Messages d‘erreur et élimination des défauts| Air flow
Menu | Ripristino impostazioni di fabbrica | Messaggi d‘errore e problemi | Flusso dell‘aria
Menu | Reposição dos ajustes de fábrica | Avisos de erro e eliminação de falhas | Fluxo deAr
Menu | Resetten naar fabrieksinstellingen | Foutmeldingen en verhelpen van fouten |
Luchthoeveelheid
Meny | Återställa till fabriksinställningarna | Felmeddelanden och åtgärder | Luftflöde
Menu | Nulstilling til fabriksindstillinger | Fejlmeldinger og fejlafhjælpning | Air flow
Valikko | Palauttaminen tehdasasetuksiin | Vikailmoitukset ja vikojen korjaaminen | Ilmavirta
Μενού | Επαναφορά στις ρυθμίσεις του εργοστασίου | Μηνύματα και άρση σφαλμάτων |
Ποσότητα αέρα
Menü | Fabrika ayarlarına geri alma | Hata mesajları ve hata giderme | Air flow
Menu | Nastavení na výchozí hodnoty | Chybová hlášení a odstraňování chyb | Průtok
Menu | Resetowanie do nastawy fabrycznej | Komunikaty o błędach i usuwanie błędów | Air flow
Menü | Visszaállítás a gyári beállításokra | Hibaüzenetek és hibaelhárítás | Air flow
Ponuka | Obnovenie výrobných nastavení | Chybové hlásenia a odstraňovanie chýb |
Množstvo vzduchu
Meni | Ponastavitev na tovarniške nastavitve | Sporočila o napakah in odpravljanje napak |
Pretok zraka
Menüü | Tehaseseadete taastamine | Veateated ja vigade kõrvaldamine | Õhu kogus
Izvēlne | Atiestatīšana uz rūpnīcas iestatījumiem |
Paziņojumi par traucējumiem un traucējumu novēršana | Gaisa plūsmas apjoms
Meniu | Gamyklinių nustatymų atstata | Pranešimai apie gedimus ir jų šalinimas | Oro kiekis
Меню | Возвращение к заводским установкам |
Съобщения за неизправности и отстраняване | Количество въздух
Meniul | Resetare fabrică | Mesaje de defecțiune și remedierea defecțiunilor | Cantitatea de aer
Izbornik | Vraćanje na tvorničke postavke | Dojave o nepravilnostima i uklanjanje nepravilnosti |
Količina zraka
| | |
| | |
3
10
17
24
31
38
45
52
59
66
73
80
87
94
101
108
115
122
129
136
143
150
157
164
171
DEUTSCH DE
Menü 1
Durch betätigen der Menütastegelangen Sie in das Menü 1
Standby Temperatur
Die Standby Temperatur ist ein voreinstellbarer Wert auf den der Heißluftkolben bei Nichtbenutzung geregelt wird.
Option |
|
Beschreibung |
OFF |
|
Standby deaktiviert (OFF) |
100-300 |
°C |
Standby Temperatur, individuell einstellbar |
200-600 |
°F |
|
Standby Zeit (Temperaturabschaltung)
Der Heißluftkolben, wird bei Nichtbenutzung nach der voreingestellten Standby Zeit auf die Standby
Temperatur geregelt.
Drücken der Taste am Heißluftkolben (oder Fußschalter) beendet den Standby Zustand.
Option |
Beschreibung |
OFF |
Standby deaktiviert (Werkseinstellung OFF) |
1-99 min |
Standby Zeit, individuell einstellbar |
OFF Zeit
Bei Nichtgebrauch wird nachAblauf der OFF Zeit der Heißluftkolben deaktiviert. Die Temperaturabschaltung wird unabhängig von der eingestellten Standby-Funktion ausgeführt. Die Isttemperatur wird blinkend angezeigt und dient als Restwärmeanzeige. Im Display erscheint „AUTO-OFF“.
Solange der Heißluftkolben abkühlt wird die Restwärme angezeigt. Zusätzlich blinkt „Cooling“ im Display.
Sobald die Temperatur 50°C (122°F) unterschreitet, zeigt das Display OFF an und die Hintergrundbeleuchtung wird deaktiviert.
Gleichzeitiges Drücken der UP und DOWN Taste aktiviert das Gerät.
Option |
Beschreibung |
OFF |
OFF Zeit deaktiviert (Werkseinstellung 5 min) |
1-999 min |
OFF Zeit, individuell einstellbar |
3
DEUTSCH DE
Window-Funktion
Option 1 (Werkseinstellung):
Fußschalter Funktion auf FS ON stellen.
Einschränkung des Einstellbereichs auf ± 1-99 °C (±1-180 °F) ausgehend von einer durch die „LOCK“ Funktion verriegelten Temperatur.
Die verriegelte Temperatur stellt somit die Mitte des einstellbaren Temperaturfensters dar.
Option 2:
Fußschalter Funktion FS OFF stellen.
Ausgehend von einer eingestellten, verriegelten Temperatur kann mit Hilfe der WINDOW-Funktion ein Temperaturfenster von ± 1-99 °C (±1-180 °F) eingestellt werden. Liegt die Ist-Temperatur innerhalb dieses Fensters, wird der potentialfreie Kontakt (Optokopplerausgang) durchgeschaltet.
Option |
Beschreibung |
OFF |
Window-Funktion deaktiviert (Werkseinstellung OFF) |
1-99 °C |
Window-Funktion, individuell einstellbar |
1-180 °F |
|
LOCK
Verriegelung der Station. Nach dem Verriegeln sind am Gerät keine Einstellungsänderungen mehr möglich.
Ausnahme 1: Window-Funktion Option 1.
Ausnahme 2: Siehe Menüpunkt PROFIL
Alle anderen Einstellungen können bis zur Entriegelung nicht mehr verstellt werden.
Station verriegeln
Den gewünschten dreistelligen Verriegelungscode (zwischen 001-999) einstellen und mit der Menütaste bestätigen.
Die Verriegelung ist aktiv (im Display ist ein Schloss zu sehen).
Station entriegeln
Menütaste drücken. Im Display erscheint ON
Den dreistelligen Verriegelungscode einstellen.
Code mit der Menütaste bestätigen.
Code vergessen?
Wenden Sie sich bitte an unseren Kunden Service: technical-ser- vice@weller-tools.com
4
DEUTSCH DE
Offset
Die tatsächliche Heißlufttemperatur kann durch Eingabe eines Temperatur-Offsets um ± 40 °C (± 72 °F) angepasst werden.
°C °F
Umschalten der Temperatureinheit.
Option Beschreibung
°C Celsius
°F Fahrenheit
Profil
Im diesem Menüpunkt können bis zu 5 Parametersätze aktiviert und eingestellt, sowie derAutomatischeAblauf der einzelnen Schritte (Reflowprofil) aktiviert werden.
Je Parametersatz sind Temperatur, Luftmenge und Zeit individuell einstellbar.
Ein Reflowprofil kann individuell aus den einzelnen Parametersätzen 1 – 5 aufsteigend konfiguriert werden.
Eingestelltes Reflowprofil kann abgespielt werden: z. B. 1 und 3 und 5
Eingestellte Parametersätze können gewechselt werden: z. B. 2 und 4 und 5 (ohneAutomatik Symbol oder Profil )
Reflowprofile und Parametersätze können im Hauptbildschirm mit der Taste Exit an und ausgeschaltet werden.
Ist derAutomatischeAblauf deaktiviert, können mit den Tasten UP und DOWN die einzelnen Parametersätze ausgewählt werden.
Reflowprofile und Parametersätze können mit der TasteAir und dem Fingerschalter (Fußschalter) gestartet und gestoppt werden.
Ist LOCK aktiviert kann nur das Reflowprofil bzw. die aktivierten Parametersätze ausgewählt und gestartet werden.
5
DEUTSCH DE
Menü 2
Durch langes betätigen (3 sec) der Menütaste gelangen Sie in das Menü 2
Option |
Beschreibung |
ON |
Festtemperaturen aktiviert |
OFF |
Festtemperaturen deaktiviert (Werkseinstellung) |
Einstellung Tastenfunktionen
Umschalten der Funktionsweise derAir / UP und Down Tasten.
Option |
|
Beschreibung |
ONAir |
|
Start/Stop Heißluft mitAir Taste (im Profilmodus immer aktiv) |
|
|
Auswahl der Luftmenge über down Taste |
|
|
Auswahl Temperatur über UP Taste |
OFFAir |
|
Air Taste = Luftmengeneinstellung |
Hintergrundbeleuchtung |
||
Option |
|
Beschreibung |
|
||
0-100% |
|
LCD-Helligkeit |
Potentialfreier Schaltausgang
Anwahl von Zero SmogAusgang oder Roboterausgang
Option |
Beschreibung |
FS ON |
Fußschalterfunktion & Zero SmogAusgang aktiviert |
FS OFF |
RS232 & Roboterausgang aktiviert (Werkseinstellung) |
6
DEUTSCH DE
Beispiel
Konfiguration ZeroSmog Ausgang
2 |
1 |
3
7
DEUTSCH DE
Zurücksetzen auf Werkseinstellungen
|
+ |
|
|
3 |
|
|
|
|
|
|
sec |
|
|
|
|
Beim Einschalten: Exit, UP und DOWN bis ein Tonsignal ertönt |
|
|
|
||||
|
|
|
|
|
|||
Fehlermeldungen und Fehlerbehebung |
|
|
|
||||
Meldung/Symptom |
|
Mogliche Ursache |
|
Maßnahmen zur Abhilfe |
|||
|
|
||||||
|
|
|
|
|
|
|
|
• |
Keine Displayfunktion |
|
• |
Keine Netzspannung vorhanden |
|
• |
Netzschalter einschalten |
|
(Display aus) |
|
|
|
|
• |
Netzspannung uberprufen |
|
|
|
|
|
|
• |
Geratesicherung uberprufen |
• |
OFF |
|
• |
Station befindet sich im Standby oder |
|
• |
Mit den Tasten UP oder Down Lötwerk- |
|
|
|
|
OFF Modus |
|
|
zeug wieder aktivieren |
• |
Werkzeug bleibt kalt |
|
• |
Station befindet sich im Standby oder |
|
• |
Finger oder Fußschalter betätigen |
|
|
|
|
OFF Modus |
|
• |
Netzversorgung prüfen |
|
|
|
• |
Netzspannungsstörung |
|
|
|
• |
Station funktioniert nicht wie |
|
• |
Parameter verstellt |
|
• |
Station Zurücksetzen auf Werkseinstellun- |
|
gewohnt |
|
|
|
|
|
gen |
• |
Einstellungsänderungen nicht |
|
• |
Station verriegelt |
|
• |
Station entriegeln |
|
möglich |
|
|
|
|
|
|
• |
Heißluftmenge nicht |
|
• |
Schlauch beschädigt, geknickt oder |
|
• |
Gerät von Netzspannung trennen |
|
ausreichend |
|
|
verdreht |
|
• |
Schlauch prüfen |
|
|
|
|
|
|
• |
Gerät von Fachkraft Instandsetzen lassen |
• |
Zero Smog läuft nicht an |
|
• |
Keine Netzspannung vorhanden |
|
• |
Netzversorgung prüfen |
|
|
|
• |
Kein Signal vorhanden |
|
• |
Schnittstellenverkabelung prüfen |
|
|
|
|
|
|
• |
Einstellungen Schnittstelle prüfen |
• |
Err 1 |
|
• |
Falsche Netzspannung |
|
• |
Netzspannung uberprufen |
• |
Err 2 |
|
• |
Heizpatrone defekt |
|
• |
Heizpatrone von Fachpersonal wechseln |
8
DEUTSCH DE
Luftmenge
Air Volume [l/min]
<![endif]>Air Volume [l/min]
120 |
|
|
|
|
|
|
|
|
|
110 |
|
|
|
|
|
|
|
|
|
100 |
|
|
|
|
|
|
|
|
|
90 |
|
|
|
|
|
|
|
|
|
80 |
|
|
|
|
|
|
|
|
|
70 |
|
|
|
|
|
|
|
|
TNR120 |
|
|
|
|
|
|
|
|
|
TNR70 |
60 |
|
|
|
|
|
|
|
|
TNRB60 |
|
|
|
|
|
|
|
|
|
|
50 |
|
|
|
|
|
|
|
|
TNR40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TNR25 |
40 |
|
|
|
|
|
|
|
|
TNRB17 |
|
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
WTHA 1 230 V - @ 300°C |
|
|
|
|
|
|
|
|
|
|
|
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
Turbine Speed [%]
9
ENGLISH GB
Menu 1
Pressing the Menu button takes you to menu 1
Standby Temp.
The standby temperature is a preset value to which the hot air gun is adjusted when not in use.
Option |
|
Description |
OFF |
|
Standby deactivated (OFF) |
100-300 |
°C |
Standby Temp., Individually adjustable |
200-600 |
°F |
|
Standby time (temperature deactivation)
If the hot air gun is not in use, it is adjusted to the standby temperature after the preset standby time. Pressing the button on the hot air gun (or foot-operated switch) exits standby mode.
Option |
Description |
OFF |
Standby deactivated (factory setting OFF) |
1-99 min |
Standby Time, Individually adjustable |
OFF time
If the hot air gun is not used, it is deactivated after the OFF time elapses. Temperature deactivation is performed independently of the set standby function. The actual temperature is indicated by flashing LED and serves as a residual heat display. The display reads „OFF“.
While the hot air gun cools, the residual heat is displayed. „Cooling“ also flashes in the display.
As soon as the temperature falls below 50 °C (122 °F), OFF appears in the display and the backlighting is deactivated.
Pressing the UP and DOWN buttons at the same time activates the device.
Option |
Description |
OFF |
OFF time Deactivated (factory setting 5 min) |
1-999 min |
OFF time, Individually adjustable |
10
ENGLISH GB
Window function
Option 1 (factory setting):
Set the foot-operated switch function to FS ON.
Limiting the adjustment range to ± 1-99 °C (±1-180 °F) based on a temperature locked using the „LOCK“ function.
The locked temperature therefore represents the middle of the adjustable temperature window.
Option 2:
Set the foot-operated switch function to FS OFF.
Starting from a set, locked temperature, it is possible to set a temperature window of ± 1-99 °C (±1- 180 °F) using the WINDOW function. If the actual temperature is within this window, the potential-free contact (optocoupler output) becomes conductive.
Option |
Description |
OFF |
Window function Deactivated (factory setting OFF) |
1-99 °C |
Window function, Individually adjustable |
1-180 °F |
|
LOCK
Lock for the station.After the station is locked, it is no longer possible to change any device settings. Exception 1: Window function Option 1.
Exception 2: See the PROFILE menu item
All other settings are disabled until the station is unlocked again.
Locking the station
Set the three-digit locking code of your choice (between 001 and 999) and confirm by pressing the
Menu button.
The lock is active (the display shows a lock symbol).
Unlocking the station
Press the Menu button. ON appears in the display Set the three-digit locking code.
Press the Menu button to confirm the code.
Forgotten code?
Please contact our Customer Service: technical-service@weller- tools.com
11
ENGLISH GB
Offset
The actual hot air temperature can be adapted by entering a temperature offset of around ± 40 °C (± 72 °F).
°C °F
Changing over the temperature unit.
Option Description
°C Celsius
°F Fahrenheit
Profile
This menu item allows up to five parameter sets to be activated and adjusted and the automatic sequence of the individual steps (reflow profile) to be activated.
Depending on the parameter set, the temperature, air quantity and time can be adjusted individually.
Areflow profile can be individually configured in a cumulative manner from the individual parameter sets 1 – 5.
The set reflow profile can be implemented:
E.g. 1 and 3 and 5
The set parameter sets can be changed:
E.g. 2 and 4 and 5 (Without automatic symbol or profile )
Reflow profiles and parameter sets can be switched on and off in the main screen using the Exit button.
If the automatic sequence is deactivated, the UP and DOWN buttons can be used to select the individual parameter sets.
Reflow profiles and parameter sets can be started and stopped with theAir button and the finger-operated switch (foot-operated switch).
If LOCK is activated, only the reflow profile or the activated parameter sets can be selected and started.
12
ENGLISH GB
Menu 2
Pressing and holding the Menu button (three seconds) takes you to menu 2
Option |
Description |
ON |
Fixed temperaturesActivated |
OFF |
Fixed temperatures Deactivated (factory setting) |
Setting the button functions
Changing over the operating mode of theAir/UP and DOWN buttons.
Option |
Description |
ONAir |
Start/stop hot air with theAir button (Always active in profile mode) |
|
Selecting the air quantity using the DOWN button |
|
Selecting the temperature using the UP button |
OFFAir |
Air button = Setting the air quantity |
Backlighting |
|
|
Option |
|
Description |
|
||
0-100% |
|
LCD-Brightness |
Floating switching output
Selection of Zero-Smog output or robot output
Option |
Description |
FS ON |
Foot-operated switch function & Zero-Smog output activated |
FS OFF |
RS232 & Robot output activated (factory setting) |
13
ENGLISH GB
Example
Zero-Smog output configuration
2 |
1 |
3
14
ENGLISH GB
Resetting to factory settings
|
+ |
|
|
3 |
|
|
|
|
|
|
sec |
|
|
|
|
When switching on: Exit, UP and DOWN until a signal sounds |
|
|
|
||||
|
|
|
|
|
|||
Error messages and error clearance |
|
|
|
||||
Message/symptom |
|
Possible cause |
|
Remedial measures |
|||
|
|
||||||
|
|
|
|
|
|
|
|
• |
No display function (display |
|
• |
No mains supply voltage |
|
• |
Turn on mains power switch |
|
OFF) |
|
|
|
|
• |
Check mains supply voltage |
|
|
|
|
|
|
• |
Check device fuse |
• |
OFF |
|
• |
Station is on standby or in OFF mode |
|
• |
Reactive the soldering tool using the UP |
|
|
|
|
|
|
|
or DOWN buttons |
• |
Tool remains cold |
|
• |
Station is on standby or in OFF mode |
|
• |
Press the finger-operated switch or |
|
|
|
• |
Mains voltage fault |
|
|
foot-operated switch |
|
|
|
|
|
|
• |
Check the mains power supply |
• |
Station is not operating as it |
|
• |
Parameters set incorrectly |
|
• |
Reset the station to the factory settings |
|
usually does |
|
|
|
|
|
|
• |
Settings cannot be changed |
|
• |
Station locked |
|
• |
Unlocking the station |
• |
Insufficient quantity of hot air |
|
• |
Hose damaged, kinked or twisted |
|
• |
Disconnect the device from the mains |
|
|
|
|
|
|
|
voltage |
|
|
|
|
|
|
• |
Check the hose |
|
|
|
|
|
|
• |
Have the device repaired by a specialist |
• |
Zero Smog is not running |
|
• |
No mains supply voltage |
|
• |
Check the mains power supply |
|
|
|
• |
No signal detected |
|
• |
Check the interface wiring |
|
|
|
|
|
|
• |
Check the interface settings |
• |
Err 1 |
|
• |
Incorrect mains voltage |
|
• |
Check mains supply voltage |
• |
Err 2 |
|
• |
Heating cartridge defective |
|
• |
Have the heating cartridge replaced a |
|
|
|
|
|
|
|
specialist |
15
ENGLISH GB
Air flow
Air Volume [l/min]
<![endif]>Air Volume [l/min]
120 |
|
|
|
|
|
|
|
|
|
110 |
|
|
|
|
|
|
|
|
|
100 |
|
|
|
|
|
|
|
|
|
90 |
|
|
|
|
|
|
|
|
|
80 |
|
|
|
|
|
|
|
|
|
70 |
|
|
|
|
|
|
|
|
TNR120 |
|
|
|
|
|
|
|
|
|
TNR70 |
60 |
|
|
|
|
|
|
|
|
TNRB60 |
|
|
|
|
|
|
|
|
|
|
50 |
|
|
|
|
|
|
|
|
TNR40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TNR25 |
40 |
|
|
|
|
|
|
|
|
TNRB17 |
|
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
WTHA 1 230 V - @ 300°C |
|
|
|
|
|
|
|
|
|
|
|
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
Turbine Speed [%]
16
ESPAÑOL ES
Menú 1
Al pulsar en la tecla de menú, se accede al menú 1
Temp. standby
La temperatura Standby es un valor predeterminado en el cual se regula un soldador de aire caliente cuando no se utiliza.
Opcional |
Descripción |
|
OFF |
|
Standby desactivado (OFF) |
100-300 |
°C |
Temp. standby, ajuste individual |
200-600 |
°F |
|
Tiempo standby (desconexión de la temperatura)
El soldador de aire caliente se regula a la temperatura Standby si no se utiliza durante el tiempo de espera predeterminado.
Al pulsar la tecla en el soldador de aire caliente (o el interruptor de pedal), se finaliza el estado
Standby.
Opcional |
Descripción |
OFF |
Standby desactivado (configuración de fábrica OFF) |
1-99 min |
Tiempo standby, ajuste individual |
Tiempo de desconexión (tiempo OFF)
Cuando no se utiliza, se desactiva el soldador de aire caliente una vez transcurrido el tiempo OFF. La desconexión de temperatura se realiza independientemente de la función standby ajustada. La temperatura real parpadea y sirve para indicar el calor residual. Mientras aparece en la pantalla
„AUTO-OFF“.
Mientras se enfría el soldador de aire caliente, se indica el calor residual. Además, en la pantalla parpadea la palabra «Cooling».
En cuanto la temperatura es inferior a 50 °C (122 °F), en la pantalla aparece «OFF» y se desactiva la iluminación de fondo.
Al pulsar las teclas UP y DOWN de forma simultánea, se activa la herramienta.
Opcional |
Descripción |
OFF |
Tiempo de desconexión (tiempo OFF) desactivado (configuración de fábrica 5 min) |
1-999 min |
Tiempo de desconexión (tiempo OFF), ajuste individual |
17
ESPAÑOL ES
Función Window
Opcional 1 (configuración de fábrica):
Ajustar la función del interruptor de pedal a «FS ON».
Limitación del rango de ajuste a ±1-99 °C (±1-180 °F) a partir de una temperatura bloqueada con la función «LOCK».
Por tanto la temperatura bloqueada representa el centro del rango térmico ajustable.
Opcional 2:
Ajustar la función de interruptor de pedal a «FS OFF».
Partiendo de una temperatura ajustada y bloqueada es posible ajustar una ventana de temperatura de aproximadamente ±1-99 °C (±1-180 °F) con la ayuda de la función WINDOW. Si la temperatura real está dentro de este margen, el contacto sin potencial (salida del optoacoplador) estará conectado.
Opcional |
Descripción |
OFF |
Función Window desactivado (configuración de fábrica OFF) |
1-99 °C |
Función Window, ajuste individual |
1-180 °F |
|
LOCK
Bloqueo de la estación. Cuando se bloquea el aparato, ya no se pueden cambiar los ajustes. Excepción 1: Función Window Opcional 1.
Excepción 2: Véase el punto del menú PERFIL
No es posible cambiar ninguno de los demás ajustes hasta que se desbloquee.
Bloquear estación
Ajustar el código de bloqueo deseado con tres dígitos (comprendidos entre 001 y 999) y confirmar mediante la tecla del menú.
El bloqueo está activado (en la pantalla aparecerá un candado).
Desbloquear la estación
Pulsar la tecla de menú. En la pantalla, aparecerá «ON» Ajustar el código de bloqueo de tres dígitos.
Confirmar el código con la tecla de menú.
¿Ha olvidado el código?
Por favor, diríjase a nuestro servicio técnico: technical-service@ weller-tools.com
18
ESPAÑOL ES
Offset
La temperatura real del aire caliente se puede ajustar introduciendo una compensación de temperatura de aproximadamente ±40 °C (±72 °F).
°C °F
Cambiar la unidad de temperatura.
Opcional |
Descripción |
°C |
Grados centígrados |
°F |
Fahrenheit |
Perfil
En este punto del menú, se pueden activar y ajustar hasta 5 grupos de parámetros, así como la secuencia automática de los pasos individuales (perfil de reflujo).
Los grupos de parámetros de temperatura, cantidad de aire y tiempo se pueden ajustar individualmente.
Es posible configurar un perfil de reflujo (Reflowprofil) de forma ascendente y personalizada a partir de los grupos de parámetro individuales 1-5.
Se puede ejecutar el perfil de reflujo ajustado: p. ej., 1 y 3 y 5
Se pueden cambiar los grupos de parámetros ajustados: p. ej., 2 y 4 y 5 (sin símbolo automático o perfil )
Los perfiles de reflujo y los grupos de parámetros se pueden conectar y desconectar en la pantalla principal con la tecla Exit (salir).
Si la secuencia automática está desactivada, se pueden seleccionar los grupos de parámetros uno por uno con las teclas UP y DOWN.
Los perfiles de reflujo y los grupos de parámetros se pueden iniciar y parar con la teclaAir y el interruptor de dedo (o interruptor de pedal).
Si LOCK está activado, solo se puede seleccionar e iniciar el perfil de reflujo o los grupos de parámetros activados.
19
ESPAÑOL ES
Menú 2
Al pulsar de forma prolongada (3 segundos) la tecla del menú, se accede al menú 2
Opcional |
Descripción |
ON |
Temperaturas fijas activado |
OFF |
Temperaturas fijas desactivado (configuración de fábrica) |
Ajuste de las funciones de las teclas
Cambiar el modo de funcionamiento de las teclasAir / UP y Down.
Opcional |
Descripción |
ONAir |
Iniciar o detener el aire caliente con la teclaAir (siempre activo en el modo Perfil) |
|
Seleccionar la cantidad de aire con la tecla DOWN |
|
Seleccionar la temperatura con la tecla UP |
OFFAir |
Tecla Air = Ajuste de la cantidad de aire |
Iluminación del fondo
Opcional |
Descripción |
0-100% |
Brillo LCD |
Salida sin potencial
Seleccionar salida Zero Smog o la salida de robot
Opcional |
Descripción |
FS ON |
Función de interruptor de pedal & Salida Zero Smog activada |
FS OFF |
RS232 & Salida de robot activada (configuración de fábrica) |
20
ESPAÑOL ES
Ejemplo
Configuración de salida Zero Smog
2 |
1 |
3
21
ESPAÑOL ES
Restaurar la configuración de fábrica
|
+ |
|
|
3 |
|
|
|
|
|
|
sec |
|
|
|
|
Al conectar: Exit, UP y DOWN hasta que suene un pitido |
|
|
|
||||
|
|
|
|
|
|||
Mensajes de error y su reparacion |
|
|
|
||||
Mensaje/Síntoma |
|
Causa posible |
|
Reparacion |
|||
|
|
||||||
|
|
|
|
|
|
|
|
• |
Sin funcion de pantalla |
|
• |
No hay tension de red disponible |
|
• |
Conectar el interruptor principal |
|
(pantalla desconectada) |
|
|
|
|
• |
Comprobar la tension de red |
|
|
|
|
|
|
• |
Comprobar el fusible del aparato |
• |
OFF |
|
• |
La estación se encuentra en Standby o en |
|
• |
Activar de nuevo la herramienta de |
|
|
|
|
modo OFF |
|
|
soldadura con las teclas UP o Down |
• |
La herramienta se mantiene |
|
• |
La estación se encuentra en Standby o en |
|
• |
Pulsar el interruptor de dedo o de pedal |
|
fría |
|
|
modo OFF |
|
• |
Comprobar la alimentación de red |
|
|
|
• |
Fallo de la tensión de red |
|
|
|
• |
La estación no funciona de la |
|
• |
Parámetros ajustados |
|
• |
Restablecer la estación a los ajustes de |
|
manera habitual |
|
|
|
|
|
fábrica |
• |
No se pueden cambiar los |
|
• |
Estación bloqueada |
|
• |
Desbloquear la estación |
|
ajustes |
|
|
|
|
|
|
• |
Cantidad insuficiente de aire |
|
• |
Tubo dañado, doblado o retorcido |
|
• |
Desconectar el aparato de la tensión de |
|
caliente |
|
|
|
|
|
red |
|
|
|
|
|
|
• |
Comprobar el tubo |
|
|
|
|
|
|
• |
Encargar la reparación del aparato a un |
|
|
|
|
|
|
|
especialista |
• |
Zero Smog no arranca |
|
• |
No hay tension de red disponible |
|
• |
Comprobar la alimentación de red |
|
|
|
• |
No hay señal disponible |
|
• |
Comprobar el cableado de la interfaz |
|
|
|
|
|
|
• |
Comprobar los ajustes de la interfaz |
• |
Err 1 |
|
• |
Tensión de red incorrecta |
|
• |
Comprobar la tension de red |
• |
Err 2 |
|
• |
Cartucho calefactor defectuoso |
|
• |
Encargar el cambio del cartucho |
|
|
|
|
|
|
|
calefactor a personal especializado |
22
ESPAÑOL ES
Air flow
Air Volume [l/min]
<![endif]>Air Volume [l/min]
120 |
|
|
|
|
|
|
|
|
|
110 |
|
|
|
|
|
|
|
|
|
100 |
|
|
|
|
|
|
|
|
|
90 |
|
|
|
|
|
|
|
|
|
80 |
|
|
|
|
|
|
|
|
|
70 |
|
|
|
|
|
|
|
|
TNR120 |
|
|
|
|
|
|
|
|
|
TNR70 |
60 |
|
|
|
|
|
|
|
|
TNRB60 |
|
|
|
|
|
|
|
|
|
|
50 |
|
|
|
|
|
|
|
|
TNR40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TNR25 |
40 |
|
|
|
|
|
|
|
|
TNRB17 |
|
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
WTHA 1 230 V - @ 300°C |
|
|
|
|
|
|
|
|
|
|
|
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
Turbine Speed [%]
23
FRANÇAIS FR
Menu 1
Vous pouvez accéder au menu 1 en actionnant la touche de menu
Temp. Stand-by
La température de veille est une valeur prédéterminable sur laquelle le fer à air chaud est réglé en cas de non-utilisation.
Option |
|
Description |
OFF |
|
État de veille désactivé (OFF) |
100-300 |
°C |
Temp. Stand-by, réglable individuellement |
200-600 |
°F |
|
Durée de mise en veille (désactivation de la température)
Le fer à air chaud est réglé sur la température de veille en cas de non-utilisation après écoulement du temps de veille prédéfini.
Une pression de la touche correspondante sur le fer à air chaud (ou commande au pied) permet d’arrêter l’état de veille.
Option |
Description |
OFF |
État de veille désactivé (réglage usine OFF) |
1-99 min |
Temps. Stand-by, réglable individuellement |
Temps OFF
En cas de non-utilisation, le fer à air chaud est désactivé après écoulement du temps OFF. La désactivation de la température s‘effectue indépendamment de la fonction de veille réglée. La température réelle est affichée de façon clignotante et sert d‘affichage de chaleur résiduelle. „AUTO-OFF“ apparaît à l‘affichage.
La chaleur résiduelle est affichée tant que le fer à air chaud se refroidit.
En outre, l’affichage « Cooling » (« Refroidissement ») clignote sur l’écran.
Dès que la température descend au-dessous de 50 °C (122 °F), l’écran affiche OFF et le rétroéclairage est désactivé.
Une pression simultanée des touches UP et DOWN permet d‘activer l’outil.
Option |
Description |
OFF |
Temps OFF désactivé (réglage usine 5 min) |
1-999 min |
Temps OFF, réglable individuellement |
24
FRANÇAIS FR
Fonction Window Option 1 (réglage usine):
Régler la fonction de commande au pied sur FS ON.
Limitation de la plage de réglage à ± 1-99 °C (±1-180 °F) en partant d’une température verrouillée grâce à la fonction « LOCK ».
La température verrouillée se situe ainsi au milieu de la fenêtre de température réglable.
Option 2:
Régler la fonction de commande au pied sur FS OFF.
En partant d‘une température réglée et verrouillée, la fonction WINDOW permet de régler une fenêtre de température de ± 1 -99 °C (±1 -180 °F). Si la température réelle se situe dans ladite fenêtre, le contact libre de potentiel (sortie sur opto-coupleur) est commuté.
Option |
Description |
OFF |
Fonction Window désactivé (réglage usine OFF) |
1-99 °C |
Fonction Window, réglable individuellement |
1-180 °F |
|
LOCK
Verrouillage de la station.Aucune modification de réglage n’est possible sur l’outil après verrouillage. Exception 1: Fonction Window Option 1.
Exception 2: Voir l‘option de menu PROFIL
Tous les autres réglages ne peuvent plus être modifiés jusqu‘au déverrouillage.
Verrouiller la station
Régler le code de verrouillage à trois chiffres souhaité (entre 001-999) et le valider à l’aide de la touche de menu.
Le verrouillage est actif (un cadenas est visible à l‘affichage).
Déverrouiller la station
Appuyer sur la touche de menu. L‘affichage ON apparaît sur l‘écran Régler le code de verrouillage à trois chiffres.
Valider le code à l’aide de la touche de menu.
Code oublié ?
Veuillez vous adresser à notre service client : technical-service@ weller-tools.com
25
FRANÇAIS FR
Offset
La température réelle de l‘air chaud peut être adaptée en entrant un décalage de température (offset) de ± 40 °C (± 72 °F).
°C °F
Commutation de l‘unité de température.
Option Description
°C Celsius
°F Fahrenheit
Profil
5 jeux de paramètres peuvent être activés et réglés grâce à cette option de menu, qui permet également l‘activation du déroulement automatique des différentes étapes (profil de refusion).
Pour chaque jeu de paramètres, la température, le débit d‘air et le temps peuvent être réglés individuellement.
Un profil de refusion peut être configuré individuellement par ordre croissant à partir des différents jeux de paramètres 1 – 5.
Le défilement du profil de refusion réglé peut être effectué : p. ex. 1, 3 et 5
Les jeux de paramètres réglés peuvent être changés : p. ex. 2, 4 et 5 (sans symbole automatique ni profil )
Les profils de refusion et les jeux de paramètres peuvent être activés et désactivés sur l‘écran principal grâce à la touche Exit.
Lorsque le déroulement automatique est désactivé, les différents jeux de paramètres peuvent être sélectionnés à l‘aide des touches UP et DOWN.
Les profils de refusion et les jeux de paramètres peuvent être démarrés et arrêtés au moyen de la toucheAir et de l‘interrupteur à doigt (commande au pied).
Lorsque la fonction LOCK est activée, seuls les profils de refusion et les jeux de paramètres activés peuvent être sélectionnés et démarrés.
26
FRANÇAIS FR
Menu 2
Une pression prolongée (3 secondes) sur la touche de menu vous permet d‘accéder au menu 2
Option |
Description |
ON |
Températures fixes activé |
OFF |
Températures fixes désactivé (réglage usine) |
Réglage des fonctions des touches
Commutation du fonctionnement des touchesAir / UP et DOWN.
Option |
Description |
ONAir |
Start/Stop air chaud avec la toucheAir (toujours actif en mode profil) |
|
Sélection du débit d‘air avec la touche DOWN |
|
Sélection de la température avec la touche UP |
OFFAir |
ToucheAir = Réglage du débit d‘air |
Rétroéclairage
Option |
Description |
0-100% |
Luminosité LCD |
Sortie de commutation libre de potentiel
Sélection de la sortie Zero Smog ou sortie robot
Option |
Description |
FS ON |
Fonction de commande au pied & Sortie Zero Smog activée |
FS OFF |
RS232 & Sortie robot activée (réglage usine) |
27
FRANÇAIS FR
Exemple
Configuration de la sortie Zero Smog
2 |
1 |
3
28
FRANÇAIS FR
Réinitialisation aux réglages d‘usine
+ |
3 |
sec |
Lors de la mise sous tension :Appuyer sur les touches Exit, UP et DOWN jusqu‘à ce qu‘un signal sonore se fasse entendre
Messages d‘erreur et elimination des defauts
Message / symptôme |
Cause possible |
Remède |
|||
• |
Pas de fonctionnement de |
• |
Pas de tension de reseau |
• |
Enclencher l‘interrupteur d‘alimentation |
|
l‘affichage (Afficheur eteint) |
|
|
• |
Contrôler la tension de reseau |
|
|
|
|
• |
Contrôler la protection de l‘appareil |
• |
OFF |
• |
Station en état de veille ou en mode OFF |
• |
Réactiver l‘outil de soudage à l‘aide des |
|
|
|
|
|
touches UP ou DOWN |
• |
L‘outil reste froid |
• |
Station en état de veille ou en mode OFF |
• |
Actionner la commande au pied ou |
|
|
• |
Défaut de la tension de réseau |
|
l‘interrupteur à doigt |
|
|
|
|
• |
Contrô̂ler l‘alimentation de réseau |
• |
La station ne fonctionne pas |
• |
Paramètres déréglés |
• |
Réinitialisation de la station aux réglages |
|
comme d‘habitude |
|
|
|
d‘usine |
• |
Modifications de réglage |
• |
Station verrouillée |
• |
Déverrouiller la station |
|
impossibles |
|
|
|
|
• |
Débit d‘air chaud insuffisant |
• |
Tuyau endommagé, plié ou tordu |
• |
Débrancher l‘outil de la tension de réseau |
|
|
|
|
• |
Contrô̂ler le tuyau |
|
|
|
|
• |
Faire réparer l‘outil par le personnel |
|
|
|
|
|
qualifié |
• |
Zero Smog ne démarre pas |
• |
Pas de tension de reseau |
• |
Contrô̂ler l‘alimentation de réseau |
|
|
• |
Aucun signal présent |
• |
Contrô̂ler le câblage d‘interface |
|
|
|
|
• |
Contrô̂ler le réglage d‘interface |
• |
Err 1 |
• |
Tension de réseau incorrecte |
• |
Contrôler la tension de reseau |
• |
Err 2 |
• |
Cartouche chauffante défectueuse |
• |
Faire remplacer la cartouche chauffante |
|
|
|
|
|
par le personnel qualifié |
29
FRANÇAIS FR
Air flow
Air Volume [l/min]
<![endif]>Air Volume [l/min]
120 |
|
|
|
|
|
|
|
|
|
110 |
|
|
|
|
|
|
|
|
|
100 |
|
|
|
|
|
|
|
|
|
90 |
|
|
|
|
|
|
|
|
|
80 |
|
|
|
|
|
|
|
|
|
70 |
|
|
|
|
|
|
|
|
TNR120 |
|
|
|
|
|
|
|
|
|
TNR70 |
60 |
|
|
|
|
|
|
|
|
TNRB60 |
|
|
|
|
|
|
|
|
|
|
50 |
|
|
|
|
|
|
|
|
TNR40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TNR25 |
40 |
|
|
|
|
|
|
|
|
TNRB17 |
|
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
WTHA 1 230 V - @ 300°C |
|
|
|
|
|
|
|
|
|
|
|
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
Turbine Speed [%]
30