W box technologies 0E-MAG600 User Manual

Page 1
Page 2
Magnetic Lock Wiring Instructions
A terminal block is provided for wiring the maglock to the power s
Set jumpers properly for 12VDC or 24VDC operation.
*(Cover all 4 pins =
Connect the ground lead from a DC power source to the (-) terminal.
Connect the positive lead from a DC power source to the (+) terminal.
12V - Cover 2,3 middle pins = 24V)
12VDC, 250mA @ 24VDC nominal
upply.
Magnetic Lock Installation Instructions
The magnet mounts to the door frame. The armature plate mounts to the door with hardware kit provided.
To remove the mounting plate from the magnet it is necessary to remove the two Phillips head screws on the left and right side on the face of the magnet.
Use supplied template and follow installation instructions with the door in its closed position.
Apply screw locking agent to all screws.
Filler Plate
Page 3
Armature Plate Hardware Installation Diagram
Armature plate must be mounted to door using the rubber washer sandwiched between the metal washers provided. Do not excessively tighten bolt. Armature must float on door. Screw locking agent should be used on each screw.
Care and Maintenance
Magnetic locks have no internal moving parts and require a minimum amount of maintenance. If a buildup of dirt or grime accumulates on the surface of the lock or armature plate it is recommended that they be wiped clean with a non-abrasive cloth.
The armature plate bolt and the hex head screws holding the magnet to header plate should be checked every three months to ensure a safe and secure installation.
Trouble Shooting Guide
Symptom Cause Solution
Incorr
ect input voltage Check voltage jumper position for
correct voltage setting
Low input voltage Check power supply voltage
Wire gauge incorrect for wire run
Misalignment of armature plate Armature plate must cover all
Insufficient holding force
Armature plate screwed tight to door Armature plate must rock on door to
Wrong hardware assembly A metal washer, rubber washer and
Door does not lock No power to door Check power directly at lock
magnetic poles of lock
align with lock
metal washer must be between door and armature plate