The 220 Digital Multimeter is warranted against any defects of material or workmanship
within a period of one (1) year following the date of purchase of the multimeter by the original
purchaser or original user.
Any multimeter claimed to be defective during the warranty period should be returned with
proof of purchase to an authorized Wavetek Meterman Service Center or to the local Wavetek
Meterman dealer or distributor where your multimeter was purchased. See maintenance
section for details.
Any implied warranties arising out of the sale of a W
but not limited to implied warranties of merchantability and fitness for a particular purpose, are
limited in duration to the above stated one (1) year period. W
liable for loss of use of the multimeter or other incidental or consequential damages,
expenses, or economical loss or for any claim or claims for such damage, expenses or
economical loss.
Some states do not allow limitations on how long implied warranties last or the exclusion
or limitation of incidental or consequential damages, so the above limitations or exclusions
may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
avetek Meterman multimeter, including
avetek Meterman shall not be
D GEWÄHRLEISTUNG
WARRANTY
Die Digitale Multimeter Modelle 220 ist ab Kaufdatum für ein (1) Jahr gegen Material- und
Herstellungsfehler gewährleistet. Siehe Kapitel "Unterhalt und Reparatur" für Einzelheiten.
Implizierte Schadeforderungen sind auch auf ein Jahr beschränkt. W
ansprechbar für Gebrauchsverluß oder Folgeschäden, Ausgaben, Gewinnverluß, usw
avetek Meterman ist nicht
.
E GARANTIA
Este Multímetro Digitale Modelo 220 está garantizado contra cualquier defecto de material
o de mano de obra durante un periodo de un (1) año contado a partir de la fecha de
adquisición. En la sección de "Mantenimiento y Reparación" se explican los detalles relativos
a reparaciones en garantía.
Cualquier otra garantía implícita está también limitada al periodo citado de un (1) año.
Wavetek Meterman no se hará responsable de pérdidas de uso del multí metro, ni de ningún
otro daño accidental o consecuencial, gastos o pérdidas económicas, en ninguna reclamación
a que pudiera haber lugar por dichos daños, gastos o pérdidas económicas.
F GARANTIE
Le multimètre digitaux, Modèle 220 est garanti pour un (1) an à partir de la date d’achat
contre les défauts de matériaux et de fabrication. Voir chapitre "Maintenance et Réparation"
pour plus de détails.
oute garantie impliquée est également limitée à un an. Wavetek Meterman ne peut être
T
tenu responsable pour perte d’utilisation ou autres préjudices indirects, frais, perte de
bénéfice, etc.
Maintenance et Réparation ................................ 36
SYMBOL DEFINITIONS
D • Erklärung der Symbole = E • Significado de los símbolos = F • Explication des Symboles
Direct current •D• Gleichstrom •E• Corriente continua
•F• Courant continu.
Alternating current •D• Wechselstrom •E• Corriente alterna
•F• Courant alternatif.
Ground connection •D• Erdanschluß •E• Conexión a tierra
•F• Connection de terre.
Attention! Refer to Operating Instructions •D• Achtung! Bitte Anleitung lesen •E•
¡Atención! Consulte las Instrucciones de Uso •F• Attention! Consultez le manuel.
Dangerous voltage may be present at terminals •D• Eine gefährliche Spannung kann an
den Eingängen anliegen •E• Puede haber tensión peligrosa en los terminales •F• Une
tension dangereuse peut être présente aux entrées.
Low battery symbol •D• Entladene Batterieanzeige •E• Símbolo de pila baja •F•
Symbole de pile déchargée.
This instrument has double insulation •D• Dieses Gerät ist doppelt geisoliert •E• Este
instrumento tiene doble aislamiento •F• Cet appareil est prévu d’une double isolation.
Logic Test HIGH and LOW indicators •D• Logik Test HIGH und LOW Indikatoren •E•
Indicadores lógicos de prueba Alto (High) y Bajo (Low). •F• Indicateurs de test logique
HIGH et LOW.
The digital multimeter 220 is a 3-3/4 digit, autoranging, AC-coupled, average
measuring & RMS reading instrument that measures voltage, current, resistance,
continuity, diode junctions, TTL and logic. Menu selection allows Range Lock,
TM
Probe Hold
, Relative Measurement, Auto Min Max Avg Measurement and
backlight on/off. The instrument is completely sealed.
D • Einleitung
Das Modell 220 ist ein 3-3/4-stelliges AC-gekoppeltes, mittelwert- messendes
Digitalmultimeter mit automatischer Bereichswahl. Es mißt Spannung, Strom,
Widerstand und Durchgang und führt Diodentest, TTL- und Logiktest aus. Eine
Menüwahl umfaßt Bereichssperre, Meßwertspeicher, Relativmessung, Auto Min
Max Avg und Anzeigen-Hintergrundbeleuchtung. Das Gerät ist vollständig
abgedichtet.
E • Introducción
El multímetro digital 220 es un instrumento de medidade 3-3/4 dígitos, trabajando
en alterna, con autorango, indicando las lecturas en valor medio y RMS, pudiendo
medir voltajes, corriente, resistencia, continuidad, diodos, uniones y lógica de tipo
TTL. El selector de menús permite el bloqueo de rango, retención del valor medido,
medición relativa, medición media, auto, mínima, máxima y apagado automático de
la iluminación de pantalla. El instrumento está completamente sellado.
D • Introduction
Le modèle 220 de est un multimètre numérique 3-3/4 digits à sélection
automatique des gammes, mesurant la valeur moyenne avec couplage CA. Il
mesure la tension, le courant, la résistance et la continuité, et effectue des tests de
diodes et de logique. Un menu de fonctions comprend le bloquage de gamme, le
maintien de lecture, la mesure relative, Auto Min Max Avg et un rétro-éclairage de
l’afficheur. L’instrument est complètement étanche.
WARNINGS AND PRECAUTIONS
■ This instrument is EN61010-1 certified for Installation Class II, 1000V and
Class III, 600V. It is recommended for use in distribution level and fixed
installations, as well as lesser installations, and not for primary supply lines,
overhead lines and cable systems. ■ All inputs are protected against continuous
overload conditions up to the limits of each function's stated input protection (see
specifications). Never exceed these limits
nor the ratings marked on the
- 2 -
instrument itself. ■ For voltage measurements, the circuit under test must be
protected by a 20A fuse or circuit breaker. ■ Exercise extreme caution when:
measuring voltage >20V, current >10mA, AC power line with inductive loads, AC
power line during electrical storms. High voltages can be lethal and high voltage
transients may occur at any time. ■ Operator injury or damage to the multimeter
may occur during current measurements if the fuse blows in a circuit with open
circuit voltage >600V (500V in mA input). ■ Always inspect your DMM, test
leads and accessories for signs of damage or abnormality before every use. If an
abnormal condition exists (broken or damaged test leads, cracked case, display
not reading, etc.), do not use. ■ When testing for voltage or current, make sure
these ranges function correctly. Take a reading of a known voltage or current first.
■ Never ground yourself when taking measurements. Do not touch exposed
metal pipes, outlets, fixtures, etc., which might be at ground potential. Keep your
body isolated from ground and never touch exposed wiring, connections, test
probe tips, or any live circuit conductors. Do not use the Flex-Strap to attach the
meter to your body. ■ Always measure current in series with the load – NEVER
connect the multimeter ACROSS a voltage source. Check fuse first. ■ Never
replace a fuse with one of a different rating. ■ Do not operate instrument in an
explosive atmosphere (flammable gases, fumes, vapor, dust.) ■ Do not use this
or any piece of test equipment without proper training ■ CRT SERVICE SAFETY
REMINDER : A potential danger exists when measuring voltages in the horizontal
output and damper stages of CRT equipment. (High voltage transients greater than
6,000 V). Refer to your CRT service manual for proper servicing instructions.
D • Warnungen und Vorsichtsmaßnahmen
■
Dieses Gerät ist EN61010-1/CE zertifiziert für Installationsklasse II, 1000V und
Klasse III, 600V. Anwendung ist empfohlen auf Verteilerebene und festen Anlagen
sowie untergeordneten Systemen, jedoch nicht für Starkstromnetze und Hochspannungsanlagen.
der verschiedenen Meßfunktionen (siehe Spezifikationen) oder andere Grenzen
welche auf dem Gerät markiert sind. ■Für Spannungsmessungen muß der Meßkreis
mit einer 20A Sicherung oder einem Trennschalter abgeschirmt sein.
beim Messen von Spannungen >20V // Strömen >10mA // Netzspannung bei
induktiver Last oder bei Gewittern // Strom, wenn die Sicherung durchbrennt in
einem Schaltkreis mit Leerlaufspannung >600V (>500V beim mA Eingang) // beim
Messen an Bildröhren (hohe Spannungsspitzen)
Meßkabel, Verbinder, usw. vor jeder Messung. Beschädigte Teile nicht verwenden
Meßspitzen und Stromkreis während der Messung nicht berühren o Sich selbst
■
Überschreiten Sie nie die kontinuierlichen Überlastgrenzen
■
Vorsicht
■
Unsersuchen Sie Gerät,
■
- 3 -
isolieren ! Das Gerät nicht mit der Trageschlaufe am eigenen Körper befestigen.
■
Bei Strommessung, Multimeter immer in Serie schalten – Nie in parallel mit
Spannungsquelle.
explosiver Umgebung verwenden.
■
Sicherung immer mit gleichwertiger ersetzen. ■Gerät nicht in
E • Advertencias y Precauciones
■
Este instrumento está homologado según EN61010-1/CE para la Categoría de
Instalación II - 1000V o Categoría de Instalación III - 600V. Su uso está
recomendado en el nivel de distribución y en instalaciones fijas, así como en
instalaciones menores, pero no en líneas principales de suministro, líneas aéreas
ni sistemas de cable.
funciones (vea Especificaciones), ni los límites marcados en el instrumento.
medidas de tensión, el circuito sometido a prueba debe estar protegido con un
fusible de 20 A o un disyuntor.
corriente >10 mA // tensión de red de CA con cargas inductivas // tensión de red de
CA durante tormentas eléctricas // corriente, si salta el fusible en un circuito con
tensión de circuito abierto >600 V (500 V en la entrada de mA) // trabajar con
pantallas TRC nInspeccione siempre el multímetro, las puntas de prueba, los
conectores y los accesorios antes de cada uso. No utilice ningún componente que
esté dañado.
nunca partes expuestas de los circuitos. No utilice la cinta "Flex-Strap" para sujetar
el multímetro a su cuerpo.
SERIE con la carga - NUNCA EN PARALELO con una fuente de tensión.
sustituya un fusible con otro que no tenga las mismas especificaciones.
el instrumento en ambientes potencialmente explosivos.
■
No supere nunca los límites de entrada para las diferentes
■
Tenga especial cuidado al: medir tensión >20 V //
■
No se ponga Ud. a tierra cuando esté tomando medidas, y no toque
■
Al medir corriente, conecte siempre el multímetro EN
■
■
No utilice
■
Para
Nunca
F • Avertissements et Précautions
■
Cet instrument est certifié EN61010-1/CE catégorie d’installation II, 1000 ou
catégorie III, 600V. Son utilisation est recommandée pour le niveau de distribution
de réseau, les installations fixes et systèmes subordonnés, et non pour les
installations de puissance et lignes de transmission et câblages à haute tension.
■
N’excédez jamais les limites de surcharge continues (voir spécifications) ou
d’autres limites marquées sur l’appareil. nPour les mesures de tension, le circuit
sous mesure doit être protégé par un fusible 20A ou par un disjoncteur.
prudent quand vous mesurez des tensions >20V ou des courants >10mA // tension
ou courant de secteur avec charge inductive ou par temps de tempête // du courant
quand le fusible saute dans un circuit avec tension en circuit ouvert de >600 volts
(>500V pour l’entrée mA) // dans des appareils à tube cathodique (transitoires à
haute tension) nInspectez appareil, câbles, connecteurs avant chaque mesure.
■
Soyez très
- 4 -
N’utilisez pas des pièces endommagées ■Ne touchez pas les pointes de touche ou
le circuit pendant les mesures. Isolez-vous ! N’utilisez pas la boucle de suspension
pour attacher l’appareil à votre propre corps.
l’appareil en série avec le circuit – JAMAIS en parallèle avec une source de tension.
■
Remplacez les fusibles toujours par des fusibles équivalents ■N’utilisez pas cet
appareil dans des atmosphères explosives.
■
Pour la mesure de courant, connectez
PREPARATION FOR USE – UNPACKING
Your shipping carton should include the multimeter, a holster, one test lead set
(one black, one red), one 9V battery (installed) and this manual. If any of the items
are damaged or missing, immediately return the complete package to the place of
purchase for an exchange.
D • Gebrauchsvorbereitung - Auspacken
Die Verpackung sollte enthalten: ein Multimeter, ein Schutzholster, ein Meßkabelsatz
(ein schwarz, ein rot), eine 9V Batterie (im Gerät) und diese Anleitung. Wenn ein Teil
fehlt oder beschädigt ist, bitte bei der Verkaufstelle umtauschen.
E • Preparación del multímetro para su uso - Desembalaje
El embalaje debe contener: el multímetro, una funda, un juego de puntas de prueba
(una negra y otra roja), una pila de 9 V (instalada), y este manual. Si falta algún
componente u observa daños, devuelva el conjunto al lugar donde lo adquirió para
que se lo cambien.
F • Préparation pour l’Emploi - Déballage
Votre emballage doit contenir: un multimètre, une gaine de protection, un jeu de
câbles de mesure (un rouge, un noir), une pile 9V (installée) et ce manuel. Si une
pièce manque ou est endommagée, retournez à votre point de vente pur un échange.
PROTECTIVE HOLSTER
The holster/tilt stand protects the meter from accidental falls and provides greater
ease of use. Both test lead probes can be attached to the holster for storage. One
probe can be attached for measurement, holding the meter with probe in one hand
and the second probe in the other hand.
D • Schutz-Holster
Das Schutzholster schützt das Gerät vor Stürzen und Stößen. Die Meßspitzen können
am Holster befestigt werden.
- 5 -
FUSED
MAX
430mA
MAX
mA
10A
VCOM
CAT II1000V
CAT III 600V
FUSED
10A MAX
1000V
750V
OFF
V
V
430
u
A
LOGIC
430
mA
43
mA
10A
REL RANGE
HOLD
220
MEM
A
DC
RANGE
AC
mVmV
muAmuA
MkMk
APOAPO
LOGIC MEM REC MAX MIN ALOGIC MEM REC MAX MIN AVG HOLDVG HOLD
SLEEP
OFF
MIN MAX
Menu Functions, see page 21
Menübalken – siehe “Menüfunktionen”, Seite 21
Barra de menú - ver “Funciones de menú”, página 21
Barre de menu - voir “Fonctions de Menu”, page 21
Low Battery, (p. 8)
Batterie entladen (S. 8)
Pila baja (p. 8)
Pile déchargée (p. 8)
Function/Range Selector,
Funktions-/Bereich-
Schalter
Selector de
Función/Escala
Sélecteur fonctions/
calibres
430mA Input (p. 13)
430mA Eingang (S. 13)
Entrada 430mA (p. 14)
Entrée 430mA (p. 15)
10A Input (p. 13)
10A Eingang (S. 13)
Entrada 10A (p. 14)
Entrée 10A (p. 15)
COM Input – common or low input for all measurements (p. 12)
COM Eingang – Referenzpunkt für alle Messungen (S. 12)
COM- entrada común o “baja” para todas las medidas (p. 12)
Entrée COM – commun ou bas pour toutes mesures (p. 12)
3-3/4 digit LCD with unit indicators
3-3/4 Digit LCD mit Einheitsanzeigen
LCD de 3-3/4 dígitos; indicadores de
unidades
LCD 3-3/4 digits; indicateurs d’unités
- 6 -
Menu Buttons, (p. 21)
Menutasten (S. 21)
Teclas de menú
(p. 21)
Boutons de menu
(p. 21)
High input for voltage
and resistance (p. 12)
V-Ω Eingang. Hoch
für Spannung und
Widerstand (S. 12)
Entrada “alta” para
tensión y resistencia
(p. 12)
Entrée V-Ω. Haut
pour tension et
résistance (p. 12)
E • Funda Protectora
La funda con pie integrado protege el medidor en caso de caídas accidentales. Las
puntas de prueba pueden fijarse a la funda.
F • Gaine de Protection
La gaine protège l’appareil contre des chutes accidentelles et des chocs. Les sondes
des cordons peuvent être attachées à la gaine.
OVERLOAD INDICATION
Input Overload (highest range in autoranging) is
indicated by “I.OL” and a continuous tone. Remove
test leads from the measurement setup as the input is
beyond the range of the meter.
Display Overload (input exceeds the selected range
while range is locked) is also indicated by “I.OL”. Select the next higher range
until a value is displayed, or return to autoranging. If overload still exists in the
highest range, remove test leads from the measurement setup as input is beyond
the range of the meter.
Note: The overload indication (no sound) is normal in the Ohms, continuity and
logic ranges. It appears in Ohms and continuity when the leads are not connected
to anything or when the measured value is higher than the selected resistance
range. It is on all the time in Logic.
Function Error: The meter dispays a function error
code “FErr” when a test lead is placed in the mA or
10A input jack and the selector switch is not set to the
correct current position. (If the DMM is connected to
a voltage source with leads set for current, very high
current could result). All current ranges are protected by fast acting fuses.
Battery Low: When the battery low indicator is
displayed the battery has less than 50 hours operation
and the accuracy of the meter can no longer be
guaranteed.
D • Überlastanzeige
Eingangs-Überlast (höchster Bereich in automatischer Bereichswahl - Fig. 1):
"I.OL" Anzeige und Dauerton. Messung unterbrechen da der Meßwert die
Eingangsgrenze überschreitet.
Bereichs-Überlast (Der Eingang überschreitet den betreffenden Bereich bei
- 7 -
manueller Bereichswahl - RANGE LOCK - Fig. 1): "I.OL" Anzeige. Höheren Bereich
wählen oder Messung unterbrechen.
Anmerkung: Überlastanzeige (ohne Ton) ist normal bei Widerstands- und
Durchgangsmessung wenn Meßkabel-spitzen offen sind oder wenn der Meßwert den
Bereich überschreitet. Bei Logikmessung ist die Überlastanzeige (ohne Ton)
permanent.
Eingangswarnung: (Fig. 2) "FErr" wird angezeigt wenn ein Meßkabel mit dem mA
oder 10A Eingang verbunden ist, der Wahlschalter jedoch nicht auf der richtigen
Stromfunktion steht. (Würde mit dem Stromeingang Spannung gemessen werden,
dann könnte ein sehr hoher Strom im Gerät entstehen). Alle Strombereiche sind mit
flinken Sicherungen geschützt.
Entladene Batterieanzeige (Fig. 3) : Bei dieser Anzeige sind weniger als 50
Betriebsstunden möglich. Die Geanuigkeit ist nicht länger garantiert.
E • Indicación de sobrecarga
La sobrecarga de entrada (en la escala superior en caso de selección
automática de escala) se indica mediante "I.OL" y un tono continuo. Desconecte las
puntas de prueba del circuito de medida, ya que el nivel de entrada es superior a la
capacidad del medidor.
La sobrecarga del visualizador (la entrada supera la capacidad de la escala
seleccionada en modo manual) también se indica mediante "I.OL". Seleccione una
escala más ata. Si ya está en la más alta, interrumpa la medida.
Nota: La condición de sobrecarga (sin sonido) es normal en los rangos de Ohmios,
continuidad y lógica. Aparece cuando las puntas de prueba en las escalas de ohmios
y continuidad no están conectadas a ningún componente, o cuando el valor medido,
es mayor que el rango de resistencia elegido. Está permanentemente encendida
cuando se elige la función lógica.
Aviso de Entrada Incorrecta: El visualizador muestra un código de error "FErr"
cuando se inserta una punta de prueba en la entrada de mA o 10 A y el selector no
está posicionado en el valor correcto de corriente. (Si se conecta el multímetro a una
fuente de tensión con las puntas en la entrada de corriente, podría exponer el
instrumento a corrientes muy elevadas). Todas las escalas de corriente están
protegidas mediante fusibles de acción rápida.
Batería baja: Cuando el indicador de batería baja aparece en pantalla, la batería
tiene menos de 50 horas de operatividad y la precisión del medidor no puede ser
garantizada.
- 8 -
F • Indication de Surcharge
F
E
D
F
E
D
Dépassement d’entrée (gamme la plus élevée en sélection automatique- Fig. 1):
affichage de "I.OL" et ton continu. Interrompez la mesure car l’entrée dépasse la
capacité de l’instrument.
Dépassement de gamme (l’entrée dépasse la gamme en sélection manuelle RANGE LOCK - Fig. 2): indication de "I.OL". Choisissez une gamme supérieure ou
interrompez la mesure.
Note: Une indication de surcharge (sans son) est normale dans les calibres de
résistance et de continuité, quand les pointes de touche ne sont pas connectées, ou
si la résistance mesurée dépasse le calibre. Dans le test logique, l’indication de
surcharge (sans son) est permanante.
Avertissement d’Entrée (Fig. 2): "FErr" est affiché quand un cordon de test est
relié à l’entrée mA ou 10A alors que le sélecteur de fonctions n’est pas mis sur la
fonction de courant correcte. (Une mesure de tension en utilisant une entrée de
courant peut occasionner un courant très élevé dans l’appareil). Toutes les gammes
de courant sont protégées par fusibles rapides.
Pile déchargée (Fig. 3): Cet affichage indique que la durée de vie de la pile est
tombée en-dessous de 50 heures. La précision n’est plus garantie.
Dangerous voltage warning (also double beep tone). Indicates input voltages
higher than 25V. Gefährliche Eingangsspannung - über 25V (auch doppelter
Biep-Ton). Advertencia de “tensión peligrosa” (también doble “bip”). Indica
tensiones de entrada superiores a 25 V. Indication de tension dangereuse supérieure à 25V (également double bip sonore).
Polarity indication Polaritätsanzeige Indicación de polaridad Indication
de polarité
E
D
E
D
F
F
E
Low-battery voltage Batterie entladen Pila baja Pile déchargée
Menu Functions - See page 21
Menu-Funktionen -– siehe Seite 21 Funciones de menú, ver página 21
Fonctions de menu – voir page 21
Audible Feedback
The meter emits a single beep when a parameter is changed, a “valid” front panel
button is pushed, or Probe Hold values are updated.
The meter emits a continuous tone in the case of input overload, for continuity
measurement when resistance is <50Ω, and for current measurements, when the
10A input is used and the current exceeds 10A.
- 9 -
F
D • Akustische Anzeigen
Das Gerät gibt einen Einzelton ab bei Funktionswechsel, bei Aktivierung einer
"validen" Taste und wenn neue Anzeigenspeicherwerte erfaßt werden. Ein Dauerton
wird abgegeben bei Eingangsüberlast, bei Durchgangsmessung, wenn der
Widerstand unter 50Ω liegt und beim Messen im 10 Bereich, wenn der
Eingangsstrom 10A überschreitet.
E • Avisos audibles
El medidor emite un solo pitido, cuando se cambia un parámetro, se debe pulsar la
tecla "valid" del panel frontal ya que en caso de hacerlo, los valores medidos son
actualizados. El medidor emite un tono continuo en caso de sobrecarga de entrada, y
midiendo continuidad cuando el valor de la resistencia es <50Ω. Cuando se usa la
entrada de 10 A, el medidor emite un tono continuo si la corriente supera los 10 A.
F • Indication Sonore
L’instrument émet un bip sonore en cas de changement de fonction, quand un
bouton valide est pressé ou une nouvelle valeur est enregistrée en Probe Hold. Un
signal sonore continu indique un dépassement de la limite d’entrée, une résistance
inférieure à 50Ωen mesure de continuité, ou un courant supérieur à 10A en mesure
de courant (avec l’entrée 10A).
MEASURING PROCEDURES
GENERAL: Turn instrument on by turning function/range switch away from OFF
and selecting the parameter you want to measure.
Ranging: This instrument is autoranging on all Volts and Ohms ranges and
manual ranging on Amperes ranges. When in Volts and Ohms ranges, it automatically selects the range that gives the best resolution for the measured value. A
range can be locked through menu selection (see Menu Functions, page 24). You
can tell which range you are in by the position of the decimal point and the
measurement unit displayed.
General Measurement Procedures: ■ When connecting or disconnecting
test leads to a circuit, always turn off power to device or circuit being tested and
discharge all capacitors. ■ Strictly observe the max input limits. ■ Do not
change functions while test leads are connected to circuit.
D • Meßprozeduren
Einschalten: Gerät einschalten durch Funktions-Bereichsschalter weg von OFF
nach der gewünschten Funktion drehen.
Bereichswahl: Dieses Gerät hat automatische Bereichswahl für Spannungs- und
Widerstandsmessung und manuelle Bereichswahl für Strommessung. Bei Spannung
und Widerstand wählt das Gerät automatisch den Bereich der die beste Auflösung
- 10 -
bietet. Ein Bereich kann durch Menüwahl festgehalten werden (siehe Menüfunktionen, Seite 24). Der Dezimalpunkt und die angezeigte Einheit geben an in
welchem Bereich Sie sich befinden.
Allgemein:
diesen abschalten und Kondensatoren entladen.
überschreiten.
dem Schaltkreis verbunden sind.
■ Vor Verbinden und Trennen der Meßkabel mit dem Schaltkreis,
■ Maximale Grenzen nicht
■ Keinen Funktionswechsel vornehmen während die Meßspitzen mit
E • Procedimientos de medida
GENERAL: Encienda el instrumento, poniendo el selector de función/escala fuera
de OFF y seleccionando el parámetro que desee medir.
Escalas: Este instrumento funciona en modo autorango para mediciones de voltaje
y ohmios y en modo manual en las mediciones de amperios. Cuando se trabaja en
voltios y ohmios, el aparato selecciona de forma automática el rango de mejor
resolución para el valor medido. Es posible fijar una escala desde el menú (vea
Funciones de menú, pág. 24). La escala en que está en un momento dado puede
determinarse por la posición del punto decimal y las unidades de medida.
Procedimientos generales:
prueba a/de un circuito, apague siempre el dispositivo o circuito sometido a prueba
y descargue todos los condensadores.
máximos de entrada.
conectadas a un circuito.
■ Antes de conectar o desconectar las puntas de
■ Observe estrictamente los límites
■ No cambie de función mientras las puntas de prueba estén
F • Procédures de Mesure
Mise sous tension: Allumez l’appareil en tournant le sélecteur de fonctions à
partir de OFF vers le paramètre à mesurer.
Sélection des gammes: La sélection de gammes est automatique pour les
mesures de tension et de résistance, et manuelle pour la mesure de courant. En
mesure de tension et de résistance, l’appareil choisit automatiquement le gamme qui
offre la meilleure résolution. Une gamme peut être bloquée par sélection de menu
(voir page 24). Le point décimal et l’unité affichée indiquent la gamme dans laquelle
vous mesurez.
■ Avant de connecter ou de déconnecter les cordons de test, coupez
Général:
l’alimentation du circuit à mesurer et déchargez les condensateurs.
pas les limites d’entrée.
touche sont connectées au circuit.
■ Ne changez pas de fonction tandis que les pointes de
■ Ne dépassez
- 11 -
FUSED
MAX
430mA
MAX
mA
10A
VCOM
CAT II1000V
CAT III 600V
FUSED
10A MAX
1000V
750V
OFF
V
V
430
u
A
LOGIC
430
mA
43
mA
10A
REL RANGE
SLEEP
OFF
MIN MAXHOLD
220
MEM
A
DC
V
red/rot/
roja/rouge
2
1
3
4
V or
V
> 20V
DC AND AC VOLTAGE MEASUREMENT (See Fig. 4)
❶Connect test leads as shown in figure 1. ❷Turn function selector switch to V
or V . ❸Touch Probe tips across voltage source (in parallel with circuit).
❹Voltage value will appear on Digital Display along with the voltage polarity (for
DC).
D • Gleich- und Wechselspannungsmessung (Siehe Fig. 4)
❶
Meßkabel gemäß Fig.1 verbinden. ❷Funktionsschalter auf V or V stellen.
❸
Meßspitzen mit Meßkreis verbinden – parallel zur Spannungsquelle. ❹Meßwert
ablesen (automatische Polaritätsanzeige bei DC Messungen).
Fig. 4
- 12 -
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.