MCS-425 Microwave sensor switch
Installation Instruction
How to use
1.Before turning-on this unit, please make sure all cables are
connected properly.
2.The mounting height is 230 cm.
3.Antenna angle (D) is adjustable, the higher the antenna angle,
the wider the detection range that can be detected. Instead, the
lower the antenna angle, the narrower the detection range that
can be detected.
4.Turn the (A) clockwise to increase the antenna detection range,
or the counter-clockwise turn to decrease the antenna detection
range.
5.Turn the (C) clockwise to increase the relay actuation time, or
the counter-clockwise turn to decrease the relay actuation time.
Jumper
N.C.
A
N.O.
C
D
+ AC/DC 12~24V
N.C
Com.
N.O.
LED
Relay mode and Jumper Status
Jumper mode
N.O.
N.C.
Relay Normal Status
N.O.=OPEN
N.C.=CLOSED
LED OFF
N.O.=CLOSED
N.C.=OPEN
LED ON
Detects the signal
Relay Action Status
N.O.=CLOSED
N.C.=OPEN
LED ON
N.O.=OPEN
N.C.=CLOSED
LED OFF
Specifications
Power Input: 12 V~24V AC/DC (self-regulating)
Maximum current: 80 mA
Frequency: 10.525 GHz
Relay rated 3A, 125VAC / 30VDC
A
C
No power
Relay Statue
N.O.=OPEN
N.C.=CLOSED
LED OFF
N.O.=OPEN
N.C.=CLOSED
LED OFF
Relay actuation time: 0.5~4Seconds
Sensor Angle: 7.5° ~ 82.5°
Operating Temperature Range: -20°C ~ +55°C
Dimensions: 122.5(W) * 72(H) * 63 (D)mm
Clockwise turns on switch to is biggest.
Clockwise turns on switch to increase the
relay actuation time. (0.5~4Seconds)
The factory settings
Microwave Antenna stand angel: 35°
Jumper: N.O. (Normal open)
Adjustment resistance:
(A) Clockwise turns on switch to is
biggest.
(C) Clockwise turns on switch to
increase the relay actuation time.
Detection Range: 4.5 meter
Application
MCS-425 microwave sensor switch can be used with access control system which it can work as a request to exit.
The diagrams below illustrate the two recommended ways of installing the and access control devices after power input
(power on).
Fig. A The connection for fail-safe Lock devices:
Jumper(N.C.)
N.C.
Control Device
Relay output
control
Copyright © 2008 Gianni industries, inc. All rights reserved.
+
-
N.C
Com.
N.O.
N.C
Com.
N.O.
Published on2008.08.20P-MU-MCS-425 Ver.C
Power Supply
Locking Device
(fail-safe)
Fig. B The connection for fail-secure Lock devices:
MCS-425
Jumper(N.C.)
N.C.
Control Device
Relay output
control
N.C
Com.
N.O.
+
-
N.C
Com.
N.O.
Power Supply
Locking Device
(fail-secure)