Venstar T4700 Owner's Manual And Installation Instructions

with Humidity Control
i
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15, subpart C of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference in radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that of the
receiver.
•Consult the dealer or an experienced radio or TV technician for help.
Notice: Only peripherals complying with FCC limits may be attached to this equipment. Operation with noncompliant peripherals or peripherals not recommended by Venstar, is likely to result in interference to radio and TV reception. Changes or modifications to the product, not expressly approved by Venstar could void the user’s authority to operate the equipment.
FCC - INDOOR Mobile Radio Information: To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.
Follow the Installation Instructions before proceeding. Set the thermostat mode to “OFF” prior to changing settings in setup or restoring Factory Defaults.
CAUTION
This Voyager thermostat has the ability to receive updates to its firmware. Periodically firmware updates are released by the manufacturer to add features and/or performance enhancements. This manual was produced reflecting the most current firmware/feature set at the time of publication, firmware rev. 1.0. Firmware releases after rev. 1.0 may not be adequately depicted in this manual. Please refer to the appropriate website or contact your place of purchase to learn about changes to the thermostat after firmware release 1.0.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Cet appareil est conforme avec Industrie Canada, exempts de licence standard RSS(s). Son fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne doit pas causer d’interférences, et 2) ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de l’appareil.
En vertu des règlements d’Industrie Canada, cet émetteur de radio ne peut fonctionner en utilisant une antenne d’un type et maximale (ou moins) Gain approuvé pour l’émetteur par Industrie Canada. Pour réduire les interférences radio potentielles aux autres utilisateurs, le type d’antenne et son gain doivent être choisis afin que la puissance isotrope rayonnée équivalente (PIRE) ne est pas plus de ce qui est nécessaire pour une communication réussie.
We, Venstar, declare under our sole responsibility that the device to which this declaration relates: Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC ID: MUH-SKYPORT3
IC: 12547A-SKYPORT3
These numbers can be located on the inside of the thermostat backplate, in the upper right corner.
MUH-SKYPORT3
ii
iii
Glossary of Terms
Auto-Changeover: A mode in which the thermostat will turn on the
heating or cooling based on room temperature demand.
Cool Setpoint: The warmest temperature that the space should rise to
before cooling is turned on (without regard to deadband).
Deadband: The number of degrees the thermostat will wait, once a
setpoint has been reached, before energizing heating or cooling.
Dehumidify: To reduce the amount of moisture in the air.
Differential: The forced temperature difference between the heat
setpoint and the cool setpoint.
Heat Setpoint: The coolest temperature that the space should drop to
before heating is turned on (without regard to deadband).
Humidify: To increase the amount of moisture in the air.
Icon: The word or symbol that appears on the thermostat display.
Mode: The current operating condition of the thermostat (i.e. Off, Heat,
Cool, Auto).
Non-Programmable Thermostat: A thermostat that does not have the
capability of running Time Period Programming.
Override: During programmed unoccupied periods, pressing the
Override button will force the thermostat into occupied settings. During programmed occupied periods, pressing the Override button will force the thermostat into unoccpied settings.
Programmable Thermostat: A thermostat that has the capability of
running Time Period Programming.
Reheat: Running the cooling and 2nd stage strip heaters at the same
time in order to dehumidify the air without signicantly cooling down the room temperature.
Temperature Swing: Same as Deadband.
iv
Table of Contents
GET TO KNOW YOUR THERMOSTAT
Get to Know Your Thermostat .................................................... 1
Quick Start .................................................................................. 6
INSTALLATION INSTRUCTIONS
Installation Instructions .............................................................. 9
Sample Wiring Diagrams ........................................................... 13
Test Operation ............................................................................ 16
USER SETUP
Backlight Operation ................................................................... 17
Scrolling Display Options .......................................................... 18
Emergency Heat ........................................................................ 18
Wireless Modules....................................................................... 19
Service Filter .............................................................................. 23
Runtimes .................................................................................... 24
Available Modes......................................................................... 25
INSTALLER SETUP
Setpoint Limits ........................................................................... 26
Timers and Deadbands ............................................................. 27
Humidication & Dehumidication ............................................ 28
Dry Contact Operation ............................................................... 29
Holiday ....................................................................................... 29
Remote Sensor Operation ......................................................... 30
Factory Defaults ......................................................................... 32
TECHNICIAN SETUP
Sensor Calibration ..................................................................... 33
Equipment Testing ..................................................................... 33
Advanced Setup Table ............................................................... 34
Troubleshooting ......................................................................... 36
INDEX ........................................................................................... 37
WARRANTY .................................................................................. 41
1
Get To Know Your Thermostat
Optional Wireless Module
Backlit, Scrolling Display
Backlit Cooler & Warmer Buttons
Backlit LCD Display
Override Button
Heat or Cool Demand Indicator
Red = Heat, Green = Cool
Setup Buttons Behind Door
2
Get To Know Your Thermostat
Setup Buttons
3
Get To Know Your Thermostat
Display Features
1 The scrolling display will be used to help you easily navigate
the setup screens in the thermostat.
2 Clock with Day of the Week
Indicates the current time and day. This clock is also used to program the time period schedules.
3 Mode Indicators
Selects the operational mode of the equipment. HEAT - Indicates the heating mode. COOL - Indicates the air conditioning mode. HEAT & COOL - Indicates the system will automatically change-over between heat and cool modes as the temperature varies. OFF - Indicates heating and cooling is turned off.
4 Room Temperature Display
Indicates the current room temperature and displays the outdoor temperature when selected.
5 Outdoor icon
Indicates the temperature displayed is from the optional outdoor sensor.
HI
Lo
Outdoor
Fan On
COOL
AUXHEAT
Override
Day Night Morning Evening
Setup Step
2nd
Stage
Am Pm
18:88
188
188
88
188
1
3
3
4
5
2
4
Get To Know Your Thermostat
Display Features
6 Desired Set Temperature
Indicates desired room temperature(s). Also displays the highest and lowest temperatures for the day.
7 Wi-Fi icons
One dot indicates the thermostat recognizes the wireless module. The “pull” icon indicates the thermostat is currently connected to the Local access point, via the optional Wi-Fi Module.
8 Setup Step icon
Indicates the step number when the thermostat is in the setup mode.
9 2nd Stage icon
Indicates what stage of cooling or heating is currently energized.
10 icon
Indicates the keypad has been locked.
Outdoor
Fan On
COOL
AUXH
EAT
Override
Day Night Morning Evening
Setup Step
2nd
Stage
Am Pm
18:88
188
188
88
188
10
6
6
7
8
9
5
Get To Know Your Thermostat
11 AuxHeat icon
Indicates 2nd stage electric strip heat is being used when the thermostat is programmed for Heat Pump operation. Only the Aux icon will appear during Cool to Dehumidify to indicate Reheat operation.
12 Fan On icon
Indicates constant, continuous fan operation.
When Fan On is not lit - indicates the fan will only operate when necessary to heat or to cool.
HI
Lo
Outdoor
Fan On
COOL
AUXH
EAT
Override
Day Night Morning Evening
Setup Step
2nd
Stage
Am Pm
18:88
188
188
88
188
11
12
Display Features
6
Quick Start
During Setup and Programming:
Press the WARMER or COOLER buttons to modify the selection. Press the MODE button to advance and confirm through the setup steps.
Setting the Clock and Day
Not available when connected to a Skyport Account
Press the SET CLOCK button. Adjust the clock using the WARMER or COOLER buttons. Press MODE to advance to the day setting. Adjust the day using the WARMER or COOLER buttons. Press the SET CLOCK button to confirm settings.
TIP: To adjust the time by hours press and hold the FAN button while pressing the WARMER or COOLER buttons.
Selecting the Heat or Cool Mode
Select mode by pressing the MODE button.
Heating Only - Only the heating operation will be controlled by the
thermostat in this mode.
Cooling Only - Only the cooling operation will be controlled by the thermostat in this mode.
Heating or Cooling (Auto-Changeover) - AUTO will automatically select heat or cool based on room temperature demand.
OFF - OFF indicates both heating and air conditioning systems are turned off.
MODE
WARMER
COOLER
MODE
Set
Clock
7
Quick Start
Selecting your desired temperature
AUTO-CHANGEOVER MODE - Pressing the WARMER or COOLER buttons in Auto mode will adjust both the heat and cool setpoints simultaneously. To adjust heat and cool setpoints individually, choose HEAT mode to adjust the heat setpoint and COOL mode to adjust the cool setpoint, then return to AUTO mode.
HEAT OR COOL MODE - Pressing the WARMER or COOLER buttons in Heat or Cool mode will adjust only the heat or cool setpoints individually displayed.
Using the Fan Button
Fan On indicates constant fan operation. Fan On is not allowed when the thermostat is in the OFF mode. Pressing the FAN button toggles this feature on or off. Fan auto will allow the fan to run only when there is a heat or cool demand.
Using the Override Button
UNOCCUPIED OPERATION - During a Dry Contact forced unoccupied period, pressing the OVERRIDE button will temporarily force the thermostat into the mode it was in before the Dry Contact forced it into the Unoccupied mode. For example: If the thermostat was in the Auto mode and the Dry Contact forced the thermostat into the Unoccupied mode, then pressing the OVERRIDE button will force the thermostat back into the Auto mode. The remaining override time will be displayed in the upper left hand corner of the display. The override timer can be set up to a maximum of four (4:00) hours, in increments of 30 minutes. If the timer has been set for the maximum time, the next press of the OVERRIDE button will reset the timer, returning the thermostat to the Unoccupied mode. To adjust the setpoints for the Unoccupied mode, see page 29.
Current Override Hours (Setup step 10) - This counter keeps track of the number of hours that the thermostat is overridden into Occupied settings. Press FAN to reset.
FAN ON
AUTO
OVERRIDE
Viewing the Temperature Sensors
OUTDOOR TEMP - Press the OUTDOOR button to view the current outdoor temperature. If connected to a Skyport account, pressing outdoor button will show the temperatures for your location if you don’t have a wired sensor connected. Press the OUTDOOR button again to view any connected wired sensor (Remote or Supply).
Note: If no outdoor sensor is connected, and there isn’t outdoor temperature via Wi-Fi, then 2 dashes [- -] will appear with the first button press.
REMOTE/SUPPLY TEMP - Press the Accessory Status button to view linked wireless and wired sensors and other accessories. Press the Accessory Status button to return to the main screen. Setup step #26 selects the use of the wired temperature sensor.
Viewing the Indoor Humidity Sensor
IMPORTANT: Allow at least 2 minutes after the thermostat is powered on for the humidity to read correctly.
Press the HUMIDITY button then the mode button to display the current humidity measured at the thermostat. The room’s relative humidity is displayed in the top left corner. The humidification setpoint appears in the larger, center display and can be adjusted using the WARMER or COOLER buttons. Press the MODE button again to view and adjust the dehumidification setpoints. Press the HUMIDITY or MODE button again to confirm settings and return to normal operation.
Note: Due to variations in environmental and equipment conditions, it is not always possible to achieve the desired humidification or dehumidification setpoint.
OUTDOOR
OVERRIDE
OUTDOOR
ACCSRY
HUMIDITY
OVERRIDE
ACCESSORY
STATUS
8
Quick Start
9
Installation Instructions
Remove and Replace the old thermostat
To install the thermostat properly, please follow these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.
Assemble tools: Flat blade screwdriver, wire cutters and wire
strippers.
Make sure your Heater/Air Conditioner is working properly
before beginning installation of the thermostat.
Carefully unpack the thermostat. Save the screws, any brackets,
and instructions.
Turn off the power to the Heating/Air Conditioning system at
the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace.
Remove the cover of the old thermostat. If it does not come off
easily, check for screws.
Loosen the screws holding the thermostat base or subbase to
the wall and lift away.
If you have a smart phone handy, take a photo of the wiring for
future reference.
Disconnect the wires from the old thermostat. Tape the ends of
the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat.
Keep the old thermostat for reference purposes, until your new
thermostat is functioning properly.
10
Installation Instructions
Wire Connections
If the terminal designations on your old thermostat do not match those on the new thermostat,
refer to the chart below or the wiring
diagrams that follow.
Wire from the Install on the old thermostat Function new thermostat terminal marked connector marked
G or F Fan G
Y1, Y Cooling Y1
W1, W Heating W1/0/B
Rh, R, M, Vr, A Power R
C Common C
O/B Rev. Valve W1/O/B*
W2 2nd Stage Heat W2
Y2 2nd Stage Cooling Y2
H, Hum Humidity HUM
D, Dehum Dehumidity DEHUM
Ck1 Dry Contact Switch DRY CONTACT
CKGND Dry Contact Switch DRY CONTACT
* O/B is used if your system is a Heat Pump.
Loading...