Venstar T0140 User Manual

residential
THERMOSTAT
Digital
Digital
Thermostat
Thermostat
NON-
NON-
PROGRAMMABLE
PROGRAMMABLE
up to
up to
& 1-cool
& 1-cool
HEAT
HEAT
PUMP
PUMP
Stages: 2-Heat, 1-Cool
Battery or System Powered
Auxiliary Heat Indicator
Fahrenheit or Celsius
Bi-Color LED (when system powered)
T0140
2-heat
2-heat
Use with most 1 or 2 Stage Heat Pump Heat and 1 stage Heat Pump Cool units
MANUAL
MANUAL
Venstar Inc. 05/08
OWNER'S MANUAL
T0140
Contents
Page #
Safety Warnings Front Panel Display Normal Operation Aux Heat Fahrenheit or Celsius Preparation Remove Old Thermostat Battery Replacement Wire Connections Test Operation Troubleshooting Warranty

Page 2

OWNER'S MANUAL
Safety Warnings
T0140
P/N T0140
CAUTION
Follow Installation Instructions carefully.
DISCONNECT POWER TO THE HEATER ­AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT.
WARNING
CAUTION
The two Alkaline “AA” batteries must be replaced at least once every 12 months to ensure proper operation. The “Low Battery” icon will appear on the thermostat display when it is time to replace the batteries. If the thermostat is connected to 24v power, the batteries should still be installed, but are not required.
When “Low Battery” is displayed the batteries must be replaced immediately. The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced.
Annual battery replacement is especially critical in locations subject to freezing temperatures. The thermostat will be unable to turn on the heating system if the batteries are exhausted.

Page 3

OWNER'S MANUAL
Front Panel
T0140
DISPLAY
70
FAN SWITCH
On or Auto
MODE SWITCH
Cool, Off or Heat
AUX HEAT SWITCH
Emergency Normal Lockout
COOLER & WA R M E R BUTTONS
BI-COLOR LED
Heat or Cool demand indicator when system powered: Red = Heat Green = Cool
BATTERY DOOR

Page 4

OWNER'S MANUAL
SET TEMP
AUX
HEAT
COOL
T0140
Display
LOW BATTERY
Heat and Cool indicators. In normal operation, Heat or Cool appears, depending on the Mode Switch position. When heat or cool is energized, the Heat or Cool indicator will flash. If the thermostat is system powered the bi-color LED will also illuminate (red for heating and green for cooling).
Current room or set temperature.
Desired set temperature indicator. When this indicator is on, the large numbers represent the desired room temperature. Pressing the COOLER or WARMER button during normal operation will cause the large numbers to switch from the current room temperature to the desired set temperature.
Indicates battery life is low; it is recommended to replace the batteries at this time.
Indicates auxiliary heat is energized.
88

Page 5

OWNER'S MANUAL
Normal Operation
HEAT
70
FAN SWITCH
On or Auto
Operation
Select Cool or Heat with the Mode Switch. Normally leave the fan switched to Auto. In Fan Auto, the fan will turn on only with a heat or cool demand. When Fan On is selected, the fan will run continuously. Adjust the desired set temperature with the COOLER or WARMER buttons.
T0140
MODE SWITCH
Cool, Off or Heat
COOLER & WA R M E R BUTTONS

Page 6

OWNER'S MANUAL
T0140
Aux Heat
HEAT
70
AUX HEAT SWITCH
Emergency - Disables all compressor functions* and energizes only Aux Heat to satisfy the heat demand.
Normal - Aux Heat is allowed to run, if necessary, along with the heat pump to satisfy the heat demand.
Lockout - Aux Heat will never turn on regardless of the heat demand.
When the Aux Heat switch is in the Emergency position the
*
compressor will also be locked out during cooling operation.

Page 7