DVM9912 – AUTORANGING MULTIMETER
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle
could harm the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a
specialised company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying the DVM9912! Please read the manual thoroughly before bringing this device into service. If
the device was damaged in transit, don't install or use it and contact your dealer.
2. Safety information
The following safety information must be observed in order to ensure maximum personal safety during the use
of this device.
• Do not use the meter if the meter or the test leads look damaged or if you suspect the meter is not
operating properly.
• Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets,
fixtures, etc., which might be at ground potential. Keep your body isolated from ground by using dry
clothing, rubber shoes, rubber mats or any other approved insulating material.
• Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Even small
amounts of current can be dangerous.
• Use caution when working above 60VDC or 30VAC rms as such voltages pose a shock hazard.
• When using the probes, keep your fingers behind the finger guards on the probes.
• Measuring voltage which exceeds the limits of the multimeter may damage the meter and expose the
operator to electrical shocks. Always respect the meter voltage limits as stated on the front of the meter.
• Never apply voltage or current to the meter that exceeds the specified maximum:
Input Limits
Function Max. Output
VDC or VAC 600VDC, 600VAC
mA DC/AC 400mA DC/AC
A DC/AC 10A DC/AC (30 seconds max every 15 minutes)
Frequency, Resistance, Capacitance, Duty Cycle,
Diode test, Continuity
Temperature 250V DC/AC
250V DC/AC
DVM9912 VELLEMAN
4
3. Safety symbols
WARNING
WARNING:
Risk of electrocution. High voltage circuits, both AC and DC, are very dangerou
s and
CAUTION
4. Controls and jacks
1. 4000 count LCD-Display with symbols
2. function sw itch
3. 10A (pos itive) input jack for 10A DC or AC measurements
4. COM (negative) input jack
5. positive input jack
6. MODE push button
7. RANGE pus h button
8. DATA HOLD push button
9. RELATIVE push button
5. Symbols and indicators
BAT Low Battery
DATA HOLD Data Hold
AUTO Auto ranging
AC Alternating Current or Voltage
DC Direct Current or Voltage
This symbol next to another symbol, terminal or operating device indicates that
the operator should pay heed to the instructions in the manual in order to avoid
personal injury or damage to the meter.
This warning symbol indicates a potentially hazardous situation, which, if not
avoided, could result in serious injury or death.
This warning symbol indicates a potentially hazardous situation, which, if not
avoided, could result in damage to the product.
A terminal marked with this symbol should not be connected to a circuit point of
which the voltage exceeds 500 VAC or VDC above ground.
This symbol next to one or more terminals indicated that they may carry
particularly hazardous voltages. For maximum safety, do not use the meter and
the test leads if you see this symbol.
Continuity
Diode
6. Operation
should be measured with great care.
1. ALWAYS turn the function sw itch to the OFF position when the meter is not in use. This meter has an auto
OFF function that automatically switches the meter OFF after 15 minutes of inactivity.
2. If “OL” appears on the display during a measurement, the value exceeds the range you have selected.
Change to a higher range.
DVM9912 VELLEMAN
5
NOTE: In some low AC and DC voltage ranges, with the test leads not connected to a device, the display may
CAUTION:
Do
not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large
show a random, changing reading. This is normal and is caused by the high input sensitivity. The
reading will stabilise and give a proper measurement when connected to a circuit.
MODE BUTTON
To select Diode/Continuity, DC/AC, Hz/%Duty
RANGE BUTTON
When the meter is turned on for the first time, it automatically goes into Autoranging mode. This mode
automatically selects the best range for the measurements and is generally the best mode for most
measurements. For measurements situations that require a manually selected range, perform the following
actions:
1. Press the RANGE button. The “AUTO” indication on the display will disappear.
2. Press the RANGE button to go through the available ranges and you select the range you want.
3. Press and hold the RANGE button for 2 seconds to exit the ManualRanging mode and return to
AutoRanging.
DATA HOLD BUTTON
The data hold function allows the meter to “freeze” a measurement for later reference.
1. Press the DATA HOLD button to freeze the reading on the display. The indicator “HOLD” will appear on the
display.
2. Press DATA HOLD again to return to normal operation.
RELATIVE BUTTON
The relative measurement feature allows you to make measurements relative to a stored reference value. A
reference voltage, current, etc. can be stored and measurements made in comparison to that value. The
displayed value is the difference between the reference value and the measured value.
1. Perform any measurement as described in the operating instructions.
2. Press the RELATIVE button to store the reading in the display and the “REL” indicator will appear on the
display.
3. The display will now indicate the difference between the stored value and the measured value.
4. Press the RELATIVE button to return to normal operation.
7. Measurements
DC VOLTAGE MEASUREMENTS
voltage surges may occur that can damage the meter.
DVM9912 VELLEMAN
6
1. Set the function sw itch to the V position (“mV” will appear on the display). The device will automatically
WARNING:
Risk
of electrocution. The probe tips may not be long enough to contact the live parts inside
CAUTION:
Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large
CAUTION:
Do not carry out current measurements on the 10A scale for a period longer than 30
select DC.
2. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into
the positive (V) jack.
3. Touch the test probe tips to the circuit under test. Be sure to observe the correct polarity (red lead to
positive, black lead to negative).
4. Read the voltage on the display. The display will indicate the proper decimal point and value. If the polarity
is reversed, the display will show (-) minus before the value.
AC VOLTAGE MEASUREMENTS
some 240V appliance outlets because the contacts are recessed deep in the outlets. As a
result, the reading may show 0V when the outlet actually carries voltage. Make sure the
probe tips are touching the metal contacts inside the outlet before assuming that there is no
voltage is present.
voltage surges may occur that can damage the meter.
1. Set the function sw itch to the V position. Press MODE to select AC voltage.
2. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into
the positive (V) jack.
3. Touch the test probe tips to the circuit under test.
4. Read the voltage in the display. The display will indicate the proper decimal point, value and symbol (AC,
V, etc.).
DC CURRENT MEASUREMENTS
seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.
1. Insert the black test lead banana plug into the negative (COM) jack.
2. For current measurements up to 4000µ A DC, set the function switch to the µ A position and insert the red
test lead banana plug into the (µ A) jack.
3. For current measurements up to 400mA DC, set the function switch to the mA range and insert the red test
lead banana plug into the (mA) jack.
4. For current measurements up to 10A DC, set the function switch to the A position and insert the red test
lead banana plug into the 10A jack.
5. Press the MODE button until “DC” appears in the display.
6. Remov e the power from the circuit under test, then open up the circuit at the point where you wish to
measure current.
7. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive
side of the circuit.
8. Apply pow er to the circuit.
9. Read the current on the display. The display will indicate the proper decimal point, value and symbol.
DVM9912 VELLEMAN
7
AC CURRENT MEASUREMENTS
WARNING:
To avoid electric shock, do not measure AC current on any circuit with a voltage exceeding
CAUTION:
Do
not carry out current measurements on the 10A scale fo
r a period longer than 30
WARNING:
To avoid electric shock, disconnect power to the unit under test and discharge all
WARNING:
To
avoid electric shock, never measure continuity on circuits or wires that have voltage on
them.
250V AC.
seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.
1. Insert the black test lead banana plug into the negative (COM) jack.
2. For current measurements up to 4000µ A AC, set the function switch to the µA position and insert the red
test lead banana plug into the (µ A) jack.
3. For current measurements up to 400mA AC, set the function switch to the mA range and insert the red test
lead banana plug into the (mA) jack.
4. For current measurements up to 10A AC, set the function switch to the A position and insert the red test
lead banana plug into the 10A jack.
5. Press the MODE button until “AC” appears in the display.
6. Remov e power from the circuit under test, then open up the circuit at the point where you wish to measure
current.
7. Touch the black test probe tip to the negative side of the circuit. And touch the red test probe tip to the
positive side of the circuit.
8. Apply pow er to the circuit.
9. Read the current on the display. The display will indicate the proper decimal point, value and symbol.
RESISTANCE MEASUREMENTS
capacitors before taking any resistance measurements. Remove the batteries and unplug
the line cords.
1. Set the function sw itch to the Ω position.
2. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into
the positive Ω jack.
3. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part
under test so the rest of the circuit will not interfere with the resistance reading.
4. Read the resistance on the display. The display will indicate the proper decimal point, value and symbol.
CONTINUITY CHECK
1. Set the function sw itch to the
2. Insert the black lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into
the positive (+) jack (Ω).
3. Press the MODE button until the symbol appears on the display.
4. Touch the test probe tips to the circuit or wire you wish to check.
If the resistance is less than approximately 30 Ω, the audible signal will sound. The display will also show
the actual resistance.
DVM9912 VELLEMAN
position.
8
DIODE CHECK
WARNING:
To avoid electric shock, do not test any diode that has voltage on it
.
WARNING:
To avoid
electric shock, disconnect power to the unit under test and discharge all
WARNING:
To
avoid electric shock, disconnect both test probes from any source
of voltage before
carrying out a temperature measurement
.
1. Set the function switch to the position.
2. The symbol will appear on the screen.
3. Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug
into the positive (+) jack (Ω).
4. Touch the test probe tips to the diode or semiconductor junction you wish to test. Write down the meter
reading.
5. Reverse the probe polarity by switching probe position. Write down this reading.
6. The diode or junction can be evaluated as follows:
A. If one reading shows a value and the other reading shows OL, the diode is good.
B. If both readings show OL, the device is open.
C. If both readings are very low or 0, the device is shorted.
NOTE: The value indicated on the display during the diode check is the forward voltage.
FREQUENCY MEASUREMENT
1. Set the function switch to the Hz% position.
2. Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug
into the positive (+) jack (F).
3. Touch the test probe tips to the circuit under test.
4. Read the frequency on the display. The digital reading will indicate the proper decimal point, symbols (Hz,
kHz) and value.
CAPACITANCE MEASUREMENTS
capacitors before taking any capacitance measurements. Remove the batteries and unplug
the line cords.
1. Set the function sw itch to the CAP position (“nF” and a low value will appear in the display).
2. Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug
into the positive (+) jack (CAP).
Touch the test leads to the capacitor to be tested. The display will indicate the proper decimal point, value
and symbol.
TEMPERATURE MEASUREMENTS
1. If you wish to measure temperature in
temperature in oC, set the function switch to the oC range.
2. Insert the type K thermocouple probe black test lead banana plug into the negative COM jack and the red
test lead banana plug into the positive TEMP jack.
3. Touch the temperature probe head to the part of which you wish to measure the temperature. Keep
touching the part under test until the reading stabilises (about 30 seconds).
Read the temperature on the display. The digital reading will indicate the proper decimal point and value.
DVM9912 VELLEMAN
o
F, set the function switch to the oF range. If you wish to measure
9
BATTERY REPLACEMENT
WARNING
: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the battery door
.
WARNING:
To avoid electric shock, do not operate your meter until the batte
ry door is in place and
fastened securely
.
WARNING
: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the battery door.
WARNING:
To avoid electric shock, do not operate your meter until the battery door is in p
lace and
fastened securely
.
WARNING
: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the fuse door
.
1. When the batteries are exhausted or drop below the operating voltage, “BAT” will appear in the right-hand
side of the LCD display. The battery should be replaced.
2. Follow instructions for installing a battery. See the battery installation section of this manual.
3. Dispose of the old battery properly.
BATTERY INSTALLATION
1. Disconnect the test leads from the meter.
2. Open the battery door by loosening the screw using a Phillips head screwdriver.
3. Insert the battery into battery holder, observing the correct polarity.
4. Put the battery door back in place. Secure with the two screws.
NOTE: If your meter does not work properly, check the fuses and battery to make sure that they are still in
good operating condition and that they are properly inserted.
REPLACING THE FUSES
1. Disconnect the test leads from the meter and any item under test.
2. Open the fuse door by loosening the screw on the door using a Phillips head screwdriver.
3. Remove the old fuse from its holder by gently pulling it out.
4. Install the new fuse into the holder.
5. Always use a fuse of the proper size and value (0.5A/250V fast blow for the 400mA range, 10A/250V fast
blow for the 10A range).
Put the fuse door back in place. Insert the screw and tighten it securely.
WARNING: To avoid electric shock, do not operate your meter until the fuse door is in place and fastened
securely.
DVM9912 VELLEMAN
10
8. Specifications
Compliance EN61010-1
Insulation class 2, double insulation
Overvoltage capacity CATIII 600V
Display 4000 counts LCD with function indication
Polarity automatic, (-) negative polarity indication
Overrange "OL" mark indication
Low Battery indication "BAT" is displayed when the battery voltage drops below the
Measurement rate 2 times per second, nominal
Auto power off meter automatically shuts down after approx. 15 minutes of
Operating environment 0°C to 50° C (32°F to 122°F) at < 70% relative humidity
Storage temperature -20°C to 60° C (-4°F to 140°F) at < 80% relative humidity
Use inside use, max. height 2000m
Pollution degree 2
Power 1 x 9V battery, NEDA 1604, IEC 6F22
Dimensions 150 (H) x 70 (W) x 48 (D) mm
Weight approx. 255g
Accuracy is given at 18°C to 28° C (65°F to 83°F), less than 70% RH
DC Voltage (Autoranging)
Range Resolution Accuracy
400.0mV 0.1mV +0.5% of rdg + 2 dgts
4.000V 1mV
40.00V 10mV
400.0V 100mV
600V 1V +1.5% of rdg + 2 dgts
Input Impedance: 7.8MΩ
Maximum Input: 600VDC or 600VAC rms.
AC Voltage (Autoranging except 400mV)
Range Resolution Accuracy
400.0mV 0.1mV +1.5%of rdg + 15 dgts
4.000V 1mV +1.2% of rdg + 3 dgts
40.00V 10mV
400.0V 100mV
600V 1V +2.0% of rdg + 4 dgts
Input Impedance: 7.8MΩ
Frequency Range: 50 to 400Hz
Maximum Input: 600V DC or 600V ac rms.
DVM9912 VELLEMAN
operating level
inactivity
+1.2% of rdg + 2 dgts
1.5% of rdg + 3 dgts
+
11
DC Current (Autorranging for uA and mA)
Range Resolution Accuracy
400.0uA 0.1uA +1.0% of rdg + 3 dgts
4000uA 1uA
40.00mA 10uA
400.0mA 100uA
10A 10mA +2.5% of rdg + 5 dgts
Overload Protection: 0.5A / 250V and 10A / 250V fuse.
Maximum Input: 400mA DC or 400mA AC rms on uA / mA ranges, 10A DC or AC rms on 10A range.
AC Current (Autoranging for uA and mA)
Range Resolution Accuracy
400.0uA 0.1uA +1.5% of rdg + 5 dgts
4000uA 1uA
40.00mA 10uA
400.0mA 100uA
10A 10mA +3.0% of rdg + 7 dgts
Overload Protection: 0.5A / 250V and 10A / 250V Fuse.
Frequency Range: 50 to 400 Hz
Maximum Input: 400mA DC or 400mA AC rms on uA / mA ranges, 10A DC or AC rms on 10A range.
Resistance (Autoranging)
Range Resolution Accuracy
400.0Ω0.1Ω+1.2% of rdg + 4 dgts
4.000kΩ1Ω+1.0% of rdg + 2 dgts
40.00kΩ10Ω
400.0kΩ100Ω
4.000MΩ1kΩ
40.00MΩ10kΩ+2.0% of rdg + 3 dgts
Input Protection: 250VDC or 250VAC rms.
Capacitance (Autoranging)
Range Resolution Accuracy
4.000nF 1pF +5.0% of rdg+50 dgts
40.00nF 10pF +5.0% of rdg + 7 dgts
400.0nF 0.1nF
4.000uF 1nF
40.00uF 10nF
200.0uF 0.1uF +5.0% of rdg + 5 dgts
Input Protection: 250VDC or 250VAC rms.
DVM9912 VELLEMAN
+1.5% of rdg + 3 dgts
+1.8% of rdg + 5 dgts
+1.2% of rdg + 2 dgts
+3.0% of rdg + 5 dgts
12
Frequency (Autoranging)
Range Resolution Accuracy
9.999Hz 0.001Hz
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
999.9kHz 100Hz
9.999MHz 1kHz +1.5% of rdg + 4 dgts
Sensitivity: >0.5V RMS while ≤1MHz;
Sensitivity: >3V RMS while >1MHz;
Overload protection: 250VDC or AC rms.
Duty Cycle
Range Resolution Accuracy
0.1%~99.9% 0.1% +1.2% of rdg + 2 dgts
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 150kHz
Sensitivity: >0.5V RMS
Overload protection: 250V DC or AC rms.
Temperature
Range Resolution Accuracy
-20oC~+760oC 1 oC
-4 oF~+1400 oF 1oF
Sensor: Type K Thermocouple
Overload protection: 250VDC or AC rms.
Diode Test
Test current Resolution Accuracy
0.3mA typical 1 mV +10% of rdg + 5 dgts
Open circuit voltage: 1.5V DC typical
Overload protection: 250V DC or AC rms.
Audible Continuity
Audible threshold: Less than 150Ω
Test current: <0.3mA
Overload protection: 250V DC or AC rms.
For more info concerning this product, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.
DVM9912 VELLEMAN
+1.5% of rdg + 5 dgts
+1.2% of rdg + 3 dgts
+3% of rdg
+5 oC/9 oF
13
DVM9912 –MULTIMETER MET AUTOMATISCHE BEREIKINSTELLING
1. Inleiding
Aan alle ingezetenen van de Europese Unie
Belangrijke milieu-informatie betreffende dit product
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt
weggeworpen, dit toestel schade kan toebrengen aan het milieu.
Gooi dit toestel (en eventuele batterijen) niet bij het gewone huishoudelijke afval; het moet bij een
gespecialiseerd bedrijf terechtkomen voor recyclage.
U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt brengen.
Respecteer de plaatselijke milieuwetgeving.
Hebt u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.
Dank u voor uw aankoop! Lees deze handleiding grondig voor u het toestel in gebruik neemt. Werd het toestel
beschadigd tijdens het transport, installeer het dan niet en raadpleeg uw dealer.
2. Informatie omtrent de veiligheid
Respecteer volgende punten om de maximale veiligheid gedurende het gebruik te garanderen.
• Gebruik de meter niet wanneer de meter of de meetsnoeren sporen van beschadiging vertonen of de meter
niet naar behoren functioneert.
• Isoleer uzelf tijdens metingen. Raak nooit metalen buizen, toestellen enz. aan die potentieel gevaarlijk
kunnen zijn. Draag droge kledij en rubberen schoenen of sta op een rubberen mat.
• Ontkoppel het te testen toestel van het lichtnet alvorens het circuit te onderbreken. Zelfs een kleine
stroomstoot kan gevaarlijk zijn.
• Wees voorzichtig wanneer u spanningen van 60VDC / 30VAC rms of meer werkt om elektroshocks te
vermijden.
• Houd uw vingers achter de bescherming wanneer u de meetsnoeren gebruikt.
• Het meten van spanningen hoger dan de toegestane maxima kunnen de multimeter beschadigen en de
gebruiker aan elektroshocks blootstellen. Houd u aan de toegestane maximale waarden.
• Meet geen spanningen of stroom hoger dan de vermelde maxima:
Ingang
Functie Max. uitgang
VDC of VAC 600VDC, 600VAC
mA DC/AC 400mA DC/AC
A DC/AC 10A DC/AC (max. 30 seconden elke 15 minuten)
Frequentie, weerstand, capaciteit, duty cycle,
diodetest, continuïteit
Temperatuur 250V DC/AC
250V DC/AC
DVM9912 VELLEMAN
14
3. Veiligheidssymbolen
WARNING
WAARSCHUWING:
Elektroshocks. Hoge spanningen, zowel AC als DC, zijn zeer gevaarlijk. Wees
CAUTION
4. Omschrijving
1. LCD (4000 punten) met symbolen
2. Draaischakelaar
3. 10A (pos itief) ingang voor 10A DC of AC metingen
4. COM (negatief) ingang
5. positieve ingang
6. MODE druk knop
7. RANGE drukknop
8. DATA HOLD drukknop
9. RELATIVE druk knop
5. Symbolen en aanduidingen
BAT Zwakke batterij
DATA HOLD Data Hold
AUTO Automatische bereikinstelling
AC Wisselstroom of –spanning
DC Gelijkstroom of –spanning
Dit symbool naast een ander symbool, terminal of toestel geeft aan dat de
gebruiker aandacht moet schenken aan de instructies in de handleiding om
kwetsuren en beschadiging aan de meter te vermijden.
Geeft een gevaarlijke situatie weer en kan tot kwetsuren leiden of de dood tot
gevolg hebben.
Geeft een gevaarlijke situatie weer en kan tot beschadiging van de meter leiden.
Vermijd aansluitingen aan een circuit met een spanning hoger dan 500 VAC of
VDC.
Gevaarlijke spanning. Vermijd gebruik van de meter en meetsnoeren voor uw
eigen veiligheid.
Continuïteit
Diode
6. Gebruik
voorzichtig tijdens metingen.
1. Plaats de draaischakelaar ALTIJD op OFF wanneer het toestel niet wordt gebruikt. Deze meter is uitgerust
met een automatische uitschakeling na 15 minuten.
2. Wanneer “OL” tijdens een meting op de display verschijnt, dan overschrijdt u het gekozen bereik. Kies een
hoger bereik.
DVM9912 VELLEMAN
15
OPMERKING: Het is mogelijk dat, wanneer de meetsnoeren niet in de meter zitten, het LCD-scherm een
OPGELET:
Verricht geen gelijkspanningsmetingen terwijl u de motor van een circuit in
-
of uitscha
k
elt.
MODE
Selecteren van diode/continuïteit, DC/AC, Hz/%Duty
RANGE
Wanneer u de meter voor het eerst inschakelt, dan stelt hij zich automatisch in de autoranging mode. Deze
modus selecteert automatisch het meest geschikte bereik voor uw meting en is doorgaans de beste
meetinstelling. Ga als volgt te werk wanneer u manueel het bereik wenst in te stellen:
1. Druk op RANGE. “AUTO” verdwijnt van de LCD.
2. Druk op RANGE om de beschikbare bereiken weer te geven en selecteer het gewenste bereik.
3. Houd RANGE gedurende 2 seconden ingedrukt om de manuele instellingsmodus te verlaten en om naar
DATA HOLD
Met deze functie kunt u de weergegeven waarde op het scherm vastzetten en als referentie gebruiken.
1. Druk op DATA HOLD om de waarde vast te zetten. “HOLD” verschijnt op het scherm.
2. Druk opnieuw op DATA HOLD om naar de normale gebruikersmodus terug te keren.
RELATIVE
Met deze kunt u metingen verrichten en deze vergelijken met een opgeslagen waarde. U kunt een
referentiewaarde, bvb. een spanning, stroom enz. opslaan en metingen verrichten. De weergegeven waarde is
het verschil tussen de referentie en de meting.
1. Verricht een meting zoals beschreven in deze handleiding.
2. Druk op RELATIVE om deze waarde op te slaan. “REL” verschijnt op de LCD.
3. De LCD geeft nu het verschil tussen de opgeslagen referentiewaarde en de gemeten waarde.
4. Druk op RELATIVE om naar de normale gebruikersmodus terug te keren.
7. Metingen
METEN VAN GELIJKSPANNINGEN
willekeurige en wisselende waarde weergeeft, meestal in de lage wisselspannings- en
gelijkspanningsbereiken. Dit is normaal en is te wijten aan de gevoeligheid. De waarde
stabiliseert zich en wordt nauwkeurig wanneer u de meetsnoeren aan een circuit sluit.
de autoranging terug te keren.
Hoge spanningspieken kunnen de meter beschadigen.
DVM9912 VELLEMAN
16
1. Plaats de draaischakelaar op V (“mV” verschijnt op de LCD). De meter kiest automatisch DC.
WAARSCHUWING:
Gevaar voor elektroshocks. Het is mogelijk dat de sondes t
e kort zijn en u de te
OPGELET:
Verricht geen gelijkspanningsmetingen terwijl u de motor van een circuit in
-
of uitscha
k
elt.
OPGELET:
Verricht geen metingen gedurende langer dan 30 seconden met een bereik van 10
A
om
2. Koppel het zwarte meetsnoer met de negatieve (COM) bus en het rode meetsnoer met de positieve (V) bus.
3. Raak het te testen circuit met de sondes. Respecteer de polariteit (rode meetsnoer naar positief, zwarte
meetsnoer naar negatief).
4. Lees de weergegeven waarde. De LCD geeft het decimale punt en de waarde weer. Werd de polariteit
omgekeerd, dan verschijnt (-) op de LCD.
METEN VAN WISSELSPANNINGEN
meten contactpunten in enkele 240V-toestellen niet kunt bereiken. De waarde op
de LCD is dan 0V, ook al staat het toestel onder spanning. Zorg ervoor dat de
sondes het circuit raken alvorens te concluderen dat het toestel niet onder
spanning staat.
Hoge spanningspieken kunnen de meter beschadigen.
1. Plaats de draaischakelaar op V. Druk op MODE om AC te selecteren.
2. Koppel het zwarte meetsnoer met de negatieve (COM) bus en het rode meetsnoer met de positieve (V)
bus.
3. Raak het te testen circuit met de sondes.
4. Lees de weergegeven waarde. De LCD geeft het decimale punt, de waarde en het symbool (AC, V enz.)
weer.
METEN VAN GELIJKSTROOM
beschadiging aan de meter en/of meetsnoeren te vermijden.
1. Koppel het zwarte meetsnoer met de negatieve (COM) bus.
2. Voor gelijkstroommetingen tot 4000µ A, plaats de draaischakelaar op µ A en koppel het rode meetsnoer met
de (µ A) bus.
3. Voor gelijkstroommetingen tot 400mA, plaats de draaischakelaar op mA en koppel het rode meetsnoer met
de (mA) bus.
4. Voor gelijkstroommetingen tot 10A, plaats de draaischakelaar op A en Koppel het rode meetsnoer met de
10A-bus.
5. Druk op MODE tot “DC” op de LCD verschijnt.
6. Schak el de voeding van het te testen circuit uit. Onderbreek het circuit en verricht de meting.
7. Raak de negatieve zijde van het circuit met het zwarte meetsnoer. Raak de positieve zijde met het rode
meetsnoer.
8. Schak el de voeding in.
9. Lees de weergegeven waarde. De LCD geeft het decimale punt, de waarde en het symbool weer.
DVM9912 VELLEMAN
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.