VEGA SON83 User Manual

VEGASON 83 … 87
ECHOFOX
®
TIB • Technical Information • Operating Instructions
Pulse-echo sensors
Digital transmission of measuring data
Approvals for
- hazardous areas acc. to
- CENELEC
- ElexV Zone 0
Compact instrument
Current output 0 … 20 mA Approval for
VEGA Grieshaber KG
Am Hohenstein 113 D-77761 Schiltach Phone 0 78 36 / 50 - 0 Fax 0 78 36 / 50 201
2
VEGASON 83 … 87
Contents
Contents
1 Introduction
1.1 Contents of the instruction manual .....................................................................................................................4
1.2 Safety information ...............................................................................................................................................4
2 Product description
2.1 Function and configuration ..................................................................................................................................4
2.2 Types and versions .............................................................................................................................................5
2.3 Configuration of a measuring system, sensor in not-Ex-area .............................................................................8
2.4 Configuration of a measuring system, sensor in Ex-area ................................................................................... 9
2.5 Order code for sensors .....................................................................................................................................10
2.6 Technical data of the sensors............................................................................................................................11
2.7 Configuration with compact instrument .............................................................................................................14
2.8 Order code for compact instrument...................................................................................................................15
2.9 Technical data of compact instruments .............................................................................................................16
2.10 Dimensional drawings .......................................................................................................................................18
2.11 Approvals ..........................................................................................................................................................22
3 Environment
3.1 Installation recommendations relating to liquid tank / vessels ..........................................................................23
3.2 Installation recommendations relating to solid silos ..........................................................................................25
4 Electrical connection
4.1 Connection example of sensors ........................................................................................................................26
4.2 Connection example of Ex-sensors ..................................................................................................................27
4.3 Connection example of compact instruments ...................................................................................................29
5 Set-up
5.1 Sensor and signal conditioning instrument (e.g. VEGAMET) ...........................................................................30
5.2 Sensor and processing system (VEGALOG 571) .............................................................................................30
5.3 Compact instrument.......................................................................................................................................... 30
VEGASON 83 … 87
3
1 Introduction / 2 Product description
1 Introduction
1.1 Contents of the instruction manual
The Technical Information / Operating Instructions is called TIB. It contains all necessary information for correct
- installation
- connection
- set-up
- optimization of the pulse-echo-sensors VEGASON …. V… or pulse­echo compact instrument VEGASON … K….
VEGA regularly revises the contents of TIBs as technical improvements are made to the instruments.
1.2 Safety information
The described module must only be inserted and operated as described in this TIB. Please note that other action can cause damage for which VEGA does not take responsibility.
2 Product description
2.1 Function and configuration
Function
The VEGASON … sensor systems or compact instruments are used for continuous and non-contact level measurement.
Short sound impulse packets are emitted by the transducer of the pulse-echo sensor. The combined emitter and receiver system detects the pulses reflected by the product.
The running period of the ultrasonic pulses is directly pro­portional to the distance between sensor and measured product.
The signal processing ECHOFOX of signal analysis to process the reflected ultrasonic pulses.
®
uses modern methods
The signal-to noise ratio is optimized by digital signal processing methods with mathematic algorithms (DSP).
The automatic configuration of a user specific data base enables an optimum adaption to the respective application.
The use of fuzzy-logic for echo evaluation ensures a reliable determination of the level. False echoes, e.g. from stirrers or other installations are detected and are not included in the generation of the measured value.
These measuring data are transmitted digitally to respective signal conditioning instruments or processing systems and processed.
The operation of the sensors is made via the signal conditioning instrument VEGAMET or via a PC (VEGACONNECT necessary).
Compact instruments are additionally equipped with an integral output of the measuring data and make a current output 0 … 20 mA available.
The operation of the compact instrument is only possible with PC via VEGACONNECT.
Configuration
Flange version
The sensor or compact instruments consist of a housing, integrated therein the above electronics and all required terminals, a mounting flange and a transducer.
Housing, flange and transducer are designed acc. to the type.
Separate version
The separate version consists of a housing with integral electronics and all necessary terminal and mounting plate.
Transducer with mounting tube and connection cable as separate modular unit. The transducers differ acc. to the various types.
4
VEGASON 83 … 87
2 Product description
2.2 Types and versions
VEGASON 83 FK VEGASON 83 FV
Flange version with flange size DN 100, transducer inte­gral in flange, plastic housing with integral ECHOFOX sensor electronics.
Suitable for a number of applications and mounting positions,
- mounting directly on the vessel ceiling (tank, silo) or on existing sockets
- positioning on fix points above the vessels etc.
Measuring range 0,7 m … 10 m (see section 3 Evironment).
VEGASON 83 FV Ex, 83 FV Ex 0
®
-
VEGASON 84 FK VEGASON 84 FV
Flange version with flange size DN 150, transducer below the flanges, plastic housing with integral ECHOFOX sensor electronics.
Suitable for a number of applications and mounting positions,
- mounting directly on the vessel ceiling (tank, silo) or on existing sockets
- positioning on fix points above the vessel etc.
Measuring range 0,7 m … 20 m (see section 3 Environment).
®
-
VEGASON 84 FK StEx VEGASON 84 FV StEx
as VEGASON 83 FV, however housing of sensor electronics and transducer made of stainless steel 1.4305
Suitable for the use in hazardous areas (see section 2.11 Approvals).
VEGASON 83 FV Ex B, 83 FV Ex0 B
as VEGASON 83 FV Ex or FV Ex 0, however with integral overvoltage arrester of sensor electronics.
as VEGASON 84 FK or FV , however additionally approved for the use in dust-Ex areas StEx (see section 2.11 Approvals).
VEGASON 84 FV Ex, 84 FV Ex 0
Flange version with flange size DN 150, transducer inte­gral in flange, housing of sensor electronics and transducer made of stainless steel 1.4305.
Suitable for the use in hazardous areas (see section 2.11 Approvals).
VEGASON 83 … 87
5
2 Product description
VEGASON 84 FV Ex B, 84 FV Ex0 B
as VEGASON 84 FV Ex or FV Ex 0, however with integral overvoltage arrester of sensor electronics.
Compact instrument VEGASON 85 FK
VEGASON 85 FV
VEGASON 87 FK VEGASON 87 FV
Flange version, flange size ø 450 mm, triple transducer divided into emission and receipt unit, reset as described under VEGASON 85 FV . Measuring range 0,4 m … 60 m (see section 3 Environment).
VEGASON 87 FK StEx VEGASON 87 FV StEx
Flange version with flange size DN 150, transducer below the flanges, plastic housing with integral ECHOFOX sensor electronics.
Suitable for a number of applications and mounting positions,
- mounting directly on the vessel ceiling (tank, silo) or on existing sockets
- positioning on fix points above the vessels etc.
Measuring range 1,0 m … 30 m (see section 3 Environment).
®
-
VEGASON 85 FK StEx VEGASON 85 FV StEx
as VEGASON 85 FK or FV , however additionally approved for the use in dust-Ex areas StEx (see section 2.11 Approvals).
as VEGASON 87 FK or FV , however additionally approved for the use in dust-Ex areas StEx (see section 2.11 Approvals).
6
VEGASON 83 … 87
2 Product description
VEGASON 83 GK VEGASON 83 GV
Separate version, transducer and housing are separated. An ECHOFOX housing. The transducer is provided with a fixing tube (thread G 1). It can be mounted in a small hole (ø 35 mm) at the vessel ceiling (tank/silo). As option the transducer can be screwed with a swivelling holder (DN 150) and can be optimally adapted to the installation conditions. Measuring range 0,7 m … 10 m (see section 3 Environment).
®
-sensor electronics is integrated in the
VEGASON 84 GK VEGASON 84 GV
as VEGASON 83 GKor GV, however measuring range 0,7 m … 20 m
VEGASON 84 GK StEx VEGASON 84 GV StEx
as above, however additionally approved for the use in dust-Ex areas StEx (see section 2.11 Approvals).
VEGASON 85 GK VEGASON 85 GV
as VEGASON 83 GK or GV , however measuring range 1,0 m … 30 m
VEGASON 85 GK StEx VEGASON 85 GV StEx
as above, however additionally approved for the use in dust-Ex areas StEx (see section 2.11 Approvals).
VEGASON 87 GK VEGASON 87 GV
as VEGASON 83 GK or GV, however triple transducer divided into emission and receipt unit, rest as described under measuring range 0,4 m … 60 m
VEGASON 87 GK StEx VEGASON 87 GV StEx
as above, however additionally approved for the use in dust-Ex areas StEx (see section 2.11 Approvals).
6
VEGASON 83 … 87
7
2 Product description
11
11 … 15
6 … 10
1 … 5
4
2.3 Configuration of a measuring system, sensor in not-Ex-area
Generally a measuring system consists of two components
- a local sensor and
- a signal conditioning instrument or processing system
The kind of signal conditioning instrument or processing system depends on the installation conditions.
Sensor(s) VEGASON 83 … 87
Signal conditioning instrument e.g. VEGAMET 514 V (VEGAMET 407 V)
Processing system VEGALOG 571
VEGACONNECT
RS 232
PC
EV -input card (via additionally EV-input cards max. 3 x 5 = 15 sensors each can be connected)
CPU-central unit
Sensor(s) and signal conditioning instrument or processing system are connected via a two-wire line. The power supply of the sensor or the sensors is ensured via this line and the measuring data are transmitted digitally to the signal conditioning instrument or processing system.
The indicating and operating surface VEGA Visual Operating, installed on a PC ensures a simple and comfortable configuration and parameter adjustment of the respective measuring system.
VEGACONNECT can be connected to respective sockets of the signal conditioning instrument or the sensor. If neces­sary, it is possible to connect VEGACONNECT directly to the two-wire line (signal conditioning instrument … sensor).
8
VEGASON 83 … 87
2 Product description
2.4 Configuration of a measuring system, sensor in Ex-area
In this application a measuring system consists of three components
- a local Ex-sensor in the Ex-area
- a safety barrier and
- a signal conditioning instrument or processing system in the not-Ex-area
The kind of signal conditioning instrument or processing system mainly depends on the control and process technical requirements.
Sensor(s) VEGASON 83 und 84
Separator Type 146 or VEGATRENN 546
Signal conditioning instrument e.g. VEGAMET 514 V (VEGAMET 407 V)
4
1
1
1
Not-Ex-area
Ex-area
Processing system VEGALOG 571
RS 232
1 … 5
4
1 … 5
6 … 10
4
4 4
6 … 10
usw.
etc.
etc.
1. EV-input card 2. EV-input card
VEGACONNECT
(via additionally EV-input card 5 sensors each can be connected)
CPU-central unit
4
PC
Each sensor is connected to the respective signal conditioning instrument or processing system via a separator type 146 or VEGATRENN 546. The separator provides two intrinsically safe circuits. These circuits provide the power supply of the sensor and the digital transmission of measuring data to the signal conditioning instrument or processing system.
The indicating and operating surface VEGA Visual Operating, installed on a PC ensures a simple and comfortable configuration and parameter adjustment of the respective measuring system.
VEGASON 83 … 87
9
2.5 Order code for sensors
2.5.1 VEGASON …V / …V StEx
Type Measuring range
8 3 .................. 0,7 … 10 m
8 4 .................. 0,7 … 20 m
8 5 .................. 1,0 … 30 m
8 7 .................. 0,4 … 60 m
Version
F Flange version G Separate version
Approvals
. X without
EXS. XStEx for Zone 10 (only for VEGASON 84 … 87)
2 Product description
Flange size
E DN 100 PN 16 (for VEGASON 83) F DN 150 PN 16 (for VEGASON 84 and 85) U ø 450 (for VEGASON 87) Y Others
Flange material
A Aluminium (for StEx-version) P PPh Y Others
S O N V E Z Order no. for VEGASON … V
2.5.2 VEGASON … FV Ex…
Type Measuring range
8 3 F V E X CENELEC EEx d e ia IIB T6 .......... 0,7 … 10 m
8 3 F V E X 0 PTB Zone 0 EEx d e ia IIB T6 ........ 0,7 … 10 m
8 4 F V E X CENELEC EEx d e ia IIB T6 .......... 1,1 … 20 m
8 4 F V E X 0 PTB Zone 0 EEx d e ia IIB T6 ........ 1,1 … 20 m
Options
X without B with overvoltage arrester
S O N . X V V V Order no. for VEGASON … FV Ex…
10
VEGASON 83 … 87