1.1Contents of the instruction manual .....................................................................................................................4
1.2Safety information ...............................................................................................................................................4
2 Product description
2.1Function and configuration ..................................................................................................................................4
2.2Types and versions .............................................................................................................................................5
2.3Configuration of a measuring system, sensor in not-Ex-area .............................................................................8
2.4Configuration of a measuring system, sensor in Ex-area ................................................................................... 9
2.5Order code for sensors .....................................................................................................................................10
2.6Technical data of the sensors............................................................................................................................11
2.7Configuration with compact instrument .............................................................................................................14
2.8Order code for compact instrument...................................................................................................................15
2.9Technical data of compact instruments .............................................................................................................16
3.1Installation recommendations relating to liquid tank / vessels ..........................................................................23
3.2Installation recommendations relating to solid silos ..........................................................................................25
4 Electrical connection
4.1Connection example of sensors ........................................................................................................................26
4.2Connection example of Ex-sensors ..................................................................................................................27
4.3Connection example of compact instruments ...................................................................................................29
5 Set-up
5.1Sensor and signal conditioning instrument (e.g. VEGAMET) ...........................................................................30
5.2Sensor and processing system (VEGALOG 571) .............................................................................................30
The Technical Information / Operating Instructions is
called TIB. It contains all necessary information for correct
- installation
- connection
- set-up
- optimization
of the pulse-echo-sensors VEGASON …. V… or pulseecho compact instrument VEGASON … K….
VEGA regularly revises the contents of TIBs as technical
improvements are made to the instruments.
1.2Safety information
The described module must only be inserted and operated
as described in this TIB. Please note that other action can
cause damage for which VEGA does not take
responsibility.
2Product description
2.1Function and configuration
Function
The VEGASON … sensor systems or compact
instruments are used for continuous and non-contact level
measurement.
Short sound impulse packets are emitted by the
transducer of the pulse-echo sensor. The combined
emitter and receiver system detects the pulses reflected
by the product.
The running period of the ultrasonic pulses is directly proportional to the distance between sensor and measured
product.
The signal processing ECHOFOX
of signal analysis to process the reflected ultrasonic
pulses.
®
uses modern methods
The signal-to noise ratio is optimized by digital signal
processing methods with mathematic algorithms (DSP).
The automatic configuration of a user specific data base
enables an optimum adaption to the respective
application.
The use of fuzzy-logic for echo evaluation ensures a
reliable determination of the level. False echoes, e.g. from
stirrers or other installations are detected and are not
included in the generation of the measured value.
These measuring data are transmitted digitally to
respective signal conditioning instruments or processing
systems and processed.
The operation of the sensors is made via the signal
conditioning instrument VEGAMET or via a PC
(VEGACONNECT necessary).
Compact instruments are additionally equipped with an
integral output of the measuring data and make a current
output 0 … 20 mA available.
The operation of the compact instrument is only possible
with PC via VEGACONNECT.
Configuration
Flange version
The sensor or compact instruments consist of a housing,
integrated therein the above electronics and all required
terminals, a mounting flange and a transducer.
Housing, flange and transducer are designed acc. to the
type.
Separate version
The separate version consists of a housing with integral
electronics and all necessary terminal and mounting plate.
Transducer with mounting tube and connection cable as
separate modular unit. The transducers differ acc. to the
various types.
4
VEGASON 83 … 87
2 Product description
2.2Types and versions
VEGASON 83 FK
VEGASON 83 FV
Flange version with flange size DN 100, transducer integral in flange, plastic housing with integral ECHOFOX
sensor electronics.
Suitable for a number of applications and mounting
positions,
- mounting directly on the vessel ceiling (tank, silo) or on
existing sockets
- positioning on fix points above the vessels etc.
Measuring range 0,7 m … 10 m
(see section 3 Evironment).
VEGASON 83 FV Ex, 83 FV Ex 0
®
-
VEGASON 84 FK
VEGASON 84 FV
Flange version with flange size DN 150, transducer below
the flanges, plastic housing with integral ECHOFOX
sensor electronics.
Suitable for a number of applications and mounting
positions,
- mounting directly on the vessel ceiling (tank, silo) or on
existing sockets
- positioning on fix points above the vessel etc.
Measuring range 0,7 m … 20 m
(see section 3 Environment).
®
-
VEGASON 84 FK StEx
VEGASON 84 FV StEx
as VEGASON 83 FV, however housing of sensor
electronics and transducer made of stainless steel 1.4305
Suitable for the use in hazardous areas (see section 2.11
Approvals).
VEGASON 83 FV Ex B, 83 FV Ex0 B
as VEGASON 83 FV Ex or FV Ex 0, however with integral
overvoltage arrester of sensor electronics.
as VEGASON 84 FK or FV , however additionally approved
for the use in dust-Ex areas StEx (see section 2.11
Approvals).
VEGASON 84 FV Ex, 84 FV Ex 0
Flange version with flange size DN 150, transducer integral in flange, housing of sensor electronics and
transducer made of stainless steel 1.4305.
Suitable for the use in hazardous areas (see section 2.11
Approvals).
VEGASON 83 … 87
5
2 Product description
VEGASON 84 FV Ex B, 84 FV Ex0 B
as VEGASON 84 FV Ex or FV Ex 0, however with integral
overvoltage arrester of sensor electronics.
Compact instrument
VEGASON 85 FK
VEGASON 85 FV
VEGASON 87 FK
VEGASON 87 FV
Flange version, flange size ø 450 mm, triple transducer
divided into emission and receipt unit, reset as described
under VEGASON 85 FV .
Measuring range 0,4 m … 60 m
(see section 3 Environment).
VEGASON 87 FK StEx
VEGASON 87 FV StEx
Flange version with flange size DN 150, transducer below
the flanges, plastic housing with integral ECHOFOX
sensor electronics.
Suitable for a number of applications and mounting
positions,
- mounting directly on the vessel ceiling (tank, silo) or on
existing sockets
- positioning on fix points above the vessels etc.
Measuring range 1,0 m … 30 m
(see section 3 Environment).
®
-
VEGASON 85 FK StEx
VEGASON 85 FV StEx
as VEGASON 85 FK or FV , however additionally approved
for the use in dust-Ex areas StEx (see section 2.11
Approvals).
as VEGASON 87 FK or FV , however additionally approved
for the use in dust-Ex areas StEx (see section 2.11
Approvals).
6
VEGASON 83 … 87
2 Product description
VEGASON 83 GK
VEGASON 83 GV
Separate version, transducer and housing are separated.
An ECHOFOX
housing. The transducer is provided with a fixing tube
(thread G 1). It can be mounted in a small hole (ø 35 mm)
at the vessel ceiling (tank/silo).
As option the transducer can be screwed with a swivelling
holder (DN 150) and can be optimally adapted to the
installation conditions.
Measuring range 0,7 m … 10 m
(see section 3 Environment).
®
-sensor electronics is integrated in the
VEGASON 84 GK
VEGASON 84 GV
as VEGASON 83 GKor GV, however
measuring range 0,7 m … 20 m
VEGASON 84 GK StEx
VEGASON 84 GV StEx
as above, however additionally approved for the use in
dust-Ex areas StEx (see section 2.11 Approvals).
VEGASON 85 GK
VEGASON 85 GV
as VEGASON 83 GK or GV , however
measuring range 1,0 m … 30 m
VEGASON 85 GK StEx
VEGASON 85 GV StEx
as above, however additionally approved for the use in
dust-Ex areas StEx (see section 2.11 Approvals).
VEGASON 87 GK
VEGASON 87 GV
as VEGASON 83 GK or GV, however triple transducer
divided into emission and receipt unit, rest as described
under
measuring range 0,4 m … 60 m
VEGASON 87 GK StEx
VEGASON 87 GV StEx
as above, however additionally approved for the use in
dust-Ex areas StEx (see section 2.11 Approvals).
6
VEGASON 83 … 87
7
2 Product description
11
11 … 15
6 … 10
1 … 5
4
2.3Configuration of a measuring system, sensor in not-Ex-area
Generally a measuring system consists of two components
- a local sensor and
- a signal conditioning instrument or processing system
The kind of signal conditioning instrument or processing system depends on the installation conditions.
Sensor(s)
VEGASON 83 … 87
Signal conditioning
instrument e.g.
VEGAMET 514 V
(VEGAMET 407 V)
Processing system
VEGALOG 571
VEGACONNECT
RS
232
PC
EV -input card
(via additionally EV-input cards max. 3 x 5 = 15 sensors
each can be connected)
CPU-central unit
Sensor(s) and signal conditioning instrument or processing system are connected via a two-wire line. The power supply
of the sensor or the sensors is ensured via this line and the measuring data are transmitted digitally to the signal
conditioning instrument or processing system.
The indicating and operating surface VEGA Visual Operating, installed on a PC ensures a simple and comfortable
configuration and parameter adjustment of the respective measuring system.
VEGACONNECT can be connected to respective sockets of the signal conditioning instrument or the sensor. If necessary, it is possible to connect VEGACONNECT directly to the two-wire line (signal conditioning instrument … sensor).
8
VEGASON 83 … 87
2 Product description
2.4Configuration of a measuring system, sensor in Ex-area
In this application a measuring system consists of three components
- a local Ex-sensor in the Ex-area
- a safety barrier and
- a signal conditioning instrument or processing system in the not-Ex-area
The kind of signal conditioning instrument or processing system mainly depends on the control and process technical
requirements.
Sensor(s)
VEGASON 83 und 84
Separator Type 146 or
VEGATRENN 546
Signal conditioning
instrument e.g.
VEGAMET 514 V
(VEGAMET 407 V)
4
1
1
1
Not-Ex-area
Ex-area
Processing system
VEGALOG 571
RS
232
1 … 5
4
1 … 5
6 … 10
4
44
6 … 10
usw.
etc.
etc.
1. EV-input card2. EV-input card
VEGACONNECT
(via additionally EV-input card 5 sensors each can be connected)
CPU-central unit
4
PC
Each sensor is connected to the respective signal conditioning instrument or processing system via a separator type 146
or VEGATRENN 546. The separator provides two intrinsically safe circuits. These circuits provide the power supply of the
sensor and the digital transmission of measuring data to the signal conditioning instrument or processing system.
The indicating and operating surface VEGA Visual Operating, installed on a PC ensures a simple and comfortable
configuration and parameter adjustment of the respective measuring system.
VEGASON 83 … 87
9
2.5Order code for sensors
2.5.1 VEGASON …V / …V StEx
TypeMeasuring range
8 3.................. 0,7 … 10 m
8 4.................. 0,7 … 20 m
8 5.................. 1,0 … 30 m
8 7.................. 0,4 … 60 m
Version
F Flange version
G Separate version
Approvals
. X without
EXS. XStEx for Zone 10 (only for VEGASON 84 … 87)
2 Product description
Flange size
E DN 100 PN 16 (for VEGASON 83)
F DN 150 PN 16 (for VEGASON 84 and 85)
U ø 450 (for VEGASON 87)
Y Others
Flange material
A Aluminium (for StEx-version)
P PPh
Y Others
S O NVE ZOrder no. for VEGASON … V
2.5.2 VEGASON … FV Ex…
TypeMeasuring range
8 3 F V E XCENELEC EEx d e ia IIB T6 .......... 0,7 … 10 m
8 3 F V E X 0 PTB Zone 0 EEx d e ia IIB T6 ........ 0,7 … 10 m
8 4 F V E XCENELEC EEx d e ia IIB T6 .......... 1,1 … 20 m
8 4 F V E X 0 PTB Zone 0 EEx d e ia IIB T6 ........ 1,1 … 20 m
Options
X without
B with overvoltage arrester
S O N. X V V VOrder no. for VEGASON … FV Ex…
10
VEGASON 83 … 87