VEGA MET515 User Manual

Menu plan
VEGAMET 515
TAG ­No. 1 % 12,3
-
Level and Pressure
%
100
+
ESC
OK
CONNECT
513
out
in
T AG1-3 xx,x
xx,x
xx,x
T AG ­No. 1
%
xx,x
Param.
TAG­No. 1
Adjust ment
TAG ­No. 2
%
xx,x
Param.
T AG­No. 2
like TAG- No.1
Signal condit ioning
TAG ­No. 3
%
xx,x
Param.
T AG­No. 3
Out­puts
mA out­puts
Volt­out­puts
Measured value indication
Sensor­type
hydro­static
Menu plan
Bolt print / italic are the sensor or measured value information which cannot be modified in this position.
with medium
Min adjust at % 0,0
Sca­ling
0% corres ponds 0
Max adjust at % 100,0
mA output no. 1
Prop. to
Per­cent
Lin.­curve
linear
100% corres ponds 1000
Volt output no. 1
Prop. to
Per­cent
mA output no. 2
Unit
0,0%
Integr ation time s 0
Deci­mal point
888,8
w.out medium
Ab­gleich
mA
Volt output no. 2
like Volt-output no.1
Unit
0,0%
mA output no. 3
like mA-output no.1
mA Range
0% +100%
Densi­ty in Kg/dm
3
1,000
Prop. to
unde­find
Offset correc tion
Sensor unpres sur’d ? OK ?
Offset corr. Now ! OK ?
Volt output no. 3
Volt­Range
0% +100%
mA output
4/20mA
DK­Value (Er)
81,00
Unit
– –
0% at
mA
4,000
Volt­age output
0/10V
mA at 0%
4,000
Volts at 0%
0,000
mA at 100%
20,000
Meas. value limita tion
nega­tive Values yes
100% at
mA
20,000
With these keys you move in the menu field
Volts at 100%
10,000
Fail­ure mode
0mA
Fail. mode
Stan­dard
ESC
OK
Fail­ure mode
0V
mA Limita tion
on
Volt­Limita tion
ein
2 VEGAMET 515
Menu plan
Lang­uage
Eng­lish
Relay out­puts
In white letters you see the parameters which can be modified with the + or - key and which can be saved with the OK-key.
MET­Dis­play
Prop. to
Per­cent
Unit
0,0%
PC/DCS out­puts
DIS­out­puts
DIS­outp.1
Prop. to
Per­cent
Simu­lation
Simu­lation Now! OK?
Simu­lation %
XX,X
Unit
0,0%
mA at 100%
20,000
Spe­cial funct.
Reset
level
Reset OK ?
Reset Now!
OK ?
DIS­outp.7
like DIS outp. 1
Light grey menu points are only displayed if necessary (dependent on the adjustments in other menus).
Real value corr. % 0
Densi­ty corr. % 0
DK­corr.
0
%
Manual correc tion
Offset correc tion
Offset correc tion OK?
Correc tion Now ! OK ?
—>
continued
Real value corr.
Real value corr. OK?
Correc tion at % 0,0
Correc tion Now ! OK ?
Unit
0,0%
PC/DCS outp.2
Low %
0,0
like PC/DCS outp. 1
High %
100,0
Deviat ion % 1,0
Deviat ion period
Scan time s 1
Fail­ure mode off
No. of scans 10
Add’l func­tions
Switch ing delay
t on s
0
t off s
0
Relay output no. 1
Prop. to
Per­cent
Relay output no. 2
like Relay outp. 1
Unit
0,0%
Mode
Over­fill protec
PC/DCS outp.1
Prop. to
Per­cent
Monit. on
Low& High
VEGAMET 515 3
< previous page
Confi­gura­tion
Menu plan
Config Inputs
Input no. 1
Input from
local Met
Config Meas. loop
with 2 single measurements
TAG 1
level
Appli­cation
level
2) 2) 2) 2) Input
no. 2
Chan­nel no.
TAG 2
level
like TAG 1
Sensor type
Hydro­static
Input no.4
Input from
local Met
Input no.
unde­fined
S1
with linked application
Appli-
Sen-
cation
sorik
Hydro­static
level
1) 1) 1) 1) The parameters in these menu
1)
points can be only modified when „Reset to linked applicationt“ had been carried out first.
The parameters in these menu
2)
points can be only modified when „Reset to single measurement“ had been carried out first.
Mode
Stan­dard
Input no. 5
like Input no. 4like Input no.1
Chan­nel no. K1
Sensor charac terist ics
Option
no option
Input no.
unde­fined
Mode
press­urized vessel
Sensor coordi nation
Loca­tion A
Input no. 1
Option
no option
TAG-ID
TAG ­No. 1
Loca­tion D
unde­fined
Sensor coordi nation
Loca­tion A
Input no. 1
Fault signal ?
on
Loca­tion E
unde­fined
TAG 1
level
TAG-ID
TAG ­No. 1
Loca­tion B
unde­fined
Tare
Input from
unde­fined
TAG 2
Top press
Fault signal ?
on
Loca­tion C
unde­fined
TAG 3
Total press
like T AG 1
Loca­tion D
unde­fined
Moni­toring
Input from
unde­fined
Tare
Input from
unde­fined
Moni­toring
Input from
unde­fined
Loca­tion E
unde­fined
Min. meas. range 0,00
Max. meas. range 1,00
Min. Sensor value 4,000
Max. Sensor value 20,000
4 VEGAMET 515
Menu plan
Config Out­puts
continued
>
Config curr. output
mA no1 to
T AG ­No. 1
Config Volt. output
V no1 to
TAG ­No. 1
mA no2 to
T AG ­No. 2
Config Relay output
Operat ing relay
Rel. 1 to
T AG ­No. 1
V no2 to
TAG ­No. 2
mA no3 to
TAG ­No. 3
Fail safe relay
Relay
Stan­dard
Rel. 1
Stan­dard
V no3 to
T AG ­No. 2
Config PC/ DCS output
DC/DCS Meas. values
DCS 1 to
TAG ­No. 1
Input no.
unde­fined
DC/DCS Relay status
off
Rel. 2 to
TAG ­No. 2
DCS 7 to
----
DC/ DCS Input status
off
Rel. 2
Stan­dard
Sensor­type
hydro­static
Config VEGA­DIS
DIS 1 to
T AG ­No. 1
Input no.
unde­fined
Bolt print / italic are the sensor or measured value information which cannot be modified in this position.
DIS 7 to
----
In white letters you see the parameters which can be modified with the + or - key and which can be saved with the OK-key.
Light grey menu points are only displayed if necessary (dependent on the adjustments in other menus).
ESC
OK
With these keys you move in the menu field
Lang­uage
Eng­lish
mA at 100%
20,000
VEGAMET 515 5
previous page
<
Add’l func­tions
Menu plan
pass­word
off
Edit lin. curves
Curve no.1
Info Lang-
Meas.
Input info
Input no.1
like Input no.1 like Input no.4
Sensor type
hydro­static
Curve no.2
Input no.2
input from
local MET
Curve no.3
Input no.4
Sensor type
Vibra­tion
Chan­nel no.
Input no.5
Input from
local MET
Input
unde­fined
S1
VEGA­MET Info
Typ MET515
Chan­nel no.
K1
Sensor charac terist ics
Min. meas. range
0,00
Pro­gram info
Pro­gramm info
xxxxxx
Serial number
xxxx
xxxx
Input
unde­fined
Actual sensor value
xx,xxx
Max. meas. range
1,00
loop Info
TAG 1
TAG ­No. 1
Min set at %
0,0
Instr. addr.
Actual switch status
1
Min. Sensor value
4,000
Min set at
mA
4,000
Softw. Vers.
1.13
uage
Eng­lish
Max. Sensor value
20,000
Max set at %
100,0
Softw. Date
47/97
Max set at
mA
20,000
Param. Vers.
5
Para­meter
level
like Curve no. 1
Add Lin.­point
x % 0,0 y V% 0,0
Edit curve no.1
x
0 %
0,0
y 0 V% 0,0
x 1 %
x 2 %
100,0
y 1 V% 100,0
100,0
y 2 V% 100,0
Index marker number (0...32)
x32 %
100,0
y32 V% 100,0
Delete Lin.­point
x 0,0 y 0,0
delete
delete Now?
x100,0 y100,0
delete
delete Now?
6 VEGAMET 515
Menu plan
Reset VEGA­MET
Reset Confi­gura­tion
to De­fault
Reset
OK?
Reset Now!
OK?
to linked appli­cat
Delete all TAG’s ?
Reset
OK?
Reset Now!
OK?
to single meas.
Reset T AG1
Delete TAG1?
Reset
OK?
Reset Now!
OK?
Reset TAG2
Delete T AG2?
Reset
OK?
Reset Now!
OK?
Reset Sensor charac
Reset Input1
Reset
OK?
Reset Now!
OK?
Ser­vice
only accessible with service password
Reset
Reset
Input2
all curves
Delete
Reset
all curves?
OK?
Reset
Reset Now!
OK?
OK?
Reset Now!
OK?
Reset lin. curves
Reset curve no.1
Reset
OK?
Reset Now
OK?
Sensor­type
hydro­static
Reset curve no.2
Reset
OK?
Reset Now!
OK?
Bolt print / italic are the sensor or measured value information which cannot be modified in this position.
curve no.3
Reset
OK?
Reset Now!
OK?
all curves
Delete all curves?
Reset
OK?
Reset Now!
OK?
Reset
Reset
In white letters you see the parameters which can be modified with the + or - key and which can be saved with the OK-key.
Light grey menu points are only displayed if necessary (dependent on the adjustments in other menus).
ESC
OK
With these keys you move in the menu field
Lang­uage
Eng­lish
mA at 100%
20,000
VEGAMET 515 7
VEGA Grieshaber KG Am Hohenstein 113 D-77761 Schiltach Phone (0 78 36) 50 - 0 Fax (0 78 36) 50 - 201 e-mail vega@vega-g.de
ISO 9001
Technical data subject to alterations 2.22 282 / Jan. 98
Loading...