Reduced menu
For adjustment of the signal conditioning instruments VEGAMET 514 V two menus are
available:
the „Reduced menu“ and the „Extended menu“ (see following pages).
As factory setting „Reduced menu“ is activated.
The most important adjustment steps (e.g. adjustment, adjustment integration time,
simulation...) can be carried out in the „Reduced menu“.
When you want to move to the „Extended menu“ (e.g. to edit linearisation curves) proceed as
follows:
– Move with the OK-key and the arrow keys to the menu point „Menu mode reduced“.
– Push the + key twice.
– The display shows now „Menu mode extended“.
– Now push the OK-key to save the adjustment.
In white letters
Lang-
you see the
uage
parameters which
Eng-
can be modified
lish
and which can be saved with
the OK-key.
with the + or - key
ESC
OK
Bolt print / italic are
Param.
the sensor or
TAG-
measured value
No. 1
information which
Relay
outp. 2
cannot be
Light grey menu points
are only displayed if
necessary (dependent
on the adjustments in
other menus).
modified in this position.
With these keys you move in
the menu field
2 VEGAMET 514V
Reduced menu
TAGNo. 1
%
xx,x
Param.
TAGNo. 1
Adjust
ment
TAGNo. 2
°C
xx,x
Configuration
Sensor
type
Hydro
static
The sensor type can be only
modified when „Reset TAG 1“
had been carried out before.
Signal
conditioning
Scaling
Measured
TAG1-2
value indication
xx,x
xx,x
Add’l
functions
Pass-
Lang-
word
uage
English
off
TAG-ID
Sensor
optimize
TAG No. 1
Sensor menu
(see operating
instruction of the
sensor)
Outputs
mA
mA
outp. 1
outp. 2
4/
4/
20mA
20mA
Integr
ation
time s
0
TAG 1
to Default
Reset
OK ?
Reset
Now !
OK ?
Volt
outp. 1
0/10V
Reset
TAG1
Delete
TAG 1?
Volt
outp. 2
0/10V
Reset
OK?
Reset
Now!
OK?
Relay
output 1
Mode
Overfill
protec
Menu
mode
Reduced
Relay
output 2
like Rel.-outp.1
Low
%
0,0
High
%
100,0
Simulation
Simulation
Now
OK ?
Simulation
%
xx,x
with
medium
Min
adjust
at %
0,0
0%
corres
ponds
0
Max
adjust
at %
100,0
100%
corres
ponds
1000
Decimalpoint
888,8
w.out
medium
adjust
ment
bar
Prop.
to
undefined
0%
at
bar
0,000
Unit
– –
100%
at
bar
5,000
VEGAMET 514V 3
TAG No. 1
%
xx,x
Param.
TAGNo. 1
Adjust
ment
TAG No. 2
°C
xx,x
Param.
TAGNo. 2
like TAG-No.1
Signal
condit
ioning
TAG1-2
xx,x
xx,x
Outputs
mA
outputs
Measured value
indication
Volt.
outputs
Extended menu
MET-
Relay
Dis-
out-
play
puts
with
medium
Min
adjust
at %
0,0
Scaling
0%
corres
ponds
0
Max
adjust
at %
100,0
mA
output
no.1
Prop.
to
Percent
LINcurve
linear
100%
corres
ponds
1000
Volt.
output
no.1
mA
output
no.2
w.out
medium
Volt.
output
no.2
Unit
Prop.
to
Percent
0,0%
like mA-output no.1
Unit
mA
output
0,0%
4/
20mA
Densi-
Integr
ty in
ation
Kg/dm3
time s
1,000
0
Prop.
Deci-
to
mal-
unde-
point
fined
888,8
adjust
Offset
ment
correc
tion
bar
Sensor
unpres
sur’d
OK ?
Offset
corr.
Now !
OK ?
like Volt-output no.1
Volt.
Volts
output
at
0%
0/10V
0,000
mA
at
0%
4,000
Unit
– –
0%
at
bar
0,000
mA
at
100%
20,000
100%
at
bar
1,000
Volts
at
100%
10,000
Meas.
value
limita
tion
negative
Values
yes
Failure
mode
0mA
Failure
mode
0V
Fail.
mode
Standard
mA
limita
tion
on
Voltlimita
tion
on
Relay
output 1
Prop.
to
Percent
Prop.
to
Percent
Relay
output 2
like Relay
output 1
Unit
0,0%
Unit
0,0%
Mode
Overfill
protec
4 VEGAMET 514V