VEGA LOG571acc User Manual

Supplementary instruction
in
out
Connection VEGALOG 571 acc. to GL approval
1 2 3
PC
4 5 6 7 8 9 10
on on on on
VEGALOG
VEGALOG VEGALOG VEGALOG
571 EA 571 EV 571 AR571 CPU
!!
Mounting split ferrite

1 Mounting split ferrite

When using a VEGALOG 571 with GL approval, additional split ferrites must be used to keep the EMC regulations. This concerns teh RS232 connection cable for the CPU and the Probus PA cable of the EP card. The ferrites are attached to each VEGALOG with GL approval and must be mounted by the operator.
RS232 connection CPU
1 Open the two rectangular split ferrites
2 Place the rst ferrite close to a plug around the
RS232 cable
3 Apply the second split ferrite subsequently to the rst
one
4 Plug the side with the two ferrites to the RS232 of the
VEGALOG CPU and the other side to the PC
1
VEGALOG 571 CPU
2
1 RS232 interface CPU 2 Split ferrite
2 Connection VEGALOG 571 acc. to GL approval -
30831-EN-050601
Mounting split ferrite
Probus PA connection EP card
1 Open the round split ferrite
2 Place the ferrite close to the EP card around the
Probus PA cable
1
VEGALOG 571 EP
2
1 Probus PA output EP card 2 Split ferrite
30831-EN-050601
Connection VEGALOG 571 acc. to GL approval - 3
VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com
www.vega.com
ISO 9001
All statements concerning scope of delivery, application,
practical use and operating conditions of the sensors and
processing systems correspond to the information avail-
able at the time of printing.
Technical data subject to alterations 30831-EN-050601