VEGA KON61 User Manual

Page 1
Ope
rating Instructions
VEGAKON 61
- Relay (DPDT)
Document ID:
32647
Cond
uctive
Page 2

Contents

1 About this document
2 For your safety
3 Product description
4 Mounting
5 Connecting to power supply
ts
1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Symbolism used . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . .
2.4 General safety instructions . . . . . . . . . . . . . . . . . . . .
2.5 Safety label on the instrument . . . . . . . . . . . . . . . . . .
2.6 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.7 Environmental instructions. . . . . . . . . . . . . . . . . . . . .
3.1 Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4 Storage and transport . . . . . . . . . . . . . . . . . . . . . . .
4.1 General instructions . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Mounting instructions . . . . . . . . . . . . . . . . . . . . . . . .
5.1 Preparing the connection . . . . . . . . . . . . . . . . . . . . .
5.2 Connection instructions . . . . . . . . . . . . . . . . . . . . . . .
5.3 Connection, relay module . . . . . . . . . . . . . . . . . . . . .
3 3 3
4 4 4 4 5 5 5
6 6 7 8
9 9
11 11 12
6 Set up
6.1 General information . . . . . . . . . . . . . . . . . . . . . . . . .
6.2 Adjustment elements . . . . . . . . . . . . . . . . . . . . . . . .
6.3 Functional chart . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Maintenance and fault rectication
7.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Electronics exchange . . . . . . . . . . . . . . . . . . . . . . . .
7.3 Instrument repair . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Dismounting
8.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 Supplement
9.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.3 Industrial property rights . . . . . . . . . . . . . . . . . . . . . .
9.4 Trademark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 VE
14 14 14
16 16 17
18 18
32647-EN-100219
19 22 23 23
GAKON 61 • - Relay (DPDT)
Page 3
out this document
1 Ab
1 Abou
t this document

1.1 Function

This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.

1.2 Target group

This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Inform
ation, tip, note
This symbol indicates helpful additional information.
Cauti
on: If this warning is ignored, faults or malfunctions can
result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
applications
Ex
This symbol indicates special instructions for Ex applications.
32647-EN-100219
VEGAKON 61
l List
The dot set in front indicates a list with no implied sequence.
à Action
Th
is arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
- Relay (DPDT) 3
Page 4
2 For
your safety
or your safety
2 F

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.
During work on and with the device the required personal protective equipment must always be worn.

2.2 Appropriate use

The VEGAKON 61 is a sensor for level detection.
You can nd detailed information on the application range in chapter
"Product description".
Operational reliability is ensured only if the instrument is properly used according to the specications in the operating instructions manual as well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modications are explicitly forbidden.

2.3 Warning about misuse

Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overll or damage to system components through incorrect mounting or adjustment.

2.4 General safety instructions

This is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The user must take note of the safety instructions in this operating instructions manual, the country­specic installation standards as well as all prevailing safety regulations and accident prevention rules.
The instrument must only be operated in a technically awless and reliable condition. The operator is responsible for trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the compliance of the required occupational safety measures with the current valid rules and regulations and also take note of new regulations.
4 VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Page 5
2 For
your safety
2.5 Safety
The safety approval markings and safety tips on the device must be observed.
label on the instrument

2.6 CE conformity

This device fullls the legal requirements of the applicable EC guidelines. By attaching the CE mark, VEGA provides a conrmation of successful testing. You can nd the CE conformity declaration in the download area of
2.7 Envi
Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection.
The environment management system is certied according to DIN EN ISO 14001.
Please help us full this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage" l Chapter "Disposal"
www.vega.com.
ronmental instructions
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 5
Page 6
1
2
3
3 Produc
t description
Scope of delivery
Constituents
Type label
3 Produc
t description
3.1 Conguration
The scope of delivery encompasses:
l VEGAKON 61 compact level switch l Documentation
- this operating instructions manual
The VEGAKON 61 consist of the following components:
l Housing cover l Housing with electronics l Process tting
Fig. 1: VEGAKON 61
1 Housing 2 Housing with electronics 3 Process tting
cover
The type label contains the most important data for identication and use of the instrument:
l Article number l Serial number l Technical data l Article numbers, documentation
With the serial number, you can access the delivery data of the instrument via
www.vega.com, "VEG
A Tools" and "serial number
search". In addition to the type label outside, you can also nd the
serial number on the inside of the instrument.

3.2 Principle of operation

32647-EN-100219
Application area
6 VE
The conductive VEGAKON 61 compact level switches detect levels of
conductive liquids.
GAKON 61 • - Relay (DPDT)
Page 7
2
4
3
1
Functional principle
3 Produc
the annular electrode is covered with a conductive medium,
When
t description
small alternating currents (<1 mA) ow from the measuring electrode to the reference and neutralisation electrode.
Voltage supply
Fig. 2: Annular
1 Reference electrode (mounting boss) 2 Neutralisation electrode 3 Probe 4 insulation
electrode
These alternating currents are measured in respect to their amplitude and phase position and converted into a switching command.
Interfering buildup is automatically eliminated via the neutralisation electrode, the conductivity detected and the switching point sensitivity derived thereof. An adjustment of the instrument is not necessary.
VEGAKON 61 can be used for reliable detection of products over a very wide conductivity and viscosity range.
VEGAKON 61 is a compact instrument, i.e. it can be operated without external evaluation system. The integrated electronics evaluates the level signal and outputs a switching signal. With this switching signal, a connected device can be operated directly (e.g. a warning system, a
PLC, a pump etc.).
The data for power supply are specied in chapter "Technical data".

3.3 Operation

The VEGAKON 61 is a compact level switch with integrated electronics module.
On the electronics module you will nd the following indicating and adjustment elements:
l Control lamp for indication of the switching status l Mode changeover for selection of the output signal
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 7
Page 8
3 Produc
t description
Packaging
Transport
Transport inspection
Storage

Storage and transport

temperature
3.4 Stora
ge and transport
Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environment­friendly, recyclable cardboard. In addition, the sensor is provided with a protective cover of paperboard. For special versions PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device.
The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside.
Unless otherwise indicated, the packages must be stored only under the following conditions:
l Not in the open l Dry and dust free l Not exposed to corrosive media l Protected against solar radiation l Avoiding mechanical shock and vibration
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
l Relative humidity 20 85 %
8 VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Page 9
4 M
ounting
Suitability for the pro­cess conditions
Moisture
4 Moun
ting

4.1 General instructions

Make sure that all parts of the instrument exposed to the process, in particular the sensor element, process seal and process tting, are suitable for the existing process conditions. These include above all the process pressure, process temperature as well as the chemical properties of the medium.
You can nd the specications in chapter "Technical data" or on the type label.
Use the recommended cables (see chapter "Connecting to power supply") and tighten the cable gland.
You can give your VEGAKON 61 additional protection against moisture penetration by leading the connection cable downward in front of the cable entry. For this reason, the housing can be turned without any tools by 270°. Rain and condensation water can thus drain off. This applies mainly to outdoor mounting as well as installation in areas where high humidity is expected (e.g. through cleaning processes) or on cooled or heated vessels.
Pressure/Vacuum
Welded socket
32647-EN-100219
VEGAKON 61
Fig. 3: Measures
The process tting must be sealed if there is gauge or low pressure in the vessel. Before use, check if the seal material is resistant against the measured product and the process temperature.
The max. permissible pressure is specied in chapter "Technical data" or on the type label of the sensor.
against moisture penetration

4.2 Mounting instructions

Remove the supplied seal from the thread of VEGAKON 61. This seal is not required when using the welded socket with O-ring in front.
- Relay (DPDT) 9
Page 10
4 M
ounting
re welding, unscrew VEGAKON 61 and remove the rubber ring
Befo from the welded socket.
10 VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Page 11
ecting to power supply
5 Conn
Note safety instructions
Voltage supply
Connection cable
5 Conn
ecting to power supply

5.1 Preparing the connection

Always keep in mind the following safety instructions:
l Connect only in the complete absence of line voltage
Connect the operating voltage according to the following connection diagrams. The electronics module KONE60R is designed in protection class 1. To maintain this protection class, it is absolutely necessary that the ground conductor be connected to the internal ground terminal. Take note of the general installation regulations.
The data for power supply are specied in chapter "Technical data".
The instrument is connected with standard two-wire cable without
screen. If electromagnetic interference is expected which is above the test values of EN 61326 for industrial areas, screened cable should be used.
Use cable with round cross-section. A cable outer diameter of 5 … 9 mm (0.2 0.35 in) ensures the seal eect of the cable gland. If you are
using cable with a dierent diameter or cross-section, exchange the seal or use a suitable cable gland.

5.2 Connection instructions

r:
Dange
Switch opower supply before starting connection work.
32647-EN-100219
VEGAKON 61
Connect mains voltage according to the connection diagrams.
- Relay (DPDT) 11
Page 12
1
2
3
4
5
6
10
9
8
7
ecting to power supply
5 Conn
Floating relay output
1 Housing 2 Signal lamp (LED) 3 Connection terminals 4 Mode switch (A/B) 5 Type plate VEGAKON 61 6 Instrument housing 7 Electrode 8 Cable gland 9 Electronics module 10 Type plate of the electronics module
cover

5.3 Connection, relay module

Is used to switch external voltage sources to relays, contactors, magnetic valves, horns etc.
32647-EN-100219
12 VE
GAKON 61 • - Relay (DPDT)
Page 13
1
2
3 4
5
6
+
L1
-
N
1
2
ecting to power supply
5 Conn
Fig. 5: Electronics
1 Relay output 2 Voltage supply
with relay output
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 13
Page 14
1 2 3
4
6 Set
up
Function/Conguration
Mode adjustment (4)
6 Set
up

6.1 General information

On the electronics module you will nd the following indicating and adjustment elements:
l DIL switch for mode adjustment l Control lamp for indication of the switching status

6.2 Adjustment elements

1 Type 2 Signal lamp (LED) 3 Connection terminals 4 Mode switch (A/B)
With the mode adjustment (A/B) you can change the switching condition of the output. You can set the required mode according to the "Function chart" (A - max. detection or overow protection, B - min. detection or dry run protection).
label
Signal lamp (2)
The switching condition of the signal lamp can be checked when the housing is closed. To adjust VEGAKON 61 loosen the four screws with a wrench on the upper side of the instrument and remove the housing cover.

6.3 Functional chart

The following chart provides an overview of the switching conditions depending on the adjusted mode and level.
14 VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Page 15
Mode A
1
64 5
2
64 5
3
64 5
4
64 5
64 5
Overow protec­tion
Level Switching
relay module
E60R
status,
6 Set
Control lamp
up
Mode A Overow
protec-
tion
Mode B Dry
run protection
Mode B Dry
run protection
Failure
of the sup-
ply voltage (mode A/B)
1 Max. detection - Vessel 2 Max. detection - Vessel full 3 Min. detection - Vessel full 4 Min. detection - Vessel empty
empty
Relay
Relay
Relay
Relay
Relay
energized
deenergized
energized
deenergized
deenergized
does not light
lights
does not light
lights
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 15
Page 16
aintenance and fault rectication
7 M
7 Maint
enance and fault rectication

7.1 Maintenance

When used as directed in normal operation, VEGAKON 61 is completely maintenance free.

7.2 Electronics exchange

In general, all electronics modules of series KONE60 can be interchanged. If you want to use an electronics module with a dierent signal output, you can download the corresponding operating instructions manual from our homepage under Downloads.
Proceed as follows:
1 Switch opower supply 2 Unscrew the housing cover 3 Loosen compression ttings with a screwdriver 4 Pull the connection cables out of the terminals 5 Loosen the two screws with a screw driver (Phillips recessed
head)
6 Pull out the old electronics module 7 Compare the new electronics module with the old one. The type
label of the el ectronics module must correspond to that of the old electronics module.
8 Note settings of all adjustment elements of the old electronics
module.
Set the adjustment elements of the new electronics module to the same settings of the old one.
9 Screw in and tighten the two holding screws with a screwdriver
(Phillips)
10 Insert the wire ends into the open terminals according to the wiring
plan
11 Tighten the screw terminals 12 Check the hold of the wires in the terminals by lightly pulling on
them
13 Check cable gland on tightness. The seal ring must completely
encircle the cable.
14 Screw the housing cover on
The electronics exchange is now nished.
As soon as you insert the electronics module, VEGAKON 61 is ready
for operation.
16 VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Page 17
aintenance and fault rectication
7 M
7.3 Instru
If a repair is necessary, please proceed as follows:
You can download a return form (23 KB) from our Internet homepage
www.vega.com under: "Downloads - Forms and certicates - Repair form".
By doing this you help us carry out the repair quickly and without having to call back for needed information.
l Print and ll out one form per instrument l Clean the instrument and pack it damage-proof
l Attach the completed form and, if need be, also a safety data
sheet outside on the packaging
l Please ask the agency serving you for the address of your return
shipment. You can nd the respective agency on our website www.vega.com
ment repair
under: "Company - VEGA worldwide"
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 17
Page 18
8 Dismoun
ting
8 Dismou
nting

8.1 Dismounting steps

Warning:
Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vessel, high temperatures, corrosive or toxic products etc.
Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order.

8.2 Disposal

The instrument consists of materials which can be recycled by specialised recycling companies. We use recyclable materials and have designed the electronics to be easily separable.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive 2002/96/EG and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. These may be used only for privately used products according to the WEEE directive.
Correct disposal avoids negative eects to persons and environment and ensures recycling of useful raw materials.
Materials: see chapter "Technical data"
If you have no possibility to dispose of the old instrument
professionally, please contact us concerning return and disposal.
18 VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Page 19
9 Sup
plement
9 Supp
lement

9.1 Technical data

General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
- Process tting - thread 316Ti
- Process tting - Cone 316Ti
- Electrode 316Ti
- Insulation ring PTFE
- Process seal Klingersil C-4400
Materials, non-wetted parts
- Housing plastic PBT (Polyester)
- Temperature adapter 316Ti
- Seal between housing and housing
cover
- Ground terminal 316L
Weights
- with plastic housing 600 g (21 oz)
- Temperature adapter 150 g (5.3 oz)
Process ttings
- Thread (DIN 3852-A) G1 A (PN 25)
- Cone Cone DN 25 (PN 25)
- Tuchenhagen
Measurement voltage approx. 1 V Measurement current < 1 mA
Silicone
, 5 kHz
ss
Output variable
Output Relay output (DPDT), 1 oating spdt
Turn-on voltage
- min. 10 mV
- max. 253 V AC, 253 V DC
Switching current
- min. 10 µA
- max. 3 A AC, 1 A DC
Breaking capacity
- min. 50 mW
- max. 750 VA AC, 54 W DC
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 19
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
Page 20
1
2
110°C
(230°F)
120°C
(248°F)
100°C
(212°F)
130°C
(266°F)
140°C
(284°F)
150°C
(302°F)
50°C
(122°F)
60°C
(140°F)
70°C
(158°F)
9 Suppl
ement
surface will be permanently damaged. T is then no longer suitable for switching low-level signal circuits.
Contact material (relay contacts) AgNi or AgSnO and Au plated
Modes (adjustable)
- A Max. detection or overow protection
- B Min. detection or dry run protection
Switching delay
- When immersed 0.5 s
- When laid bare 0.5 s
Ambient conditions
Ambient temperature on the housing -40 +70 °C (-40 +158 °F)
Ambient temperature with operating voltage
-40 … +50 °C (-40 … +122 °F)
> 60 V DC Storage and transport temperature -40 +80 °C (-40 +176 °F)
Process conditions
Permissible process temperature
- Without temperature adapter -40 +100 °C (-40 +212 °F)
- with temperature adapter -40 +150 °C (-40 +302 °F)
he contact
Fig. 21: Ambient
temperature - Process temperature
1 Process temperature in °C 2 Ambient temperature in °C
Process pr essure -1 25 bar/-100 2500 kPa (-14.5 362 psig) Conductive of the medium min. 7.5 µS/cm
20 VE
GAKON 61 • - Relay (DPDT)
32647-EN-100219
Page 21
1
2
0°C
(32°F)
0bar
(0 psi)
50°C
(122°F)
10bar
(50psi)
20bar
(290psi)
25bar
(363psi)
-40°C
(-40°F)
100°C
(212°F)
150°C
(302°F)
9 Sup
plement
Fig. 22: Process
temperature - Process pressure
1 Process temperature in °C 2 Process pressure in bar
Electromechanical data
Cable gland
- with relay module 1 x cable entry M20 x 1.5; 1 x blind stopper M20 x 1.5 (cable gland M20 x 1.5 is attached)
Screw terminals for wire cross-section up to 1.5 mm² (AWG 16)
Voltage supply
Operating voltage 20 … 253 V AC, 50/60 Hz, 20 72 V DC (at
U > 60 V DC, the ambient temperature can be max. 50 °C/122 °F)
Power consumption 1 … 8 VA (AC), approximately 1.3 W (DC)
Electrical protective measures
Protection rating IP 66
Overvoltage category III
Protection class I
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 21
Page 22
80mm x 110mm
(3 5/32" x 4 21/64")
~30mm (1 3/16")
75mm (2
61
/
64
")
51mm
(2
1
/
64
")
52mm
(2
3
/
64
")
10mm
(
25
/
64
")
21mm
(
53
/
64
")
28mm
(
17
/
64
")
G1A
SW 41mm
(1 39/64")
1 2
3
M20x1,5
9 Suppl
9.2 D
ement
imensions
Fig. 23: VEGAKON 61
1 Threaded 2 Cone version 3 Temperature adapter
version
22 VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Page 23
9 Sup
plement
9.3 Indus
VEGA product lines are global protected by industrial property rights. Further information see http://www.vega.com. Only in U.S.A.: Further information see patent label at the sensor
housing.
VEGA Produktfamilien sind weltweit geschützt durch gewerbliche Schutzrechte.
Nähere Informationen unter http://www.vega.com.
Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellectuelle.
Pour plus d'informations, on pourra se référer au site http://www.vega.
com.
VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad industrial.
Para mayor información revise la pagina web http://www.vega.com.
Линии продукции фирмы ВЕГА защищаются по всему миру правами на интеллектуальную собственность.
Дальнейшую информацию смотрите на сайте http://www.vega.com.
VEGA 站<http://www.vega.com>
trial property rights

9.4 Trademark

All the brands as well as trade and company names used are property of their lawful proprietor/originator.
32647-EN-100219
VEGAKON 61
- Relay (DPDT) 23
Page 24
VEGA Grieshaber KG
ISO 9001
Am Hohenstein 113 77761 Schiltach
Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com
www.vega.com
Printing date:
statements concerning scope of delivery, application,
All
practical use and operating conditions of the sensors and
processing systems correspond to the information avail-
able at the time of printing.
© VEGA Grieshaber KG, Schiltach/Germany 2010