This operating instructions manual provides all the information you
need for mounting, connection and setup as well as important
instructions for maintenance and fault rectification. Please read this
information before putting the instrument into operation and keep this
manual accessible in the immediate vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained qualified
personnel. The contents of this manual should be made available to
these personnel and put into practice by them.
1.3 Symbolism used
Inform
ation, tip, note
This symbol indicates helpful additional information.
Cauti
on: If this warning is ignored, faults or malfunctions can
result.
Warning: If this warning is ignored, injury to persons and/or serious
damage to the instrument can result.
Danger: If this warning is ignored, serious injury to persons and/or
destruction of the instrument can result.
applications
Ex
This symbol indicates special instructions for Ex applications.
32647-EN-100219
VEGAKON 61 •
lList
The dot set in front indicates a list with no implied sequence.
àAction
Th
is arrow indicates a single action.
1Sequence
Numbers set in front indicate successive steps in a procedure.
- Relay (DPDT)3
2 For
your safety
or your safety
2 F
2.1 Authorised personnel
All operations described in this operating instructions manual must be
carried out only by trained specialist personnel authorised by the plant
operator.
During work on and with the device the required personal protective
equipment must always be worn.
2.2 Appropriate use
The VEGAKON 61 is a sensor for level detection.
You can find detailed information on the application range in chapter
"Product description".
Operational reliability is ensured only if the instrument is properly used
according to the specifications in the operating instructions manual as
well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbitrary
conversions or modifications are explicitly forbidden.
2.3 Warning about misuse
Inappropriate or incorrect use of the instrument can give rise to
application-specific hazards, e.g. vessel overfill or damage to system
components through incorrect mounting or adjustment.
2.4 General safety instructions
This is a high-tech instrument requiring the strict observance of
standard regulations and guidelines. The user must take note of the
safety instructions in this operating instructions manual, the countryspecific installation standards as well as all prevailing safety
regulations and accident prevention rules.
The instrument must only be operated in a technically flawless and
reliable condition. The operator is responsible for trouble-free
operation of the instrument.
During the entire duration of use, the user is obliged to determine the
compliance of the required occupational safety measures with the
current valid rules and regulations and also take note of new
regulations.
4VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
2 For
your safety
2.5 Safety
The safety approval markings and safety tips on the device must be
observed.
label on the instrument
2.6 CE conformity
This device fulfills the legal requirements of the applicable EC
guidelines. By attaching the CE mark, VEGA provides a confirmation
of successful testing. You can find the CE conformity declaration in the
download area of
2.7 Envi
Protection of the environment is one of our most important duties. That
is why we have introduced an environment management system with
the goal of continuously improving company environmental protection.
The environment management system is certified according to DIN
EN ISO 14001.
Please help us fulfil this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage"
l Chapter "Disposal"
www.vega.com.
ronmental instructions
32647-EN-100219
VEGAKON 61 •
- Relay (DPDT)5
1
2
3
3 Produc
t description
Scope of delivery
Constituents
Type label
3 Produc
t description
3.1 Configuration
The scope of delivery encompasses:
l VEGAKON 61 compact level switch
l Documentation
- this operating instructions manual
The VEGAKON 61 consist of the following components:
l Housing cover
l Housing with electronics
l Process fitting
Fig. 1: VEGAKON 61
1Housing
2Housing with electronics
3Process fitting
cover
The type label contains the most important data for identification and
use of the instrument:
l Article number
l Serial number
l Technical data
l Article numbers, documentation
With the serial number, you can access the delivery data of the
instrument via
www.vega.com, "VEG
A Tools" and "serial number
search". In addition to the type label outside, you can also find the
serial number on the inside of the instrument.
3.2 Principle of operation
32647-EN-100219
Application area
6VE
The conductive VEGAKON 61 compact level switches detect levels of
conductive liquids.
GAKON 61 • - Relay (DPDT)
2
4
3
1
Functional principle
3 Produc
the annular electrode is covered with a conductive medium,
When
t description
small alternating currents (<1 mA) flow from the measuring electrode
to the reference and neutralisation electrode.
These alternating currents are measured in respect to their amplitude
and phase position and converted into a switching command.
Interfering buildup is automatically eliminated via the neutralisation
electrode, the conductivity detected and the switching point sensitivity
derived thereof. An adjustment of the instrument is not necessary.
VEGAKON 61 can be used for reliable detection of products over a
very wide conductivity and viscosity range.
VEGAKON 61 is a compact instrument, i.e. it can be operated without
external evaluation system. The integrated electronics evaluates the
level signal and outputs a switching signal. With this switching signal, a
connected device can be operated directly (e.g. a warning system, a
PLC, a pump etc.).
The data for power supply are specified in chapter "Technical data".
3.3 Operation
The VEGAKON 61 is a compact level switch with integrated
electronics module.
On the electronics module you will find the following indicating and
adjustment elements:
l Control lamp for indication of the switching status
l Mode changeover for selection of the output signal
32647-EN-100219
VEGAKON 61 •
- Relay (DPDT)7
3 Produc
t description
Packaging
Transport
Transport inspection
Storage
Storage and transport
temperature
3.4 Stora
ge and transport
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
according to DIN EN 24180.
The packaging of standard instruments consists of environmentfriendly, recyclable cardboard. In addition, the sensor is provided with
a protective cover of paperboard. For special versions PE foam or PE
foil is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out under consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or
concealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
l Not in the open
l Dry and dust free
l Not exposed to corrosive media
l Protected against solar radiation
l Avoiding mechanical shock and vibration
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
l Relative humidity 20 … 85 %
8VE
32647-EN-100219
GAKON 61 • - Relay (DPDT)
Loading...