Vaisala WHP25 QUICK REFERENCE GUIDE

Quick Reference Guide
WHP25 Power Supply
DESCRIPTION
The WHP25 is a compact size Mains Power Supply Unit intended for outdoor use.
The nominal input power of 230 VAC can be changed by jumpers between 100 VAC to 245 VAC (±10 %). There are two power outputs, namely 24.0 VDC (max 5.2 A) and 38.0 VAC (max 0.9 A).
The WHP25 Outdoor Power Supply is capable of delivering power to the whole WA25 Heated Wind Sensor System and additionally, for example, to the RG13H Heated Rain Gauge.
The WHP25 has a water-proof housing made from cast aluminium, mountable to a Ø 100 mm standard pole mast with a mounting hardware included in the delivery. The unit can also be mounted to the standard DKP11 Stacked Mast using the 10388DK mounting kit.
INSTALLATION
Figure 1 illustrates mounting of the WHP25 to a Ø 100 mm pole mast, with the standard mounting clamp. For installation, follow the procedure below:
1 Remove the four screws attaching the cover of the WHP25 unit. Remove the cover.
2 Attach the unit to the mast at suitable height with the two M6 screws and the mounting clamp.
3 With the local mains voltage level other than 230 VAC, make proper reselection with the jumpers at X2 and X3 (under the protective cover). Observe the instructions and warnings in the instruction label inside the unit. Refer to Figure 2.
4 With the mains voltage disconnected enter the mains cable through the leftmost cable gland and do the input wiring to the X1 (spring loaded terminals) and Earth (crimp & screw). Tighten the input cable gland.
5 Enter the output power cable(s) through the rightmost cable gland(s). For better protection against RF interference, follow the earthing instructions of the cable shield in Fig. 4. Assure that no shield mesh gets on the circuit board.
6 Do the output wiring to the X4 removable screw terminal block (refer to the instruction label). Tighten the output cable gland(s).
7 Carefully reattach the enclosure cover with the four screws.
 Linear 160 W Mains Power Supply
 Compact size with mast mounting
 Outdoor use with IP65 (Nema 4) housing
Slot screw M6x40 DIN 84 A4 2 pcs
Washer A6,4 Spring washer B6 Nut M6 DIN 934
Figure 1. WHP25 mounting
-1
9
9
ø
5
0
DIN 125 A4 DIN 127 A4 DIN 934 A4
X1
ELN
MAINS INPUT
1.0 - 2.0 A
2AT
F1
Primary
MAINS VOLTAGE SELECTION
100V 115V 200V 215V 230V 245V
X2
X3
WARNING! Improper jumper setting
FUSES
may cause damage.
Secondary
Factory setting
8AT
(X2, X3)
F2
X4
38VAC
ACout
(RG13H)
NOTE! Total wire resistance
less than 0.3 ohms recommended for WA25 systems.
1
0.9A
3
2
456
24VDC
5.2A
DCout
(WA25)
Figure 2. WHP25 wiring instructions (refer also to label inside the enclosure)
8
7
TECHNICAL DATA
WHP25
WAV15A
WAA25
MILOS 500 or other AWS
WAC151
Input operating power
Nominal 230 VAC ±10 %, 50/60 Hz, 1.0 A max. Optional selections 100/115/200/215/245 VAC (±10 %)
Output power
DC output 24.0 ±2.5 VDC, 5.2 A (max.)
AC output 38.0 ±3.0 VAC, 0.9 A (max.)
Fuses
Primary 2 AT replaceable fuse, 5 × 20 mm (F1) 24 V output 8 AT replaceable fuse, 5 × 20 mm (F2) 38 V output 1.8 Amp solid state fuse (R3)
Electrical connections
Cable glands (3) One for input, two for outputs
Input wiring (L, N) Spring loaded terminals (X1)
Input wiring (E) Crimp connector, 2.5 mm2 max. Output wiring (24 V, 38 V) 8-pin removable screw terminal
1.5 mm2 max. wire dimension
connector, 2.5 mm2 max. Operating temperature  60 ... +55 °C Storage temperature  60 ... +70 °C Humidity Non-condensing Material
Housing Cast aluminium, painted grey
Mounting clamp AlMgSi, grey anodized Ingress protection IP65 (Nema 4) Dimensions
Unit 220 × 120 × 81 mm (w × h × d)
(cable glands add 23 mm to height)
Mounting To a Ø 99  105 mm pole mast tube
with standard mounting clamp
Weight 3.6 kg
(X4/4, 5  6, 7)
(X4/1  2)
Cable Ø 7  10 mm
81
Mounting holes (4 pcs) at the bottom of the enclosure
82
120
143
Mains Input Cable
Figure 3. WHP25 dimensions
220 204
MAINS POWER SUPPLY
Power Output Cable
ISO 9001
CERTIFIED QUALITY SYSTEM
Head Office: VAISALA Oy PL 26, FIN-00421 Helsinki FINLAND Phone (int.): (+358 0) 894 91 Telefax: (+358 0) 894 9227 Telex: 122832 vsala fi
Enter the shield through the two washers and squeeze part of it evenly between those.
CAUTION: The shield mesh must not touch the circuit board or its components. Make sure no pieces of mesh or other metal parts get to the board.
Figure 4. Earthing of power output cable shield
Ref. WHP25-U146en-1.1
Figure 5. Typical installation with a Heated Wind Sensor System