www.vaisala.com
GMW115 Carbon Dioxide Transmitter for
Demand-controlled Ventilation
from the stable reference provided by
the electrically tunable Fabry-Perot
Interferometer (FPI).
The tunable FPI lter measures CO
absorption, and simultaneously a
reference wavelength. This internal
reference measurement compensates
effectively for any changes in the
The Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW115 is a wall-mounted
CO
transmitter for demand-controlled ventilation.
2
Features/Benefits
Compact, wall-mounted
▪
transmitter for demandcontrolled ventilation
Incorporates Vaisala
▪
CARBOCAP®, the silicon based
NDIR sensor with unique
internal referencing
Advanced, single-beam, dual
▪
wavelength measurement with
no moving parts
Excellent long-term stability
▪
Ideal for ventilation control in
▪
all types of occupied spaces
Most of us spend 90 % of our time
indoors. Consequently, good indoor
air quality is important to our
wellbeing. All human beings produce
carbon dioxide gas by respiration,
thus the carbon dioxide level can
be used as an indicator for indoor
human presence. A high CO
sign of poor ventilation and often an
indication of other unpleasant odors
in the air. In many buildings the
ventilation need varies throughout
the day. Demand controlled
ventilation is an economical way to
ensure good air quality.
The Vaisala CARBOCAP
sensors have been proven to be
accurate and durable. They have
an excellent long-term stability,
which decreases maintenance. The
superior performance of Vaisala
CARBOCAP
®
sensors results largely
®
CO2
level is a
2
optical path, such as light source
intensity changes and contamination.
In the HVAC market, this type of
reference measurement is a unique
feature to Vaisala CARBOCAP
products, distinguishing them
from competitors’ comparative
products that do not have a reference
measurement at all, or have an
indirect reference measurement,
which is based on an assumed background CO
around-the-clock occupancy (e.g.
hospitals, work-places, residential
buildings, retirement homes), the
assumed background CO
reference is simply not applicable.
The true internal reference
measurement of Vaisala CARBOCAP
CO
transmitters provides years of
2
stable CO
The GMW115 Transmitter is designed
especially for DCV (Demand Controlled
Ventilation) applications with two
optional CO
0…2000 ppm and 0…5000 ppm.
levels. In buildings with
2
measurements.
2
measurement ranges of
2
level
2
2
®
®
66.3
60
60
Ø 4.2
66.7
85.3
83.4
85.2
R2.1
124
120.9
25.8
84
R3.5
Technical data
Performance
CO2-measurement range 0 ... 2000 ppm
0.....5000 ppm
Accuracy (including repeatability, nonlinearity and calibration uncertainty)
±(2 % of range + 2 % of
reading)
Long-term stability ± 5 % of range/5 years
Response time T90 1 min
Temperature dependence, typical -0,35 % of reading / °C
Pressure dependence, typical +0,15 % of reading/hPa
Warm-up time 1 min, 10 min for full.
specification
Product lifetime > 10 years
Operating environment
Temperature -5 ... +45 °C (23 ... 113 °F)
Humidity 0 ... 85 % RH
Pressure 700 ... 1200 hPa
Electromagnectic compatibility
Complies with EMS standard EN61326-1, Generic Environment
Inputs and outputs
Operating voltage 24 V (±20 %) AC/DC
Power consumption <2 W
Outputs 4 … 20 mA, 0 … 10 V,
RS-485, 2-wire, non-isolated
Dimensions
Dimensions in mm
Housing
Material: ABS plastics
Colour: Cycolac 233599/NCS 0502-G50Y
Fire resistance: UL94 HB
Ingress protection: IP30
For more information, visit
www.vaisala.com or contact
us at sales@vaisala.com
Ref. B210568EN-D ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.