UVP EpiChemi II Darkroom User Manual

EpiChemiII Darkroom
Set-Up & Operating Instructions
IMPORTANT:
Please read these instructions before setting up and operating your
EpiChemi II Darkroom to familiarize yourself with operation procedures.
81-0202-01
Table of Contents
Introduction ...................................................................................... 1
Components ................................................................................... 2
Set-Up and Operating Instructions................................................... 3
Troubleshooting .............................................................................. 5
Replacement Parts ......................................................................... 5
Technical Assistance ...................................................................... 6
Wiring Diagram .............................................................................. 7
Introduction
The EpiChemi II (EC2) Darkroom is designed specifically for low light and fluorescence im­aging and because of its light-tightness is particularly suitable for chemiluminescent applica­tions. The special design accommodates a Benchtop Transilluminator on the convenient sliding tray for easy access. For chemiluminescent applications, the chemi sample tray can be low­ered for sample positioning. Additionally, the darkroom provides users added flexibility due to the filter wheel and overhead UV.
UVP offers a large selection of cameras with specially designed mounts for securely con­necting the camera to the darkroom. Camera specifications are not discussed in this manual. Contact UVP or see other documentation included with your system for camera operating and set-up instructions. Transilluminators are ordered separately and also include their own documentation.
The EpiChemi II Darkroom features:
Overhead Light Selector: White Light 365nm UV 254nm UV
CCD Camera and Mounting Bracket
(Contact UVP or see other documentation for camera set-up instructions. The EpiChemi Darkroom may be sold with various camera options with appropriate mounting brackets.)
Filter Wheel Selector
Transilluminator Control
Master On/Off Switch
Gel Viewer
Compression Door Lock
Benchtop UV Transilluminator
Fold-Down Sample Platform for Chemi blots
Sliding Transilluminator Tray
1
Components
The EpiChemi II Darkroom is comprised of:
Darkroom Cabinet
The EpiChemi II Darkroom is manufactured of stainless steel construction and fabricated to provide a light-tight chamber. The darkroom is ready to go with connections to a wall outlet, the camera, mount and transilluminator.
Filter Wheel
The five-position filter wheel is designed for viewing many fluorescent and visible color stains. Rotate the dial to de­sired filter as required for you application. The filter wheel is securely mounted into the darkroom for a clean, protected environment.
Filter Wheel
EC2 Darkroom Filter Performance
Gel Viewer
The viewer opens for safe viewing of samples. The safety glass allows viewing without exposure to ultraviolet radia­tion.
Sample Platform
The sample platform folds down for placement of chemi blots.
2
Sample Platform and Transilluminator Tray
Transilluminator Tray
The slides forward and back for easy access to the transilluminator surface. See transillu­minator documentation for specific transilluminator operating instructions.
NOTE: When using the transilluminator with the darkroom door open, UV exposure safety precautions, including protective eyewear and clothing, must be observed to prevent harm­ful ultraviolet radiation exposure.
Set-Up and Operating Instructions
DO NOT ATTEMPT TO CONNECT ANY WIRING WHILE THE EQUIPMENT IS CONNECTED TO ANY POWER SUPPLY.
CAUTION!
Do not install the EpiChemi II Darkroom in places with high moisture, dust or high temperature.
Do not use any oil or petroleum based cleaner for the cabinet. Use only mild soap or detergent solution for cleaning. Ensure that the system is turned OFF during cleaning.
Set-Up
1. Connect the camera and mount to the darkroom as specified in the camera documentation manual.
2. Connect the power cord to the main power port which is located on the back-top of the darkroom cabinet.
Operation
1. Turn on the master power switch on the front of the darkroom cabinet. Once the power is switched on, power is applied to all internal components and to the power port for the jumper power cable that supplies power to the transilluminator.
2. The Transilluminator Control knob has three options:
Safety Switch - Transilluminator safety control switch automatically turns the transilluminator off when door opens which prevents the user from exposure to UV
Always Off - This button setting puts the transilluminator in Off mode. Use this switch when the transilluminator is not required such as when capturing chemi blots.
3
Always On - This setting overrides the safety switch with the transilluminator always in the on mode. Users should
wear protective clothing and eyewear when the darkroom is in the Always On mode to prevent exposure to the UV.
3. The Overhead Light control knob has four options for providing overhead diffused 254 and 365nm UV and fluorescent white light for uniform epi-illumination.
Off - Place the overhead light switch in the Off mode when not using the darkroom for applications requiring epi­illumination.
White - Overhead white light illuminates when white is selected.
365nm and 254nm - When either ultraviolet wavelength is selected, the red light will illuminate to alert the user that the light is in operation. The overhead lights are designed to automatically turn off when the darkroom door is open.
4. The Transilluminator Tray accommodates a Benchtop UV Transilluminator. The tray moves forward or back for easy access to the transilluminator surface.
NOTE: When using the transilluminator with the darkroom door open, UV exposure safety precautions, including pro­tective eyewear and clothing,
must be observed to prevent
harmful ultraviolet radiation exposure.
5. The Sample Platform folds backwards against the back of the darkroom cabinet. Pull the platform down into a horizontal position as shown in the picture. The sample platform is designed for use when transillumination is not required. The platform provides a surface for placement of chemiluminescent blots with minimum background noise interference.
6. The Gel Viewer has a pressure-sensitive clasp. Press firmly to open the viewer. The glass is UV blocking while providing a clear view to the transilluminator or platform surface for visibility of samples without opening the door.
4
Troubleshooting
No power to darkroom cabinet.
1. Recheck main power cord connections to the both the EC2 Darkroom and the wall
power (surge protector).
2. Check the fuse located on the main power port. If the darkroom continues to blow
fuses, call UVP Technical Support Department.
Transilluminator will not turn on!
1. Be sure the darkroom cabinets door is completely closed. There is a UV exposure
safety cut-off switch that turns the transilluminator of when the darkroom cabinets door is opened.
2. Be sure the darkroom cabinets main power switch is lit. If not, refer to No power to
darkroom cabinet above.
3. Be sure the transilluminator switch is on. When the switch on the transilluminator is lit
green, the unit is receiving power!
4. Be sure the transilluminator control switch on the darkrooms front panel is selected to
either safety switch or always on.
5. Call UVP Technical Support Department with any technical questions.
Replacement Parts
To order replacement parts for the EpiChemi II Darkroom, contact UVPs offices. Contact information is listed on the next page.
Part Description Part Number Qty.
Tube, 8 watt, fluorescent, cool white 34-0056-01 2 Tube, 8 watt, 365nm UV longwave 34-0006-01 2 Tube, 8 watt, 254nm UV germicidal 34-0007-01 2 Cable and connector wall plug, 115V and 100V 58-0085-01 1 Cable and connector wall plug, 230V 58-0085-03 1
5
Technical Assistance
UVP offers technical support for all of its products. If you have any questions about the products use, operation or repair, please call or fax UVP Customer Service or Technical Support at the following:
If you are located in North America, South If you are in Europe, Africa, the Middle East America, East Asia or Australia: or Western Asia:
Call (800) 452-6788 or (909) 946-3197 and Call +44(0) 1223-420022 and ask for BioImaging
ask for BioImaging Systems Technical Support. Systems Technical Support. Support is available Tech Support assistance is available during during regular business days, between 8:00am regular business days, between 7:00am and and 5:30 pm UK time. 5:30 pm PST.
E-Mail your message to: E-Mail your message to techsupport@uvp.com uvp@uvp.co.uk
Fax your questions to: Fax your questions to: (909) 946-3597 +44(0)1223-420561
Write to: Write to:
BioImaging Systems Technical Support BioImaging Systems Technical Support UVP, Inc. Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall Farm Estate, Nuffield Road Upland, CA 91786 USA Cambridge CB4 1TG UK
A Returned Goods Authorization (RGA) number must be obtained from UVPs Customer Service Department prior to returning any product to UVP.
6
Wiring Diagram
7
Products available from UVP
LabWorks Image Acquisition and Analysis Software
Ultraviolet Transilluminators
UV/White Light Transilluminators
Visi-Blue Transilluminators and Plates
White Light Transilluminators and Plates
Gel Tools
UV Crosslinkers
UV Viewing Cabinets
UV Lamps
Ultraviolet Intensity Meters
Hybridization Ovens
http://www.uvp.com
UVP, Inc., 2066 W. 11th Street, Upland, California 91786
(800) 452-6788  (909) 946-3197 Fax: (909) 946-3597  E-Mail: uvp@uvp.com
Ultra-Violet Products Limited, Unit 1, Trinity Hall Estate, Nuffield Rd. Cambridge, CB4 1TG UK
+44(0)1223-420022  Fax: +44(0)1223-420561 E-Mail: uvp@uvp.co.uk