Introduction
The EL Series Ultraviolet Lamps offer a uniform and intense source of ultraviolet light (radiation). The lamps emit one of three UV wavelengths or white light in four watt, six watt and eight watt configurations for exposure/illumination of materials. All EL Series Lamps can be used with the universal J138 Lamp Stand. The four watt models can be used with C-10E Cabinet for viewing materials in a darkroom environment. Eight watt lamps can be used with the C-65 Cabinet.
NOTE: Though the manual refers to the midrange UV waveband as 302nm, others refer to this region as 300nm or 312nm. The spectral output of all these regions is the same.
CAUTION: Shortwave and midrange UV radiation will cause damage to unprotected eyes and skin. Before operating any unit, be sure all personnel in the area are properly protected. UV Blocking Eyewear should be worn as well. UVP has a complete line of UV Blocking Eyewear: Spectacles, Goggles and Faceshield designed for this purpose.
8-Watt Model
Specifications
EL Lamps - Four Watt Models
Dimensions: 9.8”L x 2.5”H x 3.8”W (249 x 64 x 97 mm)
6-Watt Model
4-Watt Model
Model Part Number Volt/Hz/Amp Wavelength___________
UVS-14 95-0266-01 115/60/0.16 254nm/White (one tube each) 95-0266-02 230/50/0.16 95-0266-03 100/50-60/0.16
UVL-14 95-0264-01 115/60/0.16 365nm/White (one tube each) 95-0264-02 230/50/0.16
EL Series UV Lamps Page 3
95-0264-03 100/50-60/0.16 UVS-24 95-0269-01 115/60/0.32 254nm (two tubes)
95-0269-02 230/50/0.32 95-0269-03 100/50-60/0.32
UVL-24 95-0267-01 115/60/0.32 365nm (two tubes) 95-0267-02 230/50/0.32 95-0267-03 100/50-60/0.32
UVLS-24 95-0271-01 115/60/0.16 365/254nm (one tube each) 95-0271-02 230/50/0.16 95-0271-03 100/50-60/0.16
EL Lamps - Six Watt Models
Dimensions: 11.9”L x 2.5”H x 3.8”W (302 x 64 x 97 mm)
Model Part Number Volt/Hz/Amp Wavelength___________
UVS-16 95-0274-01 115/60/0.16 254nm/White (one tube each) 95-0274-02 230/50/0.16 95-0274-03 100/50-60/0.16
UVL-16 95-0272-01 115/60/0.16 365nm/White (one tube each) 95-0272-02 230/50/0.16 95-0272-03 100/50-60/0.16
UVM-16 95-0273-01 115/60/0.16 302nm/White (one tube each) 95-0273-02 230/50/0.16 95-0273-03 100/50-60/0.16
UVS-26 95-0277-01 115/60/0.32 254nm (two tubes) 95-0277-02 230/50/0.32 95-0277-03 100/50-60/0.32
UVL-26 95-0275-01 115/60/0.32 365nm (two tubes) 95-0275-02 230/50/0.32 95-0275-03 100/50-60/0.32
UVM-26 95-0276-01 115/60/0.16 302nm/White (two tubes) 95-0275-02 230/50/0.16 95-0275-03 100/50-60/0.16
UVLS-26 95-0279-01 115/60/0.16 365/254nm (one tube each) 95-0279-02 230/50/0.16 95-0279-03 100/50-60/0.16
UVLM-26 95-0278-01 115/60/0.16 365/302nm (one tube each) 95-0278-02 230/50/0.16 95-0278-03 100/50-60/0.16
EL Lamps - Eight Watt Models
Dimensions: 14.9”L x 2.5”H x 3.8”W (376 x 64 x 97 mm)
Model Part Number Volt/Hz/Amp Wavelength___________
UVS-18 95-0200-01 115/60/0.16 254nm/White (one tube each)
EL Series UV Lamps Page 4
95-0200-02 230/50/0.16 95-0200-03 100/50-60/0.16
UVL-18 95-0198-01 115/60/0.16 365nm/White (one tube each) 95-0198-02 230/50/0.16 95-0198-03 100/50-60/0.16
UVM-18 95-0199-01 115/60/0.16 302nm/White (one tube each) 95-0199-02 230/50/0.16 95-0199-03 100/50-60/0.16
UVS-28 95-0249-01 115/60/0.32 254nm (two tubes) 95-0249-02 230/50/0.32 95-0249-03 100/50-60/0.32
UVL-28 95-0248-01 115/60/0.32 365nm (two tubes) 95-0248-02 230/50/0.32 95-0248-03 100/50-60/0.32
UVM-28 95-0250-01 115/60/0.32 302nm (two tubes) 95-0250-02 230/50/0.32 95-0250-03 100/50-60/0.32
UVLS-28 95-0201-01 115/60/0.16 365/254nm (one tube each) 95-0201-02 230/50/0.16 95-0201-03 100/50-60/0.16
UVLM-28 95-0251-01 115/60/0.16 365/302nm (one tube each) 95-0251-02 230/50/0.16 95-0251-03 100/50-60/0.16
UVLMS-38 95-0252-01 115/60/0.16 365/302/254nm (one tube each) 95-0252-02 230/50/0.16 95-0252-03 100/50-60/0.16
Operation
Safety Precautions
Shortwave and midrange UV radiation will cause damage to unprotected eyes and skin. Before operating any unit, be sure all personnel in the area are properly protected. UV Blocking Eyewear should be worn as well.
Using the Lamp
Plug power cord into a properly grounded electrical outlet. The proper voltage of the lamp is found on the product information label.
The power switch is conveniently located on top of the unit to turn the lamp on or off. For models with multiple wavelengths the switch allows selection of wavelength or to shut
the unit off.
Each lamp comes with two UV tube or one UV and one white light tube. The UVLMS-38
is equipped with three tubes. Models with two tubes of the same wavelength operate with both tubes on at the same time. Other models operate with only a single tube a time.
EL Series UV Lamps Page 5
Service Procedures
Return Procedure
A Returned Goods Authorization (RGA) number must be obtained from UVP Customer Service before returning any product to UVP.
Cleaning and Care
Clean unit surface with a damp soft cloth or sponge. Never use abrasive cleaners (can damage the UV filter surface).
Replacing Tubes
Disconnect the lamp from the electrical supply before replacing tubes. Remove the two Phillips Head screws located in the end cap. Grasp the extruded housing and slide the chassis and filter out together away from the switch. Disconnect the interior Molex Connector (Fig. 1) and slide the chassis and filter out from the
housing completely.
Once out of the extrusion, the chassis and filter will come apart.
EL Series UV Lamps Page 6
Carefully grasp the tube ends and twist one quarter turn until it works free (Fig. 2)
Insert the new tube, giving it a twist to lock in place. Reassemble the lamp. Do not pinch wires during assembly.
Replacement Parts/Accessories
For replacement parts or components not shown here, please call UVP Customer Service or place of purchase. Please have the lamp model available when you call.
Replacement Part Description Part Number
Tube, 4 watt, 365nm 34-0005-01 Tube, 4 watt, 254nm 34-0066-01 Tube, 4 watt, white 34-0003-01
Tube, 6 watt, 365nm 34-0034-01 Tube, 6 watt, 254nm 34-0015-01 Tube, 6 watt, 302nm 34-0044-01 Tube, 6 watt, white 34-0063-01
Tube, 8 Watt, 365nm 34-0006-01 Tube, 8 Watt, 254nm 34-0007-01 Tube, 8 Watt, 302nm 34-0042-01 Tube, 8 Watt, white 34-0056-01
Accessories Description Part Number
Spectacles, UV Blocking 98-0002-01 Goggles, UV Blocking 98-0002-02 Faceshield, UV Blocking 98-0002-04
EL Series UV Lamps Page 7
J-138 Lamp Stand
J-138 Lamp Stand 18-0063-01 C-65 Cabinet (for 8-watt lamps) 95-0257-01 C-10E Cabinet (for 4-watt lams) 95-0072-08
Technical Support
UVP offers technical support for all of its products. If you have any questions about the product’s use or, operation, please contact UVP’s offices at the following locations.
If you are in North America, South America, If you are in Europe, Africa, the Middle East, East Asia or Australia: Western Asia:
Call (800) 452-6788 or (909) 946-3197 Call +44(0) 1223-420022 Customer Customer Service regular business regular business days, between 9 am days, between 7 am and 5 pm PST and 5:30 pm
E-Mail: info@uvp.com E-Mail: uvp@uvp.co.uk
Fax Customer Service: (909) 946-3597 Fax Customer Service: +44(0)1223-420561
Write to: UVP, LLC Write to: Ultra-Violet Products Ltd.
2066 W. 11th Street Unit 1, Trinity Hall Farm Estate, Nuffield Rd
Upland, CA 91786 USA Cambridge CB4 1TG UK Note: A Returned Goods Authorization (RGA) number must be obtained from UVP Customer
Service before returning any product.
C-65 Cabinet
C-10E Cabinet
Warranty
LIMITED WARRANTY: UVP's quality instruments are guaranteed to be free of defects in materials, workmanship, and manufacture for one (1) year from date of purchase. Transilluminators are similarly warranted for two (2) years from the date of purchase. Consumable and disposable products, including, but not limited to lamps or light tubes, filters, or rechargeable batteries are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
If equipment failure or malfunction occurs during the warranty period, UVP shall examine the inoperative equipment and have the option of repairing or replacing any part(s) which, in the sole and absolute discretion of UVP, were originally defective or became so under conditions of normal usage and service. No warranty shall apply to any instrument, or part thereof, that has been subject to accident, negligence, alteration, abuse or misuse by the end user. Moreover, UVP makes no warranties whatsoever with respect to parts not supplied by UVP
EL Series UV Lamps Page 8
or that have been installed, used and/or serviced other than in strict compliance with the instructions appearing in this installation and instruction manual. In no event shall UVP be responsible to the end-user for any incidental or consequential damages, whether foreseeable or not, including but not limited to property damage, inability to use equipment, loss of business, loss of profits, or inconvenience arising out of or connected with the use of instruments produced by UVP. Nor is UVP liable or responsible for any personal injurie s occurring as a result of the use, misuse, installation and/or servicing of equipment. Representations and warranties made by any person, including dealers and representatives of UVP which are inconsistent or in conflict with the terms of this warranty (including but not limited to the limitations of the liability of UVP as set forth above), shall not be binding upon UVP unless reduced to writing and approved by an expressly authorized representative of UVP.
THIS WARRANTY IS EXPRESSED IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON UVP’S PART AND UVP NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR UVP ANY OTHER LIABILITIES IN CONNECTION WITH THE SALE OF THE SAID PRODUCTS.