sources. operation. Highly accurate. For measuring ultraviolet intensity from ultraviolet ultraviolet. Compact (fits in the hand). Removable sensors call for ease of models J-221, which measures longwave (365nm), or J-225 shortwave (254nm) sors with 3' electrically shielded cord. Also available are Blak-Ray Meters in can be used. Units are hand-held, battery operated, and have compact sen­surements at 365nm, 300nm and 254nm, the new UVX Digital Radiometer highest accuracy , and interchangeable sensors (ordered separately) for mea­Ultraviolet Intensity Meters ... For widest energy range measurements,
prescription glasses. sporadic lower intensity UV light sources and can be worn comfortably over or high intensity UV light sources while the UVC-303 Spectacles are used for bands of UV . UVC-503 Goggles provide maximum protection from extended lenses reduces “blue haze” interference while protecting eyes form harmful is recommended when using any shortwave UV product. Special formula
Blak-Ray® Safety Goggles and Contrast Control Spectacles ... Eyewear
ACCESSORIES
Goods (RGA) number prior to sending the unit.
repair , call UVP’s customer service department for a Return Authorization Contact UVP’s offices with any questions. To return a unit to the factory for
REPAIRS
horizontally or vertically . bolt or screw the brackets to the desired location. The lamp can be mounted All lamps come with wall mounting brackets attached to the housing. Simply
MOUNTING INSTRUCTIONS
questions, contact UVP’s offices. does not light after replacing the bulbs, replace the starter. For any other removing. Note that the reflector is not screwed into the housing. If lamp unit and remove the filter cover. Carefully twist tubes out using care when T o replace the tubes in the lamps, remove the two screws on each side of the
REPLACING THE TUBES
end bracket. Replace the filter/frame assembly and screws. To change the filter , remove the two screws on the filter frame and remove
replace filters earlier than normal. level of fluorescent response, you may have to bring the lamp closer or within a reasonably close range, but if you are showing specimens of lower response. The brighter specimens will often respond for over 1000 hours if in a fixed position. Not all fluorescent minerals have the same brightness 1000 or more hours of operation can be expected. A display lamp is normally replacement periodically . Depending on the application, a lifetime of 500 to Shortwave filters are subject to deterioration due to solarization, and need
Filter/Frame
UVM-225D 38-0207-01 34-0072-01 (302nm Midrange) UVLS-225D 38-0207-01 34-0073-01 and 34-0060-01 UVS-225D 38-0207-01 34-0073-01 (254nm Shortwave) UVL-225D 38-0207-02 34-0060-01 (365nm Longwave)
Model Assembly Tubes
REPLACEMENT PARTS
REPLACING A FIL TER
supplied with an eight-foot cord and plus brackets for hanging the lamp. All display lamps are turned on and off with a single switch. Each lamp is
OPERATION
Mineralight Display Lamps
WARRANTY
UVP , LLC warrants it s ultraviolet lamps to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. Bulbs and filters are warranted for 90 days. The foregoing warranty of UVP shall be of no force and effect if buyer has modified or damaged the product.
All warranties or merchantability and fitness for any purpose and all other warranties, expressed or implied, except those expressly set forth herein, are deemed waived and excluded.
UVP’s duty under the warranty is limited to replacement and/or repair of the defective part at the option of UVP, LLC. UVP shall not be liable for any expenses or damages incurred by the purchaser except as expressly set forth herein, and in no event shall UVP be liable for any special, incidental or consequential damages of any kind. This warranty does not supersede any statutory rights that may be available in certain countries.
OPERATING INSTRUCTIONS
MINERALIGHT® DISPLAY LAMPS
W ARNING
Do not look into a lighted shortwave Mineralight lamp as it can quickly sunburn your eyes and skin. Always hold Mineralight lamps so that the light beams are away from you. Use protective eye/face wear and clothing.
ULTRAVIOLET LIGHT
UV energy cannot be detected by the human eye. A bluish light will be visible through the filter of your lamp. This is due to the emission of visible light from the tube. The special filter eliminates most of this visible light interference.
Shortwave ... The ultraviolet energy farthest from visible light, shorter than rays in sunlight and primarily noted for its ability to fluoresce minerals for chemical analysis and for its germicidal effects.
Midrange ... The ultraviolet energy representing the shortest wavelenghts found in sunlight, causing sunburn, and used to fluoresce certain substances more effectively than shortwave or longwave UV light.
Web Site: www.uvp.com
Corporate Headquarters: UVP, LLC 2066 W. 11th Street, Upland, CA 91786 USA
(800) 452-6788 or (909) 946-3197 • Fax: (909) 946-3597
European Sales Office: Ultra-Violet Products Limited
Unit 1, Trinity Hall Farm Estate, Nuffield Road, Cambridge CB4 1TG UK
+44(0)1223-420022 • Fax: +44(0)1223-420561
Mineralight and Blak-Ray are registered trademarks of UVP, LLC
81-0019-03 Rev D
Longwave ... The ultraviolet energy nearest to the visible light range (com­monly called blacklight), activates fluorescence in numerous natural sub­stances and manufactured materials.
Loading...